Table of Contents 1 Introduction 2 Technical specifications 3 Included in the delivery 4 Function description 5 Mounting Nortek AOS buoy

Similar documents
DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

QUICK START GUIDE CB-150 DATA BUOY PLATFORM

QUICK START GUIDE CB-450 DATA BUOY PLATFORM

Three Lakes Association Hydrolab for Dummies. Table of Contents:

QUICK START GUIDE CB-950 DATA BUOY PLATFORM

Optical Dissolved Oxygen Meter

BUYER S GUIDE AQUAlogger 520

Heavy Duty Dissolved Oxygen Meter

Optical Dissolved Oxygen Meter

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

with O 2 Controller Instruction Manual

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

AA100 Acoustic Actuator

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Model 130M Pneumatic Controller

Arbor Terminator Press Operation Manual For IDT Connectors Order No Engineering No: AM

MAPCO2 Buoy Metadata Report Project Title:

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

CJMJ.DPNQBDU. Instruction for use. Neonatal phototherapy device. BILI-COMPACT WY 1816/ Year of manufacture D2017_00

D-OptoLogger Dissolved Oxygen Logger Operation Manual

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

LogIT Dissolved Oxygen Probe

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.

_ pressure transducers. User Manual

Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President

DPC-30 DPC-100. Reference Manual

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

SS32L Dissolved O 2 Probe

NEULOG OXYGEN LOGGER SENSOR GUIDE

Columbus Instruments

RJE INTERNATIONAL, INC.

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

testo Leakage detector for refrigerants Instruction manual

CSBUOY-DT INSTRUCTION MANUAL

12mm Dissolved Oxygen Sensor Care and Use Instructions

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

9A5N Solid State CW Paddle

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

HI 2314 HI 2315 HI 23151

Hurlcon KX Siesta Above Ground Salt Water Chlorinator by AstralPool Australia

FRONT DERAILLEUR - CURRENT RANGE

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Model 106 DPI "Micro-switch" Installation and Operating Instructions

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

OXYGEN MICROOPTODE - OPTO SERIES USER MANUAL

- TD 262b OPERATING MANUAL PRODUCT XXXX Date February 2013 OPERATING MANUAL SEAGUARD RCM

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

Dissolved Oxygen/Temp Waterproof Tester

Calcium Reactor. CalcFeeder PRO. User Manual 1.1a. Model. CalcFeeder AC1 PRO CalcFeeder AC2 PRO CalcFeeder AC3 PRO CalcFeeder AC4 PRO

In Vivo Scientific, LLC INSTRUCTION MANUAL

Float Operated Level Controllers

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

S4W PRO ROBOT. User Manual. paddlepalace.com

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

DIVER NAVIGATION BOARD. RJE International, Inc. RJE International Feb 1, TAC-100D Revision 10

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum

Index Table. Model 794. Installation, Operating and Maintenance Instructions

BMR 2100XL Operating Instructions Page 1 of 13

CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL

HI 9143, HI 9143M HI 9145

QUICK START GUIDE TO DRINKING WATER MONITORING

Advanced Test Equipment Rentals ATEC (2832)

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

Paddle Bar Replacement

Membrane covered optical CO 2 sensor

CB-150 Data Buoy Quick Start Guide

INSTALLATION MANUAL JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. Before installation. Installation INSTALLATION MANUAL: B700

WELCOME TO THE REVOLUTION

Ladies Shopper Bike Assembly Manual 28C03

BUYER S GUIDE AQUAlogger 530WTD

Regulators repair and maintenance. XS Compact 2nd stage. January 2014 Rev XSC /3 Ed. C /14 1

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Dissolved Oxygen Sensor

Final Assembly Instructions Bikes with Threaded Headsets

ASG-SD2500 ASG-SD2500

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Best Practice for Calibrating LTH Conductivity Instruments

Smooth Vent Valve. XVD Series

Installation and Operation Manual

AANDERAA. Measuring: Current Speed Current Direction Temperature

Final Assembly Instructions Bikes with Quill Stems

MOTUS Wave Buoys. Powered By the Aanderaa MOTUS Directional Wave Sensor

Transcription:

2 Table of Contents 1 Introduction 3 2 Technical specifications 4 3 Included in the delivery 5 4 Function description 6 5 Mounting Nortek AOS buoy 7 6 Deployment and mooring 10 7 Setup webpage 12 8 Change batteries 13 9 Maintenance 14 10 Service and repair 16

Introduction 3 1 Introduction Congratulations with your new Nortek AOS Buoy! Nortek AOS Buoy is a flexible, battery operated and complete system which offers online access to currents, oxygen and/or salinity data from virtually any location worldwide. Data is communicated from the connected sensors to a communication device (named AOS tube) and an iridium satellite modem communicates the data to a server. The serves saves your AOS data, and through a cloud hosted web application (www.aos.nortek.no), you will always find your updated real time data. The Nortek AOS Buoy is built to withstand rough treatment and includes a radar reflector. In addition there is an option to install a blinking signal light. This manual contains a mounting manual and other useful information. If there are any uncertainties, we recommend sending an email for guidance. In addition, please contact us if you find any information missing. We appreciate your feedback, and other users will too! Contact information: Email: inquiry@nortekgroup.com (general email) or support@nortekgroup.com for technical question. Adress: Nortek AS Vangkroken 2 1351 Rud Norway

4 2 Nortek Sensor Buoy Technical specifications Weight and dimensions Weight Diameter Length Sensor contacts Power Batteries ~40kg 400mm 2500mm 1*8-pin (Aquadopp Profiler) and optional 1*5/6-pin (oxygen-/salinity sensor) 6 * 100 Wh alkaline batteries (Nortek) Environment Operating temperature - 20 C til + 45 C Data communications Data transfer Current measurements Nortek Aquadopp Profiler. Further details in data sheets. Aquadopp Profiler 400 khz Aquadopp Profiler Z-Cell 600 khz Aquadopp Profiler 2 MHz Iridium (http://www.nortekgroup.com/products/ aquadopp-profiler-400-khz) (http://www.nortekgroup.com/products/ aquadopp-z-cell-600-khz) (http://www.nortekgroup.com/products/ aquadopp-profiler-2-mhz) Oxygen sensor Manufacturer: Insite IG, Dissolved Oxygen Model 31 Measurement parameters: Oxygen and temperature Sensor technology: Optical Maximum depth: 50 meter Measurement range: 0-25 ppm Precision: 1% of reading or 0.02ppm Resolution: 0.01ppm of reading, < 4ppm 0.1ppm of reading, > 4ppm Salinity sensor Manufacturer: Measurement parameters: Maximal depth: Measurement area, conductivity: Measurement interval: Resolution: Measurement, salinity: Resolution: Blinking light Manufacturer: System: Activation switch: Light intensity: Blinking interval: Ponsel Measure, CTZN Salinity (conductivity) and temperature 50 meter 0-100 ms/cm 0-70 ppt 0,01 ms/cm 5-60g/kg 0,01 g/kg Jotron AS, Tron ML-300 LED (yellow) ON/OFF daylight sensor 5 Cd 0.5 sec OFF/ 2.5 sec ON. 20 blink/min Data presentation Internet: www.aos.nortek.no

Included in the delivery 5 3 Included in the delivery 1. SPARBUOY-250 2. 6*100 Wh batteries and a battery tube 3. Shackle for chain mounting 4. Oxygen- or salinity sensor + clamp + 5/6-pin cable (if ordered) 5. Aquadopp Profiler + clamp 6. AOS tube + clamp 7. Blinking light (if ordered) In addition to the main components, the following is included: 2-pin/2-pin cable from AOS tube to battery tube 8-pin/8-pin cable from Aquadopp Profiler to battery tube 2-pin cable from battery tube to blinking light (if ordered) Screws kit Dummy plug

6 4 Nortek Sensor Buoy Function description More details about sensors and current measurements are available on Nortek's website ( www.nortekgroup.com), but the summary below may be useful: Current profiler: To start sampling, simply connect the instrument to the batteries. The current profiler is configured to measure current speed and direction every 10.minutes, at three depths: 5 m, 10 m and 15 m (if other is not specified). Battery tube: Contains 6 * 100 Wh alkaline (not rechargeable) batteries. The batteries are connected to the battery tube when shipped from Nortek. In other words, there is no need to connect the batteries to the battery tube first time the AOS buoy is deployed. The oxygen sensor is an optical sensor that measures percent dissolved oxygen (% saturation), based on a method called fluorescence. The sensor sends out energy as light, with very specific wave length (color) that goes through a material that fluoresces. Outside the fluorescent material there is a membrane that keeps out the water, while letting in oxygen molecules. The number of oxygen molecules is therefore in equilibrium with the number of oxygen molecules in the water outside. When the fluorescent light hits an oxygen molecule, the energy in the light decreases without the wavelength (color) changing. Oxygen also causes the energy in the light to be absorbed. If there is dissolved oxygen in the water, the returned light will have reduced energy, and this energy decrease is proportional to oxygen content. The salinity / conductivity sensor. Conductivity is the waters ability to conduct an electric current, and is indicated by the unit ms / cm (milli siemens). Salinity is a measure of salt content in a given amount of water, and is stated in g / kg (ppt). The sensor measures the conductivity by generating an electric field in the water using a coil, then measuring this electric field using another coil. The current measured by coil number two is proportional to conductivity in the water. Higher salinity leads to higher electrical conductivity. Conductivity increases at increasing temperature, therefore, the temperature is also measured. Salinity is calculated using oceanographic tables and standard equations. The internet webpage indicates the battery status. It is recommended to change batteries when the indicator turns red. The procedure for change of batteries is described in chapter 8.

Function description 7 5 Mounting Nortek AOS buoy We recommend to test the system before deployment. Make sure data from the current profiler and oxygen/salinity is displayed in www.aos.nortek.no. We recommend to mount the AOS buoy as described in the instructions below: 1: Open the top cover of the buoy. Mount the blinking light on the top cover with the four supplied screws (as picture 1a illustrates). Picture 1: a) Blinking light mounting, b) AOS tube mounting, c) Output AOS tube 2: To mount the AOS tube on the top cover of the buoy: First mount the clamp in the available hole in the top cover, and thread the tube halfway through the cover (1b). The antenna on the AOS tube should point in the same direction as the blinking light. Tighten the screws on the clamp and make sure the tube is fastened and is stuck. 3: The AOS tube has three outputs (picture 1c). One 8-pin for the Aquadopp profiler, a 2-pin for the battery cable and a 5-pin for the optional oxygen/salinity sensor. If the 5-pin output is not in use, protect the output with a dummy plug. 4: Pull the 8-pin cable from the AOS tube through the AOS buoy (2a). If using an additional sensor, pull the 5/6-pin through the buoy. Note: It is important to do this step before mounting the battery tube. Picture 2: Pull the cable(s) through the buoy. a) seen from top of buoy: cable pulled through buoy. b) seen from bottom of buoy: cable pulled through buoy.

8 Nortek Sensor Buoy 5: Fasten the clamp for the Aquadopp Profiler in the bottom of the buoy. If using an oxygen/ salinity sensor, fasten the related clamp to the bottom of the buoy as well. Picture 3: a) Clamp for Aquadopp Profiler. b) Place the bracket in the slot. c) Adjust and align the clamp with the holes in buoy. d) Use the supplied screws for fastening 6: Connect the 8-pin cable to the Aquadopp Profiler (4a). If using an oxygen sensor, connect the 5/6-pin cable to the sensor. Picture 4: a) Connector between Aquadopp Profiler and cable. b) Push Aquadopp Profiler through the clamp. c) Tighten the screws. 7: Push the Aquadopp Profiler as far as possible into the buoy through the clamp. If it is not possible to push the instrument as far as picture 4b illustrates, please contact Nortek for a solution. Note: Rotate the head so the transducers looks away from the shackle and mooring rope. 8: Tighten the clamp screws for the Aquadopp Profiler. Do the same procedure for oxygen/ salinity sensor. 9: From the top of the buoy, thread the battery tube in place. There is an indent in the battery tube collar for the cables (5). Picture 5: a) Place the cables in the indent of the battery tube collar. b) Mount the cable from the AOS tube and the cable from the blinking light to the battery tube. c) Use the supplied locking splints to fasten the

Mounting Nortek AOS buoy 9 10: Fasten 2-pin cable from the AOS tube to the battery tube (5b). Fasten the 2-pin cable from the blinking light to the battery tube. 11: Use two of the supplied locking splints to fasten the battery tube to the inside of the buoy. 12: Fasten the top cover to the buoy and lock with supplied locking splint. 13: The Nortek AOS buoy is ready for deployment. Use the supplied shackle to fasten the chains and mooring rope to the bottom of the buoy before deployment.

10 Nortek Sensor Buoy 6 Deployment and mooring Nortek AOS buoy can be mounted at great depths and in strong currents. We have modeled and collected data based on tests of the hydrodynamic behavior during typical current environments. The table with the data collected (see below) can be used as a guidance for deployment. Please don't hesitate to contact Nortek for assistance. A typical buoy-mooring is presented in figure 1. Subsurface buoys is installed at 30 meter depth if necessary. Note: Make sure that the current profiler transducers point away from any mooring rope as it will cause disturbance in the data. Mooring. Lengths/weights are just examples. See table below for more details. Standards: Mooring rope: Length of rope below buoy: Mooring weight in water column: Length of top rope: Sub-surface buoy: Bottom rope: Mooring weight, anchor: 8 mm dyneema rope 10 m 10 m chain, 80 kg See table below 14 Nokalon buoy Depends on total depth. See table below See table below Note: In the following tables it is assumed a maximum current of 1 m/s in shallow water. "Length of top rope" needs to be adjusted if a location is exposed of stronger currents than this. In deep water, the data is presented as functions of the number of subsurface buoys. Subsurface buoys are an important parameter when it comes to hydrodynamic behavior in deep water. The percentage of used buoyancy is always <70% in the tables below. This is to be sure that the AOS buoy is not fully submerged underwater in the high current speed.

Deployment and mooring 11 Shallow water (40-100 m). Number of subsurface buoys is 0. Water depth Assumed maximum current speed Rope length, top rope Mooring weight, anchor < 40 m 1 m/s 5 m 150 kg 18 m 40 m 1 m/s 5 m 150 kg 18 m 60 m 1 m/s 10 m 200 kg 35 m 80 m 1 m/s 20 m 200 kg 55 m 100 m 1 m/s 20 m 250 kg 60 m Deep water (100-500 m). Water depth Total subsurface buoys Rope length, top rope Mooring weight, anchor Maximum horizontal displacement Maximum horizontal displacement 100 m 2 5 m 200 kg 30 m 200 m 2 10 m 300 kg 60 m 250 m 4 10 m 300 kg 65-70 m 300 m 4 15 m 350 kg 80-90 m 400 m 6 20 m 450 kg 125 m 500 m 8 20 m 600 kg 140 m

12 7 Nortek Sensor Buoy Setup webpage Note the stationid for the AOS tube. The 4-digit number is the final test documentation and it is written on the AOS tube. Log in to www.aos.nortek.no with username and password and access the data after the Nortek AOS buoy is deployed. Available functions at www.aos.nortek.no: Key parameters Customizable graphic display Historical data Option to download data to Excel Map

Setup webpage 13 8 Change batteries 1: To access the batteries and battery tube open the top cover on the buoy. Pull out the battery tube (picture 1a). 2: Unscrew the battery tube collar. Loosen the molex-contact between battery tube collar and the batteries. (Picture 1a-1b). 3: Take out the whole battery rail and observe how the batteries are mounted before removal. Replace with 6 new batteries and place the battery rail careful into the battery tube again. 4: Connect the 2-pin molex-contact to the battery tube collar again (1d). 5: Tighten the battery tube collar. Tip: Avoid twisting the internal cables: first, rotate battery tube cover 5 revolutions counter-clockwise. Second, put the collar on the battery tube and rotate clockwise until collar is full tightened (1e). 6: Place the battery tube back into the buoy, and make sure the cables for the current profiler (and sensor) are placed in the indent of the battery tube collar. 7: Fasten both of the 2-pin cables on the top of the battery tube collar. 8: Shut the top cover of the buoy and fasten with locking splint. As a confirmation of a successful battery change, check if the blinking light is blinking. Picture 1 a) Open top cover and drag out battery tube. b) loosen the white molex-connector. c) Take out the battery rail. Note the placement of the batteries. Replace with new batteries d) Connect the molex-contact. e) tighten the battery cover. We recommend to have a spare battery tube available, in that way, the battery tube is the only component to change in the field. This is to avoid changing exposed batteries in field environments.

14 9 Nortek Sensor Buoy Maintenance Maintenance: Recommended maintenance interval of the buoy is every third month. Check for bio fouling, mounting of mooring and mounting of instrument/sensor. Oxygen sensor: Bio fouling on oxygen sensor will affect the measurement. This usually leads to a decrease of the average oxygen level and/or unnaturally large variations between daytime and nightly measurements. This phenomenon will typically be more prominent in the summer, and we therefore recommend to pay extra attention in this period with regard to visual inspection and cleaning of the sensors. Simply clean the sensor by washing gently with soapy water and a soft sponge, cloth or brush (for example a toothbrush). Important! Do not use sharp tools. This can cause irreparable damage to the sensor. Salinity Sensor: Clean the sensor with soapy water and make sure the sensor hole is not clogged. Current profiler: For maintenance of the current profiler, the Service Chapter (Chapter 1) of the Nortek Comprehensive Manual is recommended and available for download here: http:// www.nortekgroup.com/manuals-quick-guides Maintenance interval: For oxygen and salinity, it is recommended to check the sensors once a week, especially if there is little experience with the level of bio fouling. Geographical differences and seasonal differences must also be included in the assessment. Our experience for the current profiler is that monthly checks are often enough. Again, location and season must be considered. Transportation: When transporting a Nortek AOS buoy, you may want to disassemble the instrument if you can not secure it properly. To do this, unscrew the two screws on the clamp for the current profiler (see picture below). Pull out the instrument and disconnect the underwater cable that goes to the communication device at the top of the buoy. Calibration: Oxygen Sensor: If the oxygen sensor(s) shows unnatural or unstable values, it may be a sign that recalibration is required. A simple test can be done before contacting Nortek: Test the sensor in a saturated solution. For example, use a bucket of tap water. Note that water from the tap will typically be over-saturated, so wait for approx. 30 minutes before the measurements are taken. Contact Nortek if the oxygen sensor is outside +/- 5% of the 100% saturated solution.

Maintenance 15 Salinity Sensor: The salinity sensor cannot be calibrated. The current profiler cannot be recalibrated. Contact Nortek if it is suspected that the instrument is not measuring correctly, and Nortek can perform a service/verification. Storage: The sensors and the instruments must be stored with care and protected against careless relocation/handling. Sensors should not be stored in cold environments, due to calibration purposes. If the system is stored over a long period of time, it can be disabled for a period of time to save costs. Please contact Nortek for more information.

16 Nortek Sensor Buoy 10 Service and repair Before sending a system to Nortek for repair - contact (support@nortekgroup.com) to receive an RMA number. This is a mandatory reference number that contributes to fast and trouble-free handling. Information that MUST follow the shipment: RMA Number StationID Company Name Contact person Delivery Address Invoice address Telephone Email Important! Freight insurance in connection with repairs is not covered by Nortek. Make sure the equipment is adequately insured before shipping. Please note that sensors exposed to severe mechanical stress (vibration/shock), may reduce target accuracy significantly and may be destroyed if they are not properly packaged. Nortek is not responsible for direct costs or costs of consequential damages associated with equipment being lost or destroyed during transport. Nortek insures shipment back to customer and bills this together with repair/shipping. In case of warranty repair, transport and freight insurance to Nortek's customer is covered.

Service and repair 17