PL475. Patient Lift Scale. Owner's Manual

Similar documents
All Purpose AP-Series Operation Manual

AIR/OVER HYDRAULIC JACK 20 TON

SAFETY SUMMARY SAFETY SUMMARY

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

MODEL SWH10 1,000 LB CAPACITY SWIVEL HOIST

STAND AID 1600/ ECONOSTAND

Use this key to determine which sections of this Product Manual apply to your job.

OPERATOR'S MANUAL. TOTALIFT - II LATERAL TRANSFER / TRANSPORT CHAIR Model No R02 AN

User Manual GRI- 1500Li

Operator s Manual. All-Terrain Wheelchair

30T A/Manual Hydraulic Shop Press

Mini Pod Press. #78H-M2 Mini Pod Press Manual-R1

OPERATING INSTRUCTIONS. Parts List N. Note: Owner and operator MUST read and understand this operating instructions before use this lift table.

User Instruction Manual For Davit Rescue System

EZ Way Light Stand. Operator s Instructions. 300 lb. Capacity

Index Table. Model 794. Installation, Operating and Maintenance Instructions

Tru Trak Sulky Proline Mid Size Mower Attachment

contents introduction

DBI SALA Confined Space Rescue Davit System

HYDRAULIC MOBILE LIFTING TABLE

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Stand Up Patient Lift RPS350-2

SAVE THESE INSTRUCTIONS. NOTE: Check all parts for shipping damage. In case of damage, DO NOT use. Contact Carrier/Invacare for further instructions.

SASK-A-POLE OWNERS AND USERS MANUAL

20 Ton SD Shop Press Operating Instructions

SET-UP OPERATION MAINTENANCE SERVICE TROUBLESHOOTING WARRANTY BY MOJACK DISTRIBUTORS, LLC. Item #65401 WARNING

Invacare Reliant 450 RHL450-1 Invacare Reliant 450 RPL450-1 Invacare Reliant 600 RPL600-1

USER MANUAL

Operation Manual Guillotine Cutter RC-5

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Installation and Service Manual

222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions

WBM Installation Manual KAT Master Hitch

1.0 - OPENING AND CLOSING THE DOOR

Pectoral Machine. User manual E S S E N T I A L S T R E N G T H

EZee Glider Manual. Tools needed for Assembly: Wrench (included) Philips Screwdriver (not included) Assembly Instructions

OPERATOR S MANUAL SPREADER. CSS, VNQ [For Combine Harvester AW82V] Original instructions

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

Baseball Pitching Machine

CP10K. 10,000 lb. Cable Puller Instruction Sheet. SAFETY ISSUES

Owner s Manual. for. Manual Reel Mower. (Model MM-1)

Yoke Block Instruction Manual

Owner s Manual. for. NaturCut. Model CLASSIC HD

Manual Actuated Boiler Blowdown Valves

This section provides general information and recommendations required prior to installing, operating or maintaining your KAT Master Hitch.

CLASS CYCLE P8000 OWNER'S MANUAL JOHNSON HEALTH TECH. CO., LTD.

WARNINGS. Do not mix alkaline, standard (carbon-zinc), or rechargeable (Ni-Cd, Ni-MH, etc) batteries.

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike

Cascade Patient Transfer Lift System Safe Operation & Daily Maintenance Instructions

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

VL 2K LIFT D-L WINCH INSTRUCTIONS (Applies to P/Ns , , , , , )

Invacare I-Lift ILIFTHM, ILIFTEM, ILIFTEE. EN Portable Patient Lift User Manual...3

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

3 Post Pressure Fit System Owner s Manual

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

walk with independence

3/8" Dr. Air Butterfly Impact Wrench

Stand Up Patient Lift RPS350-2

GCI CYLINDER INVERTER

ModelsEZU-15 & EZU-15-R. BISHAMON INDUSTRIES CORPORATION 5651 East Francis Street Ontario, California 91761, USA (909) (800)

Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves

Specifications Testing & Adjusting Disassembly & Assembly

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

OPERATIONS/PARTS MANUAL FOR PATTERSON'S WWP50-H-14 HYDRAULIC WINCH.

75 Ton SD Shop Press Operating Instructions

You have decided to buy an LP 10 E by STEYR SPORTWAFFEN the new dimension of match air pistols!

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

Marine 6-Boat Free-Standing Racks SKU: Updated November 2011

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 3K Puller (M3K-M)

! Warning, refer to accompanying documents.

Owner s Manual. Model H4685

User Manual GRX- 1250Li

DelVal Flow Controls Private limited

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

All rights reserved 2010 Les Fabrications TJD inc.

USER GUIDE ROLLING WALKERS INSTRUCTIONS FOR USE JANUARY, Maximum User Weight: 170kg (Do not exceed this weight)

Pressure Fit System - Two Post Version Owner s Manual

Tube-Line Accelerator Spinner Kit

POWER ASSISTED BICYCLES OWNERS MANUAL

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Air Tractor Preventative Maintenance Manual And Troubleshooting

OPERATIONS/PARTS MANUAL FOR PATTERSON'S WWP75H-10 HYDRAULIC WINCH.

44in Side Discharge Mower for Wheel Horse XL 440H Lawn Tractors Model No Serial No and Up

Please Do Not Return This Product To The Store!

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

airplaine kite Model assembly & Operating Instructions Important: If damage is caused due to a crash; your warranty is void.

Owner s Manual

Installation, Operation & Maintenance Manual

Mini Glider Manual. Your Glider comes partially assembled. The front wheel and the handlebars require assembly.

BELT DRIVE INDOOR CYCLING BIKE SF-B1712

C - SERIES. Height Adjustable Portable Goal Supports. Installation & Owner s Instructions C1000 C2000. Made in the USA

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

Operator's Manual Supplement

U.S. Patent No. 7,922,246. Patents Pending

Transcription:

PL475 Patient Lift Scale Owner's Manual CARDINAL SCALE MFG. CO. 0046-M496-O1 Rev A PO BOX 151 WEBB CITY, MO 64870 Printed in USA 11/99 PH 417-673-4631 FAX 417-673-5001

2

Thank you for purchasing our DETECTO Model PL475 Patient Lift Scale. It has been manufactured with quality and reliability at our factory in Webb City, MO USA. This scale has been tested before leaving our factory to insure accuracy and dependability for years to come. When removing the unit from its packing, inspect it for signs of damage, such as exterior dents and scratches. Keep the carton and packing material for return shipment if it should become necessary. It is the responsibility of the purchaser to file all claims for any damages or loss incurred during transit, unless this responsibility has been accepted by the seller in its proposal. This manual is provided to guide you through operation and maintenance of your Patient Lift Scale. Please read it thoroughly before attempting to install or operate your PL475 and keep it handy for future reference. ÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜ FCC COMPLIANCE STATEMENT WARNING! This equipment generates, uses and can radiate radio frequency and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the interference. You may find the booklet "How to Identify and Resolve Radio TV Interference Problems" prepared by the Federal Communications Commission helpful. It is available from the U.S. Government Printing Office, Washington, D.C. 20402. Stock No. 001-000-00315-4. ÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜ All rights reserved. Reproduction or use, without expressed written permission, of editorial or pictorial content, in any manner, is prohibited. No patent liability is assumed with respect to the use of the information contained herein. While every precaution has been taken in the preparation of this manual, the Seller assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from use of the information contained herein. All instructions and diagrams have been checked for accuracy and ease of application; however, success and safety in working with tools depend to a great extent upon the individual accuracy, skill and caution. For this reason the Seller is not able to guarantee the result of any procedure contained herein. Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures. Persons engaging the procedures do so entirely at their own risk. TABLE OF CONTENTS Specifications... 1 Introduction... 2 Setup Instructions... 2 Transporting The Patient... 2 Weighing The Patient... 4 Component Identification... 5 Preventive Maintenance... 6 Service Information... 6 Service Hints... 6 Parts Identification... 7 INDICATOR Capacity: Resolution: Display: Power Requirements: Temperature Range: LIFT Casters: Lift Mechanism: Closed Overall Dimensions: Under bed clearance: Shipping Weight: SPECIFICATIONS 400 lbs (180 kg) 0.2 lb (0.1kg) LCD digital display 9.0 V Battery (included) 50 to 104 F (+10 to +40 C) Four (4); full swivel, rear pair locking Hydraulic 54"H x 22"W x 50"L (1.37m H x 0.56m W x 1.27m L) 4.8"H (122mm) 250 lbs (113kg) SERIAL NUMBER DATE OF PURCHASE PURCHASED FROM RETAIN THIS INFORMATION FOR FUTURE USE PRECAUTIONS Before using this instrument, read this manual and pay special attention to all "WARNING" symbols: IMPORTANT 1

INTRODUCTION The Detecto PL475 Patient Lift Scale is a complete 400 lb weighing solution that provides a fast, easy and efficient method of weighing a patient. The PL475 can easily be operated by one person. Through its use, patient repositioning within their room (e.g. from bed to wheelchair) and weighing time will be reduced to a minimum. Operation of the scale can be quickly learned using the following instructions and guidelines. WARNING - This product is not intended for use in transporting patients! It is to be used ONLY for repositioning a patient within the patient's room. Failure to observe this warning may result in serious injury to the patient and/or the lift operator. The Detecto PL475 Patient Lift Scale includes the PL400 indicator, which is a completely self-contained, battery-powered instrument that is used to determine the weight of a person suspended from the patient lift mechanism. The PL400 uses a single 9 volt Alkaline battery that is contained in a battery holder inside the instrument. Access is via a removable panel on the back of the indicator. The battery will power the indicator for months (depending on use) and has a low "BAT" indicator to alert the operator that the battery should be replaced. The canvas sling is machine washable using warm water and a mild detergent. Unpacking 1. Unpack and remove all packing material. 2. Check for damaged parts. SETUP INSTRUCTIONS 3. Install the battery in the indicator. Refer to the PL400 Owner's Manual, 8551-M912-O1, for additional information. 4. Turn on indicator to check battery charge. Purging Air From Hydraulic Cylinder Before using the lift, make sure no air is trapped in the hydraulic cylinder. This can be done by pressing down on the boom and letting go while the cylinder release valve is shut. A solid boom indicates no air is present. If the boom presses down and then springs up, the cylinder should be purged. Trapped air can result in an uncontrolled drop of a few inches while lowering the boom. To avoid trapping air, never raise the boom by hand. To purge the cylinder: 1. Turn the cylinder release valve clockwise to the fullest degree. Move the pump handle up and down slowly until the boom reaches its highest position. 2. Fully open the cylinder release valve counterclockwise, and push the boom down as far as it will go. Close the cylinder release valve, turning clockwise. 3. Raise the boom to the height at which it will be used by pumping the cylinder. Reference Figure No. 2 on page 5 for component identification. 2

From A Bed REPOSITIONING THE PATIENT 1. Carefully roll the patient on their side. Place the sling (with the attached straps toward their head) next to them in the bed and roll the patient back onto the sling. 2. Insert the (2) two white support bars into each side of the seat portion of the sling. See Figure No. 1. 3. Attach the lower support straps to sling by clipping the hooks into the hole in support bar. NOTE: Attach the hooks to the support bar so that the hook clip will be facing away from the patient when the sling is used. 4. Raise the boom to full height and wheel the lift to the patient's bedside. 5. Position lift so that the base is under the bed, and the sling support hoops are suspended directly over the patient. 6. Set the brakes on the rear wheels. 7. Widen the base stance. A. To adjust the base stance, face the rear of the lift and move the adjust handle towards the column. Figure No. 1 B. Rotate the handle until the base stance widens. C. Return the handle to a vertical position to engage the lock pin. D. To return the base to the narrow position, reverse the above procedure. 8. Turn the cylinder release valve counterclockwise to the open position. When the sling support hooks are low enough to engage the sling straps, return the release valve to the original position. 9. Attach sling to lift by engaging the sling support hooks in the appropriate straps of the sling. 10. After closing the release valve, move the pump handle up and down with slow strokes of even pressure until the patient is about an inch above the mattress. Make sure that no part of the patient or sling is touching any part of the bed or mattress. 11. Release the brakes on the rear wheels. The patient is now ready to be repositioned to a chair, wheelchair, bed or other structure. 12. To lower the patient, set the brakes on the rear wheels, then slowly open the release valve counterclockwise. 13. When the patient is in the chair, wheelchair or back on the bed, disengage the sling support hooks from the sling and remove the lift from the chair, wheelchair or bedside. 14. Remove the sling from under the patient. Upper Support Straps Lower Support Straps Support Bars From A Chair Or Wheelchair 1. Carefully lean the patient forward and place the sling (with the attached straps toward the patient's head) behind the patient. Slide the sling seat under the patient's posterior and return the patient to the sitting position. 2. Insert the (2) two white support bars into each side of the seat portion of the sling. See Figure No. 1. 3. Attach the lower support straps to the sling by clipping the hooks into the hole in support bar. NOTE: Attach the hooks to the support bar so that the hook clip will be facing away from the patient when the sling is used. 4. Raise the boom to full height and wheel the lift to the patient's chair or wheelchair. 3

REPOSITIONING THE PATIENT, Cont. From A Chair Or Wheelchair, Cont. 5. Widen the base stance. A. To adjust the base stance, face the rear of the lift and move the adjust handle towards the column. B. Rotate the handle until the base stance widens. C. Return the handle to a vertical position to engage the lock pin. D. To return the base to the narrow position, reverse the above procedure. 6. Position the lift so that the patient is facing the pivot adjust handle. The base is around the chair or wheelchair and the sling support hoops are suspended directly over the patient. 7. Set the brakes on the rear wheels. 8. Turn the cylinder release valve counterclockwise to the open position. When the sling support hoops are low enough (above the patient's lap) to engage the sling, return the release valve to the original position. 9. Attach sling to lift engaging the sling support hooks in the appropriate straps of the sling. 10. After closing the release valve, move the pump handle up and down with slow strokes of even pressure until the patient is about an inch above the chair or wheelchair. Make sure that no part of the patient or sling is touching any part of the chair or wheelchair. 11. Release the brakes on the rear wheels. The patient is now ready to be repositioned to a chair, wheelchair, bed or other structure. 12. To lower the patient, set the brakes on the rear wheels, then slowly open the release valve counterclockwise. 13. When the patient is in the chair, wheelchair or on the bed, disengage the sling support hooks from the sling and remove the lift from the chair, wheelchair or bedside. 14. Remove the sling from under the patient. From The Floor 1. Carefully roll the patient on their side. Place the sling (with the attached straps toward their head) next to them on the floor and roll the patient back onto the sling. 2. Insert the (2) two white support bars into each side of the seat portion of the sling. 3. Attach the lower support straps to the sling by clipping the hooks into the hole in support bar. NOTE: Attach the hooks to the support bar so that the hook clip will be facing away from the patient when the sling is used. 4. Widen the base stance. A. To adjust the base stance, face the rear of the lift and move the adjust handle towards the column. B. Rotate the handle until the base stance widens. C. Return the handle to a vertical position to engage the lock pin. D. To return the base to the narrow position, reverse the above procedure. 5. Raise the boom to full height and wheel the lift to the patient. 6. Position the lift so that the patient's legs are between the base with their feet towards the pivot adjust handle. Lift the patient's legs. Slide the lift forward, placing the patient's legs over the back of the lift base. Continue moving the lift forward until the sling support hoops are suspended directly over the patient. 7. Set the brakes on the rear wheels. 8. Turn the cylinder release valve counterclockwise to the open position. When the sling support hooks are low enough to engage the sling straps, return the release valve to the original position. 4

REPOSITIONING THE PATIENT, Cont. From A Chair Or Wheelchair, Cont. 9. Attach the sling to the lift by engaging the sling support hooks in the appropriate straps of the sling. 10. After closing the release valve, move the pump handle up and down with slow strokes of even pressure until the patient is a few inches above the floor. 11. Release the brakes on the rear wheels. The patient is now ready to be repositioned to a chair, wheelchair, bed or other structure. 12. To lower the patient, set the brakes on the rear wheels, then slowly open the release valve counterclockwise. 13. When the patient is in the chair, wheelchair or on the bed, disengage the sling support hooks from the sling and remove the lift from the chair, wheelchair or bedside. 14. Remove the sling from under the patient. COMPONENT IDENTIFICATION Boom Pump Handle Piston Cylinder Release Value PL400 Indicator Yoke Pivot Adjust Handle Hydraulic Pump Sling Support Hooks Base Assembly Locking Rear Caster Figure No. 2 5 Front Caster

WEIGHING THE PATIENT 1. Press the ON/ZERO key to turn the indicator on. If the the LOCK feature has been enabled, the unit will display the last weight reading stored by the device and the LOCK annunciator will be on. Otherwise, the unit will display the current weight. 2. To clear the last weight reading stored, press the ON/ZERO key. The unit will then display the current weight. 3. Press the ON/ZERO key again to zero the display. 4. The patient is placed in the sling and lifted from the bed, chair (wheelchair) or floor. 5. When weight is stable, the STABLE annunciator will turn on. 6. If the Auto-Shutoff feature has been enabled, the unit will turn itself off after a stable weight reading is displayed for the preset time. Refer to the PL400 Owner's Manual, 8551-M912-O1, for additional information. 7. If the unit turns off before the patient was properly weighed, it can be turned on again by pressing the ON/ZERO key as described in steps 1 and 2. PREVENTIVE MAINTENANCE The information presented below can save you time and trouble, and if adhered to, will prolong the service and life of the Patient Lift Scale. 1. Do not lift the boom by hand. Use only the pump. 2. A small amount of oil will accumulate around the piston from time to time. This should be wiped away as needed. 3. Casters and axle bolts require inspection every sixty (60) days to be sure that the axle nuts are tight and that the casters swivel and roll smoothly. A light grease may be applied to the ball bearing swivel of the casters once a year, or more frequently if the casters are exposed to extreme moisture conditions. 4. The hydraulic pump is sealed at the factory. If service is ever required, the pump unit must be returned to the factory for repair. This is seldom necessary, but after many years of service, the seals may require a replacement. Please do not attempt to open the hydraulic pump to obtain local service, as this will void the guarantee, and might result in damage and costly repair. 5. Check that the U-bolt is securely fastened to the boom assembly. IMPORTANT! Periodically check and tighten all bolted connections. Failure to maintain tightness of bolted connections may result in injury to the patient and/or lift operator. SERVICE INFORMATION In the event that factory repairs are required, call the factory for service authorization. It is suggested that the inoperative Patient Lift Scale be tagged with as much information as possible regarding the nature of the problem. Refer to the Owner's Manual, 8551-M912-O1 for questions regarding the PL400 digital indicator. PROBLEM Weights grossly inaccurate. Display does not illuminate, or turns off soon after being turned on. Weight reading does not change when applying weight to sling or force to ends of support hoops. Instrument reading drifts randomly. Certain segments of display do not illuminate. Display is "locked up" - either over range or underrange. SOLUTION Make sure patient is centered in sling. Battery may be discharged. Replace. Instrument is defective. Call factory for assistance. Call factory for assistance. Call factory for assistance. This is usually due to weight transducer or cable malfunction, and is difficult to resolve without special equipment. Call factory for assistance. 6

PARTS IDENTIFICATION 1 3 11 7 6 8 10 12 9 4 2 5 Figure No. 3 ITEM PART NO. QTY DESCRIPTION 1 0046-B446-0A 1 U-BOLT SLEEVE ASSEMBLY 2 0046-D401-0A 1 BASE ASSEMBLY 3 0046-D402-0A 1 BOOM / MAST CLYINDER ASSEMBLY 4 6540-1133 2 REAR CASTER (LOCKING) 5 6540-1134 2 FRONT CASTER 6 6540-1119 1 HYDRAULIC CLYINDER ASSEMBLY 7 8551-D907-OA 1 PL400 INDICATOR 8 0046-C476-08 1 PATIENT LIFT SLING 9 0046-B494-08 2 SLING SUPPORT BAR 10 0046-C493-08 2 SLING SUPPORT STRAP (LOWER) 11 0046-D472-0A 1 YOKE ASSEMBLY 12 6028-0021 2 CARABINER LINK 7

2

2

MANU & ED N SIG DE FACT U RED. I N U. S A.