Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

Similar documents
Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

M5400 Operators Manual

Table Top and Convertible Anesthesia Machine Models: M3000 and M3100 (SHOWN WITH OPTIONAL EQUIPMENT)

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Yoke Block Instruction Manual

Yoke Block Instruction Manual

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

PORTER INSTRUMENT COMPANY, INC.

NITRONOX SCAVENGER SYSTEM USER S MANUAL / INSTRUCTIONS

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

RG2200 BC Integrated Octopus

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

MOBILE E TANK STAND INSTALLATION AND INSTRUCTIONS

Draeger Fabius GS Pre-Use Check

VAPOMATIC ANESTHETIC VAPORIZER

Breathing Systems. Professor Khalid Bashir

MEDICAL BREATHING CIRCUIT SCAVENGER SYSTEM USER S MANUAL / INSTRUCTIONS

SurgiVet Universal CDS 9000 Small Animal Anesthesia Machine Operation Manual

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

Anes Machine Use and Pre-use Check - CA1 focus

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Flow meter. bellow vaporizer. APL valve. Scavenging system

STANDARD FLOWMETER USER S MANUAL

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

MODEL CALIBRATION GAS DELIVERY SYSTEM

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATORS OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY GLOSSARY OF SYMBOLS. : ON (power switched on)

G7S Hand Pump Owner s Manual

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

RK LEL Sample Draw Aspirator Adapter Operator s Manual

PERSONAL AIR BREATHING UNIT

RK-IR Sample Draw Aspirator Adapter Operator s Manual

4 and 8 Station PDS Control Installation & Operators Manual

453 Series Steam Heated Vaporizing Regulator

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA Tel: Ref Rev.

KJ4000 Operating Instructions & Parts Manual NSN

CSA Sample Draw Aspirator Adapter Operator s Manual

Model 687 Mouse Ventilator User s Manual. Model 687 Mouse Ventilator

Anesthesia. Midmark Animal Health Products

RAM 4021 Operation Manual

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

Gemini Owner s Manual

Anesthesiology Research and Scholarship. Follow this and additional works at:

Recommendations on Checking Anaesthesia Delivery Systems

Model ASSEMBLY and OPERATING INSTRUCTIONS

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

UNIVERSAL MASK TEST SYSTEM

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

- GAS REGULATOR - COMPACT STYLE

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

with O 2 Controller Instruction Manual

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process

SC505 Sof Care Inflator. Operating Instructions and Service Manual

BioPak 240 Revolution

Operation and Maintenance of the EPV200 Portable Ventilator

Anesthesia Machine Intro

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

User Guide and Operating Manual

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

MicroVent 1 Dual Mode Veterinary Ventilator IPPV / HFOV

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

Pulmonex II Training Presentation

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Halsey Taylor Owners Manual STOP!

AIR INLINE METAL SHEAR

Operation Manual. O2 Quickstick. Oxygen Analyzer

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

BioPak 240 Revolution

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

Hallowell EMC Vacuum / Scavenging Interface

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

6 & 8 Bubble Panel Installation Manual

700 SERIES BMS II BUBBLER MONITORING SYSTEM

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

Hallowell EMC Anesthesia WorkStation Operating Manual

Checking a Breathing System

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Breathing Circuits. Product training

AB800 ABSORBER USER MANUAL

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Transcription:

Operators Manual Supera Wall Mount Anesthesia Machines Models: M2300 M2500 (All shown with optional equipment) M2300 M2500

Examination and Preparation for Use Thank you for ordering an Supera Anesthesia Innovations anesthesia machine! We are delighted to have you as a Supera Anesthesia Innovations customer and want you to be completely satisfied with your purchase. Please inspect the contents of your order to see if everything is as you expected. Should anything not be exactly right or if anything was damaged in shipping, please contact your sales representative right away for help. Our goal is to make your new anesthesia machine as easy to use and care for as possible. This device is meant to be operated under the normal surveillance and control of a veterinarian trained in its use. However, you need to know more about this device than just how to operate it. Please read this manual in its entirety before using the anesthesia machine. If you have any comments or questions, we welcome the opportunity to address them. Please contact us directly at 877 620 1500. Thank you! Brian Lawson President, Supera Anesthesia Innovations Proudly 100% American Made In Our State of The Art Manufacturing Facility in Portland Oregon!

TABLE OF CONTENTS Machine Assembly Page Mounting Breathing circuits Technical Information Ordering information Warranty /Return Machine & Service Notes

Chapter 1: Mounting Mounting Bracket IMPORTAINT The M2300 should be mounting into a solid wall stud or back board. The mounting holes are on 16 centers (standard wall stud distance) Use lag screws (5/16 or 3/8 ) to mount to the wall.

Circuits CIR518 - Non-Rebreathing Modified Jackson-Rees The Non rebreathing system connects to the common gas outlet of the anesthesia machine. 1. Disconnect the common gas outlet from the rebreathing head. (quick disconnect fittings) 2. Plug the 15mm male connector from the non rebreathing system into the common gas outlet of the anesthesia machine. 3. Connect the blue exhaust port on the bag of the non rebreathing system to the 19mm blue evacuation tubing connected to the waste gas interface device or to any other waste gas evacuation device (outside air, F air canister, etc.)

Circuits CIR529 & CIR529P Rebreathing Unilimb circuits Unilimb design removes clutter and disorder from the anesthesia field. Patients exhaled breath acts as a thermal wrap to maintain the temperature and humidity of inspired gases. The swivel connector at the patient end eliminates kinking of the tubing. This circuit attaches to the Inhalation and Exhalation ports on the rebreathing head (Co2 Absorber) P/N CIR529 Adult (blue inner tube) Recommended for Patients weighing above 20kg P/N CIR529P Pediatric (Pink inner tube) Recommended for Patients weighing under 20kg

MAINTENANCE Anesthesia Machine The Supera Anesthesia Innovations anesthesia machine should be serviced by a certified technician. Only certified service companies will have the factory specifications and access to original replacement parts. Annually Service will include: Pre service low and high pressure test. Inspection and replacement of hoses, gaskets and seals. Measure pressure relief valve resistance Inspect unidirectional valves. Inspection of evacuation system. Inspection of oxygen system. Verification of vaporizer concentration output. Final low and high pressure test. Daily Inspection - Leak Test Before each use check for pressure leaks in the machine. Also make certain the waste gas evacuation system is working properly. 1. Close the pop off valve and cover the Y piece of the rebreathing hose with your palm or finger. 2. Push the oxygen flush button or turn the flowmeter on until the bag is distended and the pressure gauge reads 20 CM H20. 3. Turn the oxygen off and watch the manometer. If the manometer reading drops rapidly, bag deflates rapidly, or if you hear a hissing sound, you have a leak. 4. Check hoses, bag, vaporizer inlet and outlet, any mechanical fittings, and the seal at the top of the absorber canister for leaks. Spray window cleaner around fittings to help find leaks. 5. When the pressure remains fairly constant, with the oxygen turned off, your machine can be considered leak free on the low pressure side. 6. With your thumb still over the y piece, open the pop off valve all the way and squeeze the bag to ensure the gases have an unobstructed way out of the evacuation system.

Warranty / Return Policy Supera Anesthesia Innovations warrants that each product or part shall be free from defects in workmanship and materials, under normal use and with appropriate maintenance, for 10 (ten) years from the date of purchase. For plastic, rubber and disposable parts or items, Supera Anesthesia Innovations warrants only that each such part and item shall be free from defects in workmanship and materials at the time of delivery. This warranty shall be void for any product that has been altered, defaced or removed from the original Supera Anesthesia Innovations product. Supera Anesthesia Innovations shall not be liable for any damage, injury or loss arising out of the use of the product, whether as a result of a defect in the product or otherwise, if, prior to such damage, injury or loss, the product was (1) damaged,misused, or misapplied; (2) repaired, altered or modified by persons other than Supera Anesthesia Innovations; (3) not installed in strict compliance with the applicable codes and ordinances; (4) not installed by Supera Anesthesia Innovations or an authorized Supera Anesthesia Innovations dealer. UNDER NO CIRCUMSTANCES SHALL Supera Anesthesia Innovations BE LIA- BLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES AS THOSE TERMS ARE DEFINED IN THE UNIFORM COMMERCIAL CODE. All items returned for service or repair are the responsibility of the customer. Proper packing methods should be used in returning items to Supera Anesthesia Innovations.

DOCUMENTATION Date purchased: Purchased from: Machine serial number: Vaporizer serial number: Machine service information Service Date: Service information: Service Date: Service information: Service Date: Service information: