ADA STANDARD OVERVIEW AND SPEAKMAN APPLICABLE PRODUCTS

Similar documents
California Building Code Effective January 2014 HOUSING ACCESSIBILITY BATHING FACILITIES Title 24, Part A

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

CURRENT ADA AND ICC COMPLIANCE DATA AN INTRODUCTION TO BOBRICK S ADA- COMPLIANT PRODUCTS, AS WELL AS BASIC MOUNTING HEIGHTS AND REACH RANGES

ACCESSIBILITY CHECKLIST

Chapter 5. General Site and Building Elements

Accessible Swimming Pools and Spas

sensible sophistication

DESIGNER FAUCETS & ACCESSORIES

CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS

ADA Access Standards for Swimming Pools, Wading Pools, and Spas

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 8 RECREATION FACILITIES

ADA COMPLIANCE CHECKLIST (RESTAURANT) Meet Fail N/A. Parking Lot

REVIEW OF ACCESSIBILITY FEATURES

Circular Turning Space. 8 Significant Changes to the ICC A

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

DIVISION 10 SPECIALTIES

Location: Cariboo, One Hundred Mile House, Cariboo Chilcotin Coast - Provincial : Park (Heritage Discovery Circle Route)

Aquatic Facility Evaluation City of Merriam, Kansas. Kyle A. McCawley, P.E. Larkin Aquatics 4/9/2014

Standards vs. Guidelines. Public Right-of Way Accessibility Guidelines (PROWAG)

California Conference of Directors of Environmental Health Recreational Health Technical Advisory Committee September 17, 2003

Welcome to the AccessibilityOnline Webinar Series

table of contents bath accessories Cable Drains...19 Cover Plates Drains Drain Conversion Kits...20

Unit # ± 5,514 SF Width ± 85' Depth ± 68' Plans produced by: ID Plans 10/12/2016 (813)

- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted.

ada compliance swimming pool Compliance guide

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Decorative Accessories Guide

Palmer township, Pennsylvania. Pool & Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

POOL AND SPA REPLASTERING AND/OR REMODELING REQUIREMENTS

Stand-N-Fish FULL DETAIL INSTALLATION INSTRUCTIONS

Palmer township, Pennsylvania. Pool Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

Decorative Accessories Guide

SNT Installation of a SNT Walk In Bath Tub follows the basic steps below. SNT: $2,248.00

Engineering Excellence. Installation Guide

dpd Seattle Permits Tip Getting a Grip on Handrails PURPOSE OF HANDRAILS

THE KEENEY MANUFACTURING COMPANY

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles)

Storage Systems and Accessories

SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET

Building Code Guidelines For Home Pools

Field guide for Accessible Public Rights-of-Way Edition

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Swimming Pool Fence Guide Kodiak Iron

B LCTV_v3 4/27/04 10:54 AM Page 1 Series e700

Building Code Guidelines For Home Pools

ADA Library Accessibility Checklist

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Accessible Swimming Pools and Spas. Welcome to the Accessibility Online Webinar Series. Webinar Features

Effective Date: May Rev. 6/18/2018- Void After: May Product: Plumbing Fixture Fittings File No. 3489

Swimming Pool Plans and Specification Report

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEMS CHART A-1 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"

ORNAMENTAL CANTILEVER GATE INSTRUCTIONS

Building Code Guidelines for Residential Pools

POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS

VERTICAL BLADDER TANK

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure

Horizontal Bladder Tanks

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

SECTION WASHROOM ACCESSORIES

GENO -Flushing Compressor Product Data Sheet F 02

New and Upcoming Products Update

STAD-C. Balancing valves DN 15-50

INSTALLATION INSTRUCTIONS

Example Applications of the Proposed Medical Diagnostic Equipment Accessibility Standards

U.S. Patent No. 7,922,246. Patents Pending

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

TAPS + ACCessories. an everyday luxury

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks

CRANE WITH WINCH USE AND MAINTENANCE MANUAL. Code Rev. Release MD /03

Check with local zoning official for property line distance requirements.

E. Test, and if needed, adjust tips of antenna. 1. Mark will test antennas with meter at ground end of feedline bundle. Will take 10 minutes.

Model MTB-ASME Vertical Bladder Tanks

accessible swimming pools & spas

SECTION BUTTERFLY VALVES

appendix a recommended rules For sizing the water supply system PRE-PRINT Chart a 1.2 FriCtion losses For Disk-type water Meters

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM CHART A 1.2 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"

KC Series Gas Components and Supply Design Guide

Transfer Chain (SA-1002) & Adjustable I-Beam Clamp (SA-1039 or SA-1040) Operating Instructions

Vertical Bladder Tanks

Hatch cover securing and tightness

Department of Public Works Office of Disability Affairs February 23, 2017 Presented by Mark Zwoyer, PE

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

User Instruction Manual Fixed Beam Anchor

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Type overview. R B2 en-gb subject to changes 1

Installation, Operation and Maintenance Manual for Back Pressure Regulator

1 & 3 Meter Tower CAT 1M 203R RIGHT MOUNT CAT 3M 203R CAT 1M 203L LEFT MOUNT CAT 3M 203L CAT 1M 203D DUAL MOUNT CAT 3M 203D

Global Lift ADA Compliance

How-To-Buy Guide for Bathtubs & Whirlpools

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

SIZING OF WATER PIPING SYSTEM

Department of Public Services Building Engineering Planning Water & Sewer POOL, HOT TUB & FENCE REQUIREMENT CHECKLIST

-SWEPT AWAY- Description & Overview. VEX Classroom Competition Swept Away

RESIDENTIAL SWIMMING POOL

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

HIP PRECAUTIONS INFORMATION

Transcription:

ADA STANDARD OVERVIEW AND SPEAKMAN APPLICABLE PRODUCTS ADA PRODUCT TRAINING PG. 1 Specs are for reference only. Please refer ADA.gov for the latest requirements.

ADA What is the Americans with Disabilities Act (ADA)? THE ADA STANDARD WAS DEVELOPED TO ENSURE that the built environment was accessible to people with disabilities. The ADA Standards Water Closet Diagram establish the necessary design requirements for the construction and alteration of facilities subject to the law. These enforceable standards apply to places of public accommodation, commercial facilities, and state and local government facilities. Speakman Company takes care to follow these guidelines and designs our products to comply with them. The ADA Standards apply nationwide, in addition to any applicable state or local codes, where facilities are newly built or altered...the Access Board s 2004 ADA Accessibility Guidelines, upon which the current ADA Standards are based, have been harmonized to a significant extent with industry standards and model building codes... Considering this, our products comply with both the ADAAG TOWEL RACK Robe Hook 42 min. and ICC/ANSI A117.1 requirements. The United States Access Board is responsible for the development and maintenance of the guidelines. These guidelines, are known as ADA Accessibility Guidelines or ADAAG for short. Chapter 6 of the Standard is for 40-48 TOILET 33-36 40-48 Plumbing Elements & Facilities. Source: https://www.access-board.gov/guidelines-and-standards/buildings-and- BATHROOM sites/about-the-ada-standards FIG. 604.5.1 ADA PRODUCT TRAINING PG. 2 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

ADA WATER CLOSET REQUIREMENTS 603 Toilet & Bathing Rooms 603.4 COAT HOOKS AND SHELVES: Coat hooks shall be located within one of the reach ranges specified in Section 308. Shelves shall be 40 minimum and 48 maximum above the floor. General Note: Throughout Chapter 6 is the exception that Grab bars are not required to be installed in private washrooms for a single occupant, washrooms that can only 604.5.2 REAR WALL S: 36 In. minimum length installed horizontally. There are exceptions to this length where wall space does not permit for a 36 In. length bar 604.8 COAT HOOKS & SHELVES: Coat Hooks: Mounted maximum 48 In. above the floor Shelves: Mounted minimum 40 In. & maximum 48 In. above the floor be accesses via a private office or that are not for common or public use. 604 Water Closets & Toilet Compartments SPEAKMAN ACCESSORY SOLUTIONS: Robe Hooks Towel Racks Note: this outlines the specification for an adult washroom, section 604.11 is specific to Water Closets & Toilet Compartments for Children s Use. SA-1008 SA-1008-BN SA-2003 SA-2003-BN 604.5 S: Grab Bars for water closets shall comply with Section 609 and shall be provided in accordance with Sections 604.5.1 & 604.5.2. Grab bars shall be provided on the rear wall & on the side wall closest to the water closet. SA-1306 SA-1406 SA-1607-PC SA-2203 SA-2203-BN SA-2303 SA-2403 SA-2403-BN 604.5.1 FIXED SIDE WALL S: 42 In. minimum length installed horizontally. 18 In. minimum length bar installed vertically. 604.5.1 FIXED SIDE WALL S: 42 In. minimum length installed horizontally. 18 In. minimum length bar installed vertically. SA-2006 SA-2006-BN SA-2306 SA-2406 SA-2406-BN SA-2408 SA-2408-BN ADA Grab Bars SA-1009-24 SA-1009-24-BN SA-1009-36 SA-1009-36-BN SA-1009-48 SA-1009-48-BN SA-1309-24 SA-1309-24-BN SA-1309-36 SA-1309-36-BN SA-1309-48 SA-1309-48-BN ADA PRODUCT TRAINING PG. 3 Specs are for reference only. Please refer ADA.gov for the latest requirements.

ADA COMPLIANT FAUCETS 606 Lavatories & Sinks SB-1821-E SB-1821-E-BN SC-3004-FC-LD S-8728-CA-E 606.4 FAUCETS: S-8828-CA-E Faucets shall comply with Section 309. Hand-operated metering faucets shall SB-2011-E SB-2011-E-BN SC-3004-LD-E S-8729-CA-E remain open for 10 seconds minimum. S-8829-CA-E SECTION 309 OPERABLE PARTS: SB-1711-E SB-1711-E-BN SC-3044-LD-E S-9100-CA-E S-9200-CA-E 309.3 HEIGHT: Height ranges as outlined in section 308 of the standard apply. S-9101-CA-E S-9201-CA-E 309.4 OPERATION: Operable Parts shall be operable with one hand and shall SB-1721-E SB-1721-E-BN S-9010-CA-E S-9110-CA-E not require tight grasping, pinching or twisting of the wrist. The force required S-9210-CA-E to activate operable parts shall be 5.0 pounds (22.2 N) maximum. SB-2111-E S-8700-CA-E S-9111-CA-E SPEAKMAN FAUCET SOLUTIONS: SB-2111-LD-BO S-8800-CA-E S-8701-CA-E S-8801-CA-E S-9211-CA-E SC-3084-LD-E S-8710-CA-E S-9112-CA-E Faucets S-8810-CA-E S-8711-CA-E S-9212-CA-E SB-2401 SB-2401-BN SB-1021-E SB-1021-E-BN SC-4072-E-LD S-8811-CA-E S-8712-CA-E S-9117-CA-E S-9217-CA-E S-8812-CA-E S-9118-CA-E SB-2421 SB-2421-BN SB-1311-E SC-4074-E-LD S-8717-CA-E S-9218-CA-E S-9120-CA-E S-8817-CA-E S-9220-CA-E S-8718-CA-E S-9121-CA-E SB-1621-E-PC SB-1321-E SC-5724-E S-8818-CA-E S-8720-CA-E S-9221-CA-E S-9122-CA-E S-8820-CA-E S-8721-CA-E S-9222-CA-E SB-1003-E SB-1003-E-BN SB-1811-E SB-1811-E-BN SC-3002-8-LD-E S-8821-CA-E S-8722-CA-E S-8822-CA-E S-9127-CA-E S-9227-CA-E S-9128-CA-E S-9228-CA-E SC-3004-8-LD-E S-8727-CA-E S-9129-CA-E S-9229-CA-E S-8827-CA-E ADA PRODUCT TRAINING PG. 4 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

ADA BATHTUB COMBINATIONS 607 Bathtubs 607.4 S: Grab bars shall comply with Section 609 and shall be provided in accordance with section 607.4.1 & 607.4.2. There are two types of Bathtubs covered: 607.4.1 BATHTUB WITH PERMANENT SEATS. 607.4.1.1 Back Wall: Two horizontal grab bars shall be provided on the back wall, First one complying with Section 609.4 SHOWER HOSE 15 max. with permanent seats Second located 8 minimum and 10 maximum above the rim of the bathtub. Each grab bar shall be located 15 maximum from the head end wall & extend to 12 maximum from the control end wall. 3-6 18 min. 59 min. 12 max. 24 min. 24 max. without permanent seats 607.4.1.2: CONTROL END WALL: Control end wall grab bars shall comply with Section 607.4.1.2. 8-10 EXCEPTION: An L-shaped continuous grab bar of equivalent dimensions & positioning shall be permitted to serve the function of separate vertical 18 min. & horizontal grab bars. BATHTUB 607.4.1.2.1 HORIZONTAL : A horizontal grab bar 24 minimum in length shall be provided on the control end wall beginning near the front edge of the bathtub and extending toward the inside corner of the bathtub. 607.4.1.2.2 VERTICAL : SHOWER FIG. 607.4.1/2 A vertical grab bar 18 minimum in length shall be provided on the control end wall 3 minimum & 6 above the horizontal grab bar, and 4 inches (100 mm) maximum inward from the front edge of the bathtub. ADA PRODUCT TRAINING PG. 5 Specs are for reference only. Please refer ADA.gov for the latest requirements.

ADA BATHTUB COMBINATIONS 12 max (305 mm) 15 max (380 mm) 607.4.2 BATHTUB WITHOUT PERMANENT SEATS: For bathtubs without permanent seats, grab bars complying with Section 607.4.2 shall be provided. 607.4.2.1 BACK WALL. Two horizontal grab bars shall be provided on the back wall. BACK WALL First one complying with Section 609.4 and the other Control END WALL 24 min (610 mm) 6 (150 mm) END WALL BATHTUB PermANENT SEAT HEAD END WALL Second located 8 minimum and 10 maximum above the rim of the bathtub. Each grab bar shall be 24 minimum in length, located 24 maximum from the head end wall & extend to 12 maximum from the control end wall. 607.4.2.2 Control End Wall. Control end wall grab bars shall comply with Section 607.4.1.2. 4 max (100 mm) FIG. 607.4.1 607.4.2.3 Head End Wall. A horizontal grab bar 12 minimum in length shall be provided on the head end wall at the front edge of the bathtub. 607.5 CONTROLS: Controls (other than drain stoppers) shall be provided on an end wall, located between the bathtub rim & grab bar, & between the open side of the bathtub & the centerline of the width 12 max (305 mm) 24 min (610 mm) 24 max (610 mm) of the bathtub. Controls shall comply with Section 309.4. BACK WALL 607.6 HAND SHOWER: Control END WALL 24 min (610 mm) 6 (150 mm) 4 max (100 mm) END WALL BATHTUB FIG. 607.4.2 SEAT HEAD END WALL 12 min. (305 mm) A hand shower with a hose 59 minimum in length, that can be used as both a fixed shower head and as a hand shower, shall be provided. The hand shower shall have a control with a non-positive shut-off feature. Where provided, an adjustable-height hand shower mounted on a vertical bar shall be installed so as to not obstruct the use of grab bars. ADA PRODUCT TRAINING PG. 6 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

ADA BATHTUB COMBINATIONS Shower/Tub Applications SPEAKMAN SHOWER/TUB SOLUTIONS: SM-X490-ADA-P combinations are intended for shower/tub applications. X in model number above allows you to designate collection, (I.E. 1 is Neo) These bundles include the following (shown in Neo style): SHOWER ARM AND FLANGE, S-2540. HAND SHOWER with Hose and bracket, VS-3010. PAUSE/TRICKLE ADAPTER non-posistive shut-off, VS-156. S-2540 Shower Arm and Flange Bracket VS-3010 Hand Shower with Hose VS-153-ADA Slide Bar ADA SLIDE BAR: VS-153-ADA. Please note an ADA Slide bar is NOT the same as a Grab Bar. The Slide bar ONLY meets the pull force requirement of the ADA Spec. VS-156 Pause/Trickel Adapter ADA Bathrooms still need to have ADA Grab Bars included as the bar needs to be free from obstructions that may prevent someone from being able to grab the bar. DIVERTER PRESSURE BALANCE SHOWER VALVE with integral stops and Valve Trim: the small diverter handle on the valve trim diverts the water to either the hand shower or tub spout. SM-1400-P. TUB SPOUT, S-1557. WHEN TO SPEC: SM-X490-ADA-P Packages: when the project is a shower/tub combination. S-1557 Tub Spout SM-1400-P Diverter Pressure Balance Shower Valve ADA PRODUCT TRAINING PG. 7 Specs are for reference only. Please refer ADA.gov for the latest requirements.

ADA BATHTUB COMBINATIONS Shower/Tub Applications SPEAKMAN SHOWER/TUB SOLUTIONS: There are no pre-packaged combinations for ADA with two shower heads and a tub spout. The following items can be ordered to make up a package (Shown in Neo style): SHOWER ARM AND FLANGE, S-2540. FIXED SHOWERHEAD, S-3010. SHOWER ELBOW connection point for Hand Shower to water supply behind the wall, VS-155. HAND SHOWER with Hose, VS-3010. PAUSE/TRICKLE ADAPTER non-posistive shut-off, VS-156. SLIDE BAR: VS-153-ADA. Please note an ADA Slide bar is NOT the same as a Grab Bar. The Slide bar ONLY meets the pull force requirement of the ADA Spec. S-2540 Shower arm and flange S-3010 Fixed Showerhead VS-155 Shower Elbow S-1183 Transfer Valve VS-3010 Hand Shower with Hose VS-153-ADA Slide Bar VS-156 Pause/Trickel Adapter ADA Bathrooms still need to have ADA Grab Bars included as the bar needs to be free from obstructions that may prevent someone from being able to grab the bar. TRANSFER VALVE, S-1183. DIVERTER PRESSURE BALANCE SHOWER VALVE with integral stops and Valve Trim: the small diverter handle on the valve trim diverts the water to either the hand shower or tub spout. SM-1400-P. TUB SPOUT, S-1557. S-1557 Tub Spout SM-1400-P Diverter Pressure Balance Shower Valve WHEN TO SPEC: when you have an ADA application with both a hand shower and fixed showerhead with Tub. ADA PRODUCT TRAINING PG. 8 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

ADA BATHTUB COMBINATIONS Shower/Tub Applications SPEAKMAN SHOWER/TUB SOLUTIONS: There are no pre-packaged combinations for ADA with two shower heads and a tub spout. The following items can be ordered to make up a package(shown in Neo style): SHOWER ARM AND FLANGE, S-2540. FIXED SHOWERHEAD, S-3010. SHOWER ELBOW connection point for Hand Shower to water supply behind the wall, VS-155. HAND SHOWER with Hose, VS-3010. PAUSE/TRICKLE ADAPTER non-posistive shut-off, VS-156. SLIDE BAR: VS-153-ADA. Please note an ADA Slide bar is NOT the same as a Grab Bar. The Slide bar ONLY meets the pull force requirement of the ADA Spec. S-2540 Shower arm and flange S-3010 Fixed Showerhead VS-155 Shower Elbow S-1183 Transfer Valve VS-3010 Hand Shower with Hose VS-153-ADA Slide Bar VS-156 Pause/Trickel Adapter ADA Bathrooms still need to have ADA Grab Bars included as the bar needs to be free from obstructions that may prevent someone from being able to grab the bar. TRANSFER VALVE, S-1183. PRESSURE BALANCE SHOWER VALVE with integral stops and valve trim, SM-1000-P. DIVERTER TUB SPOUT, S-1558. WHEN TO SPEC: when you have an ADA application with both a hand shower and fixed showerhead with Tub. S-1558 Diverter Tub Spout SM-1000-P Pressure Balance Shower Valve ADA PRODUCT TRAINING PG. 9 Specs are for reference only. Please refer ADA.gov for the latest requirements.

ADA SHOWER COMPARTMENT 608 Shower Compartments: There are several types of shower compartments covered by Section 608. 608.3 S: Grab bars shall comply with Section 609 & shall be provided in accordance with Section 608.3. Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the floor. 608.3.1 TRANSFER-TYPE SHOWERS: Grab bars for transfer type showers shall comply with Section 608.3.1. 608.3.1.1. HORIZONTAL S. Horizontal grab bars shall be provided across 6 (150 mm) the control wall and on the back wall to a point 18 from the control wall. BACK WALL 608.3.1.2 VERTICAL. A vertical grab bar 18 minimum in length shall be provided on the control end wall 3 minimum & 6 maximum above the horizontal grab 6 (150 mm) bar, and 4 maximum inward from the front edge of the shower. 608.3.2 STANDARD ROLL-IN-TYPE SHOWERS: END WALL SEAT END WALL Grab bar shall be provided on the back wall beginning at the edge of the seat. Grab bars shall not be provided above the seat. Back wall grab bar shall extend the length of the wall but shall not be required to FIG. 608.3.2 exceed 48 in length. Where a side wall is provided opposite the seat within 72 of the seat wall, a grab bar shall be provided on the side wall opposite the seat. The side wall grab bar shall extend the length of the wall but shall not be required to exceed 30 in length. Grab bars shall be 6 maximum from the adjacent wall. ADA PRODUCT TRAINING PG. 10 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

with permanent seats ADA SHOWER COMPARTMENT 18 min. 9 min. 12 max. 24 min. 24 max. without permanent seats Fig. 608.3.2 3-6 8-10 608.3.3 ALTERNATE ROLL-IN-TYPE SHOWERS: 6 (150 mm) 6 (150 mm) BACK WALL 6 (150 mm) 6 (150 mm) Grab bars shall be provided on the back wall & the end wall adjacent to the seat. 18 min. Grab bars shall not be provided above the seat. Grab bars shall be 6 maximum from the adjacent wall. 608.4 Controls & Hand Showers: Controls and hand showers shall comply with Sections 608.4 & 309.4. 608.4.1 TRANSFER-TYPE SHOWERS: BATHTUB SHOWER Controls & hand shower shall be located: Fig. 607.4.1/2 1. On the control wall opposite the seat. 2. At a height of 38 minimum and 48 maximum above the shower floor 3. 15 maximum, from the centerline of the control wall toward the shower opening. 6 6 (150 (150 mm) mm) END WALL END WALL GRAB BAR SEAT SEAT BACK WALL FIG. 608.3.3 FIG. 608.3.3 SIDE WALL SIDE WALL 608.4.2 STANDARD ROLL-IN SHOWERS: Controls & hand shower shall be located on the back wall above the grab bar 48 maximum above the shower floor and 16 minimum & 27 maximum from the end wall behind the seat. TOWEL RACK 608.4.3 ALTERNATE ROLL-IN SHOWERS: Robe Hook 42 min. BACK WALL 27 max (685 mm) SPACE FOR HAND SHOWER AND CONTROL 16 max (405 mm) Controls & hand shower shall be located 38 minimum & 48 maximum above the shower floor. In alternate roll-in showers with controls & hand shower located on the end wall adjacent to the seat: Controls & hand shower shall be 27 maximum from the seat wall. In alternative roll-in showers with TOILET controls and hand shower located on the back wall opposite the seat: 40-48 33-36 40-48 SEAT Above Grab Bar 48 max (1220 mm) Controls and hand shower shall be located within 15, left of right, of the centerline of the seat. BATHROOM ADA PRODUCT TRAINING PG. 11 Fig. 604.5.1 FIG. 608.4.2 Fig. 608.4.2 Specs are for reference only. Please refer ADA.gov for the latest requirements.

ADA BATHTUB COMBINATIONS 608.5 HAND SHOWERS: A hand shower with a hose 59 minimum in length, that can be used both as a fixed Shower/Tub Diagram shower head & as a hand shower, shall be provided. The hand shower shall have a control with a non-positive shut-off feature. Where provided, an adjustable-height hand shower mounted on a vertical bar shall be installed so as to not obstruct the use of grab bars. EXCEPTION: In other than Accessible units and Type A units, a fixed shower head located 48 inches (1220 mm) maximum above the shower floor shall be permitted in lieu of a hand shower. SPEAKMAN SHOWERING SOLUTIONS: SHOWER HOSE 59 min. Hand Showers VS-1240 VS-1240-BN VS-1240-E2 VS-1240-BN-E2 VS-3010 VS-3010-BN VS-3010-E2 VS-3010-BN-E2 VS-3011 VS-3011-BN VS-3011-E2 VS-3011-BN-E2 Hand Showers VS-142 VS-145 VS-157 VS-157-BN Other VS-156 VS-156-BN VS-100-PC FIG. 608.5 ADA PRODUCT TRAINING PG. 12 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

ADA SHOWER COMBINATIONS Shower Applications SPEAKMAN SHOWER SOLUTIONS: There are no pre-packaged combinations for ADA with two shower heads. The following items can be ordered to make up a package (Shown in Neo style): SHOWER ARM AND FLANGE, S-2540. FIXED SHOWERHEAD, S-3010. SHOWER ELBOW connection point for Hand Shower to water supply behind the wall, VS-155. HAND SHOWER with Hose, VS-3010. PAUSE/TRICKLE ADAPTER, VS-156. SLIDE BAR: VS-153-ADA. Please note an ADA Slide bar is NOT the same as a Grab Bar. The Slide bar ONLY meets the pull force requirement of the ADA Spec. S-2540 Shower arm and flange S-3010 Fixed Showerhead VS-155 Shower Elbow VS-3010 Hand Shower with Hose VS-153-ADA Slide Bar VS-156 Pause/Trickel Adapter ADA Bathrooms still need to have ADA Grab Bars included as the bar needs to be free from obstructions that may prevent someone from being able to grab the bar. DIVERTER PRESSURE BALANCE SHOWER VALVE Integral diverter allows switching between the fixed and hand held showers, SM-1400-P. WHEN TO SPEC: when you have an ADA application with both a hand shower and fixed showerhead, no tub. SM-1400-P Diverter Pressure Balance Shower Valve ADA PRODUCT TRAINING PG. 13 Specs are for reference only. Please refer ADA.gov for the latest requirements.

ADA SHOWER COMBINATIONS Shower Applications SPEAKMAN SHOWER SOLUTIONS: There are no pre-packaged combinations for ADA when two shower heads are desired. The following items can be ordered to make up a ADA two shower head package: (Shown in Neo style). SHOWER ARM AND FLANGE, S-2540. FIXED SHOWERHEAD, S-3010. SHOWER ELBOW connection point for Hand Shower to water supply behind the wall, VS-155. HAND SHOWER with Hose, VS-3010. S-2540 Shower arm and flange S-3010 Fixed Showerhead VS-155 Shower Elbow VS-3010 Hand Shower with Hose VS-153-ADA Slide Bar PAUSE/TRICKLE ADAPTER, VS-156. SLIDE BAR: VS-153-ADA. Please note an ADA Slide bar is NOT the same as a Grab Bar. The Slide bar ONLY meets the pull force requirement of the ADA Spec. S-1183 Transfer Valve VS-156 Pause/Trickel Adapter ADA Bathrooms still need to have ADA Grab Bars included as the bar needs to be free from obstructions that may prevent someone from being able to grab the bar. TRANSFER VALVE diverts the water from fixed to hand shower, S-1183. PRESSURE BALANCE SHOWER VALVE with integral stops and Valve Trim, SM-1000-P. SM-1000-P Pressure Balance Shower Valve WHEN TO SPEC: this is the direction to go in when you have an ADA application with both a hand shower and fixed showerhead, no tub. ADA PRODUCT TRAINING PG. 14 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

ADA SHOWER COMBINATIONS Shower Applications SPEAKMAN SHOWER/TUB SOLUTIONS: SM-X090-ADA-P combinations are intended for shower/tub applications. X in model number above allows you to designate collection, (I.E. 1 is Neo) These bundles include the following: SHOWER ARM AND FLANGE, S-2540. HAND SHOWER with Hose and bracket, VS-3010. ADA SLIDE BAR: VS-153-ADA, Please note an ADA Slide bar is NOT the same as a Grab Bar. The Slide bar ONLY meets the pull force requirement of the ADA Spec. ADA Bathrooms still need to have ADA Grab Bars included as the bar needs to be free from obstructions that may prevent someone from being able to grab the bar. S-2540 Shower Arm and Flange Bracket VS-3010 Hand Shower with Hose VS-153-ADA Slide Bar VS-156 Pause/Trickel Adapter PAUSE/TRICKLE ADAPTER, VS-156. PRESSURE BALANCE SHOWER VALVE with integral stops and Valve Trim, SM-1000-P. DIVERTER TUB SPOUT: Diverter on spout controls water flow from either the hand shower or the tub spout, S-1558. WHEN TO SPEC: SM-X090-ADA-P Packages: when the project is a shower/tub combination. SM-1000-P Pressure Balance Shower Valve S-1558 Diverter Tub Spout ADA PRODUCT TRAINING PG. 15 Specs are for reference only. Please refer ADA.gov for the latest requirements.

ADA S 609 Grab Bars: Grab bars in accessible toilet or bathing facilities shall comply with Section 609. 609.2 CROSS SECTION: 609.2.1 Circular Cross Section: Bars with circular cross section shall have outside diameter of 1-1/4 minimum & 2 maximum. 609.2.2 Noncircular Cross Section: Bars with noncircular cross section shall have cross section dimension of 2 maximum & a perimeter dimension of 4 minimum & 4.8 maximum. 609.3 Spacing: Space between wall & grab bar shall be 1.5 Space between grab bar & projecting objects below and at the ends of grab bar shall be 1.5 minimum. Space above the bar & projecting objects shall be 12 minimum. 609.5 SURFACE HAZARDS: Grab bars & any wall or other surfaces adjacent to grab bars, shall be free of sharp or abrasive elements. Edges shall be rounded. 609.6 FITTINGS: Grab bars shall not rotate within their fittings. 609.7 INSTALLATION AND CONFIGURATION: Grab bars shall be installed in any manner that provides a gripping surface at the locations specified in this standard & does not obstruct the clear floor space. Horizontal & vertical grab bars shall be permitted to be separate bars, a single piece bar, or combination thereof. 609.8 STRUCTURAL STRENGTH: Allowable stresses shall not be exceeded for materials used where a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener mounting device, or supporting structure. 609.4 Position of Grab Bars 609.4.1 General Grab bars shall be installed in a horizontal position, 33 minimum & 36 maximum above the floor measured to the top of the gripping surface or shall be installed as required by Items 1 through 3: The lower grab bar on the back wall of a bathtub shall comply with Section 607.4.1.1 or 607.4.2.1. Vertical grab bars shall comply with Sections 604.5.1, 607.4.1.2.2, 607.4.2.2 & 608.3.1.1. 1 1/4-2 32 mm - 51 mm 4-4.8 perimiter 100 mm - 120 mm 2 max. 51 mm Grab bars at water closets primarily for children s use shall comply with Section 609.4.2 FIG. 609.2 ADA PRODUCT TRAINING PG. 16 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

ADA S Speakman Grab Bar Solutions: AVAILABLE IN 3 LENGTHS: 24 INCHES, SA-1X09-24 36 INCHES, SA-1X09-36 48 INCHES, SA-1X09-48 SA-1009-24 Neo Polished Chrome * Custom lengths available per request TWO STYLES: NEO, SA-1009-XX RAINIER, SA-1309-XX TWO FINISHES STANDARD: SA-1309-24 Rainier Brushed Nickel POLISHED CHROME BRUSHED NICKEL, -BN * Specialty finishes available per request ADA S SA-1009-24 SA-1009-24-BN SA-1009-36 SA-1009-36-BN SA-1009-48 SA-1009-48-BN ADA S SA-1309-24 SA-1309-24-BN SA-1309-36 SA-1309-36-BN SA-1309-48 SA-1309-48-BN ADA PRODUCT TRAINING PG. 17 Specs are for reference only. Please refer ADA.gov for the latest requirements.

For additional assistance or service please contact: SPEAKMAN Company 400 Anchor Mill Road New Castle, DE 19720 800-537-2107 customerservice@speakman.com www.speakman.com