Bobtail DOT 407 / 412 Vacuum

Similar documents
SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

GAS COMPRESSION SYSTEM

PRESSURE ADJUSTMENT Main pressure adjustment

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

Model Air Caddy Orig TABLE OF CONTENTS

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

OPERATION MANUAL NTF-60 Plus

MANUAL BE SERIES Test Benches

OPERATION MANUAL NTF-15

COMPRESSOR REPLACEMENT PROCEDURE (R-134A)

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

Portable Oil Lube Air Compressors

HOT OILING OPERATIONS ALL HSE PRC 172. Approved By: Manager, HSE Performance Assurance. Table of Contents

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

NORMAL OPERATING PROCEDURES Operating Parameter Information

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

STREAMLINE SHOP SERIES MODEL OPERATION & PARTS MANUAL

CHAPTER 26 WELDING AND CUTTING

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

STREAMLINE SHOP SERIES MODEL 30040V OPERATION & PARTS MANUAL

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

OPERATING AND MAINTENANCE MANUAL

MEGR-1912 Instruction Manual

2.0 INSTALLATION & SERVICE

LNG Regulator Test Kit

Hydraulic Reliability & Preventive Maintenance Report

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Pressure Dump Valve Service Kit for Series 3000 Units

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Vacutrans Instructions

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

AIR DRIVE ROLL FEED CARTON STAPLER MODEL: H-1031 MANUAL

Safe Work Instructions For Oxygen Acetylene Equipment

Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices. Unit Objectives. Pressure Vessels and Piping (1 of 2)

Section 35 Brieser Construction SH&E Manual

Mobile Breathing Air Systems

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

T1-Titanium HVLP Siphon Feed Spray Gun

Types S100K and S102K Pressure Regulators

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

WHEELED AIR COMPRESSOR AC658HB AC708RB AC908HB AC6520HB. User Manual

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

WATER CONTROL SYSTEM QUICK START

Pneumatic Powered - Plunger Pumps

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

RecoverXLT2-AP Oil-Less Universal Refrigerant Recovery System Operation and Maintenance Manual

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

CNG/LPG Vehicles Emergency First Response Guide

Air Consumption Recommended Usage Siphon Feed

8-GALLON AIR-OPERATED OIL CHANGER

Before Leaving the Plant

AC558RB AC7011RB. operation manual

Types 749B and R130 Changeover Manifolds

Copyright, 2005 GPM Hydraulic Consulting, Inc.

LIQUID OXYGEN. General. Health Effects. Safety Considerations

MODEL NUMBER: P PORTABLE COMPRESSOR

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

Eaton Filtration, LLC

NTF-515. Operation Manual

CALIFORNIA STATE RAILROAD MUSEUM

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

VERTICAL AIR COMPRESSORS

INTENDED USE TECHNICAL SPECIFICATIONS

Part IV: Troubleshooting

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

BUTTERFLY VALVES Series 800

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

SECTION P4 SEPARATION SYSTEMS

Suggested Installation & Operating Instructions for Sidewinder Pumps

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

3/8" Dr. Air Butterfly Impact Wrench

KJ4000 Operating Instructions & Parts Manual NSN

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

SCK01 AIR COMPRESSOR KIT WITH QUICK FITTINGS - SPRAY/BLOW/OIL GUN, TYRE INFLATOR & HOSE

III. Identify the initial installation requirements for standpipe systems

Section 20 TABLE OF CONTENTS Pressurized Equipment and Systems. 20.A General B Compressed Air and Gas Systems

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

The X-11 Molding Chamber

Advanced Fluid Handling Cart Owner s Manual

HYDROGEN PEROXIDE Railcar Unloading by Self-Priming Pump Technical Data Sheet

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

PC 1010 Electric Air Compressor

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

Transcription:

PROCO INCORPORATED AUGER OPERATION Manual Bobtail DOT 407 / 412 Vacuum

Vacuum Tank Operation This vacuum tank has been built for Dot work. Extreme care must be exercised regarding product handling. The unit is equipped with a 4" pressure relief valve located near the internal scrubber dome or portal shutoff, and should always remain in good operating condition. VACUUM PUMP OPERATION: 1. Place 3" fourway valve on vacuum pump in proper position for vacuum or pressure (NOTE WARNING ON FLAMMABLE / COMBUSTIBLE MATERIALS) be aware of fumes. Make sure external scrubber blow-down valve is closed (outside scrubber valve located on front fender beneath scrubber. 2. Check Oil level in vacuum pump. Oil catch muffler should be drained daily. If foreign material is found preform a through tank scrubber system inspection. Inspect pump for any physical damage. 3. Push selector valve in on driver s side of fender from vacuum pump operation. 4. Start vacuum pump by slowly engaging PTO on truck and set at proper RPM (see decal on truck dash). Pump will start either pulling a vacuum or pressuring the tank depending on location of pump valve setting. Upon reaching the desired pressure or vacuum, open the rear 4" valves thus allowing fluid to flow. Continue until operation is complete. NOTE: Rotary vane pumps have a minimum and maximum RPM. Always read pump manufacturers manual for operation procedures and safety warnings.

SCRUBBER OPERATION: The trailer is equipped with an inside shutoff and an external scrubber. These scrubbers are there to prevent liquid from entering the vacuum pump. The scrubber & shutoff have a 6" stainless steel float ball, and a 3" Buna seat. Both must be in good condition to protect the vacuum pump. Any liquid entering the external scrubber will be caught and must be drained out the blow down valve. A sizable amount drained (quart or more) indicates a problem with the float ball or seat in the inside shutoff and should be corrected. External scrubber should be drained daily in the pre- trip inspection. Any liquid drained from the scrubber is tank product and must be handled accordingly. Remember the vacuum pump is an air compressor & not a liquid pump. Liquid will do major damage. PUMP TROUBLE SHOOTING: 1. UNIT WILL NOT PULL VACUUM - Check 4 way valve for proper position. Check liquid level in tank, float balls will shutoff airflow on high level. Check vacuum pump valves. Check manway lids and gaskets for air leaks. Inspect for collapsed internal hose liners. 2. PRODUCT WILL NOT DISCHARGE FROM TANK - Check position of rear 4" valve. Check for obstructions down stream of vacuum tank and in outlet valve. Follow your company procedures for clearing solids from valves. Safety: 1. Your unit is equipped with a relief valve set at the working pressure of the tank. This valve is never to be removed, plugged or reset unless performed by a qualified shop. 2. DO NOT release suction or discharge until all personnel are in a safe position i.e. not directly behind outlets or near hoses. 3. DO NOT exceed maximum rpm, or go lower than the minimum rpm on the vacuum pump. 4. DO NOT load unit in excess of maximum carrying capacity of truck. 5. Suction / discharge valve(s) to remain closed at all times except while loading or unloading.

6. Whenever entering tank be aware of most recent commodity hauled, check for toxic fumes and always have adequate ventilation. Never enter a tank without proper protective clothing and breathing air. If vapors inside tank are combustible, do not enter tank with ignition source this will cause an explosion. Always follow your company Confined Space Procedures. 7. Never place hand in proximity of suction or discharge line on pump or vacuum tank. 8. Do not release hatch bolts/ wingnuts until all pressure has been removed, i.e. open blow down lines. Loosen four of six wingnuts without moving wingnuts to clear lid. Should lid stick to gasket and tank be pressurized, this should prevent lid from blowing open. With no pressure, loosen all wingnuts, slightly move lid to ensure it is free and there is no pressure in the tank. Swing wingnuts out of lid and open lid. Always keep your body (face and limbs) free from lid while opening lid to prevent injury in case of lid blowing open. 9. Your vacuum pump oil catch muffler is equipped with a cam fitting allowing you to hose the exhaust gases into a low-pressure recovery system or down wind & away from the equipment and personnel. Remember the gases could be combustible or harmful if breathed.

Tank Tilt Operation: 1. Pull selector valve out on driver s side of fender for tank tilt operation. 2. Make sure all obstructions and hazards are removed from tanks tilt up or downward path. 3. Slowly engaging PTO on truck and set at proper RPM (see decal on truck dash). 4. Use tank tilt valve to either raise or lower tank. 5. Do not release rear cleanout hatch bolts/ wingnuts until all pressure has been removed, i.e. open blow down lines. Loosen four of six wingnuts without moving wingnuts to clear lid. Should lid stick to gasket and tank be pressurized, this should prevent lid from blowing open. With no pressure, loosen all wingnuts, slightly move lid to ensure it is free and there is no pressure in the tank. Swing wingnuts out of lid and open lid. Always keep your body (face and limbs) free from lid while opening lid to prevent injury in case of lid blowing open.

Auger Operation: The Auger controls consist of 2 main hydraulic controls: 1. Directional control is a three position lever which will control the rotation of the auger. Engage the lever in the furthest up position will push the product to the front of the trailer usually used for loading and transporting the product. The middle position is used for startup and is used no auger rotation is desired. The lowest position pushes product to the back, usually used for unloading. 2. Swing control is a 2 position push pull valve to engage swing. It will stop the swing, or will engage swing. Startup: 1. Check engine oil and hydraulic fluid levels 2. Make sure all obstructions and hazards are removed from auger path. 3. In Auger control box, place directional control valve in neutral position, and push auger swing valve in. 4. Turn ignition key on diesel engine to start 5. Check engine gages have reached operating conditions (about 5 seconds) 6. Engine rpm should be 1300 rpm s. 7. In Auger control box, engage swing and rotation and begin loading product into tank. 8. Auger hydraulic pressures should show 1200psi on both the swing and auger gauges. Operating: 1. When operating under normal conditions the auger should rotate at approximately 60 rpm and the swing should take 50 to 60 seconds to complete one full cycle. 2. If the rotation stops and will run momentarily if you change rotation before locking up again, the chain box is worn and must be serviced. 3. If the swing oscillates rapidly across a short section of the tank either the product has solidified, or hydraulics are out of adjustment and need servicing.

Caution and Warning Decals: Always follow all caution and warning decals. Parts and Service: Contact Proco Inc 700 Proco Trail Kingsville, TX 78363 800-864-4887 361-516-1112 Fax 361-516-1105 Email parts@procofab.com