CYTO. Safe Preparation and Administration of Cytostatics

Similar documents
Infusion. 1 evercare inline

New. The high security connection

Compatible Baxter IV Sets

C O L O G Y. New. g u O N. l o t a C a. The high security connection

DIAGNOSTIC CARDIOLOGY

Making Life Easier Easypump II

Bloodlines, Tubing Systems, Accessories

Chest Drainage Systems for Cardiac & Thoracic Surgery. Including portable suction with Digital Air Leak Monitoring

NEXUS TKO. Specialty Neonatal/Pediatric. Safety Infusion Sets. Blood Reflux Protection 24/7! Anti-Reflux Technology Provides

Haemodialysis. Bloodlines, Tubing Systems, Accessories Product Range. Product name / Headline Subline

Alfred ECMO Circuit Priming and Storage Guide

Volumat Agilia _Volumat_Presentation_customer.ppt

BODYGUARD 2CH TWIN CHANNEL INFUSION PUMP

DONOR TM Pre-Evacuated Post-Operative Autologous Blood Reinfusion System

RocaFlow. Irrigation and Warming System

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

Tourniquet Systems Pressure Infusion

V-Green Protect-A-Line A range of drug-compatible extension lines designed to enhance patient safety during IV therapy.

IVIG Educational Presentation

MEDAP-FLOWMETERS FOR OXYGEN AND COMPRESSED AIR

Huber needle EZ Huber JetCan. Quality and Experience

Digital Display large color coded LED display is easy to read precise measuring shows actual cuff pressure

Alaris Pump module FAQs

InFlow Modular perfusion bioreactor

Myfuser SILICONE ELASTOMERIC PUMP. basic information

BS ml Bottle Sampling Unit

Standard Flexel 3D bioprocessing bags for Palletank

MEDAP-MOBILE GAS SUPPLY

PRODUCT CATALOGUE OF

Valve with Integrated Pressure Regulator for medical OXYgen

Information for patients and nurses. Rocket Ambulatory Chest Drain

TUBINGS / CONNECTION PIECES

BIOCLOSURE SYSTEM ASSEMBLIES

CultiBag STR. Disposable CultiBags

OxygenatOrs QUaDrOx-i adult QUaDrOx-i small adult

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Instructions for use Compressed air injector with water trap

WORKHOLDING APPLICATION BOOKLET

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs.

Patients Guide for Self Administering Intravenous Antibiotics General points

QUADROX-i Neonatal & Pediatric Maximum safety for the smallest patients.

EASYPUMP II THE FLEXIBLE SOLUTION FOR SHORT AND LONG TERM INFUSION THERAPIES

Fluido AirGuard System

Corning HYPERStack Cell Culture Vessel Closed System

CAPITAL CONTROLS SERIES NXT3000

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Innovative cap to reduce the noise raised by bubbling activity drainage working (vent close)

TOURNIQUET SYSTEMS & PRESSURE INFUSION

Varithena Delivery System Instructions for Use INSTRUCTIONS FOR USE Please read the Product Monograph before using the product.

Transfusion equipment for medical use. Part 4: Transfusion sets for single use, gravity feed

Caregiver s Reference Guide

TOURNIQUET SYSTEMS & PRESSURE INFUSION

Varithena Delivery System Instructions for Use

Installation restrictions for length of sections should also be noted.

MoveRoll Conveyor Operating and Maintenance Manual

MIC *, MIC-KEY * GASTRIC-JEJUNAL (GJ) FEEDING TUBE PATIENT USE & CARE GUIDE

Troubleshooting Guide Aquarius

Fluido AirGuard System

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

leaders in enteral delivery

Blood Pressure Monitoring: Arterial Line

Keofitt Aseptic Sampling Bag (Pat. pend.) Item no , & User Manual

KEOFITT ASEPTIC SAMPLING BAG (PAT. PEND.) Item no , & User Manual

Heated Wire - Neonate Ø10mm Infant Ø12mm

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

User Manual MFCS TM -EZ

Transferpette -8/-12

INSTRUCTION MANUAL LOW PRESSURE CALIBRATION PUMP MODEL PGL

RESPIRATORY HEALTH PRODUCTS

Skills & Scenarios 81

Installing ASI Umbilical Delivery Systems

AQUADEX FLEXFLOW SYSTEM QUICK REFERENCE GUIDE

UNITS /2017-E ENDOFLATOR 50. The New High-Performance Insufflator with Integrated Heating Element from KARL STORZ

INTERVENTIONAL CARDIOLOGY

System Flow Chart. ventilation patient connection

1. Introduction Why use the Flow-Through Cell? Component Identification... 1

Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 1: Introduction to Aquarius

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

Pressure ranges and accuracy classes for outlet pressure and safety devices

VBM. Product Catalogue. Accessories for Anaesthesia & Intensive Care

Innovation at its best

Description Advanced Features Typical Applications

The next generation of Blood and Fluid Warming

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

The right atmosphere for health. A system for medical gas supply

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

INSTRUCTION MANUAL FOR POLYKEG DISPOSABLE KEG

NeoNatalie Resuscitator Oxygen kit

ECOBULK FOODCERT + ASEPTIC The highest packaging safety for your food products

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

THE UNIVENTOR 400 ANAESTHESIA UNIT

A complete family of Pediatric Perfusion Systems

CRRT with Prismaflex LEADS TO More Flexibility, Ease of Use and Safety

AR251/AR251-B. Venepuncture and Infusion Arm. Instruction Manual

Introduction. Medley TM Medication Safety System. Alaris Medical Systems

RESPIRATORY HEALTH PRODUCTS

Type C-CUT. Quickstart. English Deutsch Français

User s Guide. Vacuum Controller for liquid delivery systems

Constant and Particle Free Point-of-Use Water Pressure

PRODUCT NUMBER: Rd40 Aluminium Canister HgP3

Transcription:

CYTO Safe Preparation and Administration of Cytostatics

CYTO The CODAN Connect Z and Cyto-Ad Z systems have been specifically developed for reliable, safe preparation and administration of cytostatics. Connection of the injection port Connect Z Connect Z is used in the preparation of cytostatics with infusion bags in order to avoid the use of cannulae. At the same time, the preparation and transmission of the medications must be possible without leaks and contaminations. The CODAN Connect Z fulfils both demands. Liquid can be safely removed from the bag or added to it with a syringe and without a cannula via a Luer Lock connection with a special open/close mechanism. Automatic, simple, safe The specific Luer Lock connection of the injection port has been constructed in such a way that it is opened in both directions by the Luer cone of the syringe. Liquid can be removed, but also added. After the syringe has been removed, the connection is automatically and immediately closed. Connect Z is filled with the help of gravity. It is important that the bag is not pressed at this stage. The connection piece with the FlowStop protective cap is held at the same height as the injection port. As soon as the liquid reaches the FlowStop protective cap, the flow is automatically stopped. In this way, leaks are prevented and the risk of contamination minimized. After this, the hose clamp is closed tightly underneath the injection port, a Luer Lock syringe is connected on the side connection and filled with the required amount of carrier solution. By using the CODAN Chemoprotect Spike, the carrier solution is mixed with the medication and then put back into the infusion bag. To start with, two to three millilitres of air are added to the system after the medication. This ensures that the entire quantity of medication enters the bag. After the syringe has been removed, Connect Z is then ready to be connected to the Cyto-Ad Z. The Cyto-Ad Z is available with 1, 2 or 4 connections. This enables the combination of a variety of administrations of cytostatics to the patients.

The CODAN Chemoprotect Spike eliminates excess or underpressure in the medication bottles and effectively retains aerosols. The amount of medication required is taken off with 2-3 ml of air. After this, the medication is injected into the Connect Z together with the air. The clamp of the Connect Z system, which is arranged directly beneath the injection part, is still closed in this process. After this, the connection is closed again with the green stopper. The tubing of the Connect Z system is now primed with the basic solution, the medication is only in the bag and is secured there by the closed clamp. The Luer Lock negative connections have been provided with non-return valves for avoidance of leaks and retrograde infusions. CODAN Connect Z Clip The Connect Z Clip has been developed in order to ensure an absolutely safe connection between certain infusion bags and and the spike of the Connect Z system. The clip provides additional safety in the administration of cytostatics. The connection to the infusion bag is secured even in transport, unintentional manipulation of the system is also prevented. 1 2 3 Simple application: Connect and lock the Connect Z Clip. The Connect Z Clip ensures additional safety in the administration of cytostatics. Now, the secure connection to the Cyto-Ad Z can take place. Cyto-Ad Z Safety with a system The Cyto-Ad Z is the most important part of the closed CODAN system for safe and low-risk administration of cytostatics and other The drip chamber should always be filled with the basic solution up to 80%, in order to compensate for small quantities of air which can result from the connection of the Connect Z systems. The 15 µm liquid filter ensures particle-free infusion administration.

Cyto-Ad Z with 3 connected Connect Z systems medications. The Cyto-Ad Z has been equipped with a specific spike which contains a non-return valve in the venting part. In this way, the safe and secure application of the Cyto-Ad system with infusion bottles and bags is achieved. At the same time, the medication lines connected are protected against leaks and retrograde infusions. The large drip chamber with a 15 µm liquid filter absorbs residual quantities of air. The CODAN roller clamp controls the flow of the infusion to the patient. NO DEHP Tubings All CODAN Cyto Systems products were manufactured from DEHPfree PVC tubing (NO DEHP) for the administration of the various cytotoxic medication. The plasticizer used is TOTM. FlowStop protective cap The FlowStop protective cap on the connection piece guarantees priming of the Cyto-Ad Z systems free of leaks and contaminations. This "critical" procedure can thus be carried out particularly safely and simply. The vented spike of the Cyto-Ad Z system permits connection of the set to bottles and bags by the integrated non-return valve. As the drip chamber is filled upside down at an angle of 45, the upper system is optimally primed. When the drip chamber is 80% full, the roller clamp can be closed and the drip chamber returned to the normal position. After this, the remaining system is primed. The liquid throughflow is automatically stopped when the FlowStop protective cap has been reached. The Cyto-Ad Z has been fitted with a Luer-Lock connection with rotating collar for a safe connection to the catheter which is also gentle on the patients. The FlowStop protective cap developed by CODAN enables safe priming of the system without leaks. The hydrophobic filter allows the air to escape and retains the liquid. Priming the Cyto-Ad Z Administering the cytostatics The Connect Z systems are connected directly to the Cyto-Ad Z. In order to avoid incompatibilities, only one medication should be administered at a time. Between each administration of medications, the system must be rinsed with the basic solution. After the medications have been applied, the system is disposed of without the emptied Connect Z systems being removed.

Variations Dedicated pumps specific IVIP systems CODAN provides a variety of combinable systems, specifically put together and aligned to the application in question. These IVIP systems guarantee a safe and reliable administration of cytostatics at any time, even with specific pumps. In addition, individual configuration of the devices, e.g. by special conveying and retention segments, silicon segments and hoses, is possible. Cyto-Ad Z Inline The Cyto-Ad Z Inline with 1, 2 or 4 connections is used in infusion The CODAN IVIP systems, developed to administer cytostatics with specific pump systems. devices with specific pump segments. The benefits of the Luer-Lock connections with integrated non-return valves allow also for applications in which the medications are to be put through an infusion pump. The vented spike with non-return valve also permits use of bottles or bags. At the end of the set, there is an inline spike adapter for connection of a dedicated pump set, an I.V. Micro filter set or others. Cyto Systems Specialities Amongst the Cyto Systems products used for regular IV administration of cytotoxics, various other product specialities are available: Infusion set equipped with 0.20 micron filter designed for the administration of TAXOL Opaque administration sets used for light-sensitive cytotoxic medication Cyto Bolus Adapter Sets bi- and trifurcated sets for bolus application of cytotoxics 4-Valve Multiflow Set manifold system for the intrathecal administration of cytotoxics Urology Adater Sets specific configuration for urological administration of cytotoxics Das Cyto-Ad Z Inline ist für die pumpengesteuerte Verabreichung von Zytostatika konzipiert worden.

CODAN worldwide CODAN is internationally known as a manufacturer and supplier of disposable medical administration systems. The CODAN Companies worldwide employs more than 1,500 people. The name CODAN represents reliability, quality and precision supported by the knowledge and experience of more than 50 years of research and development. Our worldwide production facilities and sales organisations deliver first class service to all our customers in the healthcare sector. CODAN Companies CODAN Medizinische Geräte GmbH & Co KG BRD CODAN pvb Critical Care GmbH BRD CODAN pvb Medical GmbH BRD CODAN PORTUGAL SA Portugal CODAN 11 SA Portugal CODAN US Corporation California USA CODAN Inc. New York USA CODAN NORGE A/S Norge CODAN TRIPLUS AB Sverige CODAN Limited Great Britain CODAN FRANCE Sarl France CODAN Medical AG Schweiz CODAN ARGUS AG Schweiz CODAN BV Nederland CODAN s.r.l. Italia CODAN Medical GmbH Österreich CODAN Steritex ApS Danmark CODAN Medical ApS Danmark CODAN DEHA ApS Danmark The CODAN range of products Infusion Sets Transfusion Sets Extension Lines and Manifold Connectors I.V. Accessories I.V. Filters and Filter Systems I.V. Cannulae Paediatric Products Withdrawal, Preparation and Administration Sets CODAN CYTO Chemoprotect Products Syringes Invasive Bloodpressure Monitoring Systems I.V. Pumps Continence Care Products Other CODAN Sets Compliance of the established quality management systems with the provisions of EN ISO 13485 and the European Directive 93/42/EEC was certified by the competent Notified Bodies. Thus we are entitled to mark our products with: TÜV Product Service for CODAN Medizinische Geräte GmbH & Co KG D-23738 Lensahn Lloyd's Register Quality Assurance for CODAN Steritex ApS DK-3060 Espergærde Danish Medical Devices Certification for CODAN Medical ApS DK-4970 Rødby TÜV Product Service for CODAN pvb Critical Care GmbH D-85661 Forstinning CODAN Medizinische Geräte GmbH & Co KG Stig Husted-Andersen Straße 11 D-23738 Lensahn Tel. +49 (0) 43 63 51 11 Fax +49 (0) 43 63 51 12 14 www.codan.de The decisive connection 94.2601.05