GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

Similar documents
GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) B01

Pressure regulator FRS

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

GasMultiBloc Combined regulating and safety valve Infinitely variable air/gas ratio control mode MB-VEF B01

Old documentation - Only for your information! Product is not available anymore!

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

Pressure regulator FRS

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

Compact pressure switches for gas and air

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

SAV. Safety Shut-off Valve. Safety Shut-off Valve Type SAV

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

Gas Pressure Switch for DMV safety shutoff valves

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Line Pressure Regulators Class I or Class II. FRS 7../6 Series

Ratio Regulator Zero Governor. FRG/6 Series

Pressure Switch for gas and air GGAO-A4

Gas Pressure Switch for DMV safety shutoff valves

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S02

Tightness controls TC 1 3 and TC 4

Line Pressure Regulator. Class I or Class II. FRS 7../6 Series

Pressure switch for gas and air

Pressure Switch for gas and air

Tightness control TC. Product brochure GB 3 Edition AGA

Датчики-реле давления GW A5 DUNGS

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Old documentation - Only for your information! Product is not available anymore!

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

VRB00 Series CLASS B SERVO REGULATED COMBINATION VALVES

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

Safety. Operating instructions Magnetic relief valve VAN DANGER. Contents WARNING CAUTION. Changes to edition 11.11

Gas Pressure Switch for DMV safety shutoff valves

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA

SPECIFICATIONS ATTENTION

SPECIFICATIONS CAPACITY

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first O.K. IFGC CSA UL ANSI NFPA

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Gas Pressure Regulator HON 300

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

Gas Filters DN15 DN300. elektrogas.com EE151 06/13

Safety. Operating instructions Filter module VMF Measuring orifice VMO Fine-adjusting valve VMV DANGER. Contents WARNING CAUTION

Safety. Operating instructions Bypass/pilot gas valve VBY 8 DANGER. Contents WARNING CAUTION Elster GmbH Edition 01.15

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first IFGC CSA UL ANSI NFPA

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Dual Solenoid Gas Valve Installation

2/2-Way Solenoid Control Valve

GM-7000 Series CE Approved Gas Control Valve

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12

VMR VMR-OTN VMR 6 bar

SPECIFICATIONS ATTENTION

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

Butterfly Control Valve. DMK/6 Series

RB 4700 Commercial & Industrial Regulator

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Mass Flow Meter (MFM) for Gases

Solenoid valves VZWF, force pilot operated

GM-7000 Series CE Approved Gas Control Valve

Mass Flow Controller (MFC) for Gases

Type 4708 Supply Pressure Regulator

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

GM Series Dual-Block Multi-Function Gas Control Valves

Pressure Transmitters 36 F-27839

Commonwealth of Massachusetts Approved Product Approval code G

Gas Pressure Regulator R 51

Gas Pressure Regulator HON 200

Pressure Switch for gas and air

Transcription:

GasMultiBloc Combined regulator and safety shut-off valves MB-D(LE) 05 - B0 7. Edition 0.8 r. 76 5 Technical description The DUGS GasMultiBloc integrates filter, regulator, valves and pressure switches in one compact fitting. - Dirt trap: Fine mesh-sieve - One regulator and two valves: B0 - Two valves are fast opening - One valve is fast opening and one valve is slow opening - Solenoid valves up to 60 mbar (6 kpa) as per DI E 6 Class A Group - Sensitive setting of output pressure by proportional regulator as per DI E 88 Class A Group - High flow rates with low pressure drop - DC solenoid drive interference degree - Main volume restrictor at valve V - Hydraulic opening delay - Flange connections with pipe threads as per ISO 7/ - Simple mounting, compact, lightweight The modular system permits individual solutions by using external ignition gas tap in connection with separately controlled valves, by adding a valve proving system, mini/maxi pressure switches, pressure limiters, limit switch V. Application The modular system permits individual solutions in gas safety and regulator engineering. Suitable for gases of families,, and other neutral gaseous media. Approvals EC type testing certificate as per: EC-Gas Appliances Regulation EC-Pressure Equipment Directive Approvals in other important gas consuming countries.

Specifications ominal diameters Flange with pipe threads as per ISO 7/ (DI 999) Max. operating pressure MB- 05/07 B0 Rp /, / and their combinations 60 mbar (6 kpa) MB- 0/ B0 Rp /,, / and their combinations Output pressure ranges Media Ambient temperature Dirt trap Pressure switches Pressure regulator Solenoid valve V Solenoid valve V MB- S0/S p a : mbar (0. kpa) to 0 mbar ( kpa) MB- S50/S5 p a : mbar (0. kpa) to 50 mbar (5 kpa) Gases of families,, and other neutral gaseous media -5 C to +70 C (Do not operate MB-D below 0 C in liquid gas systems. Only suitable for gaseous liquid gas, liquid hydrocarbons destroy sealing materials.) Fine mesh-sieve, replacement only possible by dismounting the fitting. Types GW A5, GW A, B A, ÜB A mountable as per DI E. For further information, refer to Datasheet GW A o. 5 8 and Datasheet GW A5 o. 5 90. Pressure regulator compensated for residual pressure, leakproof seal when switched off by means of valve V as per DI E 88 Class A. Setpoint spring permanently installed (no spring exchange possible). A vent line above roof is not required. Internal pulse tap provided. Valve as per DI E 6 Class A Group, fast closing, fast opening Valve as per DI E 6 Class A Group Valve V design Main volume restrictor MB fast closing fast opening without MB-D fast closing fast opening with MB-DLE fast closing slow opening with MB-LE fast closing slow opening without Measuring/ignition gas connection Burner pressure monitor p Br Voltage / frequency Electrical connection Rating/power consumption Switch-on duration Degree of protection Radio interference For G /8 as per DI ISO 8, refer to Pressure taps on page Connection downstream of valve V, pressure switch A mountable on adapter laterally 50-60 Hz 0-0 V AC - 5% + 0% Other preferred voltages: 0 VAC, 0-0 VAC, 8 VDC, -8 VDC Plug connection as per DI E 750-80 for valves and pressure switches Refer on page 00% IP 5 as per IEC 59 (E 6059) Interference degree Materials of gas-conveying parts Housing Diaphragms, seals Solenoid drive aluminium die casting BR basis, Silopren (silicone rubber) steel, brass, aluminium Installation position Closed position signal contact Solenoid vertically upright or lying horizontally as well as its intermediate positions Closed position signal contact, type K0/ (DI-tested), mountable on V 5

Equipment variants GasMultiBloc...B0 MB MB-D MB-DLE MB-LE Microfilter with sieve Gas pressure switch downstream of filter downstream of valve V on adapter laterally downstream of valve V on flange with adapter Pressure regulator Valve V, double seat Valve V, single seat Valve V, double seat Valves controlled together Valves controlled separately Flange Rp / Rp / Rp Rp / 05 B0 07 B0 0 B0 B0 S 0, S 50 S, S 5 = possible () = on request - = not possible MB-...B0 version V = Valve V = Valve = Dirt trap = Pressure switch 5 = Regulator V 5 V Mounting of VPS 50 valve proving system possible Mounting of K0/ closed position signal contact possible Type key of MultiBloc 0 = common = separated = - 0 mbar up to 60 mbar 5 = - 50 mbar up to 60 mbar = two A valves for main gas + regulator 7 = two A valves for main gas, one A valve together with V as internal bypass around V + regulator 0 = D 0, V = Single-seat valve 05 = D 5, V = Single-seat valve 07 = D 0, V = Double-seat valve 0 = D 5, V = Single-seat valve = D, V = Double-seat valve 5 = D 0, V = Double-seat valve 0 = D 50, V = Double-seat valve without = (MB or MB-ZR) -D = Main volume restrictor -LE = adjustable opening behaviour -DLE = D + LE combination without = single stage ZR = double-stage with partial volume setting first stage 5

Dimensions [mm] e f h d c = Space requirement for cover of pressure switch f = Space requirement for exchanging the solenoid g c a b Typ Rp Opening time a b c Dimensions [mm] d e f g h Weight [kg] MB-D 05 B /07 B MB-DLE 05 B /07 B MB-D 0 B / B MB-DLE 0 B / B Rp / Rp / Rp Rp / < s < 0 s < s < 0 s 0 0 0 0 5 5 0 0 0 0 6 6 00 0 5 60 5 5 7 7 90 90 5 5 5 5,5,6,9 5,0 Electrical connection Rating / power consumption [VA] ~(AC) 0 V; +0 C: MP MB 05/07 S 0 MB 05/07 S 50 MB 05/07 S MB 05/07 S 5 6 6 6 MP P L S 0/S 50 MB 0/ S 0 MB 0/ S 50 MB 0/ S MB 0/ S 5 96 96 P L S /S 5 Pressure taps p e p a 56 5 5 p e pa,,,5 G /8 screw plug Test nipple 5

GasMultiBloc Combined regulator and safety shut-off valves MB-D(LE) 05 - B0 Volumetric flow pressure loss characteristics in regulated state with fine mesh-sieve p [mbar] MB-05 S0, S MB-05 S50, S5 MB-07 S0, S MB-0 S0, S MB-07 S50, S5 MB-0 S50, S5 MB- S0, S MB- S50, S5 60 00 p = mbar Br 00 50 00 80 60 50 0 Recommended operating range 0 0 0 8 6 5 V min. MB-D(LE) 05 Rp / - Rp / V min. MB-D(LE) 07 Rp / - Rp / V min. MB-D(LE) 0 Rp - Rp V min. MB-D(LE) Rp 5/ - Rp 5/ MB-D(LE) 05 Rp / - Rp / MB-D(LE) 07 Rp / - Rp / MB-D(LE) 0 Rp - Rp MB-D(LE) Rp 5/ - Rp 5/ 0, 0, 0, 0, 0,50,6 0,8 5 6 7 8 90 0 0 0 60 80 00 00 Vn [m /h] Luft / Air / Aria dv =,00 0, 0, 0, 0,50,6 0,8 5 6 7 890 0 0 0 60 80 00 00 Vn [m /h] Erdgas/atural gas/gaz aturel/gas metano dv = 0,65 f = Dichte Luft Spec. weight air poids spécifique de l'air peso specifico aria Dichte des verwendeten Gases Spec. weight of gas used poids spécifique du gaz utilisé peso specifico del gas utilizzato Gas type at. gas City gas LPG Air Spec. Wgt. [kg/m ] 0.8 0.58.08. dv 0.65 0.7.67.00 f..6 0.77.00 V verwendetes Gas/gas used/ gaz utilisé/gas utilizzato = V Luft/air/air/aria x f We reserve the right to make any changes in the interest of technical progress. 5 5 Head Offices and Factory Karl Dungs GmbH & Co. KG Karl-Dungs-Platz D-7660 Urbach, Germany Telephone +9 (0)78-80-0 Fax +9 (0)78-80-66 Postal address Karl Dungs GmbH & Co. KG Postfach 9 D-760 Schorndorf, Germany e-mail info@dungs.com Internet www.dungs.com