AUTOMATED INDUSTRIAL MACHINE, INC

Similar documents
AUTOMATED INDUSTRIAL MACHINE, INC TOGGLE-AIRE DIVISION

AUTOMATED INDUSTRIAL MACHINE, INC TOGGLE-AIRE

AUTOMATED INDUSTRIAL MACHINE, INC. JORACO TOGGLE-AIRE DIVISION

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Index Table. Model 794. Installation, Operating and Maintenance Instructions

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

WEATHERIZING INSTRUCTIONS

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

FLANGED TWO-PIECE BALL VALVES

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Interface Devices, Inc. Hydraulic Mini Mule

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

FLANGED TWO-PIECE BALL VALVES

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

RULES FOR SAFE FIRING:

GAS FRYER Instruction Manual Model #5099NS

Model No Product Name Handpiece Only Complete System

AutoDrill s OUTSTANDING FEATURES

FLANGED MULTI-PORT BALL VALVES

AIR INLINE METAL SHEAR

TOOL ARMS with AUTOMATIC DOWN FORCE for LEVER-PERMIT AIR DRIVERS OWNER S MANUAL. This manual contains;

CS150 CAP STAPLER OWNER S MANUAL

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY

Yoke Block Instruction Manual

SSS SWEEPERS MODELS MS-31 & MS-39

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

600 / 600FC OWNER'S MANUAL

8 TON AIR/MANUAL FLAT BOTTOM JACK

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

2K 600mL Dispense Guns with Built-In Retainers

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

Owner s Manual Air Bag Lift Tables


Yoke Block Instruction Manual

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

DelVal Flow Controls Private limited

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

Owner s Manual Air Bag Lift Tables

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS


3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

602 STRINGING MACHINE OWNER'S MANUAL

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

4-in-1 Professional Inflator Kit

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

ROPV R40 E Series User Manual

HP-104 & HP-106 Tapping Machine OPERATIONS MANUAL

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Tube Tugger. Operating and Maintenance Instructions. Semi-Continuous Tube Extractor.

PNEUMATIC FLOORING NAILER PNEUMATIC FLOORING STAPLER

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

RADROVER REAR RACK INSTALLATION MANUAL

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

GALISO SOAP OPTION FOR PCT-ADW-D

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Installation, Operation and Maintenance Manual for Back Pressure Regulator

RAM 4021 Operation Manual

Air Tractor Preventative Maintenance Manual And Troubleshooting

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Tube-Line Accelerator Spinner Kit

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

KJ4000 Operating Instructions & Parts Manual NSN

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

LJ1-25 LouieJRtm Tapping Machine

EKASAND 93 x 178 mm (3 2 /3 x 7 in.) Orbital Sander

LOCK UP VALVES YT-400/405/430/435 SERIES

TactAir PCP Fill Kit/Adapter. Operation Manual

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

Installation and Service Manual

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Pure Water Power Purification System 4-Stage RODI Operations Manual

Safety, Operating and Maintenance Manual. TRAIN Rat DS9-TRAIN

Adjustable. Unloader Valve. O&M Manual. Part #

CLARKES ERO FEEDER MANUAL

SAFETY MEASURES. These important guidelines should always be followed to work safely with the PRIMATECH pneumatic stapler model Q180:

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

INFUSION SYSTEM (110V) (220V) USER S MANUAL

ACCU-MIX 1200 / / 26270

1000-Lb. Rapid Lift Hydraulic Table

S&S. Installation Instructions: S&S Stealth Air Cleaner Kit for Harley-Davidison Models With Stock Cable Operated Delphi EFI

/ FLT-M Quick Clean Rotary Airlock Valve Operators Manual. Kice Industries, Inc. RAV-M RAV-M

DBML-60/80 Squeeze Tool

2 in. 18 Gauge Brad Nailer. User manual

OPERATION and MAINTENANCE Guide

Installation, Operation & Maintenance Manual

SSS SWEEPERS MODELS MS-21 & MS-29

COMPACT METAL bender 99826

Safety and operating instructions

Transcription:

The Pneumatic Toggle Press Innovators. Since 1947. AUTOMATED INDUSTRIAL MACHINE, INC TOGGLE-AIRE DIVISION 347 Farnum Pike Smithfield, RI, USA 02917 401-232-1710 www.joraco.com Installation, Operation and Maintenance Direct-Aire Series Bench Presses

IMPORTANT It is the responsibility of the employer/purchaser to provide his or her employees with proper point of operation guards, and to insure that this equipment is used in accordance with the manufacturer's recommendations as well as any OSHA, federal, or state regulations that are applicable to such equipment. Because it is impossible to anticipate the conditions under which our equipment will be operated, additional safety devices and methods may be required to insure operator safety. Besides conforming to all federal, state, and local codes, the buyer should consider the safety of the entire operation involving any press, and see that any additional guarding, training, and maintenance deemed necessary is developed and enforced to protect the well being of the operator. THINK SAFETY......WORK SAFELY COPYRIGH T 201 2 By AUTOMATED INDUSTRIAL MACHINE, INC.

Index Section I - Press Overview 1.1 - Description 1.2 - Features 1.3 - Options 1.4 - Cylinder Components 1.5 - Function Section II - Valving 2.1 - Pneumatic Circuit 2.2 - Valving Connections Section III - Installation 3.1 - Un-boxing 3.2 - Synchro-Sig Installation 3.3 - Mounting Press 3.4 - Connect Air Supply 3.5 - Turn On Air Supply 3.6 - Test the Installation Section IV - Set-Up and Operation Section V Troubleshooting Section VII - Engineering Data 7.1 Standard Specifications 7.2 Cylinder Mounting 7.3 Bolster Plate Mounting

SECTION 1: OVERVIEW 1.1 DESCRIPTION The DIRECT-AIRE pneumatic press series features a straight pneumatic cylinder for applications requiring full force over the entire stroke such as assembling bushings, posts, inserts, fasteners, and related products. Suitable for a wide range of manual and semiautomatic assembly operations, this press is offered with a standard 4.5 stroke, providing from 650 to 2,300 lbs. 1.2 FEATURES Features include the following: 4.5 Standard Stroke 6 Through Space for Flexible Working Area 8 Open Height 1.3 OPTIONS Options include the following: Filter, Regulator, Lubricator (FRL) Non-Rotating Ram Adjustable Ram Speed Control Adjustable Stroke PLC Ready Optical No-Touch Anti-Tie Down Actuation

1.4 Cylinder Components Model NO. Replacement Seal Kits DA-300 DA-300AHS DA-400 DA-400AHS DA-400T DA-400TAHS SK300 SK300AHS SK400 SK400AHS SK400T SK400TAHS

SECTION II: VALVING PNEUMATIC CIRCUIT: NON CSR

SECTION III: INSTALLATION 3.1 UNBOXING Section III: Installation 3.1 Un-boxing Carefully remove the press from the crate, taking note of separately packed items such as the "Quick Exhaust Unit"(Optional), FRL Unit (Optional) and "Synchro-Sig" Actuator. Synchro-Sig may come mounted on some models 3.2 Synchro-Sig Installation A. Locate the 1/4" yellow tubing found under the press platen. Connect the tubing to the appropriate fittings on the actuator. See markings on the tubing. DO NOT OVERTIGH EN normally, 1/2 turn past finger tight is sufficient for an airtight connection. (Figure 1.1) B. Using the 1/4-20 hex head bolts supplied, mount the "Synchro-Sig" to the press as shown. Be sure to mount the aluminum lever guard between the actuator and the press at the same time. (Figure 1.2) NOTE: To insure operator safety some applications may require that you locate the "Synchro-Sig" actuator further away from your tooling. - PICTURES ARE FOR REFERENCE ONLY- SOME SECTIONS OF THIS MANUAL MAY NOT APPLY TO YOUR PRESS UNIT.

3.3 Mounting Press A. Select a bench of suitable size and strength. SECTION III: INSTALLING B. Bolt the press to the bench using the holes located in the press frame below the platen area. Never operate the press unless it is securely mounted on a bench or stand. CAUTION: WHENEVER CONNECTING YOUR AIR SUPPLY TO THE PRESS BE CER-TAIN TO FOLLOW SAFE OPERATING PROCEDURES AND KEEP ALL PARTS OF YOUR BODY AWAY FROM THE MOVING PARTS OF THE PRESS! 3.4 Connect Air Supply A. The air supply must be clean and conditioned. Preferably, a Filter, Regulator, Lubricator Unit, (Joraco Part No. FRL- HP) should be located within 6 feet of the press. For optimum results all air lines, fittings, and hoses used to supply the press should be the equivalent of 1/2" minimum. B. The minimum air pressure for operation is 50 PSI; the maximum is 100 PSI. The optimum operating range is 60-100 PSI. If your application consistently required substantially more than 100 PSI it may indicate the need for a stronger. C. Connect air supply to the press at the inlet port. NOTE: If lower air pressure is required consult factory about EZ-Dial option. NOTE: A three way Shut Off Valve like the one supplied must always be used to insure complete bleeding of the press circuits when air supply is off.

SECTION III: INSTALLING 3.5 Turn On Air Supply A. Remove the yellow lock out device found on the On-Off Valve. To turn the air on simply move the gold colored sleeve downward until it stops. Slide the sleeve upward to the stop to shut the sup ply off. With the supply on, check for air leaks and be sure all connections you have made are secure and air tight. If air leaks from inside the "Synchro-Sig" actuator the connections are incorrect. Correctly reconnect the tubing, taking note of the tubing labels. CAUTION: ENSURE HANDS ARE CLEAR OF ANY TOOLING BEFORE TURNING OFF AIR SUPPLY. THE WEIGHT OF A HEAVY TOOL MAY CAUSE IT TO DROP UNEXPECTEDLY. IF HEAVY TOOLING IS BEING USED BE SURE TO PLACE A STOP UNDER TOOLING BEFORE TURNING OFF AIR SUPPLY. NOTE: When the press is not in use or being serviced or maintained, always SHUT OFF the air supply and replace the lockout device. Secure with a padlock, etc. to prevent unauthorized use of the press. CAUTION: BEFORE PROCEEDING, MAKE SURE THE TABLE AND WORK AREA IS CLEAR OF ALL TOOLS, FOREIGN OB-JECTS, AND BODY PARTS. 3.6 Test The Installation A. Test the "Synchro-Sig" Two Hand Actuator by simultaneously depressing the levers on the Model SS-PB or by simultaneously placing a finger in each sensing "button" on the Model SS-OT. The press should cycle once, return to the top of the stroke, and await another signal from the actuator. If the levers or "buttons" are continuously held down the press should remain in the down position until one or both levers or buttons are released.

SECTION IV: SET UP AND OPERATION 4.1 Mount Your Tooling NOTE: Prior to installing any tooling in the press, proper point of operation guarding, specifically designed for your tooling, must be built and mounted on or around your tooling. CAUTION: NEVER OPERATE, SERVICE OR ADJUST THIS MACHINE WITHOUT PROPER INSTRUCTION. NEVER SERVICE THIS MACHINE WITHOUT FIRST SHUTTING OFF AIR SUPPLY. NEVER OPERATE THIS MACHINE WITH SAFETY GUARDS REMOVED. A. Using the tapped holes in the press platen, mount the lower portion of your tooling to the press. The platen is machinable and can be drilled and tapped as necessary. The standard bore in the press ram is.8125" with a depth of 1.5". Precisely fit your shank to the bore of the ram and lock the shank in with the 5/16-18 hardened lock screw located on the face of the ram. The end of the ram should bear against the upper portion of your tooling. NOTE: If your tool incorporates guide pins etc.,be sure the tooling easily moves along the full length of travel with no binding or misalignment. Correct any problems found in the tool before placing tooling into production.

SECTION V: TROUBLESHOOTING 6.1 Ram Will Not Extend Cause Air is not on Insufficient air supply Defective valve Tooling is binding Solution Turn on air supply Increase air supply pressure Contact AIM Joraco to replace Inspect / repair tooling 6.2 Ram Will Not Retract (stuck in down position) Cause Insufficient air supply Defective valve Tooling is binding Solution Increase air supply pressure Contact AIM Joraco to replace Inspect / repair tooling 6.5 Press Not Generating Pressure Cause Solution Insufficient air supply Increase air supply pressure Cylinder low on oil Refer to section 5.1 Cylinder out of working range Adjust tooling Damaged / worn seals Send cylinder to AIM Joraco 6.6 Ram Does Not Fully Retract Cause Solution Insufficient air supply Increase air supply pressure Tooling is binding Inspect / repair tooling Air trapped in oil reservoir Refer to section 5.1

6.1 Standard Specifications SECTION VI: ENGINEERING DATA 6.2 Cycle Times Cycle times vary depending on the volume of air being delivered by the customer, the length of the stroke, and the weight of the tooling.

6.3 Bolster Plate Mounting C-Frame Hole Locations SECTION VI: ENGINEERING DATA H-Frame Hole Locations NOTE: CUSTOM MOUNTING HOLES AVAILABLE UPON REQUEST

Factory Support SECTION VI: ENGINEERING DATA Our staff is available to assist you with any quuestions you may have regarding your AIM Joraco press. Call: 1-888-889-4287 Email: sales@joraco.com WARRANTY AIM Joraco, Incorporated (hereafter referred to as the manufacturer) warrants that all TOGGLE- AIRE, DIRECT-AIRE, and HYDRO-AIRE products will be free from defects in material and workmanship for a period of 180 days (6 months) from the date of shipment to the original purchaser. Any claim made against this LIMITED WARRANTY must be made by contacting the customer service department of the manufacturer. At its option AIM Joraco, Inc. will repair or replace any product it deems defective under the terms of this warranty. If factory service is required, transportation costs to and from the factory are to be paid by the purchaser. This warranty does not apply to equipment which has been subject to abuse, misapplication, negligence, improper maintenance, alteration, or failure to follow AIM Joraco, Inc. instructions. AIM JORACO INCORPORATED'S SOLE OBLIGATION UNDER THIS WARRANTY IS STATED ABOVE. THIS WARRANTY IS IN LIEU OF ALL OTHERS, EXPRESSED OR IMPLIED AND UNDER NO CIRCUM-STANCES WILL AIM JORACO, INCORPORATED BE LIABLE FOR ANY CONSEQUENTIAL DAM-AGES RESULTING FROM THE USE OF TOGGLE-AIRE PRODUCTS. THINK SAFETY... WORK SAFELY...