BASnet LightiView Install Guide

Similar documents
FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Digi Connect ME 9210 Linux: 2 nd serial over FIM

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Certification Exhibit FCC ID: R7PIWRS4. FCC Rule Part: ACS Report Number: W03.11.A

Saline C 6.0 Junction Box

Digi Connect ME 9210 Linux: serial port 2 for JTAG modules

WELCOME TO THE FUTURE OF TELEVISION. User Manual

SPECIFICATIONS ATTENTION

OPERATING INSTRUCTIONS FOR MODEL VSBX

deluxe toilet safety support

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

SVEA II GSM Connector User Manual

PL475. Patient Lift Scale. Owner's Manual

Product Overview. Product Description CHAPTER

Drag racing system HL190 User Manual and installation guide

SAFETY & OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS FOR

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Quick Start Installation Guide

SDX Submersible Depth Transmitter User Manual

SDX Submersible Depth Transmitter User Manual

Electro-Pneumatic Converter YT-940 SERIES

All Purpose AP-Series Operation Manual

Smart JVA Module WARNING. For use with AquaLink RS systems with rev R firmware or newer.

Chapter 6. Gas Analyser Interface. Hanatech Co., Ltd.

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

Read This First. SurfLink Media Controls Overview. Back View

MODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual

Dual Solenoid Gas Valve Installation

ASSEMBLY INSTRUCTIONS

For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)

1. Set up your Stick Up Cam Wired.

COOPER POWER SERIES. VariSTAR Storm Trapper high energy MOV arrester installation instructions. Surge Arresters MN235017EN

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

OPERATOR S MANUAL SPREADER. CSS, VNQ [For Combine Harvester AW82V] Original instructions

COOPER POWER SERIES. 200 A 15, 25, and 35 KV class insulated standoff bushing installation instructions. Loadbreak Apparatus Connectors MN650039EN

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

INSTALLATION INSTRUCTIONS AND REFERENCE HANDBOOK

Tru Trak Sulky Proline Mid Size Mower Attachment

Baby Basketball. Model Number 74069

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

COOPER POWER SERIES. Series winding ratio test procedure instructions. Voltage Regulators MN225060EN. 120 Vac VOLTMETER

1. Set up your Stick Up Cam Wired.

AE R1 February 2015

User Manual. Quantos Automated Dosing Liquid Module

BGA158 Series CE Approved Class A Shutoff Gas Valve

NovelBright LED Illuminator

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

User Guide. 2 Player Basketball Game

OPERATING INSTRUCTIONS FOR

SERVICE & MAINTENANCE MANUAL FOR:

RaceAmerica Corporation 105 Bonaventura Drive San Jose, CA (408)

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 3K Puller (M3K-M)

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

DEEPSEA. Power & Light. Micro SeaLaser. Operator s Manual Ruffin Road San Diego, CA USA T: (858) F: (858)

Stick Up Cam Wired. 02_Stick_Up_Cam_Wired_MANUAL_ANZ.indd 1

BGA158 Series CE Approved Class B Shutoff Gas Valve

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Drag Racing Scoreboards

foldable/adjustable sawhorse

Ceiling Lift. Arm Extension OWNER S MANUAL

COOPER POWER SERIES. 200 A 15, 25, and 35 kv class portable feedthru installation instructions. Loadbreak Apparatus Connectors MN650037EN

INSTRUCTION MANUAL Pressure Relief Device LPT

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

DAI630TB2669 Dead Front Arrester Installation Instruction

COOPER POWER SERIES. 600 A 15, 25, and 35 kv class PUSH-OP bushing adapter cap installation instructions. Deadbreak Apparatus Connectors MN650050EN

User Manual. Bluetooth Pedometer. AmericanPumpkins. version:1.0

Cat #: 7310SB UPC #: Spec:

WELCOME TO THE REVOLUTION

Digital Melting Point Apparatus

Stick Up Cam Battery

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

OEM Manual. MODEL ½ Digit DRUM SCALE

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

RPS900W Redundant Power Supply. Installation Guide.

Aeroqual AirCal 1000 User Guide

Instruction Manual BA90 Precision Barometer

Resusci Anne Simulator

Electronic gas volume corrector model DGVC-04

Infrared Linescanners

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions

Aquatic Rescue Command Center

Procedure Troubleshooting the Interconnect Cables

Talas Measurer 250VDC Datasheet

SMART Oxygen Analyzer. User Manual

6 digital caliper with case

COOPER POWER SERIES. 600 A 15, 25 and 35 kv class bushing adapter installation instructions. Deadbreak Apparatus Connectors MN650058EN

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

MODELS (2 foot Version) (4 foot Version)

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

E Cube Lift Model: ECU Installation Instructions

215 Liquid Handler Up-Grade Manual

Transcription:

BASnet LightiView 1025 Cobb Place Blvd Suite 100 Kennesaw, GA 30144 800-241-9173 www.triateklighting.com

ATTENTION This section serves as a notice of the immediate or potential dangers involved when working with the equipment described throughout this manual. Any person involved in installation, maintenance, or service of the equipment should first carefully examine the equipment and read the instructions contained in this manual to ensure that personal and/or equipment injury is avoided. The following safety messages are used throughout this manual to alert of immediate or potential danger to life or property: Hint Indicates a tip or trick to help you with setting up or controlling the BASnet LightView. DANGER Indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, can result in death or serious injury. CAUTION: Indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury. CAUTION: Used without the safety alert symbol, indicates a potentially hazardous situation which, if not avoided, can result in personal or property damage. Failure to comply with proper handling of the TRIATEK Lighting products may void your warranty In addition, this symbol may appear in the margin of specific portions of text as a safety reminder. Applicable instruction steps will be listed beneath the symbol. Disclaimer This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designated to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Instructions contained in this user s guide should be performed only by qualified persons in accordance with local and national codes. TRIATEK Lighting and its affiliates assume no responsibility for any consequences related to the improper use of this manual. Page 2

Step 1: Inspect Package Contents Package Contents / Compare with pictures below (1 each) (1) BASnet Module (2) AC adaptor with power jack (3) Power cord for adaptor (4) Ethernet crossover cable CAT5 (5) Nine pin serial cable (6) Installers Guide (7) Users Setup Guide (1) (2) (7) (3) (6) (4) (5) Page 3

Step 2: Mounting Lightview may be placed on a desk or mounted on a wall or in an enclosure. Desk Non-mar rubber feet are provided. Wall / Optional Enclosure Key-holes for wall anchors are provided on the back plane of the unit. Step 3: Wiring Connections must be made to power and the lighting panel network. An Ethernet connection to a PC or LAN hub may also be required. A serial port is also provided for initial password and IP confi guration. See publication: BASnet Lightview User s Guide Power To power the unit power is supplied to either the modular jack or terminal block (only one at a time can be wired for power). AC adaptor with power jack and power cord for adaptor are supplied for desk mounting. A 120 VAC 60 HZ power source is required for this adaptor. If panel mounting is required a 24V (15VA) transformer is required (not included). When power is supplied to unit the power LED will be illuminated. AC adaptor power jack Power LED 24 VAC 12 VA power terminal Page 4

Step 3: Wiring, Con t Lighting Panel Network RS-485 LightView connects on the RS-485 twisted pair network with the TRIATEK lighting panels. LightView does not need to be at the end of the network. However, do not star or T-tap anywhere on the network. Plus-to-plus and minus-to-minus polarity must be maintained. The COM 1 RX And TX LEDS will be illuminated when communicating over the RS 485 network. COM 1 RX and TX LEDS RS 485/COM 1 Terminal 10 Base-T Ethernet LightView s RJ-45 port connects to a PC s network interface card via a cross-over (null modem type) CAT5 cable (included). To connect to LAN hub, use CAT5 straight cable. Ethernet Connection Console An RS-232 serial port is provided for initial confi guration of LightView. The connection is 9- pin Female. Cable is included. RS-232 Serial Port Page 5