leading edge, where the flow is fully separated. Both for the means and peaks, smooth flow leads to the highest values. A good correlation between cav

EFFECTS OF SIDEWALL OPENINGS ON THE WIND LOADS ON PIPE-FRAMED GREENHOUSES

OPTIMIZING THE LENGTH OF AIR SUPPLY DUCT IN CROSS CONNECTIONS OF GOTTHARD BASE TUNNEL. Rehan Yousaf 1, Oliver Scherer 1

SPECTRAL CHARACTERISTICS OF FLUCTUATING WIND LOADS ON A SEPARATE TWIN-BOX DECK WITH CENTRAL SLOT

MEASUREMENTS ON THE SURFACE WIND PRESSURE CHARACTERISTICS OF TWO SQUARE BUILDINGS UNDER DIFFERENT WIND ATTACK ANGLES AND BUILDING GAPS

Available online at ScienceDirect. Procedia Engineering 161 (2016 )

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

EXPERIMENTAL ANALYSIS OF THE CONFLUENT BOUNDARY LAYER BETWEEN A FLAP AND A MAIN ELEMENT WITH SAW-TOOTHED TRAILING EDGE

Wind Flow Validation Summary

Full scale measurements and simulations of the wind speed in the close proximity of the building skin

Wind tunnel tests of a non-typical stadium roof

DESIGN AND CHARACTERISTICS OF A LARGE BOUNDARY- LAYER WIND TUNNEL WITH TWO TEST SECTIONS

Pressure coefficient on flat roofs of rectangular buildings

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

Aerodynamic Measures for the Vortex-induced Vibration of π-shape Composite Girder in Cable-stayed Bridge

Aerodynamic Performance of Trains with Different Longitudinal Section Lines under Crosswind

Effect of airflow direction on human perception of draught

Numerical and Experimental Investigation of the Possibility of Forming the Wake Flow of Large Ships by Using the Vortex Generators

Improvement of the Volumetric and Isentropic Efficiency Due to Modifications of the Suction Chamber

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

A comparison of NACA 0012 and NACA 0021 self-noise at low Reynolds number

Determination of the wind pressure distribution on the facade of the triangularly shaped high-rise building structure

Fig 2.17: Topographic model: snow-free area (Snow boundary = red) Contour interval of 1 m.

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

The Seventh International Colloquium on Bluff Body Aerodynamics and Applications (BBAA7) Shanghai, China; September 2-6, 2012 Wind tunnel measurements

CFD Study of Solid Wind Tunnel Wall Effects on Wing Characteristics

THE AIRCRAFT SEAT AS INDOOR AIR QUALITY AND TEMPERATURE CONTROL SYSTEM

Geometry Modification For Minimizing The Aeroelastics Effect

Basis of Structural Design

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

Development of Biomimicry Wind Louver Surface Design

Measurement of Air Flow Rate in a Naturally Ventilated Double Skin Facade Larsen, Olena Kalyanova; Jensen, Rasmus Lund; Heiselberg, Per Kvols

Single-sided Natural Ventilation Driven by a Combination of Wind Pressure and Temperature Difference Larsen, Tine Steen; Heiselberg, Per Kvols

Validation of a microscale wind model using ultrasonic-anemometer data M. Wichmarin-Fiebig Northrhine- Westphalia State Environment Agency,

CFD Analysis ofwind Turbine Airfoil at Various Angles of Attack

E. Agu, M. Kasperski Ruhr-University Bochum Department of Civil and Environmental Engineering Sciences

SEMI-SPAN TESTING IN WIND TUNNELS

EFFECT OF CORNER CUTOFFS ON FLOW CHARACTERISTICS AROUND A SQUARE CYLINDER

Evaluation of n-situ easurement ethods for ir ermeability of indows

WP2 Fire test for toxicity of fire effluents

AN IMPROVED CROSS VENTILATION MODEL IN WINDY REGIONS

STABILITY OF MULTIHULLS Author: Jean Sans

LONGITUDINAL AIR VELOCITY CONTROL IN A ROAD TUNNEL DURING A FIRE EVENT

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

Wind pressure coefficient determination for greenhouses built in a reclaimed land using CFD technique

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations

EXPERIMENTAL STUDY OF WIND PRESSURES ON IRREGULAR- PLAN SHAPE BUILDINGS

Purdue e-pubs. Purdue University. Stephan Lehr Technische Universitaet Dresden. Follow this and additional works at:

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

Design process to evaluate potential of wind noise at façade elements

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Measurement and simulation of the flow field around a triangular lattice meteorological mast

PRESSURE FLUCTUATIONS ACTING ON A TAPERED TALL BUILDING

Wind tunnel effects on wingtip vortices

The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion

Ski preparation as a three-dimensional problem

Wind Directional Effect on a Single Storey House Using Educational Wind Tunnel

Development of virtual 3D human manikin with integrated breathing functionality

A Study on the Distribution of the Peak Wind Pressure Coefficient for the Wind Resistant Design of Rooftop Hoardings in High-rise Buildings

Spectral analysis of wind turbulence measured by a Doppler Lidar for velocity fine structure and coherence studies

Vibration Analysis and Test of Backup Roll in Temper Mill

PRESSURE DISTRIBUTION OF SMALL WIND TURBINE BLADE WITH WINGLETS ON ROTATING CONDITION USING WIND TUNNEL

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

EXPERIMENTAL AND ANALYTICAL INVESTIGATION OF THE EFFECT OF BODY KIT USED WITH SALOON CARS IN BRUNEI DARUSSALAM

PROPAGATION OF LONG-PERIOD WAVES INTO AN ESTUARY THROUGH A NARROW INLET

23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN APRIL 2007

ON INVESTIGATING INSTANTANEOUS WIND- DRIVEN INFILTRATION RATES USING CO 2 DECAY METHOD

OPTIMIZATION OF INERT GAS FLOW INSIDE LASER POWDER BED FUSION CHAMBER WITH COMPUTATIONAL FLUID DYNAMICS. Abstract. Introduction

Wind Flow Model of Area Surrounding the Case Western Reserve University Wind Turbine

Predicting the Suction Gas Superheating in Reciprocating Compressors

A Research on the Airflow Efficiency Analysis according to the Variation of the Geometry Tolerance of the Sirocco Fan Cut-off for Air Purifier

Effects of wind incidence angle on wind pressure distribution on square plan tall buildings

Wind Tunnel Study on the Structural Stability of a Container Crane According to the Boom Shape

Copyright by Turbomachinery Laboratory, Texas A&M University

AIRFLOW AROUND CONIC TENSILE MEMBRANE STRUCTURES

THE BRIDGE COLLAPSED IN NOVEMBER 1940 AFTER 4 MONTHS OF ITS OPENING TO TRAFFIC!

Real Life Turbulence and Model Simplifications. Jørgen Højstrup Wind Solutions/Højstrup Wind Energy VindKraftNet 28 May 2015

Akasison Flow phenomena of a siphonic roof outlet

Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle

CRYSTALLIZATION FOULING IN PACKED COLUMNS

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Investigation on 3-D Wing of commercial Aeroplane with Aerofoil NACA 2415 Using CFD Fluent

PARAMETRIZATION OF WAVE TRANSFORMATION ABOVE SUBMERGED BAR BASED ON PHYSICAL AND NUMERICAL TESTS

Sound scattering by hydrodynamic wakes of sea animals

Development of a load model for men-induced loads on stairs

Installation Effects on Ultrasonic Flow Meters for Liquids. Jan Drenthen - Krohne

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

CALMO

Workshop 1: Bubbly Flow in a Rectangular Bubble Column. Multiphase Flow Modeling In ANSYS CFX Release ANSYS, Inc. WS1-1 Release 14.

Figure 1 Schematic of opposing air bearing concept

Greenup Lock Filling and Emptying System Study

Study of Passing Ship Effects along a Bank by Delft3D-FLOW and XBeach1

Numerical Analysis of Wind loads on Tapered Shape Tall Buildings

RESOURCE DECREASE BY LARGE SCALE WIND FARMING

Bio-Effluents Tracing in Ventilated Aircraft Cabins

Universities of Leeds, Sheffield and York

The Usage of Propeller Tunnels For Higher Efficiency and Lower Vibration. M. Burak Şamşul

Transcription:

Influence of the external dynamic wind pressure on the ventilation of double facades Claudia Ziller & Bernd Döring Institute of steel construction, Aachen, Germany ABSTRACT: The ventilation rate in the cavity of a double facade is dependent on the characteristic of the wind directly in front of the facade. This effect was investigated by wind tunnel tests. The results show, that the turbulence and the integral length scale are not sufficient, to describe the amount of the air change. The frequency resp. the wavelength of the wind speed in the opening has a strong influence on the ventilation rate. Only a high quota in the wind spectrum that matches the dimensions of the openings leads to high ventilation rates. 1 INTRODUCTION In northern Europe, specially in Germany, Austria, the Benelux and Switzerland the importance of double facades is still increasing significantly. In different estimations of several engineering offices, architects and facade specialists is predicated that a double facade area of 2. to 4. m² is erected yearly, that corresponds to a volume of 2 to 4 Million. Air conditioning systems which are not optimized can cause the so called sick building syndrome (Kröling, 1995) which means that the user of full air conditioned rooms feel uncomfortable which can increase the time where people call in sick. Twin facade systems are representing a possible solution to limit the period of time where mechanical ventilation of the buildings is necessary and in some cases it may even be possible to plan a building without an air conditioning system. To obtain comfortable low room temperatures in summer it is possible to combine a double facade with a ceiling with integrated cooling systems. Twin facade systems are often used for buildings in exposed areas when window ventilation is not possible due to high wind velocities which causes uncomfortable draft in rooms and for buildings that are exposed to noise pollution when window ventilation is not possible due to for example traffic noise. 2 STATE OF THE ART In the design of buildings using the twin facade system and the calculation of air change rates traditionally the thermal forces (temperature differences between the room temperature and the enviroment) and the different wind loads on the different sides (windward and lee side) of the building are investigated. The influence of the air change rate in rooms and the temperature difference between the room and the environment is shown in (Ziller, 1999) and (Ziller 2). Furthermore in this study the influence of the external wind loads, the buildings architecture (e.g. the door gap between the windward rooms and the rooms on the lee side) on the rooms ventilation is investigated. Figure 1 and 2 are showing the ventilation coefficients of a room with a double facade. Figure 1 shows the results of a full scale measurement in comparison with the results of a model test where the ventilation coefficient is a function of the temperature difference T R = T Room -T Enviroment, with 2 different window openings. Figure 2 shows the influence of the wind pressure on the room ventilation where the height of the door gap is varied.

Ventilation Rate n [1/h] 8 7 6 5 4 3 2 1 Approximation 3 Windows Opened 1 Window Opened Model Test 3 Windows Opened Full Scale Test Model Test 1 Window Opened Full Scale Test 2 4 6 8 1 12 14 16 18 Temperature Difference T R [K] Figure 1: Ventilation coefficient in a room (full scale and model) with a double facade as a function of the temperature difference 7 _ p p(t,z) p ou(t) V( p ou ) + y z x Figure 3: Influence of small-sized pressure differences on the flow characteristic of a double facade 3 Volume Flow V [m /h] 6 5 4 3 2 1 door gap 1mm Bernoulli Approx. Door gap 7mm Bernoulli Approx. door gap 5mm Bernoulli Approx. 1 2 3 4 5 Wind Pressure p [Pa] Figure 2: Model test results of the ventilation coefficient in a room as a function of the wind pressure and the hight of the door gap 3 BASIC APPROACH Figure 2 shows the influence of the wind pressure differences on the room air change rate which are caused by the on-flow of the entire building (positive pressure at the windward side, negative pressure at the lee side). Pressure differences which are small-sized and occur on one side of the building are not considered yet. Wind has in full size a turbulent character, which means that a permanent varying pressure distribution p(t,z) occurs on each side of the buildings surface due to the natural turbulence of the wind (Figure 3) which can be described as p(t,z) = p + p(t,z). This effect induces pressure differences p ou (t) between the inlet and the outlet of the secondary facade, which in turn results in a air flow in the gap between the inner and the outer glass front. The aim of the investigations which are presented in this paper is to quantify the air flow in the gap between the two facades and to estimate this influence on the quality of the ventilation of the room. 4 THEORETICAL CONSIDERATIONS One possibility to characterize wind gusts is to consider the integral lengthscale in vertical, transversal and longitudinal direction. For the investigation of the pressure differences between the openings in the 2ndary facade layer the vertical dimensions (L uz ) are of importance. Dependent on the height of the facade element and the surface roughness L uz reaches values between L uz = 15 and 1 m. It has to be noted that the integral lengthscale is a mean value, there are portions in the spectrum of a gust which correspond to the dimensions of the double facade as shown in the principal in Figure 3. ns(n) u u² τ 2 1.8 1.6 1.4 1.2 1.8.6.4.2 Dimensions of facade 2 1 1 1 1 1 wavelength [m] Figure 4: Spectral distribution of the wind velocity, Assumption of (Davenport, 1961 (1)) and (Cermak, 1976 (2)) The spectral distribution of the wind velocity (as a function of the wave length as shown in Figure 4) demonstrates that the maximum portion of the wave lengths are greater than 5m. The part which is important for the air flow in the gap of double facades (wave length of 4 to 6 m) is marked in the figure above (Figure 4). These are values where the distance between the inlet and the outlet corresponds to the half of the wave length. 1

5 MODEL TESTS 5.1 Similarity Parameters To perform model tests it is necessary to derive so called similarity parameters which describe the physical process and allow the transformation of the model test results to the full scale. In the most model tests it is not possible to maintain all of the governing similarity parameters. Without going into detail the here used similarity parameters are as follows: Geometric model scale: 1:1 Velocity Scale: 1:1 5.2 Wind Tunnel Model and Experimental Setup For the model tests the Wind Tunnel in the Institute of Steel Construction at the RWTH Aachen, Germany is used. This is an open-circuit type wind tunnel with dimensions of 2.5 m width and 1.7 m height. The maximum wind speed amounts ca. 3 m/s. In order to meet the correct relation of the integral length scale of the wind-tunnel-wind and the full scale wind characteristic a model scale of M=1:1 is chosen. The depth of the gap between the two fa- 3 mm 16 mm 12 mm Chamber 25 mm 35 mm 2 mm Perforated Panel 3 mm 53 mm 25 mm Plate to vary Inlet and Outlet Hight Not Scaled! Injection of Air / Tracergas Mixture 25 mm Figure 5: Principle Drawing of the Wind Tunnel Model Figure 6: Wind Tunnel Model Test Model in the Wind Tunnel

Volume Flow (Pressure). p V Gas Analyzer [%] CO 2 Detection Wind Tunnel Venturi II Venturi I CO 2 Twin Facade Box Volume Flow (Pressure). p V Figure 7: Principle Drawing of the Experimental Setup cade layers is scaled up by a factor of 1 in order to reduce the influence of the surface roughness. A second reason to increase the depth of the gap is the experimental procedure, where tracer gas is used to measure the ventilation. The measurement gas mixture gas is injected into a chamber which is connected by a perforated. panel to the space between the primary and secondary facade. The primary facade has inlet and outlet openings which are positioned at the bottom and at the top of the twin facade box. To determine the influence of the size of the openings it is possible to vary the height of the model inlet and outlet in three steps. Figure 5 shows a principle drawing of the wind tunnel model with its basic dimensions. Figure 6 shows pictures of the model itself (left side) and of the model in the wind tunnel (on the right side). 5.3 Measurement Procedure The so called Method of constant injection is used for the wind tunnel tests. Detailed information about this method are given in (Raatschen, 1995). That means that a gas mixture consisting of air and a tracer gas (CO 2 ) with a constant concentration and a constant volume flow is injected into the measurement volume, the twin facade box. The concentration and the volume flow of the tracer gas which can be varied by a throttle are recorded continuously during the tests. Probes of the gas mixture in the twin facade box are sampled where the concentration of the remained tracer gas is detected. The relation of the concentration of the injected tracer gas and the concentration of the tracer gas measured in the modelled twin facade box gives information about the wind induced volume flow in the facade box. By taking a probe of the gas mixture in the facade box it is important to limit the probe volume flow to a certain level. Otherwise the flow characteristic inside of the box can be disturbed by the probe sampling and the measurement results are falsified. Compared to the volume flow of the injection and the volume flow of the air the volume flow of the probe has to be significantly smaller. Figure 6 shows the principle of the experimental setup. The measurements in the wind tunnel were made without boundary layer, wind characteristic were changed by using a grid to induce a higher turbulence and a smaller integral length scale (table 1). The turbulence was measured using a LDA (Laser-Doppler-Anemometer), the integral lengthscale was determined by the Taylor-hypothesis. Table 1. Characteristics of the wind tunnel Turbulence I integral lengthscale L uz no boundary layer 6 % ca. 1 cm no boundary layer, 9 % ca. 7 cm with grid 6 MEASUREMENT RESULTS Turbulence Grid The following diagrams are showing some of the results of the wind tunnel tests. In Figure 8 the influence of the turbulence intensity and the mean wind velocity on the ventilation rate of the twin facade box is demo nstrated.

Airchange [1/h] 7 6 5 4 3 2 1 2 4 6 8 u [m/s] mean no boundary layer no boundary layer, with grid Figure 8: Ventilation rate dependent on the incoming wind The ventilation rate of the cavity in "airchanges per hour" was ascertained for the real scale by using the scaling factors for geometry and time. The height of the inlet and outlet in the primary facade is fixed during the measurements with approx. 18 mm. As expected the ventilation rate increases with an increasing mean wind velocity. Quite unexpected is that the ventilation rate for higher turbulence intensities ( no boundary layer with grid ) is reduced compared to the ventilation coefficient in the twin facade box with an on-flow characteristic with a low turbulence intensity. Due to this effect additional measurements to determine the effect of the turbulence intensity are necessary. Hot wire probes are placed directly into the inlet and outlet openings (Figure 9) to detect the flow characteristic depending on the original turbulence intensity. In a second series of measurements the hot wire probes are placed in different distances to the model to get the mean velocity (scalar) and the turbulence. u mean [m/s] 2. 1.8 1.6 1.4 1.2 1..8.6.4.2. 2 4 6 8 1 distance from facade [cm] outlet, no grid outlet, with grid inlet, no grid inlet, with grid Figure 1: Mean wind speed in the facade openings (distance cm) and in front of the facade turbulence 9% 8% 7% 6% 5% 4% 3% 2% 1% % 2 4 6 8 1 distance from facade [cm] outlet, no grid inlet, no grid outlet hot wire probes wind outlet, with grid inlet, with grid Figure 11: Turbulence in the facade openings (distance cm) and in front of the facade height ca. 18 mm inlet cm 2 cm 4 cm 6 cm distance from facade Figure 9: Positions of hot wire probes Regarding the high degrees of turbulence in the openings and close to the facade it has to be pointed out, that in this cases the direction of the wind speed changes, what can not be detected by the hot wire probes. This fact affects the results of a spectral analysis, nevertheless the normalised spectra of the wind speed in the ventilation openings give hints for an explanation of the unexpected ventilation rates (Figure 12). In the tests without grid, the frequencies in the range of to ca. 4 Hz have a significant higher value as in the tests with the grid. Regarding the measured wind speeds and the dimensions of the modell, these frequencies are relevant for the airchange in the cavity. Higher frequencies cause mainly an oscillation of the enclosed air volume with only small effects concerning the air change.

For frequencies above 2 Hz, the spectral analysis gives higher values for the investigations with the turbulence grid in the wind tunnel. S (n) u.7.6.5.4.3.2.1 relevant for ventilation 1 2 3 4 n [Hz] no grid with grid Figure 12: Spectrum of wind speed in the lower ventilation opening 7 NUMERICAL CALCULATIONS Beneath the measurements of the ventilation rate by using the "method of constant injection" a second path to get information about the airchange was taken: A "semi-numerical" calculation, based on dynamic pressure measurements on a surface of a cube. For these calculations some assumptions concerning the characteristic of the air flow has to be done: the relevant flow resistance is given by the openings, the resistance of the cavity is neglected the air volume V in the cavity moves homogenous, internal eddies are neglected With these assumptions the movement of the air, forced by the pressure differences between to points of the cube, that represent the openings, can be calculated. Small oscillations of the air volume in the cavity which are much smaller as the distance between the openings do not cause a significant air change. A complete air change is given, if the air volume V moves more then the distance between the openings. For this calculation only these large movements were considered. Different geometric scales can be simulated by using the points with different distances on the cube. Differing from the air change measurements, the pressure was recorded with a boundary layer. This leads to different characteristics of the wind (table 2; Zillinger, 1995): Table 2. Characteristics of the wind tunnel with boundary layer Turbulence I integral lengthscale L uz with boundary layer 23 % ca. 3 cm The results are given in Figure 12, additionally the results of the measurements are marked. For this semi-numerical method, an increasing airchange rate for smaller integral lengthscales can be detected up to L uz = 15 m. For the lowest integral lengthscale of 9 m, the ventilation rate is decreasing. The order of magnitude is suitable for the airchange measurements. A complete correlation could not be expected, as the characteristic of the incoming wind is different. Airchange [1/h] 7 6 5 4 3 2 1 measurements of airchange rate semi-numerical 1 2 3 4 5 6 7 8 L uz [m] Figure 12: Results of numerical calculations based on pressure measurements (semi-numerical) for mean wind speed of 4 m/s 8 SUMMARY AND CONCLUSIONS Model tests for the air change in the cavity of a double facade are performed to investigate the relation of the ventilation rate and the characteristics of wind. The wind tunnel was used without boundary layer, the wind characteristic was changed by using an additional grid. The results of the air change measurements showed a significant reliance on the wind characteristic. The first assumption, that higher turbulence and lower integral lengthscale causes higher ventilation rate, could not be proved generally. The parameters "turbulence" and "integral lengthscale" are not sufficient for estimating the ventilation rate. Instead of this the frequencies of the wind speed directly in front of the facade an in the ventilation openings determine the ventilation rate. The semi-numerical method of calculating the ventilation rate using measurements of dynamic pressure leads to results that correspond to the as-

sumption for larger integral lengthscales, for very small integral lengthscale the trend of the measurements could be confirmed. Going out from these results, further investigations have to be made: As the hot wire probes can not detect the direction of the wind speed, additionally the pressure has to measured parallel to the wind speed in the openings. The geometrical relation of the model and the wind and the characteristic of the wind has to be varied, to work out mathematical relations between the parameters. To verify the evidence of the model tests for real objects, the effects of Reynolds number have to be checked, measures in accomplished buildings are aspired. REFERENCES Kröling, P. (1995): "Sick Building Syndrom" In Baumeister, vol. 7/1995, pp. 5-54 Ziller, C. (1999). Modellversuche und Berechnungen zur Optimierung der natürlichen Lüftung durch Doppelfassaden PhD Thesis, RWTH Aachen, Germany, 1999. Ziller C. (2) Natural Ventilation of Rooms with Twin-Facade Systems In: Proceedings of the IBPC 2, Eindhoven, Netherlands, September 18-21 2. Davenport, A.G. (1961). The spectrum of horizontal gustiness near ground in high winds, Quart. J. R. Met. Soc. 87, S. 194-211, 1961 Cermak, I.E. (1976). Aerodynamics of Buildings, Annual Review of Fluid mech. 8., S. 75 16 (1976) Raatschen, W. (1995). Tracergasmessungen in der Gebäudetechnik, Luftaustausch Messung und Simulation In: gi vol. 116, no. 2, pp. 78-87 and no. 3, pp. 129-138. Zillinger, W. (1999). Niedrige Stahlhallen im Grenzzustand der Tragfähigkeit unter dynamischer Windbeanspruchung PhD Thesis, RWTH Aachen, Germany, 1998