LOGIC RANGE AUTOMATIC PRESSURE

Similar documents
LOGIC RANGE AUTOMATIC PRESSURE REDISTRIBUTING SySTEMS

NIMBUS range. with people in mind

PRESSURE REDISTRIBUTION SYSTEM. with people in mind

LIFECOMFORT ACTIVE AIR

NIMBUS 4 NIMBUS PROFESSIONAL

Precioso series 2. Prevention and therapy for everybody, everyday NURSING-CARE HEALTHCARE

Contents. Introduction...1 About Breeze... 1 Breeze Overlay... 2 Breeze Mattress Replacement... 2 Breeze Pump... 4 Controls and Indicators...

Domus series. Pressure Redistribution System

NIMBUS 3 NIMBUS 3 PROFESSIONAL

OptiCare. Optimising patient care

Pegasus Aircare Mattress Overlay System Models 2200 and 2201

ALPHAXCELL. Active pressure relieving mattress overlay system for medium risk patients in all environments

User Manual. 10. Dimensions and Ordering Codes. Integrity Alternating Pressure Mattress System. Alternating Pressure Mattress Systems

Performance Redefined. Automatic Gas Control (AGC) FLOW-i Anesthesia Delivery System

Air Plus User Manual

2015 Products Catalog Product Catalog. Products designed for the treatment and prevention of wounds

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax:

Foam Mattress & Cushion Range

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

Autom ate d t u r n i n g at yo u r f i n g e r t i ps

Seating Systems. The Company. Park House

USER MANUAL. AltaDyne XT Model A AltaDyne XD Model A Alternating Pressure / Low Air Loss Replacement Mattress System

INTRODUCING CARDIOSAVE Hybrid MORE THAN A PUMP. A REVOLUTION. SPECIFICATIONS

BATHING SOLUTIONS FOR THE CENTRAL BATHING AREA

SySTEm Flow chart ANESTHESIA patient connection

EVERYONE KNOWS WE WORK BEST UNDER PRESSURE. + WE CAN HANDLE MOISTURE TOO. ROHO S/A

How did we design such a revolutionary alternating pressure mattress system?

Paradise Pump Series Operator s Manual

Symbioso 200. Integrated air surface for Multicare hospital bed HEALTHCARE

User Manual DIRECTHEALTHCARESERVICES.CO.UK

PARKER HEIGHT-ADJUSTABLE RECLINING SIT BATH

AltaDyne AutoFloat. Alternating Pressure Management Plus. Model # Model # OPERATORS MANUAL

Operator s Manual. Dynamic Low-Air-Loss Therapy with Alternating Pressure

UK RBF Bath buddy instruction 16pp 21/9/07 09:07 Page 1. Bath-Buddy / Bathmate Instruction Book

RIK Fluid Overlay INSTRUCTIONS FOR USE

User Guide Antidecubitus systems EURO BASIC

Adult Pressure Care. Star Cushion. High Performance Air Cell Cushions

System Flow Chart. ventilation patient connection

APH166 Morpheus Air USER MANUAL. Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF.

User Manual. Version 1.2 July 2015 Pg. 1

770000S CLINICAL MAX LOW AIR LOSS WITH ALTERNATING PRESSURE SYSTEM USER MANUAL

E V E RYONE K N OW S WE WORK BEST P R E S S U R E. + MOISTURE TO O. RO H O

User Manual. soft air simplex wds. Health. Security. Independence. Pressure ulcer prevention and treatment-system Assembly and Operation instructions

Instruction Manual for Configura Cushionair Portable Pump

PRESSUREGUARD APM OWNER S MANUAL. PressureGuard APM Bariatric. Span-America Medical Systems, Inc. Greenville, SC

Tourniquet Systems Pressure Infusion

PARKER. with people in mind

Pressure Ulcers ecourse

User-Service Manual Joerns Healthcare Advanced Wound Care Integrated Bed System DolphinCare Fluid Immersion Simulation with UltraCare XT

Digital Tourniquets. Product Details. For electricity VAC, 50/60 Hz

Warranty The device shall have a 6-year warranty at minimum

Dynamic pressure system for pressure relief

MA90 Series Mattresses. MA95 Series Mattresses

Key Product Features. Primary Use: Aggressive Treatment of Pressure Ulcers

SELECT SERIES LS200 ALTERNATING PRESSURE / LOW AIR LOSS MATTRESS SYSTEM

Panacea AIR PRO MATTRESS. Owner s Manual. Please keep and refer to this Owner s Manual.

User Manual soft air wds

Lateral Turning System. User Guide.

User Manual DIRECTHEALTHCARESERVICES.CO.UK

Bath Buddy / Bathmate Instruction Book

Interface Pressure Testing as an Alternating Pressure Surface

LifeChoice Activox Portable oxygen concentrator. Portable oxygen therapy for patients with active lifestyles. ResMed.com

QUADROX-i Neonatal & Pediatric Maximum safety for the smallest patients.

PressureGuard Custom Care Convertible LAL. Series

Joerns Healthcare. transforming wound management. User-Service Manual TriLine Support Surface. To avoid injury, read user s manual before using.

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control

User-Service Manual Joerns Support Surface FlapCair. To avoid injury, read user s manual before using.

QubiCell series. QubiCell series. QubiCell series. Pressure Redistribution System Comprehensive Care - Ultimate Comfort

Actively supporting your health.

Tourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management

EasySas. The most advanced airlock electronics on the market. Recyclable product. Eco-design. Energy savings

Arise 1000EX Low Air Loss Therapy Mattress. Operations/Maintenance Manual. Model 2236

TEMPUR-MED OPERATING TABLE MATTRESSES AND POSITIONING PRODUCTS.

Alternating Pressure / Low Air Loss Mattress System

Tourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management. AT4 Tourniquet System. Introduction.

(DynaLaL III) Dynamic True Low Air Loss Mattress Replacement System

SALISBURY ACTIVE OVERLAY SYSTEM

Digital Display large color coded LED display is easy to read precise measuring shows actual cuff pressure

CARDIOHELP System designed to save lives

Invacare Therapeutic Support Surfaces Catalog

DYNAMIC COMPRESSION THERAPY

SELECT SERIES LS300 ALTERNATING PRESSURE / LOW AIR LOSS MATTRESS SYSTEM

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

Rapid Response Shelters. Rubber Product Manual

Harvest Healthcare Clinical Evidence. P161M - Viscoflex Mattress P161MOE - Viscoflex Evolutive Mattress

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

AIRCARE INTERNATIONAL Unit 3, Shannonside Business Park, Birdhill, Co. Tipperary,Ireland Tel : +353 (0) Fax : +353 (0)

CLPNA Pressure Ulcers ecourse: Module 5.2 Quiz II page 1

PressureGuard APM 2 and PressureGuard APM 2 Safety Supreme

FOCUS - ON - PATIENTS

PERFUSION SYSTEMS MECC SMART SMART SUCTION SYSTEM

Full face benefits in a compact size

Med Aire Alternating Pressure Pump and Pad System

Automatic Isokinetic Sampler. ST5 Evo

OxygenatOrs QUaDrOx-i adult QUaDrOx-i small adult

MEET THE SIPABOARD SIPABOARDS FIRST ELECTRIC, SMART, SELF-INFLATING AWARD WINNING STANDUP PADDLE BOARD.

WELCOME TO THE REVOLUTION

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

AutoChanger Installation & User Guide Issue 2

Transcription:

LOGIC RANGE AUTOMATIC PRESSURE REDISTRIBUTING Systems with people in mind

Mattress Replacement & Overlay Systems The Auto logic 200 mattress replacement and Auto logic 110 overlay systems are part of the logic range from ArjoHuntleigh. Leading edge technology provides automatic, self setting mattress replacement or overlay options with battery-powered active transport facility. The complete Auto logic range includes the Auto logic 175 mattress replacement and Aura logic seat cushion, and is recommended for round-the-clock prevention and management of all categories 1 of pressure ulcer when combined with an individualised monitoring, repositioning and wound care programme.

Revolutionary Self Set Technology Forget about adjusting pump settings during installation. For optimal pressure area management, the Auto logic pump uses Self Set Technology (SST) to control the mattress pressure. In Active 1 Therapy (Alternating) and Reactive 1 Therapy (Constant Lower Pressure) modes, an advanced microprocessor system regularly assesses the body mass distribution of patients and readjusts cell air pressures to suit their individual requirements.

Unique Mattress Construction Cover Options Standard Cover - for general use Advantex Cover - offers lower friction and higher moisture vapour permeability event Fabric Cover - for patients requiring an air permeable surface Concealed Zips Proactive approach to infection control Cell Retainers Unique cell securing hooks that replace existing poppers Proactive approach to infection control and mattress servicing Curved Cell Design Prevents patient creep down the system Cell in Cell (CIC) System Centralises patient on the mattress Increases stability of edge to aid transfer off and on the surface

Leading Edge Technology Micro Air Loss Helps reduce humidity at the patient - mattress interface CPR Control Rapid deflation to assist resuscitation Simple one handed operation Positioned at head end Cable Management No trailing power cables AutoFirm mode Allows the mattress to be pumped to a steady high pressure to allow nursing procedures that require a firmer base to be performed.

Leading Edge Technology Battery Offers a minimum of 6 hours of therapy in the event of a power cut or active transport to operating room or X-ray department. Transport Facility Simple operation via disconnection from the tubeset. Cell pressure automatically equalises out. Provides patient support for up to 12 hours on a mattress. Anchor Points and Securing Straps Moulded and welded to non-slip base material. Improves patient safety and provides secure fastening to varying frames and seats. 24 hour Peace of Mind The Aura logic seat cushion provides roundthe-clock prevention and management of pressure ulcers, when used in combination with the Auto logic systems. For ease of use, the Auto logic pump automatically recognises which system has been connected.

10 8 1 6 7 5 9 2 4 3 Two Therapies in One Pump Multi-mode pump offering leading pressure management therapies: Active 1 Therapy (Alternating) mode Reactive 1 Therapy (Constant Lower Pressure CLP) mode 1 2 3 4 5 Run/Standby Button Switches pump unit on and off. Mute Button Mutes audible alarms except power fail. Constant Lower Pressure (CLP) Mode Offers excellent pressure redistribution. Pressure settings are directly proportional to those calculated for the Active Therapy mode. (Used when a moving surface is not recommended). Service Indicator Indicates that the pump is ready for a service or flashes when the pump has detected an internal fault. Power Fail Alarm Audible and visual indicator when a power failure has been detected. 6 7 8 9 10 Battery Low Indicator Illuminates 2 hours before battery failure and an audible alarm will sound 1 hour before battery failure. Low Pressure Alarm Illuminates whenever the pump detects low pressure within the mattress or seat cushion. An audible alarm will sound unless cancelled by the mute button. Wait Indicator Remains illuminated until the mattress/seat cushion has been fully inflated. Comfort Control User preference for softer or firmer surface enhances patient comfort and care without compromising performance. AutoFirm Provides a temporary stable support surface to assist patient transfer and other nursing procedures

Product specifications Product information Auto logic 110 Overlay Auto logic 200 Aura logic Seat cushion Matress Replacement Length 2030 mm (80 ) 2030 mm (80 ) 470 mm (18 ½ ) Width 860 mm (34 ) 860 mm (34 ) 455 mm (18 ) Height 115 mm (4 ½ ) 205 mm (8 ) 50 mm (2 ) Air filled sub mattress 2030 mm x 860 mm x 90 mm (80 x 34 x 3½ ) Cell material Polyurethane (PU) Polyurethane (PU) Polyurethane (PU) Base cover material PU coated nylon PU coated nylon Maximum patient weight 200 kg (441 lbs/31 ½ stone) 200 kg (441 lbs/31 ½ stone) 200 kg (441 lbs/31 ½ stone) Auto logic 175 Mattress Replacement Length 2030 mm (80 ) Width 860 mm (34 ) Height 175 mm (7 ) Foam Underlay Size Cell material Maximum patient weight 2032 mm x 838 mm x 63.5mm (80 x 33 x 2 ½ ) Polyurethane (PU) 200 kg (441 lbs/31 ½ stone) Pump Length 375 mm (14 ¾ ) Height 280 mm (11 ) Depth 125 mm (5 ) Weight Case Material Mode of Operation Supply Voltage/Frequency Electrical Rating 2.75 kg (6 lbs) ABS Plastic Continuous 100-240 VAC/50-60 Hz 85 VA MAX Operating Cycle Time Degree of protection against electric shock Degree of protection of ingress of liquids 1. NPUAP/EPUAP International Pressure Ulcer Guideline, 2009. 10 minutes Class II Double Insulated with Functional Earth Type BF (Mains Connected) Only ArjoHuntleigh designed parts, which are designed specifically for the purpose, should be used on the equipment and products supplied by ArjoHuntleigh. As our policy is one of continuous development we reserve the right to modify designs and specifications without prior notice. and are trademarks belonging to the ArjoHuntleigh group of companies. ArjoHuntleigh, 2010 IPX0 01.TS.07.4.GB-INT.1.AHG May 2013 www.arjohuntleigh.co.uk GETINGE GROUP is a leading global provider of products and systems that contribute to quality enhancement and cost efficiency within healthcare and life sciences. We operate under the three brands of ArjoHuntleigh, GETINGE and MAQUET. ArjoHuntleigh focuses on patient mobility and wound management solutions. GETINGE provides solutions for infection control within healthcare and contamination prevention within life sciences. MAQUET specializes in solutions, therapies and products for surgical interventions and intensive care. ArjoHuntleigh AB Box 61 SE-241 21 ESLÖV SWEDEN Phone: +46 413 645 00 Fax: +46 413 645 63 0086