YOUR WISHES SET OUR STANDARDS. Retractable BOLLARD

Similar documents
better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Order No Projection Backboard

Product Range Trench Shoring.

10.2. Basketball Single Post System

ASSEMBLY AND OPERATING MANUAL LTW SHORING BOXES VB 100 & VB 120

ASSEMBLY AND OPERATING MANUAL LTW MAXI TRENCH BOX

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

10.2. Basketball Single Post System

Extension Platform. Base Platform. Crossover. Exit railing. Exit Railing

ASSEMBLY AND OPERATING MANUAL LTW SHORING BOXES VB 60

USER MANUAL. Beach volleyball posts BEACH CHAMP ID:

ORG. Application example. Special Grippers O-ring Assembly Gripper. Weight 1.35 kg. Ring diameter O.D. Assembly appr.ø 5 mm.. ø 160 mm.

Product Information. Gripper for small components MPC

TECHNICAL INFORMATION

PFH. Application example. Pneumatic 2-Finger Parallel Gripper Long-stroke Gripper. Weight 2.65 kg 12.6 kg. Gripping force 630 N 2950 N

built build to TRENCHLINING DOWN A CAISSON

Draw-wire system SZG165

Type 4708 Supply Pressure Regulator

AutoDrill s OUTSTANDING FEATURES

Poollift Delphin. Version: February, 2015 MANUAL AND OPERATING INSTRUCTIONS

Product Information. Gripper for small components MPG-plus 16

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

ELADOS EDP L Diaphragm Metering Pump Type

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Preferred Instruments Danbury, CT USA

Splitting cylinder C20

Product Information. Gripper for small components MPG 20

9A5N Solid State CW Paddle

PFH. Application example. Pneumatic 2-Finger Parallel Grippers Long-stroke Grippers. Sizes Gripping force 510 N N

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

Float operated valve TYPE (SWDS)

SPG. Application example. Pneumatic 2-Finger Parallel Gripper Heavy-load Gripper. Weight 35 kg. Stroke per finger 100 mm.

Gripping rotary modules

GWB Pneumatic 2-Finger Radial Gripper Universal Gripper Sizes Weight Gripping moment Opening angle per finger Workpiece weight

Squeegee Unit for MRS Multi-Recovery System

Oxymax COS61/COS61D. Technical Information

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Type 4708 Supply Pressure Regulator

High flow rate. Cost effective. Compliant. Gripper with GSW-B Shaft Interface and Compensation Unit

Pneumatic spool valve islands

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

LGP. Application example. Pneumatic 2-Finger Parallel Gripper Universal Gripper. Sizes. Gripping force 26 N 1090 N. Weight 0.03 kg 1.

Plankton pump Model ,2 KWatt. Manual. KC Denmark. Research Equipment Limnology Oceanography Hydrobiology

Millennial Walker A multi-functional, elderly assistance walker with improved posture, comfort, and folding capabilities.

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

DX2/DXX Operating Instructions

LGZ. Application example. Pneumatic 3-Finger Centric Gripper Universal Gripper. Sizes. Gripping force 120 N 1470 N. Weight 0.1 kg 0.

MoveRoll Conveyor Operating and Maintenance Manual

Data Distribution Cabinets. Exclusive CD edition March 2006

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

2010 International Snow Science Workshop

Relay Judging Platforms with Speedlights

MPG-plus. Application example. Pneumatic 2-Finger Parallel Gripper Gripper for small components. Gripping force 38 N 175 N. Sizes

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Flamco Flamco-Fill STA Flamco-Fill STM

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

1000/13.02 KOBSERT. Thread inserts for metals

OUS31. Technical Information

LGR. Application example. Pneumatic 2-Finger Radial Gripper Universal Gripper. Sizes. Gripping moment 0.3 Nm 15 Nm. Weight 0.07 kg 1.

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

14. Exploded View. Page 68

SWG. Application example. Pneumatic 2-Finger Angular Gripper Angular Gripper for Small Components. Sizes Gripping moment 0.01 Nm.. 2.

PHOENIX, ARIZONA USA

PGN. Application example. Pneumatic 2-Finger Parallel Grippers Universal Grippers. Gripping force 100 N N. Sizes

Low Wind High Yields Series

GAS PRESSURE CONTROL UNIT TYPE 132

Pneumatic Gripping Modules. Pneumatic 2-Finger Radial Grippers

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

GENO -Flushing Compressor Product Data Sheet F 02

INSTRUCTION MANUAL Pressure Relief Device LPT

American Flagpole & Flag Co. 1(800)

PWG-S. Application example. Pneumatic 2-Finger Angular Gripper Universal Gripper. Sizes. Gripping moment 5.98 Nm Nm. Weight 0.21 kg 1.

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Installation and Training Manual

Technical Information Cleanfit CUA451

Sizes Weight Gripping force Stroke per finger Workpiece weight Pieces : kg N mm kg

Side-of-Pole Mount for 1 Module (SPM1) For Module Type C

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

Technical Data Sheet MF010-O-LC

CONDITIONS OF SALE AND WARRANTY

LGP Pneumatic 2-Finger Parallel Gripper Universal Gripper Sizes Weight Gripping force Stroke per finger Workpiece weight

RG2 Gripper Datasheet Version 1.6

Designing Wave Energy Converting Device. Jaimie Minseo Lee. The Academy of Science and Technology The Woodlands College Park High School, Texas

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Laboratory Mortar Mixer (Testing)

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel

MODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual

MAINTANCE MANUAL CNC ROTARY TABLE MODEL: DMNC-5C YUASA INTERNATIONAL.

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

L.Ph. Bolander & Sons 1355 Evans Ave. 800/

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

Transcription:

YOUR WISHES SET OUR STANDARDS Retractable BOLLARD

GIFAS bringt den automatisch versenkbaren Poller für die kontrollierte Zufahrt im öffentlichen und privaten Bereich auf den Markt! The retractable bollard can be used to prevent driving or parking in certain areas such as walking or biking paths, pedestrian zones, private property or parking spots, etc., while allowing for free access for pedestrians. Technical data Surface Drive Velocity Operating voltage Protection rating Load class Weight Bollard unit Stroke special steel, stainless, brushed Electromechanical (Gear motor with spindle) ca. 10cm / sec. 24VDC IP65 C250 Total weight: 250 kg (incl. concrete pipe, excl. control system) Retractable bollard: 36kg Ø 206 mm 600 mm GIFAS Retractable Bollard Description The retractable bollard systems are impressive thanks to their well-designed appearance as well as simple handling and maintenance. When they are fully extended, they reliably hold back through traffic as well as parking traffic, while allowing unhindered access to pedestrians, bicycles and wheelchairs. Construction A complete installation / system basically consists of the applicable bollard unit (with electromechanical drive), electrical control system and cable connection between them. The installation is reliable, user-friendly and low-maintenance. The electrical control system is built into a separate housing und only requires connection to the 230V network in its basic configuration. Communication with the bollard is provided through the connecting cable. Function of Spindle Lifting Drive The gear motor mounted on the base plate drives a vertically supported spindle As the spindle rotates, the bollard is lifted by the spindle nut Function in the event of a power outage: with a load of approx. 50 kg, the self-locking mechanism of the spindle can be over come (lowering without tools or Accu). Cylinder Construction Two-part cylinder liner, upper and lower part (Wall thickness: 3mm) Cover with built-in LED operating light and security monitoring Predetermined breaking point Appropriate sliding points (adjustable) are installed in the lower part for accurate guidance 1. Bollard Unit Construction 2. 1 LED warning light 2 Retractable bollard 3 Stainless steel cover 4 Junction box 5 Sliding guides 6 Concrete pipe (Ø 400mm) 7 Spindle 8 Connecting cable 9 Guide cage 10 Motor 11 Position switch TOP 12 Position switch BOTTOM 13 Main control system 14 Predetermined breaking point 13. 3. 4. 5. 6. 7. 8. 9. 10. 14. 11. 12. 2 GIFAS-ELECTRIC GmbH Pebering-Straß 2 5301 Eugendorf near Salzburg AUSTRIA

Safety Components Collision Protection Close Range A field is effective for collision protection within a close range of 20-40 cm. The smallest, slowest movements can be detected within this range. Static objects (e.g. a car parked over a bollard) are thus detected. Collision Protection Long Range A field is effective for detecting movement up to approx. 2 m. Fast movements are detected within this range. Approaching objects (e.g. cars, pedestrians) are thus detected. The size of the protection field can be set on the control system. Security Lighting In order to increase visibility, the bollard is equipped with an orange LED light (CircLED) as standard design. The light operates continuously when the bollard is fully extended, and it blinks as the bollard is raised and lowered. Sollbruchstelle This is a distinguishing feature of the GIFAS retractable bollard. The connection between the upper and lower parts may vary in the number of screws (4 12 ea.) and in the quality of these screws (nylon - steel). This makes it possible to define the degree of safety or the damage caused by a collision through and on the bollard itself. Security through Radar Monitoring Long Range Collision Protection Close Range Collision Protection LED Warning Light Light emission with a coverage of over360 45 *20-40 cm 20 *A d j u s t a b l e d i s t a n c e Predetermined Breaking Point *2 m 3 0 3 0 1 Upper part 2 Lower part 3 Spindle nut 4 Disk 5 Hex screws (Quantity of 4-12 ea., Quality: Nylon or Steel) 5. 1. 4. 3. 2. *A d j u s t a b l e d i s t a n c e Telephone: +43 6225 / 7191-0 Fax extension: 561 www.gifas.at office@gifas.at 3

Completely Newly Developed Bollard System Basic Functions Pulses are transferred to the bollard control system (two potential-free contacts) from a master control system or corresponding switching and signaling devices. They are implemented as commands for extending and retracting the bollards. Distinguishing Features of the GIFAS Retractable Bollard System Required structural preparation is very simple Fast and easy installation Scope of delivery: bollard, stainless steel cover, bollard control system, connecting cable Open to all master monitoring and control modules Bollard Extension Procedure The LED warning light starts blinking to indicate that a moving operation has been triggered. This movement is monitored by radar sensors in the cover. If an obstacle is detected within the monitoring area, the movement is immediately reversed. An impact pressure monitoring system is also active and will react to any mechanical obstruction. The process of raising the bollard can be overridden at any time by the command to lower it. Bollard top view direction of motion survey radar sensor Bollard Retraction Procedure This moving operation is also indicated by the blinking of the LED warning light. This process is not monitored by radar. If the retraction process is obstructed early on, an error message is displayed on the control system. 510 Radarsensor Radarsensor ø206 Marker light Fully-Extended Bollard Ø206 510 Extended Status In order to ensure better visibility, the LED-operation indicator is continuously lit in this position (very low power consumption). The cylinder cannot be pushed in manually because the spindle is under continuous pressure. Retracted Bollard Retracted bollard stainless steel 600 510x510 1100 1030 Retracted Status Any indication of this status is unnecessary, which is why the LED warning light is turned off. finished floor level stainless steel frame Concrete pipe Retracted bollard Concrete shaft Ø400 Ø510 4 GIFAS-ELECTRIC GmbH Pebering-Straß 2 5301 Eugendorf near Salzburg AUSTRIA

The Basic Principle Control Module (provided by customer) Bollard Control System (incl. power pack in all rubber box) Connecting Line GIFAS Command Controller (provided by customer) Cable Connection (provided by customer) GIFAS Retractable Bollard incl. Junction Box Our Scope of Supply Description GIFAS Retractable Bollard, incl. guide cage, junction box, concrete pipe, stainless steel cover Bollard control system, power pack in all rubber housing Plug-in connector for bollard, connected to connecting line Gifaflex 20x1mm² black - 2 to 30m Caulking tools, compl. set Bollard blind cover, incl. locking bar Retractable bollard extended with constantly lit LED power indicator Retractable bollard while retracting with flashing LED power indicator Telephone: +43 6225 / 7191-0 Fax extension: 561 www.gifas.at office@gifas.at 5

Preparations On Site Step 1: Dig out an excavation pit Step 2: Put in a soak away pit, incl. drainage Step 3: Lay out an installation pipe for supply line Step 4: Determine the location for the bollard control system and ensure there is mains connection (230V) Step 5: Make sure operating parts and the installation for automation are provided. Note for Installation: Any groundwater must be drained through the drainage system. Place the cable connection under the frame of the bollard (measuring 1000 mm). Montage / Einbau des Senkpollers Schritt 1: Verbindungsleitung einziehen Schritt 2: Steckkupplung anstecken Schritt 3: Senkpoller in Betonrohr absenken Schritt 4: Verstemmen des Senkpollers mit entsprechendem Werkzeug Schritt 5: Edelstahldeckel aufsetzen und verriegeln mit entsprechendem Werkzeug Schritt 6: Verbindungskabel an Pollersteuerung anschließen Optional: Bei Bedarf Steuermodule für die Automatisierung montieren und anschließen Specifications Concrete pipe Inst. pipe Cast frame DN400 mm x 1000 mm min. diameter M25 special stainless steel frame and stainless steel cover for bollard Tolerances Tolerances for perpendicular concrete pipe: +/- 5 mm to 1 m depth Tolerances for levelness of stainless steel frame: in the lead Concentricity of the stainless steel frame / concrete pipe: +/- 2.5 mm Components 1. 2. 3. 1 Ground cover 2 Stainless steel frame 3 Stainless steel cover 4 Mortar 5 Concrete pipe 6 Inst. pipe for the control cable 7 Perforation in the concrete pipe 8 Soil 9 Soak away pit / drainage system 10 Position switch (Inputs UP, DOWN ) 1000 4. 5. 6. 7. 10. 8. 10. min. 1100 9. 6 GIFAS-ELECTRIC GmbH Pebering-Straß 2 5301 Eugendorf near Salzburg AUSTRIA

GIFAS-Fixed bollard Ø204 3-Edge 8 mm Ø204 139 Ø12 600 Ø204 Ground sleeve from front 305 305 600 finished floor level Ø320 Ø320 Bollard from top Bollard from bottom To assemble appropriately stainless steel screws have to be used! Ground sleeve from top 215 Bollard from top Ø204 Often it is the case by larger lots and driveways that it is not necessary, respectively does not make sense, to operate over the entire width with retrectable bollard, but besides some retrectable bollard equip the rest of the width with fixed bollards. For these cases, we have developed two standard types of fixed bollards that can be used as required. Fixed bollard top This bollard, leaning in appearance to the GIFAS retrectable bollard, you can close off surfaces and spaces, without great expense - structurally and financially. The fixed bollards usually used as an addition to the automatic bollards. The version fixed bollard is placed directly on the floor and screwed! Fixed bollard technical data Stainless steel Material A2 1.4301 Pipe diameter 204 mm (Ø) Wall thickness 2 mm Hight over ground 600 mm (H) Surface K220 polished ATTENTIOÄN! The gap between the bottom and sleeve bollards must be maintained. Fixed bollard use variable 215 Also, the bollard use variable, which in appearance is aligned to the GIFAS retrectable bollard, is generally used as a supplement to automatic bollards. On the ground a ground socket (aluminum) is embedded, in which the variable bollard is inserted. By means of closure 3-edge -8 mm, it can be secured. Telephone: +43 6225 / 7191-0 Fax extension: 561 www.gifas.at office@gifas.at 7

CONTACT US Subject to technical changes V03/2015 GIFAS-ELECTRIC GmbH Web: www.gifas.at Pebering-Straß 2 Mail: office@gifas.at 5301 Eugendorf Tel.: +43 6225 / 7191-0 AUSTRIA Fax: +43 6225 / 7191-561