First and Only Disposable Infant T-Piece Resuscitator. Because they are not miniature adults...

Similar documents
EMERGENCY AIRWAY MANAGEMENT SOLUTIONS

1st Response Disposable Manual Resuscitators. Safe Convenient Trusted

Operation and Maintenance of the EPV200 Portable Ventilator

Inspire rpap REVOLUTION FROM THE FIRST BREATH

Emergency Transport and Ventilation

Respiratory. Products by Galemed

Hospital and Transport for Controlled Breathing

AUTOVENT 4000 VENTILATOR

Unit 15 Manual Resuscitators

Provide Comfort to your Patients is our commitment PRODUCT CATALOGUE HOSPTIAL SUPPLIES. Copyright ReadMed Company Ltd

Glostavent Helix spare parts

#HZ-9968 Resuscitator Bag Holder, wall-mounted Wall-mounted with universal cradle.

Oxygen Delivery Systems:

PORTABLE MEDICAL AIR SYSTEM

Great products available through ROI!

Oxygen Therapy Devices

System Flow Chart. ventilation patient connection

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP

CATALOGUE. Adult and Infant Respiratory Care Catalogue

ECO2 spare parts. Issue: 2017/002np

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

respiratory care aerosol therapy

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

O-Two Self-Study Guide. Equinox Relieve

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

GE Healthcare. Aestiva/5. More than superior ventilation

Respiratory Care. and Aerosol Therapy

Children Small Adults Newborns Small Children

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

(Delivery System) Pocket Guide. Series 3 software

INTENSIVE CARE VENTILATORS

PRODUCT CATALOG. Every Breath Matters. ARC Medical, Inc. circuitguard ThermoFlo PneumoniaCheck Cowan Road Tucker, GA 30084

Neonatal Care. Besmed products are manufactured under international quality standards for medical device and marked with CE.


Automatic Transport Ventilator

Test lungs from IMT Analytics simulate a range of realistic ventilation situations during training.

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

OxyTOTE PORTABLE OXYGEN SYSTEM

VT650. Gas Flow Analyzer. Technical data. Key benefits and features:

NEONATAL/INFANT VENTILATOR

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Virginia Beach EMS. Oxylator EMX. Debra H. Brennaman, RN, MPA, NREMT-P

Flight Medical presents the F60

Anesthesia. Midmark Animal Health Products

MANUAL RESUSCITATOR. EDM AN Eng. V

(Delivery System) Pocket Guide Series 3 software

SLE5000 Infant Ventilator with HFO

Quick Response Pneupac VR1 Emergency Ventilator AIRWAYMANAGEMENT

REGULATORS FLOWMETERS HUMIDIFIERS. Professional GAUGES ASSESSORIES. Medical Apparatus. and Assessories ISO 13485/ISO 9001 CERTIFICATION

Mass Casualty Ventilator Models: MCV100 & MCV100-B

Ref: TB Issue date: October 2012

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

KOALA. Disposable Adult Anaesthetic Circuits for Low Flow Anaesthesia KO.S5.22MM. Adult Anaesthetic Circuits. Medical Pty Ltd

SLE5000 Neonatal Ventilator with High Frequency Oscillation

VT900. Gas Flow Analyzer. Technical data. Key benefits and features:

Welcome to Maxstar Medical

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

Flowmeters & Accessories Guide

Corporate Overview and Product Summary

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

TITAN Oxygen Regulators

Welcome to the Specialized Medical Services Respiratory training webinar series!

CPR MEDICAL DEVICES INC. OPERATING MANUAL

suction and oxygen therapy

HIGH FREQUENCY JET VENTILATION (HFJV): EQUIPMENT PREPRATION

Technical Data and Specifications

General Anaethesia Airway

Mass Casualty Ventilator

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

BiPAP Vision Ventilator Testing with Various Patient Interfaces Report February 18, 2002

I nternational consensus 2and guidelines from

pneuton Transport Ventilator

Medical Instruments in the Developing World

How Ventilators Work. Chapter 3

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING

birth: a transition better guidelines better outcomes the birth experience a challenging transition the fountains of life: 2/8/2018

Aespire 7100 Essential performance Compact design

HAMILTON-T1 HAMILTON-T1. Intelligent transport ventilation

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Completed downloadable Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 5th Edition by Cairo

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Neonatal tidal volume targeted ventilation

Dameca MRI 508. State-of-the-art MRI technology

Solutions. Digital pressure management solutions. Copyright 2013 GaleMed Corporation

C O R P O R AT E B R O C H U R E

OXY-life TM. Oxygen Resuscitator OPERATING MANUAL

OXYGEN THERAPY FLOWMETERS, REUSABLE AND SINGLE-PATIENT HUMIDIFIERS, PRESSURE REGULATORS, FLOW SELECTORS

Table of contents. Breathing Circuit. Neonatal Care. Anesthesia Circuit. Accessories

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

ASSISTANCE. Cardinal Health Pulmonetic Systems Medina Rd., Suite 100 Minneapolis, Minnesota

MACS Mask CPAP System

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Mechanical ven3la3on. Neonatal Mechanical Ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on 8/25/11. What we need to do"

Blease900 Ventilator PATIENT CENTERED VENTILATION

Optimized Resuscitation. Cardiac massage and ventilation. Ideen bewegen mehr.

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

Neonatal resuscitation 2: An evaluation of manual ventilation devices and face masks

The following materials represent the Vortran Training Program available on the Access CE website

Complex Care Hub Manual: Pressure Ventilation on the LTV 1200

Transcription:

First and Only Disposable Infant T-Piece Resuscitator In-Line PIP Controller New Override Button Easier to Read Manometer New PIP Controller with Override Button allows clinicians to reach higher pressures > 40 cm H 2 O. + www.mercurymed.com Your Need... Our Innovation Neo-Tee Configuration Controller 12 from TEE Because they are not miniature adults...

Providing affordable T-Piece Resuscitation for every NICU bed. Introducing a better way to deliver positive pressure ventilation to your infant patients with convenient in-line viewing and reliable easy-to-read airway pressure manometer with optional pressure relief override button. The Neo-Tee is flow-controlled and pressure limited. It offers the ability to measure a more consistent, targeted Peak Inspiratory Pressure (PIP) and Positive End-Expiratory Pressure (PEEP). With the new Neo-Tee, there s absolutely NO capital equipment to purchase and it is completely disposable. Even Better... No fatigue from squeezing a bag since there is no bag to squeeze! New Optional Pressure Relief Override Button Undoubtedly an industry first, Neo-Tee is the only disposable T-Piece device on the market today that offers an improved built-in, easy-to-read monitor on the Tee with optional pressure relief override button for clinicians to override pressure to ranges between 40-60 cm H 2 O providing convenient, in-line viewing of delivered airway pressure. New style manometer has larger numbers and is easier to view, especially in dim NICU lighting conditions. Mercury Medical 11/2014 ML2014-299 Rev. A

The Neo-Tee includes a built-in pressure relief valve as an added safety measure, limiting ventilatory pressures to 60 cm of H 2 O and the stay-put PEEP valve allows for quick and easy PEEP pressure adjustments as needed. Advantages In-Line Controller Allows clinicians to change airway pressure in-line closer to the patient. Disposable Reduced chance of cross-infection, No cleaning required No capital equipment costs, Affordable at every bedside Space saving Lightweight and easily transported Portable, Convenient in-line viewing, accurate and easy-to-read dial Built-in Manometer (+/- 3 cm H 2 O up to 15 cm H 2 O and +/- 5 cm H 2 O above on Tee 15 cm H 2 O) accuracy (0-60 cm H 2 O) Adjustable PIP Controller/ Built-in Pressure Relief Compact for setting/adjusting pressure Connects to a flowmeter Optional PIP controller with override button enables pressure to go to ranges between 40-60 cm H 2 O when required Variable PEEP Knob Variety of Mask Sizes/Styles Increasing/Decreasing Pressure made easy Easy-to-turn dial, stays put at desired pressure Choice of clear anatomical and round silicone face masks in both neonatal and infant sizes Standard adjustable, easy-to-read PIP controller and safety pressure relief Product Specifications Delivered Oxygen Concentration Up to 100% Cycling Pressure Range 0 to 60 cm H 2 O Dead Space 4 ml Expiratory Resistance 0.2 cm H 2 O at minimum PEEP setting @ 6 LPM Inspiratory Resistance 1.6 cm H 2 O at minimum PEEP setting @ 6 LPM Input Gas Flow Range Minimum 5 LPM Maximum 15 LPM Integral Patient Circuit Manometer Accuracy - up to 15 cm H 2 O +/- 3 cm H 2 O - Greater than 15 cm H 2 O +/- 5 cm H 2 O Maximum Pressure on Controller 60 cm H 2 O +/- 5 cm H 2 O @ 15 LPM (dependent on flow rate) Operation Time Full E cylinder @ 660 Liters @ 5 LPM - 44 minutes Device Mass 83 g Patient Connection on T-Piece 15mm Taper Female (ISO 5356-1) PIP Controller Connection Mates with fittings that meet CGA 1240 oxygen Gas Delivery Pressures: D.I.S.S. standard Peak Inspiratory Pressure Range 0-60 cm H 2 O Positive End Expiratory Pressure PEEP Range @ 5 LPM up to approximately 2 cm H 2 O @ 8 LPM up to approximately 6 cm H 2 O @ 10 LPM up to approximately 9 cm H 2 O @ 15 LPM up to approximately 15 cm H 2 O Infant T-Piece Resuscitator Adjustable PIP Controller with built-in pressure relief (Shown on Flowmeter) 0-60 cm H 2 O 0086 DEHP-Free

Another important development in Infant Tee-Piece Resuscitation. Ordering Information Infant T-Piece Resuscitator Flow-Controlled and Pressure Limited Part # Description 0-60 cm H 2 O Quantity 10-50820 Neo-Tee Infant T-Piece Resuscitator, Circuit, 0-60 cm H 2 O Manometer, Controller & Override Button, Clear Anatomical Infant Face Mask 10-50821 Neo-Tee with in-line Controller 0-60 cm H 2 O Manometer & Override Button, Clear Anatomical Infant Face Mask, packaged in drawstring bag 10-50822 Neo-Tee with in-line Controller 0-60 cm H 2 O Manometer & Override Button, No Mask, packaged in drawstring bag 10-50823 Neo-Tee with in-line Controller 0-60 cm H 2 O Manometer & Override Button, Clear Anatomical Infant Face Mask & Neonatal Mask, packaged in drawstring bag NOTE: All in-line Neo-Tee are packaged in a drawstring poly bag. PRSRT STD U.S. POSTAGE PAID Permit #579 St. Petersburg, FL

First and Only Disposable Infant T-Piece Resuscitator In-Line PIP Controller Easier to Read Manometer New In-Line PIP Controller allows clinicians to change airway pressure closer to the patient. Neo-Tee Configuration Controller 12 from TEE + Your Need... Our Innovation Because they are not miniature adults...

Your Need...... our Innovation! Introducing a better way to deliver positive pressure ventilation to your infant patients with convenient in-line viewing and reliable easy-to-read airway pressure manometer. Mercury Medical is pleased to announce the first single-patient-use infant T-piece Resuscitation device. The Neo-Tee is flow-controlled and pressure limited. It offers the ability to measure a more consistent, targeted Peak Inspiratory Pressure (PIP) and Positive End-Expiratory Pressure (PEEP). With the new Neo-Tee, there s absolutely NO capital equipment to purchase and it is completely disposable. Even Better... No fatigue from squeezing a bag since there is no bag to squeeze! Original Neo-Tee Flowmeter Color-Coded Neo-Tee Adjustable PIP Controller with Pressure Relief Variable PEEP Knob Providing affordable T-Piece Resuscitation for every NICU bed. PEEP Knob Hole Adjustable Pressure Knob Circuit/Tubing Built-In Color-Coded, Low-Range Manometer Patent # US 5,557,049 B1, Patent # US 8,522,618 B1 Other Patents Pending Undoubtedly an industry first, Neo-Tee is the only disposable T-Piece device on the market today that offers a built-in, easy-to-read monitor on the Tee for providing convenient, in-line viewing of delivered airway pressure. While budget constraints may prevent having capital equipment for the best patient care where its needed the most, just imagine having an affordable device like the Neo-Tee at every NICU bedside. Mercury Medical 12/2014 ML2010-152 Rev. E

The Neo-Tee includes a built-in pressure relief valve as an added safety measure, limiting ventilatory pressures to 40 cm of H 2 O and the stay-put PEEP valve allows for quick and easy PEEP pressure adjustments as needed. Advantages In-Line Controller Disposable Portable, Built-in Manometer on Tee Adjustable PIP Controller/ Built-in Pressure Relief Variable PEEP Knob Variety of Mask Sizes/Styles Allows clinicians to change airway pressure in-line closer to the patient. Reduced chance of cross-infection, No cleaning required No capital equipment costs, Affordable at every bedside Space saving Lightweight and easily transported Convenient in-line viewing, accurate and easy-to-read dial (+/- 3 cm H 2 O up to 15 cm H 2 O and +/- 5 cm H 2 O above 15 cm H 2 O) accuracy (choice of 0-40 cm H 2 O or 0-60 cm H 2 O) Compact for setting/adjusting pressure Connects to a flowmeter Safety Pressure Relief activates at 40 cm H 2 O The Adjustable PIP Controller allows clinicians to limit airway pressure to 40 cm H 2 O Increasing/Decreasing Pressure made easy Easy-to-turn dial, stays put at desired pressure Choice of clear anatomical and round silicone face masks in both neonatal and infant sizes Standard adjustable, easy-to-read PIP controller and safety pressure relief Universal Round O 2 D.I.S.S. Connector on in-line Neo-Tee New! T-Piece Circuits Only, without manometer Now includes Cap & Strap Product Specifications Delivered Oxygen Concentration Up to 100% Cycling Pressure Range 0 to 40 cm H 2 O Dead Space 4 ml Expiratory Resistance 0.2 cm H 2 O at minimum PEEP setting @ 6 LPM Inspiratory Resistance 1.6 cm H 2 O at minimum PEEP setting @ 6 LPM Input Gas Flow Range Minimum 5 LPM Maximum 15 LPM Integral Patient Circuit Manometer Accuracy - up to 15 cm H 2 O +/- 3 cm H 2 O - Greater than 15 cm H 2 O +/- 5 cm H 2 O Maximum Pressure on Controller 40 cm H 2 O +/- 5 cm H 2 O @ 15 LPM (dependent on flow rate) Operation Time Full E cylinder @ 660 Liters @ 5 LPM - 44 minutes Device Mass 83 g Patient Connection on T-Piece 15mm Taper Female (ISO 5356-1) PIP Controller Connection Mates with fittings that meet CGA 1240 oxygen Gas Delivery Pressures: D.I.S.S. standard Peak Inspiratory Pressure Range 0-40 cm H 2 O Positive End Expiratory Pressure PEEP Range @ 5 LPM up to approximately 2 cm H 2 O @ 8 LPM up to approximately 6 cm H 2 O @ 10 LPM up to approximately 9 cm H 2 O @ 15 LPM up to approximately 15 cm H 2 O Infant T-Piece Resuscitator Adjustable PIP Controller with built-in pressure relief (Shown on Flowmeter) 0086 DEHP-Free

PRSRT STD U.S. POSTAGE PAID Infant T-Piece Resuscitator Permit #579 St. Petersburg, FL Ordering Information Part # Description Flow-Controlled and Pressure Limited Quantity 10-50800 Neo-Tee Infant T-Piece Resuscitator, Circuit, Controller, No Mask, 0-60 cm H 2 O Manometer 10-50801 Neo-Tee Infant T-Piece Resuscitator, Circuit, Controller, Clear Anatomical Infant Face Mask, 0-60 cm H 2 O Manometer 10-50802 Neo-Tee Infant T-Piece Resuscitator, Circuit, without Controller, No Mask, 0-60 cm H 2 O Manometer 10-50803 Neo-Tee Infant T-Piece Resuscitator, Circuit, without Controller, Clear Anatomical Infant Face Mask, 0-60 cm H 2 O Manometer 10-50804 Neo-Tee Infant T-Piece Resuscitator, Circuit, Controller, No Mask, 0-40 cm H 2 O Low Range Manometer 10-50805 Neo-Tee Infant T-Piece Resuscitator, Circuit, Controller, Clear Anatomical Infant Face Mask, 0-40 cm H 2 O Low Range Manometer 10-50806 Neo-Tee Infant T-Piece Resuscitator, Circuit, No Controller, No Mask, 0-40 cm H 2 O Low Range Manometer 10-50807 Neo-Tee Infant T-Piece Resuscitator, Circuit, No Controller, Clear Anatomical Infant Face Mask, 0-40 cm H 2 O Low Range Manometer 10-50808 Neo-Tee Infant T-Piece Resuscitator, In-Line Controller, Circuit, No Mask, 0-60 cm H 2 O Manometer 10-50809 Neo-Tee Infant T-Piece Resuscitator, In-Line Controller, Circuit, Clear Anatomical Infant Face Mask, 0-60 cm H 2 O Manometer 10-50810 Neo-Tee Infant T-Piece Resuscitator, In-Line Controller, Circuit, No Mask, 0-40 cm H 2 O Low Range Manometer 10-50811 Neo-Tee Infant T-Piece Resuscitator, In-Line Controller, Circuit, Clear Anatomical Infant Face Mask, 0-40 cm H 2 O Low Range Manometer 10-50812 Neo-Tee Infant T-Piece Resuscitator, Circuit, Controller, Clear Anatomical Infant Face Mask, 0-60 cm H 2 O Manometer, packaged in drawstring bag 10-50813 Neo-Tee Infant T-Piece Resuscitator, Circuit, without Controller, No Mask, 0-60 cm H 2 O Manometer, packaged in drawstring bag 10-50814 Neo-Tee Infant T-Piece Resuscitator, Circuit, In-Line Controller, Clear Anatomical Infant Face Mask, Clear Anatomical Neonatal Face Mask, 0-40 cm H 2 O Low Range Manometer 10-50815 Neo-Tee Infant T-Piece Resuscitator, 5 Expandable Circuit, 0-60 cm H 2 O Manometer, without Controller, No Mask packaged in drawstring bag 10-50816 Neo-Tee Infant T-Piece Resuscitator, 5 Expandable Circuit, 0-60 cm H 2 O Manometer, without Controller, Clear Anatomical Face Mask, packaged in drawstring bag 10-50817 Neo-Tee with in-line Controller, Round Silicone Face Masks (size 0 & 1), 0-60 cm H 2 O Manometer, packaged in drawstring bag 10-50818 Neo-Tee with in-line Controller, Clear Anatomical Neonatal Face Mask, 0-40 cm H 2 O Manometer, packaged in drawstring bag 10-50819 Neo-Tee Infant T-Piece Resuscitator, 5 Expandable Circuit, 0-40 cm H 2 O Manometer, without Controller, No Mask, packaged in a drawstring bag 10-50900 T-Piece Resuscitation Circuit Only - 6 Length, No Manometer, No Mask 10-50901 T-Piece Resuscitation Circuit, Anatomical Infant Cushion Face Mask, No Manometer, 6 Length 10-50902 T-Piece Resuscitation Expandable Circuit Only - 5 Length, No Manometer, No Mask 10-50903 T-Piece Resuscitation Expandable Circuit - 5 Length, Infant Cushion Mask, No Manometer 10-50904 T-Piece Resuscitation Circuit, Round Type Silicone, Round Silicone Face Mask, Size #0, No Manometer 10-50905 T-Piece Resuscitation Circuit & O 2 Tubing Kit: Circuit Only, 6 Length, No Manometer, No Mask, O 2 Tubing 7 with 10 mm D.I.S.S. 10-55321 Connector Adaptor for Transport (non in-line application) 10-55322 Replacement Oxygen Tubing, D.I.S.S. Male x D.I.S.S. Female - 7 Length 25/Box 10-55323 Replacement Oxygen Tubing, 10 Length, 10 mm Male x Tubing Nipple - Fits Fisher & Paykel NeoPuff 25/Box MASKS 10-50504 Clear Anatomical Infant Face Mask 20/Box 10-50505 Clear Anatomical Neonatal Face Mask 20/Box 10-50601 Round Type Silicone Face Mask, Size 0 (48mm) 10-50602 Round Type Silicone Face Mask, Size 1 (60mm) Lung CK-1021 Infant Test Lung (64 ml) 10/Pkg NOTE: All in-line Neo-Tee are packaged in a drawstring poly bag. All Neo-Tee include cap & strap (dust cap) Another important development in Infant Tee-Piece Resuscitation.