Crystal Breath. High Level Design. Nicholas Castro, Suong Do, Joe Duffy, Joe Lervi, John Mullaney

Similar documents
How Ventilators Work. Chapter 3

Confidence comes with knowing you are Code-Ready.

siot-shoe: A Smart IoT-shoe for Gait Assistance (Miami University)

Canine Palpation Trainer with Embedded Sensors

Diver-NETZ Wireless Groundwater Monitoring Networks

IDeA Competition Report. Electronic Swimming Coach (ESC) for. Athletes who are Visually Impaired

Test Plans & Test Results

How to specify a product. Process Sensors and Mechanical Instruments

Project Title: Pneumatic Exercise Machine

Pressure Sensor Bridge Configurations

a wireless landscape

Circuit breaker diagnostic testing. Megger is a registered trademark

GOLFER. The Golf Putting Robot

SURFLINK ACCESSORIES. Life without limitations HEAR BETTER STREAM BETTER

Improving distillation tower operation

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

Judo Sensor Vest. Project Proposal. Team: Max Baumgartner (mtbaumg2) Alex Gaynor (bchmnng2) Janak Mehta (jrmehta3) TA: Samuel Sagan

Final Report. Remote Fencing Scoreboard Gator FenceBox

Medical Instruments in the Developing World

ETT Olfactometer: Getting started guide 2013a. ETT Olfactometer quick start

Digital Tourniquets. Product Details. For electricity VAC, 50/60 Hz

Advanced Test Equipment Rentals ATEC (2832) OMS 600

Tourniquet Systems Pressure Infusion

10 Best Practices for Electrosurgical Unit Testing

3M Electrial Markets Division EMS. Electronic Marker System

User s Manual. Copyright 2014 Trick Technologies Oy

Team Members: Research Subteam Passive Device Subteam Active Device Subteam. Axita Patel Garrett Ezell Abin Koshy

Gravity Fed System. Team Members: Chris Kulbago, Lauren Pahls, Ted Rakiewicz, Patrick O Connell, Sarah Salmon, James Brinkerhoff Group Number: 13631

RM-80 respiration monitor

The Criticality of Cooling

The Caddiellac. In the pursuit of perfection on the course, your clubs should follow your lead EE High Level Design

HZ-300 HAZER MACHINE USER MANUAL. Congratulations on the purchase of your new ANTARI HZ-300 Haze Machine.

Oxygen Concentrator Instruction

HumiSys HF High Flow RH Generator

Technical Data Sheet MF010-O-LC

City of Minot Specifications SCBA

Electronic Automatic Transmission for Bicycle

Application Note AN-107

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

The NXT Generation. A complete learning solution

1001ICT Introduction To Programming Lecture Notes

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

Simplified Automated Ventilator Training Slides

Wireless Groundwater & Surface Water Data Transmission Maximize data quality Reduce operating costs Near real-time insight

A4s Operation Manual

SVEA II GSM Connector User Manual

Look at the simplified diagram of the laser and cross-section of part of a disc. to detector

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Enclosed: Proposal for Kayak Slalom Race Timing System

EASYTOUCH. Because automation makes it all so simple. pentairpool.com

EWC EARLY WARNING CONTROL OPERATIONAL PRESENTATION. Charles Dickens (757)

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

BAPI Pressure Line of Products - FAQs

Panther 5 Acute Care Ventilator

Respiration. Figure 22: Schematic representation of the respiratory system

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

First Class. Monitoring. solutions for. Range of monitors CO 2 O 2 SpO 2 ECG NIBP. More Choices to meet your needs

EVA Extravehicular Activity Systems

Design and development of microcontroller based human airway pressure measurement system with real time graphical display for anaesthesia ventilator

AMS 6916 Board mount pressure sensor with ratiometric analog output

Point level switches for safety systems

AED Plus. The Best Support For Rescuers

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

AMS 6915 Board mount pressure sensor with digital output (I²C)

Industrial Compressed Air. Ultrasonic Leak Detection Survey Guide

Differential Pressure Transmiter

Grand Slam Tennis Computer Game (Version ) Table of Contents

Improve Process Reliability

boso Germany Do you? Premium quality essgeräte für die Selbstmessung I use equipment of BOSCH + SOHN to measure blood pressure.

Introduction to Pressure Measurement

Long term stability tests of INO RPC prototypes

WBEA Standard Operating Procedure

Operating Manual for the Evance Iskra R9000 Wind Turbine

Hatch cover tightness testing

Micro Motion 3098 Gas Specific Gravity Meter

Programmable pressure and temperature transmitters PTM/RS485

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Leakage Current Testing Is it right for your application?

Electronic gas volume corrector model DGVC-04

Manual of SF6 Comprehensive Tester

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

Integral type Differential pressure flowmeter VNT Series

EasyTouch. Because automation makes it all so simple. Pool and Spa Control Systems. by Pentair Water Pool and Spa

Royce Interface Level Analyzer and Sensors

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Code Blue III Simulators. ALS and Emergency Care Simulators

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Dr. Andrew Rawicz February 16, 1999 School of Engineering Science Simon Fraser University Burnaby, BC V5A 1S6

BREATHE SAFELY: The Proper Use of Respiratory Protection

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

BUBBLER CONTROL SYSTEM

Zoll AED Pro with CPR Stat-Padz & audio recording

Supplementary Operator s Manual 42/24-14 EN Rev. 3

UNIVERSAL MASK TEST SYSTEM

Detecting sound wave of bubbles produced in a boiling liquid

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

Traveling Waves vs. Standing Waves

Transcription:

Crystal Breath Nicholas Castro, Suong Do, Joe Duffy, Joe Lervi, John Mullaney

Table of Contents 1 Introduction...3 2 Problem Statement and Proposed Solution...3 2.1 The Problem:... 3 2.2 Proposed Solution:... 3 3 System Requirements...4 4 System Block Diagram...5 4.1 Overall System:... 5 4.2 Subsystem and Interface Requirements:... 5 4.3 Future Enhancement Requirements... 5 5 Decisions...5 6 Open Questions...6 7 Major Component Costs...7 8 Conclusions...7 Crystal Breath 2 EE Senior Design

1 Introduction During a surgery, the only resource for surgeons and anesthesiologists to confirm that their patient is still breathing is to use a stethoscope. The stethoscope is pressed up against the patient s neck and the doctor listens for the sound of air moving in and out of the throat. The problem with this process is that it is not a continuous method of determining whether or not a patient is breathing. Even though heart rate monitor is used in operating room, it does not detect breathing. Thus, a patient could theoretically stop breathing for a period of time while the heart rate monitor still detects pulses. By the time the heart rate monitor signals that the patient s heart has stopped, it may be too late, whereas a continuous breath monitor could sense a problem much sooner. Our goal is to develop a device that continuously monitors a patient s breathing throughout surgery. 2 Problem Statement and Proposed Solution 2.1 The Problem: Monitoring the status of the patient during surgery is crucial. However, when a patient s breathing becomes shallow, it is harder to notice the rise and fall of the chest, and to hear inhalation and exhalation. To indicate that the patient is still breathing, surgeons often hold a stethoscope to the patient s neck and listen for the air rushing through the larynx. This common procedure is burdensome. First, this takes valuable time from the doctors; one of them must occasionally locate a good measurement spot and hold the stethoscope in place for a few good seconds. Second, the doctor may interfere with the many cords and instruments surrounding the patient when he/she tries to get near the patient to measure the breathing rate. Our better solution to this problem is to develop a device that can continuously measure the air level rushing through the patient s neck, process the sound and visually display the breathing level on a monitor. This way the information is readily available to all staff in the operating room. 2.2 Proposed Solution: We want to create a breath monitor that will measure the strength of the patient s breath by placing it on the patient s neck. The device will ideally record nothing but the patient s breathing sound, which is then processed and display visually via a monitor. With the amount of medical equipment already present in the operating room, the ideal breath monitor will be wireless. However, first and foremost, we want to focus on making the device workable. If we achieve that goal, we will then modify the device to become wireless. Also, the device can hopefully be placed on the patient s chest if he/she is having a neck surgery. The breath monitor will give the surgeon more time and space to perform surgery. Crystal Breath 3 EE Senior Design

3 System Requirements In order for our device to be an effective alternative to measuring breath with a stethoscope, a number of requirements must be fulfilled from both an engineering perspective and a medical perspective. The most important requirement that must be achieved is safety and reliability. The goal for this device is that it is used in operating rooms, so it must provide surgeons with reliable, consistent, and continuous performance throughout the duration of an operation. The device must be easily sterilized in preparation for surgery. It is also important that the device gives a warning (either in the form of lights flashing or an audio signal) when the device malfunctions so the doctor knows to revert back to using the stethoscope to measure breath. From an engineering perspective, the most important requirement that must be fulfilled is sounding an alarm when the device recognizes when the patient s breath has become dangerously shallow or the patient has stopped breathing entirely. This entails determining a threshold of safe breathing and programming the microcontroller to recognize when the patient s breathing has dropped below the threshold. The microphone part of the device should readily attach to and detach from the patient s neck in, similar to the way a bandage is applied to the skin. The microphone should also provide a sound proof seal around the application area such that the microphone is only picking up the sound of air moving in and out of the throat and not any of the surrounding sounds in the operating room. The sound that is picked up by the microphone must be processed and displayed using LEDs. As of now, the idea is to use our microcontroller as a sort of oscilloscope to output the sound picked up by the microphone to a series of LEDs which will light on the basis of frequency and intensity of the sound. This means that the microcontroller must be able to process the analog signal input from the microphone, compute a Fourier transform to identify the frequency of the sound peaks, and be able to turn on the correct number of LEDs. Because the device must work continuously and consistently throughout a surgery, we will most likely have to power it through a wall outlet or use batteries and connect the microphone directly to the microcontroller, rather than transmitting the signal wirelessly. Using a direct connection from microphone to microcontroller will ensure that the signal does not pick up any noise or interference during transmission. Crystal Breath 4 EE Senior Design

4 System Block Diagram 4.1 Overall System: 4.2 Subsystem and Interface Requirements: The sound capture subsystem is comprised of a microphone and adhesive. The adhesive must be comfortable for the patient, does not shift laterally; and it should be small enough so that surgeons can have plenty of room to perform the surgery. Ideally, the microphone will not pick up any noise or ambient sound. To insure no extra sound is picked up, we require a unidirectional microphone, which will come into contact with the patient s neck. In addition, we will insulate the back of the microphone with sound absorbent material such as studio foam or soft silicone pad. The microcontroller system is the most flexible of the subsystems. It must convert sound to an electrical signal, then, like an oscilloscope, represent the signal visually. One possible method is to take a Fourier Transform of the resultant electrical signal. The final, and simplest subsystem, is the screen. We simply need a screen to visually display the sound coming from the microcontroller, possibly via a VGA cable. 4.3 Future Enhancement Requirements Our group wants to create a working device, thus we simplify the interface. Ideally, the breath monitor would be wireless, but first we are going to build a wired prototype. If we succeed, we will attempt to make the breath monitor wireless. Doing so would require a wireless transmitter from the microphone and a wireless receiver on the microcontroller. 5 Decisions The entire system will be powered using a 9V battery and should be able to continuously run for 10 hours to accommodate long surgery procedures. To capture the breath, a unidirectional microphone will be secured to the neck of the patient. The strength of the microphone connection Crystal Breath 5 EE Senior Design

to the neck is very important. Primarily, the microphone needs to remain fastened throughout surgery. Also, a high quality connection will insulate the microphone from ambient noise. Thus, we will try using double-sided medical tape since it is widely used in the medical field. The microphone will send the signal to the circuit board. The circuit board will contain the power supply connection, a bandpass filter to isolate the breath signal, and a microcontroller with analog-to-digital conversion potential. The microcontroller will be similar to the PIC32 microcontroller used in the design assignments throughout the semester. The microphone will pick up some noise that interferes with the breath signal. A filter consisting of resistive and capacitive components will cut off the frequencies outside of the breath frequencies, leaving behind a signal that contains the breath. The microcontroller will take this filtered signal as an input and perform an analog-todigital conversion. This will allow the sound signal to be processed and eventually be displayed graphically. Fourier transform can be performed to analyze the signal with regards to its frequency components, so the exact frequency and amplitude of the breath can be identified. The system will communicate to the user the strength of the breath in two ways. The first way will be applying the filtered analog signal to a group of red LEDs, which will light when a large enough signal is present. The brightness of the LEDs will correspond to the relative strength of the breath signal. A visual display will communicate more precisely to the user the strength of the breath signal by displaying the digital signal on a graphic display. The graphic display will receive its input from the microcontroller. Surgeons can make their own judgment whether or not the breathing level is dangerously low. The microcontroller will be programmed to signal a visual and audio warning if the patient s breathing level is dangerously low, or the batteries are running low on energy. 6 Open Questions One of the pressing questions we have going into the low-level design is whether or not we can connect a unidirectional microphone to the circuit and if the microphone works with a digital signal processing microcontroller. If not, then we have to consider other possibility and we then have to consider how to eliminate sounds that are picked up from other sources. If we have time to modify the device to work wirelessly, then a MEMS microphone is a possible option. We are also unsure how we would analyze the signal. We would like to display the signal on a monitor. However, we question if this requires the analog signal to be sampled and replicated in digital form in order to be displayed on a monitor, or if we should filter the signal and perform Fourier transform so that it may be displayed on an oscilloscope or monitor. In your feedback, it seemed that you wanted our group to pursue the former option, but is the latter option also a possibility for this project? Would our option still require an analog to digital conversion regardless of whether or not we filter and perform a transform on the signal? If we do pursue some of the ideas you recommended in your feedback, then we will have some extensive research, review, and testing to do in the way of signal analysis. With either option, we would all have to become even more thoroughly acquainted with the microcontroller, Crystal Breath 6 EE Senior Design

which each of us individually has a rudimentary understanding of at best. There are too many questions regarding the microcontroller to list in this section, but we will have to assess our knowledge and answer them soon. 7 Major Component Costs Major Component Cost Unidirectional Microphone $30 Studio Foam (insulator) $5 Medical Double Sided Tape $5 Microcontroller $30 Velleman Sound-to-Light Kit (for testing) $30 Cables $20 Battery $6 Total $126 8 Conclusions The development of an effective, and perhaps wireless, breath monitor will give surgeons more time focusing on saving lives in the operating room. Their time should not be wasted by activity such as checking the patient s breath. To accomplish this goal, our group will need to do extensive research in both the electrical engineering field as well as the medical field. From an engineering standpoint, we must develop a deep understanding of certain aspects such as what is the best breathing to background noise frequency, how to program an analog-to-digital converter, how to output a sound input visually, etc. From the medical perspective, we must make sure that the breath monitor is sterile and easily cleaned, does not interfere with other devices in the operating room, and works consistently throughout an operation. The breath monitor must also be easy to use, because the objective is to give doctors one less thing to worry about during a surgery. This means that microphone should attach to and detach from a patient s neck effortlessly. Thus, a simple, yet effective, user interface must be developed. Crystal Breath 7 EE Senior Design