Mass Flow Controller (MFC) for Gases

Similar documents
Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

Bypass Mass Flow Controller (MFC) for gases

Mass Flow Controller (MFC) for Gases

Mass Flow Meter (MFM) for Gases

Mass Flow Controller (MFC) for Gases

Mass Flow Meter (MFM) for gases

Mass Flow Controller (MFC) for gases. Inline MFC for nominal flow rates from 25 I N. /min to I N

Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for gases

2/2-Way Proportional Valve (motor-driven)

2/2-Way Solenoid Control Valve

2/2-way proportional valve

2/2-way proportional valve

2/2-Way Solenoid Control Valve

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Model 601CV. Mass Flow Controller. Product Features:

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

4/2 way Pneumatic Solenoid Valve

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Design Features. General Description

Thermal flow sensor TA Di with integrated transducer for measuring mass flow, standard flow rate and air / gas consumption

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

better measurement Simply a question of

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Precision Mass Flow Meters / Controllers for Liquids and Gases

Отсечные клапаны с электроприводом Burkert

Digital Mass Flow Meters and Controllers for Gases

C-Flow Coriolis Mass Flow Meters

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Thermal flow sensor TA Di for separate evaluation units for measuring mass flow, standard flow rate and air or gas consumption.

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Proportional pressure regulators VPPE

Operating Instructions for Direct Flow Mass Flow Meter for gases. Model: DMW

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

PS100 Series. Pressure-Based PI Mass Flow Controller. Catalog

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

EPP4 Pressure Regulator Basic G 1/4"

Armatures for analytical probes

Thermal Energy Flowmeter Model KEC. Application Range. Special Features

Digital Flow Switch. Series PFM7

SPCH/ Blowing block

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Product Overview Mass Flow Controllers for Gases

MANUAL KPS Pressure Control Valve

Solenoid valves VZWF, force pilot operated

Expert Hydrostatic Level Transmitters

SonoMeter 30 Energy Meters

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S06*

Pressure Switch for gas and air GGAO-A4

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

Technical Data Sheet MF010-O-LC

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Features. Description

Pressure independent control valve (PICV) FLOWMATIC

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Measurement of Low GAS & Liquid Flows

Pressure Switch for gas and air

IN-FLOW CTA Industrial Mass Flow Meters and Controllers for Gases

MASFLO-OVAL Ⅱ THERMAL MASS FLOWMETER/CONTROL VALVE for GAS MEASUREMENT MODEL: FHC, FHD series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

BULLETIN E485A. Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design.

Operating Instructions DB41

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

Pneumatic spool valve islands

Quick Installation Guide Doc nr.: C Date:

High Performance Digital Gas Mass Flow Meters & Controllers

QBS Electronic Pressure Regulator

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

SmartTrak 100HP. Ultra-High Pressure Digital Gas Mass Flow Meters & Controllers. FEATURES DESCRIPTION

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Digital electro-pneumatic regulators Series ER100

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Gas Mass Flow Meter SUS/SUS316

Ratio Regulator Zero Governor. FRG/6 Series

Compact pressure switches for gas and air

KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h

[Instruments for vacuum measurement, checking and adjustment] 3

Mass Flow Controllers

Model PDT Dewpoint Transmitter

Programmable pressure and temperature transmitters PTM/RS485

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Pressure regulator for water

2/ Port G1/4

Transcription:

Mass Flow Controller (MFC) for Gases Type can be combined with... Direct flow measurement with CMOSens - Technology for nominal flow rates from 20 ml N /min to 80 l N /min (N 2 ) High accuracy and reproducibility Fast settling time Optional fieldbus Type 1150 Multi-channel program controller Type 0330 3/2 or 2/2-way solenoid valve Type 6013 2/2-way solenoid valve Type 6606 2/2 or 3/2-way solenoid valve MFC Communications Software Type controls the mass flow of gases that is relevant for most applications in process technology. The measured value provided by the sensor (see the description on page 2) will be compared in the digital control electronics with the predefined set point according to the signal; if a control difference is present, the control value output to the proportional valve will be modified using a PI-control algorithm. Due to the fact that the sensor is directly in the bypass channel a very fast settling time of the MFC is reached. In this way, the mass flow can be maintained at a fixed value or a predefined profile can be followed, regardless of pressure variations or other changes in the system. Type can optionally be calibrated for two different gases, the user is able to switch between these two gases. As the control element, a proportional valve working at low friction guarantees a high sensitivity and a good control characteristics of the unit. Typical application areas are gas dosing or rather the production of gas mixtures in: Test benches, Bio reactors, Heat treatment, Material coating, Burner controls and Fuel cell technology Technical data Full scale ranges 1) (Q nom ) 20 ml N /min to 80 l N /min (N ), please see table on page 2 Operating Media Neutral, non-contaminated gases, others on request Max. operating pressure 10 bar (145 psi) (at inlet) depending on the orifi ce of the valve Calibration medium Operating gas or air with conversion factor Medium temperature -10 to +70 C Ambient temperature -10 to +50 C Accuracy ±0.8% o.r. ±0.3% FS (after 1 min. warm up time) Linearity ±0.1% FS Repeatability ±0.1% FS Control range 1:50, higher control range on request Settling time (t 95% ) < 300 ms Body material Aluminium or stainless steel Electr. housing material PC (Polycarbonate), optional metal Sealing material FKM, EPDM, others on request Port connections NPT 1/4, G 1/4, screw-in fi tting or fl ange, others on request Control valve valve orifi ces kvs-values Valve is closed when power is off 0.05 to 4.0 mm 0.00006 to 0.32 m 3 /h Electr. connection Sub-D plug, 15-pin M12 5-pin for fi eldbus Power supply 24V DC 1) at standard conditions 1.013 bar (a) and 0ºC Voltage tolerance ±10% Residual ripple < 2% Power consumption Max. 3.5-14 W (depending on proportional valve used) Set point Feed impedance Output signal Max. current (volt. output) Max. load (current output) Digital communication Protection class Dimensions [mm] (without fi tting) Total weight Mounting position Light emitting diode display (default, other allocations possible) Binary input (default, other allocations programmable) Binary output (default, other allocations programmable) 0-5 V, 0-10 V, 0-20 ma or 4-20 ma > 20 kω (voltage), < 300 Ω (current) 0-5 V, 0-10 V, 0-20 ma or 4-20 ma 10 ma 600 Ω PROFIBUS-DP, DeviceNet, CANopen, RS232 or RS485 (RS interface only with Adapter) IP40 See drawings ca. 500 g (aluminium body) Horizontal or vertical Indication for Power, Limit (with analog signals) / Communication (with fi eldbus), Error Two 1. start autotune 2. not assigned One relay-output 1. Limit (setpoint not reached) Load capacity: 25V, 1A, 25VA www.burkert.com p. 1/6

Measurement principle The actual flow rate is detected by a sensor. This operates according to a thermal principle which has the advantage of delivering the mass flow without any corrections for the required pressure or temperature. A small part of the total gas stream is diverted into a small, specifically designed bypass channel, that ensures laminar flow conditions. The sensor element is a chip immersed into the wall of this channel. The chip, produced in CMOS technology, contains a heating resistor and two temperature sensors (thermopiles) which are arranged symmetrically upstream and downstream of the heater. The differential voltage of the thermopiles is a measure of the mass flow rate passing this bypass channel. The calibration procedure effectuates a unique assignment of the sensor signal to the total flow rate passing the device. Gas Min. Q Nom [Nl/min] Acetylene 0.02 40 Argon 0.05 80 Helium 0.2 500 Carbon dioxide 0.06 40 Air 0.02 80 Methane 0.03 80 Propane 0.01 20 Oxygen 0.02 80 Nitrogen 0.02 80 Hydrogen 0.2 500 Max. Q Nom [Nl/min] Notes regarding the selection of the unit For the proper choice of the actuator orifice within the MFC, not only the required maximum flow rate Q nom, but also the pressure values directly before and after the MFC (p 1, p 2 ) at this flow rate Q nom should be known. In general, these pressures are not the same as the overall inlet and outlet pressures of the whole plant, because usually there are additional flow resistors (tubing, additional shut-off valves, nozzles etc.) present both before and after the controller. Please use the request for quotation form on p. 4 to indicate the pressures directly before and after the MFC. If these should be unknown or not accessible to a measurement, estimates are to be made by taking into account the approximate pressure drops over the flow resistors before and after the MFC, respectively, at a flow rate of Q nom. In addition, please quote the maximum inlet pressure p 1max to be encountered. This data is needed to make sure the actuator is able to provide a close-tight function within all the specified modes of operation. The request form on page 5 contains the relevant fluid specification. Using the experience of Bürkert engineers already in the design phase provide us with a copy of the request containing the necessary data together with your inquiry or order. Ordering table for accessories (connectors are not included in the delivery) Article Item no. 15-pin electrical connection Sub-D socket 15-pin solder connection 918 274 Sub-D hood for Sub-D socket, with screw locking 918 408 Sub-D socket 15-pin with 5m cable, ass. on one side 787 737 Sub-D socket 15-pin with 10m cable, ass. on one side 787 738 PROFIBUS DP M12 plug 918 198 M12 socket 918 447 PROFIBUS T-Connector 902 098 Adapter RS232 adapter 654 748 RS485 adapter 654 538 2m PC extension cable for RS232 9-pin socket/plug 917 039 USB adapter 670 639 MassFlowCommunicator Communication software Download at www.burkert.com p. 2/6

Pin Assignment Sub-D plug, 15-pin Pin Connection 1 relay, NC contact 2 relay, NO contact 3 relay - middle contact 4 GND 24V-supply and binary inputs 5 supply +24V 6 8V output (only internal company use) 7 set-value input GND 8 set-value input + 9 actual value output GND 10 actual value output + 11 DGND (for RS232) 12 binary input 1 13 binary input 2 14 RS232 RxD (without driver) 15 RS232 TxD (without driver) Fieldbus version PROFIBUS DP B-coded, M12 socket (DPV1 max. 12 MBaud) Pin Connection 1 VDD 2 RxD/ TxD N (A-circuit) 3 DGND 4 RxD/ TxD P (B-circuit) 5 not confi gured DeviceNet, CANopen plug M12 Pin Connection 1 Shield 2 not confi gured 3 DGND 4 CAN_H 5 CAN_L p. 3/6

Dimensions [mm] Standard version Size A G 1/4 NPT 1/4 p. 4/6

Dimensions [mm] Sub-base version Version with external valve Size A G1/4 NPT 1/4 p. 5/6

MFC/MFM applications - request for quotation Please fill out and send to your nearest Bürkert sales centre* together with your inquiry or order Company Contact person Note You can fill out the fields directly in the PDF file before printing out the form. Customer No. Address Postcode/Town Department Tel./Fax E-mail MFC-application MFM-application Quantity Required delivery date Medium data Type of gas (or gas proportion in mixtures) Density [kg/m 3 ] 1) Medium temperature [ºC or ºF] Moisture content [g/m 3 ] Abrasive components / solid particles Fluidic data no ºC ºF yes as follows Maximum flow Q nom Minimum flow Q min l N /min 1) cm N3 /min 1) m N3 /h 1) cm S3 /min (sccm) 2) kg/h l S /min (slpm) 2) l N /min 1) cm N3 /min 1) m N3 /h 1) cm S3 /min (sccm) 2) Inlet pressure at Q nom p 1 = Outlet pressure at Q nom p 2 = Max. inlet pressure p 1max Pipe run (external-ø) MFC/MFM-port connection Installation Ambient temperature kg/h l S /min (slpm) 2) barg barg barg metric, mm imperial, inch without screw-in fitting 1/4 without screw-in fitting (DIN ISO 228/1) 1/4 NPT-thread (ANSI B1.2) with screw-in fitting sub-base version horizontal, valve upright (Standard) horizontal, valve reclined vertical, flow from above vertical, flow from below ºC Material data Body material Seal material Electrical data Output/input signal with standard signal with fieldbus output input 0-5 V 0-5 V PROFIBUS-DP 0-10 V 0-10 V DeviceNet 0-20 ma 0-20 ma CANopen 4-20 ma 4-20 ma Please quote all pressure values as overpressures with respect to atmospheric pressure [barg] 1) at: 1.013 bar(a) and 0ºC 2) at: 1.013 bar(a) and 20ºC To find your nearest Bürkert facility, click on the orange box Aluminium Stainless steel FKM EPDM other: www.burkert.com In case of special application conditions, please consult for advice. Subject to alterations Christian Bürkert GmbH & Co. KG 0905/5_EU-en_00891904 p. 6/6