Axial piston pumps type PVC

Similar documents
Axial piston pumps type PVC

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Variable Displacement Pump A10VO

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Fixed Displacement Motor A4FM

Priority (Swing) Motors Data and Specifications

Fixed Displacement Plug-In Motor A2FE

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

Fixed Displacement Motor A4FM

Leak free Pipe Rupture Valve for Excavators

Controllers DR, DP, FR and DFR

Axial Piston Variable Pump A10V(S)O (US-Version)

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

Brueninghaus Hydromatik Rexroth A11VLO pump and A11VO pump

PVQ 13 A2 R SE 1 S 20 C-11 D

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description

Proportional Throttle Cartridges, Size 16

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

PLD 03 T A CASAPPA S.p.A.

Flow divider designs MTL

OMS Technical Information. Versions OMS. Versions

Pressure reducing valve, pilot operated, Model 3DR

Monoblock Directional Control Valve RMB 202

Variable displacement vane pump (with mechanical pressure compensator)

GEAR PUMPS. Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 RPM

PVK OPEN LOOP PUMPS. Bulletin E

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

3-Way Pressure-Reducing Cartridge, Size 2 4

OMS Technical Information Technical data

Axial piston-variable motor A10VM Plug-in version A10VE

Directional Controls

RP series Rotor Pumps

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

DENISON HYDRAULICS T6 industrial application

Industrial Hydraulic Pumps T6EDC. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement

2-way flow control valve Model 2FRM 6

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Electrically Operated Pressure-Relief Cartridge, Size 10

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

CALEFFI. Ball zone valves. series /03 GB

Liquid ring compressors

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4

420 Mobile Piston Pump Design Code B

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

DENISON HYDRAULICS high performance hydraulic vane pumps single, double, triple T7 and T67 industrial application

-for information only- noncommittal. Axial Piston Variable Pump A10VSO RA / /24. Technical Data Sheet

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proper Pump Installation Practices

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

Inverse Proportional Pressure-Relief Cartridge, Size 10

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

OMS, OMT and OMV Orbital Motors. Technical Information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Pressure reducing valve, pilot operated

Air preparation units

Inverse Prop. Pressure-Relief Cart., Size 2 4

Cooler-Bypass Thermostat Valve, Size 16

Orbital Motors Type OMP X and OMR X

Pilot Operated Check Valves

Damcos PHP Portable hand pump unit 5 l. Product Data Sheet September 2014 SD E04

Axial piston variable motor A10VM Plug-in version A10VE

HYDRAULIC MOTORS MV APPLICATION GENERAL

ALF400 to 900, ALT-5/-9

Size 6 up to 31.5MPa 1) up to 25 L/min

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Pressure-Relief Cartridge Valve, Size 4

Displacement. from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL

SIHI LPH-X - Liquid Ring Compressors

Technical Data Sheet TI-F50 Locking Units series KFH

directional control valve series cv691

Hand & mechanical directional valves

Electro-hydraulic Proportional Flow and Direction Control Valve

Intrinsically safe solenoid valves on/off controls - ATEX certification

Hydraulic Reliability & Preventive Maintenance Report

SDM to 8 sections monoblock valve D1WWDA02A

Orbital Motors Type OMP, OMR and OMH. Technical Information

Proportional Directional Valve System

Transcription:

www.atos.com Table TA16-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low noise level, suitable for open circuit systems. They are available with following hydraulics controls (see section ): A: mechanical pressure compensator with manual adjustment GM: compensator with ISO 4401 size 06 mounting surface with P and T connections. This solution allows different type of controls, like multiple pressure selection, venting, etc. which can be realized by installing proper control valves (to be separately ordered), see sections and HL: load sensing compensator PV-A Mounting flange with 2 holes and in additional interface with 4 holes Max displacement: 23 cm 3 /rev. Max pressure: 210 bar 1 MODEL ODE PV - * A 4 R - 40 - Variable displacement axial piston pump - = STD 1012 viton = Viton seals Displacement: = cm 3 /rev 23 = 23 cm 3 /rev Type of control (see section ): A = manual pressure compensator GM = manual pressure compensator, with mounting surface size 06 for venting or remote pressure control (valve to be ordered separately) HL = load sensing (pressure & flow) 40 = oil ports with SPP (Gas) threaded connection Pressure regulation range: 4 = 20 20 bar Direction of rotation (viewed at the shaft end): R = clockwise 2 OPERATG HARATERISTIS Pump model PV- PV-23 Displacement [cm 3 /rev],0 23,0 Theoretical max flow at 140 rpm [l/min] 21,7 33,0 Max working pressure [bar] 210 Min inlet pressure [bar abs.] 0,8 Max pressure on drain port [bar abs.] 1,4 Power consumption at 140 rpm and at maximum pressure and displacement [kw] 11 17 Max drain flow [l/min] 1. Speed rating [rpm] 00 1800 TA16

A 3 MA HARATERISTIS Installation position Ambient temperature Any position. The drain port must be on the top of the pump. ain line must be separated and unrestricted to the reservoir and extended below the oil level as far from the inlet as possible. Suggested maximum line lenght is 3 m. from -10 to +70 Fluid Hydraulic oil as per D 24...3; Recommended viscosity Fluid contamination class Fluid temperature 100 mm 2 /sec at 40 (ISO VG 100). Maximum start-up viscosity: 800 mm 2 /sec ISO 19/17/14 ISO4406 (class 9 NAS1638) +20 +60 (+0 +80 with viton seal) 4 STALLATION POSITION VERTIAL STALLATION... A The pump is supplyed whit drain open, and oil filling port plugged. efore installation fill the pump with hydraulic oil through port for at least 3/4 of its volume, keeping it in horizontal position. With exception of pump mounted below the oil level, we recomend to interpose a baffle plate between inlet and drain line. SIDE THE TANK Minimum oil level equal or above the pump mounting surface. A 200mm HORIZONTAL STALLATION SIDE THE TANK Minimum oil level below the pump mounting surface. Minimum inlet pressure = 0,8 bar absolute 800mm, = 200mm SIDE THE TANK, above oil level Minimum inlet pressure = 0,8 bar absolute 800mm, = 200mm SIDE THE TANK Minimum oil level equal or above the pump mounting surface. A 200mm SIDE THE TANK SIDE THE TANK, above oil level Minimum oil level below the pump mounting surface. 800mm, = 200mm Minimum inlet pressure = 0,8 bar (absolute) Minimum inlet pressure = 0,8 bar (absolute) 800mm, = 200mm SIDE THE TANK, below oil level = 200mm : inlet line - : drain line - A: minimum distance between inlet and drain line - +: permissible suction height - : inlet line immersion depth DIAGRAMS at 140 rpm (based on mineral oil ISO VG 46 at 0 ) Noise level curves Ambient noise levels measured in compliance with ISO 4412-1 oleohydraulics -Test procedure to define the ambient noise level - Pumps Shaft speed: 140 rpm. = Qmax = Qmin PV- PV-23 Noise level (d) Noise level (d) Operating pressure (bar) Operating pressure (bar)

6 HYAULI AND ELETROHYAULI ONTROLS A Manual pressure compensator The pump displacement decreases when the line pressure approaches the setting pressure of the compensator. The pump supplies only the fluid required by the system. Pressure may be steplessly adjusted at the pilot valve. ompensator setting range: 20 210 bar ompensator standard setting: 140 bar Flow [l/min] Hysteresis and pressure increasing; max 4 bar R1 Pressure [bar] P T GM General purpose compensator with ISO 4401 size 06 mounting surface This solution allows different type of controls, like multiple pressure selection, venting, etc. whitch can be realized by installing proper control valves. The valves must be separately ordered.the pump must be equipped at least with a pressure setting valve. Flow [l/min] Hysteresis and pressure increasing; max 4 bar Pressure [bar] ISO 4401 size 06 mounting surface not supplied HL Load sensing The pump displacement is automatically adjusted to maintain a constant (load indipendent) pressure drop across an external throttle. hanging the throttle regulation, the pump flow is consequently adjusted. Load sensing control always incorporates an hydraulic compensator to limit the maximum pressure. ompensator setting range: 20 210 bar ompensator standard setting: 140 bar Differential pressure setting range: 13 27 bar Differential pressure standard setting: 21 bar Flow [l/min] Pressure [bar] Hysteresis and pressure increasing; max 4 bar 7 SHAFT DIMENSION PV- PV-23 TA16

8 DIMENSIONS OF PV-A = 3/4 SPP = 3/4 SPP = ain port, 3/8 SPP = Oil filling port, 3/8 SPP = Regulation screw for max pressure regulation; clockwise rotation for pressure increasing. view from view from view view from from A 14 LET LET A A OIL FILLG 21 Mass: 13 kg

9 DIMENSIONS OF PV-GM = 3/4 SPP = 3/4 SPP = ain port, 3/8 SPP = Oil filling port, 3/8 SPP view from Do not use LET LET A Mounting sourface ISO4401-03-02-0-0 T P A OIL FILLG 21 Mass: 13. kg TA16

10 DIMENSIONS OF PV-HL = 3/4 SPP = 3/4 SPP = ain port, 3/8 SPP = Oil filling port, 3/8 SPP X = Load sensing port, 1/4 SPP = Regulation screw for min. pressure regulation; clockwise rotation for pressure increasing (standard setting 21 bar) = Regulation screw for max pressure regulation; clockwise rotation for pressure increasing view from LET LET LOAD SENSG X 21 A OIL FILLG Mass: 13. kg

11 DIMENSIONS OF PV-23A = 1 SPP = 3/4 SPP = ain port, 3/8 SPP = Oil filling port, 3/8 SPP = Regulation screw for max pressure regulation; clockwise rotation for pressure increasing. view from 14 LET LET A OIL FILLG 21 Mass: 22 kg TA16

12 DIMENSIONS OF PV-23GM = 1 SPP = 3/4 SPP = ain port, 3/8 SPP = Oil filling port, 3/8 SPP view from Do not use LET LET Mounting sourface ISO4401-03-02-0-0 T P A OIL FILLG 21 Mass: 22. kg

13 DIMENSIONS OF PV-23HL = 1 SPP = 3/4 SPP = ain port, 3/8 SPP = Oil filling port, 3/8 SPP X = Load sensing port, 1/4 SPP = Regulation screw for min. pressure regulation; clockwise rotation for pressure increasing (standard setting 21 bar) = Regulation screw for max pressure regulation; clockwise rotation for pressure increasing view from LET LET LOAD SENSG X A OIL FILLG 21 Mass: 22, kg 03/17