USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

Similar documents
USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Safety instructions and operating manual

R E D I C O N T R O L S

NGN Series nitrogen generator

200 PSI COMPRESSORS - MODEL NUMBERS

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

100C Air Compressor Kit

IMPORTANT SAFETY INSTRUCTIONS

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

SPECIFICATIONS ATTENTION

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

400C & 450C DUAL PERFORMANCE VALUE PACKS

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

444C DUAL PERFORMANCE VALUE PACK

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

KJ1000 Operating Instructions & Parts Manual NSN

LSX Low Smoke Convertor Operations Manual

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

5 Channel Calibrator

KJ4000 Operating Instructions & Parts Manual NSN

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Columbus Instruments

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

Workhorse-15 Oxygen Generator

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

92831 TEL: (714) FAX:

HZ-300 HAZER MACHINE USER MANUAL. Congratulations on the purchase of your new ANTARI HZ-300 Haze Machine.

IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION GUIDE Gas Rangetops

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

Operating Manual. Model BAC-30RT30/BAC-30DC

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

480C DUAL PERFORMANCE VALUE PACK

TECHNICAL INFORMATION

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S02

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

92831 TEL: (714) FAX:

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

RAM 4021 Operation Manual

MODEL 100 NITROGEN INFLATION CART

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Eastwood Versa-Cut Plasma Cutting System

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Instruction Manual for Configura Cushionair Portable Pump

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

Operating manual for Material pressure tanks Vol./1 and Vol./2

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

accidents which arise due to non-observance of these instructions and the safety information herein.

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Digital Vacuum Regulator

SILENTAIRE TECHNOLOGY

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

MANUAL. Sesame. Thermoplastic Tank Technologies

Model ASSEMBLY and OPERATING INSTRUCTIONS

Protocol Switchover Station

SPECIFICATIONS APCEPH1

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

In Vivo Scientific, LLC INSTRUCTION MANUAL

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

PurgEx. X Purge Controller N Version. User s Manual

MODEL NUMBER: AS18-2 USER GUIDE

CAUTION: YOU MUST READ THE FOLLOWING BEFORE OPERATING THE SNOWMAN.

Autocalibration Systems For In Situ Oxygen Analyzers

PRC CO ² -LASER PRESENTATION

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

NGP-250/500 Nitrogen Generator Quick Start Guide

Mass Flow Controller (MFC) for Gases

OPERATION MANUAL BFX-2

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

Supplementary Operator s Manual 42/24-14 EN Rev. 3

HAS2400 Hepa Air Scrubber

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

Nitrogen Supply System

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Agilent Auxiliary Gas Module AGM 2. User s Guide

Vapotherm Q50 Compressor. Instructions for Use

Transcription:

ATMOSPHERE APS Series Haze Generator MAX APS Series Fog Generator USER GUIDE No: 120815, Revision A/d MADE IN CANADA FABRIQUÉ AU CANADA Les Générateurs de Brouillard Ltée / Fog Generators Ltd 10301 avenue Pelletier, Montréal, Québec, Canada H1H 3R2 Tel. 514-272-6040 / 800-663-3020 - Fax 514-722-3229 www.mdgfog.com e-mail : info@mdgfog.com

Intentionally left blank User Guide120815, Rev: A/d, November 2016 2 / 15

INTRODUCTION Congratulations! You are now in possession of a MAX Fog Generator series and/or a ATMOSPHERE Haze Generator series. We hope it will bring you long hours of satisfaction. This product is available in many versions to satisfy the needs of our professional users. Please read the following instructions carefully and completely before filling your generator with fog fluid and turning it on. CAUTION This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. CAUTION If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. User Guide120815, Rev: A/d, November 2016 3 / 15

BASIC DESCRIPTION The MAX APS and ATMOSPHERE APS Series as well as their H.O. / TOURING APS Versions were designed with safety and reliability in mind. They are capable of generating pure white fog or haze for as long as you want (100% duty cycle). Those generators are also equipped, as a standard feature, with the Automatic Purging System TM (APS TM ). This system purges the heating module(s) after the first heating cycle and after every emission of fog preventing residual build up and clogging. The MAX APS and MAX APS H.O. / TOURING APS Series are variable output Fog Generators capable of generating large volumes of very dense fog in a short period of time. They are one of the quietest units on the market. The ATMOSPHERE APS and ATMOSPHERE APS H.O. / TOURING Series are non-stop haze generators capable of creating the finest and almost invisible mist. They highly emphasize laser and light beams. They also feature variable output. At the heart of the Generators is an electronic assembly that keeps the heating module(s) at a very stable temperature which integrates three types of fail-safe systems. Those three types of electronic fail-safe systems are designed to protect against over and under-heating conditions and, against component failure. A fourth safety system consists of a pressure relief valve which limits the working pressure and protects against over-pressure. The temperature is maintained within a narrow margin (the HEAT yellow LED turn on & off from time to time to indicate the control of temperature) otherwise, an error condition will result and the Fog Generator will shut down. When one of the safety systems is activated, the HEAT yellow LED will start blinking indicating the fail mode. Shut down the main power switch, wait 3 to 4 minutes and retry the generator. If the fail mode still appears, unplug your generator and return it to an authorized service center for verification. The FOG ON signal (green LED) can be applied to produce fog / haze for as long as the ready level is reached and all other control parameters are within specifications. When the FOG ON signal is removed, the APS TM cycle is automatically initiated to clear the heating module(s). Never remove the power to a generator while it is producing fog See the shut down procedures. The 100% Duty cycle is continuous with specified line voltage, and will degrade with line voltage loss. If that is the case, it can be compensated by reducing maximum operating pressure. User Guide120815, Rev: A/d, November 2016 4 / 15

Haze fluid reservoir Handle Haze output nozzle Fog fluid reservoir Downward Fan Fog output nozzle Detacheable standard remote control See next page Main Power Switch CO 2 Gas inlet VAC Input 50/60 Hz 115 or 230 V User Guide120815, Rev: A/d, November 2016 5 / 15

Green LED indicates that the Generator is READY to operate XLR-5 Remote Control Connector HEAT yellow LED indicator 1) The LED turns on and off from time to time to indicate the control of temperature. 2) The LED will start blinking if FAIL occurs. Fog switch with a Green LED indicator Power switch with the Red LED Standard remote control (Background color is purple for ATMOSPHERE APS, and gray for MAX APS ) User Guide120815, Rev: A/d, November 2016 6 / 15

OPERATING INSTRUCTIONS The Fog Generators are quite easy to operate and require no preventive maintenance. They are supplied with a removable remote control. A DMX Interface can be bought as an option. When the MAIN POWER (115 or 230 VAC) and the MAIN POWER SWITCH is applied, the generator is placed in stand-by mode. When in stand-by mode, most of the electronic controls are off (except for the three types of fail-safe systems), waiting for the ON switch on the remote control to be activated. When the ON switch is pressed, the red LED indicating that the unit is working will light up, as well as the yellow LED called HEAT, indicating the start of the heating cycle which will last approximately 10 minutes. When the temperature reaches a pre-adjusted level called the READY level (indicated by a green LED), the HEAT yellow LED will turn off. The Automatic Purging System TM (APS TM ) will be automatically initiated. After the first purging cycle is completed (approx. time 30 to 60 sec.) the generator is ready to produce fog. The amount of the fog / haze emission can be controlled by adjusting the working pressure of the CO 2 gas regulator. When an overheating condition is detected, or if the internal temperature reaches 60 C (140 F), a safety circuit is triggered. This circuit removes the power to the heating elements, preventing hazardous conditions. When an under-heating condition occurs, the generator will stop producing fog until the temperature of the heating module is back within parameters. User Guide120815, Rev: A/d, November 2016 7 / 15

SETTING UP WARNING: Do not operate at less than 2 meters (6.5 ft.) from people. The ATMOSPHERE APS Series requires 1 m (3.28 ft) of clearance below the fan. Never install above people. When not in use ALWAYS switch OFF the power switch located on the back panel, or unplug the generator. Install the Fog Generator away from rain, wind, heavy dust or any harsh environment situations. These Fog Generators must be installed in an upright position on a stable and level surface. Ensure available space for all electrical cable and gas tubing runs, Use in a well ventilated area. The Generators are quite easy to operate and require no preventive maintenance. Fill the reservoir with Fog Fluid (see FILLING THE FLUID RESERVOIR paragraph). Connect the power cord 115 or 230 VAC, 50-60 Hz (see Table for Wattage) Connect the gas inlet to a gas bottle equipped with a single or double stage regulator. The gas inlet is an Oxygen Adaptor (9/16-18 R.H). Open the gas bottle, and set the regulator to the operating pressure. The maximum operating pressure is defined as below: ATMOSPHERE APS ATMOSPHERE APS H.O. / TOURING MAX 3000 APS & MAX 5000 APS MAX 5000 APS H.O. / TOURING 138 kpa / 1.38 bar / 20 psi, 207 kpa / 2.07 bar / 30 psi, 276 kpa / 2.76 bar / 40 psi, 414 kpa / 4.14 bar / 60 psi, Switch ON the main Power switch. Press the Power switch on the remote control, a red LED will turn on. Then a yellow LED will turn ON indicating HEAT ON. Wait 8 to 10 minutes until the green Ready LED turns ON. User Guide120815, Rev: A/d, November 2016 8 / 15

After the first purging cycle is completed (approx. time 30 to 60 sec.) the generator is ready to operate. Press the Fog switch to produce Haze or Fog. The CO 2 gases are used as a propellant when generating Fog / Haze. Output pressure can be adjusted by mean of the CO 2 gas regulator. The ideal range for MAX APS Series is 10 to 40 psi. and the H.O. / TOURING APS Version is 10 to 60 psi., for the ATMOSPHERE APS Series it is 5 to 20 psi. and the H.O. / TOURING APS Version is 5 to 30 psi. Press again the Fog switch to stop to produce Haze or Fog. The APS TM cycle is then automatically initiated to clear the heating module(s). SHUT DOWN PROCEDURE A Fog Generator must never be shut down while making Fog. To power OFF a Generator, the following sequence must be observed: Always turn OFF the fog emission, Wait a minimum of 1 minute for the purge cycle to complete. If possible avoid purging at very low pressure which reduces the efficiency of the Automatic Purging System TM. The recommended minimum final purging pressure is 10 psi. Power OFF the Fog Generator (by switching off the MAIN POWER SWITCH or by removing the MAIN POWER. User Guide120815, Rev: A/d, November 2016 9 / 15

FILLING OF THE FLUID RESERVOIR WARNING Use only Fog Fluid. Not doing so, will void the warranty and may damage the generator. CAUTION DISCONNECT UNIT BEFORE ADDING FOG FLUID AND WAIT COUPLE OF MINUTES TO BE SURE THE RESERVOIR IS FULLY DEPRESSURIZED. Unscrew the brass closure and pour the Fog Fluid until it reaches the inside bottom of the opening. Avoid overfilling. Screw back the closure and make sure it is tightened. GAS REQUIREMENTS WARNING In the European Community the gas cylinder and regulator must be compliant with the Pressure Vessel Directive. In North America the gas cylinder must be manufactured, inspected and tested in accordance with U.S. Department of Transportation (DOT) 3AL and Transport Canada (TC) 3ALM requirements. WARNING The CO 2 gas regulator and the N 2 regulator do not use the same thread to mate with the cylinder. Make sure to use a CO 2 gas regulator with the CO 2 gas cylinder and to use a N 2 gas regulator with the N 2 cylinder. CAUTION WARNING Only use industrial grade Carbon Dioxide gas (CO 2 ) or industrial grade Nitrogen gas (N 2 ). To prevent gas leak and drop of pressure, ALWAYS use a neoprene washer when connecting the regulator to the cylinder User Guide120815, Rev: A/d, November 2016 10 / 15

OPTIONAL ACCESSORIES 2 Channel DMX Interface Remote Control Timer PLC Interface Flight cases Portability Option ATMOSPHERE APS, MAX 3000 APS ATMOSPHERE APS H.O., MAX 5000 APS User Guide120815, Rev: A/d, November 2016 11 / 15

Electrical TECHNICAL SPECIFICATIONS ATMOSPHERE APS ATMOSPHERE APS H.O. MAX 3000 APS APS MAX 5000APS MAX 5000 H.O. Voltage - VAC 115 230 115 230 115 230 115 230 230 Frequency - Hz 50-60 50-60 50-60 50-60 50-60 50-60 50-60 50-60 50-60 NB of phase 1 1 1 1 1 1 1 1 1 Watts 715 715 1415 1415 715 715 1415 1415 2815 Amp. 6,2 3,2 12,3 6,2 6,2 3,2 12,3 6,2 12,3 FLUID Type M.S.D.S. available on request Reservoir size litre (US gal.) 2,5 (0.66) 2,5 (0.66) 6,5 (1.72) 6,5 (1.72) 2,5 (0.66) 2,5 (0.66) 2,5 (0.66) 2,5 (0.66) 6,5 (1.72) Consumption in litre (US oz) per hour @ 138 kpa / 1,38 bar / 20 psi 0,055 (1.85) 0,055 (1.85) @ 207 kpa / 2.07 bar / 30 psi 0,11 (3.7) 0,11 (3.7) - - - @ 276 kpa / 2,76 bar / 40 psi - - - - 1 (34) 1 (34) 2,6 (88) 2,6 (88) @ 414 kpa / 4.14 bar / 60 psi - - - - - - - - 4,5 (120) GAS Type (industrial grade quality) CO 2 CO 2 CO 2 CO 2 CO 2 CO 2 CO 2 CO 2 N 2 Only Consumption in kg (Lb) per hour @ 138 kpa / 1,38 bar / 20 psi 0,18 (.4) 0,18 (.4) - - - - - - - @ 207 kpa / 2.07 bar / 30 psi - - 0,36 (0.8) 0,36 (0.8) - - - - - @ 276 kpa / 2,76 bar / 40 psi - - - - 0,97 (2.13) 0,97 (2.13) 2,25 (5) 2,25 (5) - @ 414 kpa / 4.14 bar / 60 psi - - - - - - - - 5 (11) OUTPUT Fog volume in m 3 (ft 3 ) per min. @ 276 kpa / 2,76 bar / 40 psi - - - - 85 (3 000) 85 (3 000) 218 (7680) 218 (7680) 445 (15750) Total running time in hour @ 138 kpa / 1,38 bar / 20 psi 45 45 60 60 - - - - - Color Pure white Pure white Pure white Pure white Pure white Pure white Pure white Pure white Pure white Particle size in microns 0,5 0,7 0,5 0,7 0,5 0,7 0,5 0,7 0,5 0,7 0,5 0,7 0,5 0,7 0,5 0,7 0,5 0,7 User Guide120815, Rev: A/d 12 / 15

WARRANTY When installed and operated as recommended, Fog Generators Ltd., guarantees that this product will remain free of defects in parts and labor for a period of five (5) years from the moment it is delivered. This warranty does not apply if the product has been modified without our written authorization, or repaired without a written authorization from or one of is authorized service center, or if it is used under conditions for which it has not been designed, or if a none Fog Fluid has been used. Fog Generators Ltd is not responsible for any damages resulting from a faulty installation or from abusive use of the product. If any device is found unsatisfactory under the terms of this warranty, Fog Generators Ltd will repair or replace it free of all charges except transportation costs. This warranty applies only to the product itself and Fog Generators Ltd declines responsibility for any losses, costs, or damages resulting from its use. Fog Generators Ltd shall not be liable for consequential damage in case of any failure to meet the conditions of any warranty or shipping schedule, nor will claims for labor, loss of profits, repairs, or other expenses incidental to replacement be allowed. The repair or replacement of the product, by Fog Generators Ltd shall constitute fulfillment of all obligations to the purchaser. No other guarantees or warranties, expressed or implied, are made by Fog Generators Ltd in connection with its products. This warranty is nontransferable and applies to the original purchaser only. To obtain satisfaction under the terms of this warranty, contact your local sales office, and we will be pleased to help you. User Guide120815, Rev: A/d 13 / 15

DECLARATION OF CONFORMITY User Guide120815, Rev: A/d 14 / 15

NOTE User Guide120815, Rev: A/d 15 / 15