Pressure Sensor 150 to 1150 mbar Product Number: ENPRS015

Similar documents
Measuring wind speed and direction

Flow Rate Sensor Product Number: ENFLO-A254A

Oxygen Sensor with Electrode

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Gas Pressure Sensor (Order Code GPS-BTA)

Experiments in Biology

Boyle s Law: Pressure-Volume Relationship in Gases

Experiment C-6 Gas Solubility

Boyle s law Verifying the relation between air pressure and volume measuring air pressure in a closed container.

Pressure Sensor Experiment Guide

NEULOG OXYGEN LOGGER SENSOR GUIDE

Exploring the Properties of Gases

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high)

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

Boyle s Law: Pressure-Volume Relationship in Gases

Exploring the Properties of Gases

BUYER S GUIDE AQUAlogger 530WTD

Vapor Pressure of Liquids

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

The NXT Generation. A complete learning solution

EXPERIMENT 12 GAS LAWS ( BOYLE S AND GAY-LUSSAC S LAW)

For The First Time Quad Doppler Radar and Dual Photometric Cameras in One Launch Monitor.» User Manual

Pneumatic high-pressure controller Model CPC7000

Experiment B-3 Respiration

Boyle s Law: Pressure-Volume. Relationship in Gases

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

Pneumatic high-pressure controller Model CPC7000

Model PDT Dewpoint Transmitter

Ideal gas law. Introduction

User s Guide. Pressure Controller for liquid delivery systems

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

Vapor Pressure of Liquids

Optical Dissolved Oxygen Meter

Boyle s Law: Pressure-Volume Relationship in Gases. PRELAB QUESTIONS (Answer on your own notebook paper)

Additel 761 Automated Pressure Calibrators

Operator s Manual. Rev F 8/29/ O Neil Rd, Macedon NY Telephone: (315) Fax: (315)

Physics Experiment 17 Ideal Gas Law Qualitative Study

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Exp. 5 Ideal gas law. Introduction

Optical Dissolved Oxygen Meter

RM-80 respiration monitor

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Vapor Pressure of Liquids

Boyle s Law: Pressure-Volume Relationship in Gases

TERRA NOVA - Wind energy - Standard Kit

PRODUCT MANUAL. Diver-Mobile for Android

Additel 761 Automated Pressure Calibrators Selection Guide

Experiment 11: The Ideal Gas Law

Additel 780 Series Pressure Controller

MODEL 100 NITROGEN INFLATION CART

Instruction Manual. BZ7002 Calibration Software BE

Oxygen Meter User Manual

Technology. Using Bluetooth

Boyle s Law VC 09. Experiment 9: Gas Laws. Abstract

DDR Dive Data Recorder Manual - Rel /12

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Additel 761 Automated Pressure Calibrators

Boyle s Law. Pressure-Volume Relationship in Gases. Figure 1

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The Gas Laws: Boyle's Law and Charles Law

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

D-OptoLogger Dissolved Oxygen Logger Operation Manual

WARRANTY, QUICK START GUIDE

Vapor Pressure of Liquids

ADT 761 Automated Pressure Calibrator

Lab #12:Boyle s Law, Dec. 20, 2016 Pressure-Volume Relationship in Gases

Gas Laws: Boyle s and Amonton s Laws MCTC Chemistry v.9.17

Additel 780 Series Pressure Controller

SENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide Palm OS. Version 2.0 Published October 17, ReefNet Inc.

Evaluation copy. Vapor Pressure of Liquids. computer OBJECTIVES MATERIALS

LAB 06 Organismal Respiration

Technology. Using Bluetooth

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

Clean toilet plunger Sensor extension cable. Add this important safety precaution to your normal laboratory procedures:

PRODUCT MANUAL. Diver Smart Interface Cable AS346

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

1001ICT Introduction To Programming Lecture Notes

Pre-Lab 6: Gas Law ~ 70 ~

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

QUICK START GUIDE Kestrel 5500 Weather Meter.

QUICK START GUIDE Kestrel 5500 Weather Meter.

29 Pressure, Temperature relationship of a gas

Datasheet May, 2017 HPSD 4000 Pressure Transducer 1/5. Applications

User s Guide. Vacuum Controller for liquid delivery systems

Ozobot Bit Classroom Application: Boyle s Law Simulation

Vapor Pressure of Liquids

AP Biology. Investigation 6: Cellular Respiration. Investigation 6: Cellular Respiration. Investigation 6: Cellular Respiration

Airox Supportair Ventilator

130 SSP Soluble Salt Profiler

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Air Pycnometer. Operating Manual. Umwelt-Geräte-Technik GmbH

User Manual MFCS TM -EZ

Transcription:

imagine explore learn Pressure Sensor 150 to 1150 mbar Product Number: ENPRS015 Overview One of the key factors in almost every experiment involving gases is pressure. The Pressure sensor measures gas pressure in the range of 150 to 1150 mbar (0.148 to 1.134 atm or 15 to 115 kpa). The sensor includes a Luer Lock Connector, allowing the sensor to be used with a wide range of equipment including small containers, syringes and valves. It is ideal for various experiments in Biology, Chemistry and Physics. The sensor can also be used as a barometer and altimeter giving it even greater flexibility. The Pressure sensor can be connected to all types of einstein data loggers. Typical experiments Biology Investigating the evaporation of water from terrestrial plants - transpiration Measuring the photosynthesis rate in water plants Measuring the respiration rate of germinating seeds Investigating the effect of light on photosynthesis rate

P r e s s u r e S e n s o r 2 Chemistry Investigating the Ideal Gas Law How it works The sensing unit inside the Pressure sensor changes its voltage as a result of a pressure change. This voltage is then converted to a range of 0-3 V and recorded by the logger. The sensor also integrates a temperature compensation mechanism. Sensor specification Range: Accuracy Resolution (12-bit): Temperature Compensation Response Time (for 90% change in reading): 150 to 1150 mbar 0.148 to 1.134 atm 15 to 115 kpa ±1.5 % over entire range @ 0-85ºC 0.27 mbar Yes 1 ms Note: sensor cables sold separately Note: The einstein Pressure kit is sold separately Data logging and analysis MiLAB 1. Take your einstein Tablet OR pair your einstein LabMate with your Android or ios tablet via Bluetooth 2. Insert the sensor cable into one of the sensor ports 3. Launch MiLAB 4. MiLAB will automatically detect the sensor and show it in the Launcher View 5. Make sure the icon next to the sensor is checked ( ) to enable it for logging

P r e s s u r e S e n s o r 3 6. Tap Setup to set the desired range and for calibration MiLAB Desktop 1. Pair your einstein LabMate with your PC, MAC, or Linux machine via Bluetooth, or connect it via the USB cable (found in the einstein LabMate box). 2. Insert the sensor cable into one of the sensor ports 3. Launch MiLAB Desktop 4. MiLAB Desktop will automatically detect the sensor and show it in the Current Setup Summary window 5. Click Full Setup, located at the bottom of the Current Setup Summary window to program the data logger s sample rate, number of samples, units of measurement, and other options

P r e s s u r e S e n s o r 4 6. Click the Run button ( ) to start logging Calibration The Pressure sensor is shipped fully calibrated. For greater accuracy there is also a manual calibration process. Calibrating in MiLAB 1. Tap the Settings button next to the sensor s name 2. Tap Manual Calibration 3. Prepare an environment with a known pressure. Enter this known value in the Point 1, Real Reading field 4. Measure the pressure and wait for the readings to stabilize. 5. Tap the Lock icon 6. Measure a second environment with a known value. Enter this known value in the Point 2, Real Reading field 7. Measure the pressure and, wait for the readings to stabilize. 8. Tap the Lock icon 9. Tap Calibrate. Note: For the most accurate results try to calibrate the sensor with one Real Reading under the expected results and one Real Reading over the expected results.

P r e s s u r e S e n s o r 5 Calibrating in MiLAB Desktop Two Point Calibration 1. Go to the Full Setup window and in the Calibrate column click Set 2. The Calibration window will appear 10. Prepare an environment with a known pressure. Enter this known value in the Point 1, Real Reading field 11. Measure the pressure and wait for the readings to stabilize. 12. Click the Lock icon 13. Measure a second environment with a known value. Enter this known value in the Point 2, Real Reading field 14. Measure the pressure and, wait for the readings to stabilize. 15. Click the Lock icon 16. Tap Calibrate. Note: For the most accurate results try to calibrate the sensor with one Real Reading under the expected results and one Real Reading over the expected results. An Example of using the Pressure Sensor Boyle's Law One of the distinguishing features of gases is their ability to be compressed into much smaller volumes. According to Boyle s Law, the volume of a sample of gas at a given temperature varies inversely with the applied pressure: P 1/V. In this experiment we investigate the relationship between pressure and volume, by measuring the effects of changes in air volume in a sealed flask at a constant temperature. 1. Connect the Pressure sensor to your einstein device 2. Attach the Pressure sensor to a syringe (with the plunger down to 1 cm above the bottom) 3. Start MiLAB 4. Select Run 5. Slowly pull back on the plunger 6. Your graph should be similar to the one below

P r e s s u r e S e n s o r 6 Troubleshooting If the Pressure sensor isn't automatically recognized by MiLAB, please contact Fourier Education's technical support. Technical support For technical support, you can contact the Fourier Education's technical support team at: Web: /support Email: support@fourieredu.com Phone (in the US): (877) 266-4066 Copyright and Warranty All standard Fourier Systems sensors carry a one (1) year warranty, which states that for a period of twelve months after the date of delivery to you, it will be substantially free from significant defects in materials and workmanship. This warranty does not cover breakage of the product caused by misuse or abuse. This warranty does not cover Fourier Systems consumables such as electrodes, batteries, EKG stickers, cuvettes and storage solutions or buffers. Fourier Systems Ltd. All rights reserved. Fourier Systems Ltd. logos and all other Fourier product or service names are registered trademarks or trademarks of Fourier Systems. All other registered trademarks or trademarks belong to their respective companies. ALBERT EINSTEIN and EINSTEIN are either trademarks or registered trademarks of The Hebrew University of Jerusalem. Represented exclusively by GreenLight. Official licensed merchandise. Website: einstein.biz