Series CL. Contactors. Intro J/X. Three and four pole contactors 9 to 105A (AC3) 25 to 140A (AC1) Standard voltages. Standards. Approvals A.52.

Similar documents
References 6 k thermal overload relays, adjustable from 0.11 to 16 A

Miniature controls. Contactors. Overload relays. Starters. Control relays

EU Declaration of Conformity

Meta-MEC Manual Motor Starters

Control and Automation

KAL36150 Molded Case Circuit Breaker, 600VAC, 150A

Retrofitting kit New Emax Direct Replacement of Megamax and Novomax

Differential pressure controls, Type MP 54, 55 and 55A

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

TeSys protection components

Lighting Contactors. 4.1 UL Rated AC Contactors

Differential Pressure Control Types MP 54, MP 55 and MP 55A

XML Electromechanical Pressure Switches

Differential pressure switch MP 54, MP 55 and MP 55A

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

CMC Series Moulded Case Circuit Breaker Cielo Electric

Position switches FP series

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

MaxSB - Low Voltage Switchboard

Electrical operating instructions

Pressure controls for hydro carbons, zone II applications, Type KPE

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et

Pressure switches for air and water CS

Model range*1) Switching pressure difference

Pneumatic spool valve islands

AE R1 February 2015

Automatic Valve Proving Control

Circuit breakers PR 60

Pressure switch KP-E. Data sheet

Electrical operating instructions

Differential pressure switch / Lube oil protection control MP 54 and MP 55

OTL Universal terminals

SPECIFICATIONS ATTENTION

F series Foot Switches

Radial Leaded > RGEF Series. Description. Features. Applications

POWR-BLOKS Distribution/Splicer Blocks and Covers

CALEFFI. Ball zone valves. series /03 GB

Revised on : 05. Jun TECHNICAL GUIDE PARTS CATALOGUE. Cal.VD51C ANALOGUE QUARTZ. SII Products

NEW. Mallia TM modular. These products are part of Power Line Carrier technology system > See p

Meta-MEC Manual Motor Starters

Project: Consultant : MEP Contractor: PREPARED BY: DORMAN SMITH SWITCHGEAR - DUBAI REVIEWED BY CONSULTANT : Page 1 of 15

MP15 Jockey Pump Controller

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

B2KL: 6-way ball valve with male thread, PN 16

Installation Instructions

OC Panel High Limit Aquastat Kit, Manual Reset p/n

RP series Rotor Pumps

SEAL Enclosure Installation Instructions

Installation Instructions

Budget Range Operators Handbook

Prewired position switches FA series

PRICE LIST Effective From January LV SWITCHGEAR. Be Switch. The Real Switchgear 230 V. SwitchTM INDUSTRIAL PIONEER VALUE CREATOR

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

MODELS YCAL0287, 0317, 0347 and YCAL0377 STYLE "C"

CONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17

Pressure controls, differential pressure controls type RT

Hand lever valves VHER

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

Safety Edges Safedge Profiles Specifications

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Pressure transmitters EMP 2

GEN20AD-GEN20AL-GEN18AN

2017 List Price. Exchange Part# CALL FOR PRICING

PROVENGAS AUTOMATIC PROVING SYSTEMS FOR GAS INSTALLATION

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

DPS-400 SERIES DPH-100 SERIES

Pressure switch Type BCP

enclosed product catalogue 2010 isolating switches main/emergency off switches changeover switches insulated stainless steel mild steel

Pushbuttons, Indicating Light, and Rotary Switch Stations Series 4975

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11

Erik Backström, High Voltage breakers, After Sales & Service High voltage SF 6 live tank circuit breakers After Sales & Service Training course

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

Accessories. Valves. Adjustable Pressure Relief Valves

Pressure Measurement Single-range transmitters for general applications

2018 List Price. Exchange Part# CALL FOR PRICING

MODELS YLAA YLAA0175 DESIGN SERIES A, B & C DEVELOPMENT LEVEL A

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

LENNOX SLP98UHV DIAGNOSTIC CODES

Pneumatic valve islands

Protection of motor circuits

TECHNICAL DESCRIPTION

INSTALLATION,OPERATION AND MAINTENANCE INSTRUCTIONS DRY AIR COOLER

Application of CHE100 in Frequency Conversion Alteration of Air Compressor System

Exchange Part# 2018 List Price CALL FOR PRICING CALL FOR PRICING CALL FOR PRICING

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

2-Phase Filters(Direct IEC Connector) RoHS. 250V AC 50/60Hz 1,2,3,6,10A KC, UL, CSA, VDE+ENEC, TÜV, CQC, 25 / 85 / 21

ACCESSORIES. Standard packing

4/2 way Pneumatic Solenoid Valve

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Inverse Proportional Pressure-Relief Cartridge, Size 10

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Operating instructions Capacitive sensor KIA (M30) / / 2010

Aquavar SOLO 2 Frequently Asked Questions

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Current transformers Measurement devices from 5 to 5000 A

It is essential that the maintenance staff is qualified for electrical works and follows safety procedures.

VERTICAL AIR COMPRESSORS

Transcription:

Three and four pole contactors 9 to 105 (3) 25 to 140 (1) ontrol circuit: lternating up to 690V irect up to 440V Terminal numbering in accordance with N 50005 and N 50012 ixing by clipping onto 35mm N rail N 5002235 or by screws Screws protected against accidental contact in accordance with V 0106 T.100, V4. Ring terminal version Three coil terminals Mounting possibilities of front/side instantaneous auxiliary contact blocks, timed auxiliary contact blocks, mechanical latch, transient suppressor block and interface modules. egree of protection: P20 to L00... L02 P10 to L25... L10 Maximum number of auxiliary contacts: 4 for L00... L25 6 for L04... L45 8 for L06... L10 Standards /N 609471 /N 6094741 /N 6094751 N 50005 UL 508 NM S 1 S 5424 & 775 pprovals culus Lloyd s Register MQ (up to th=32) ureau Veritas (ontact for details) uxiliary contact blocks ccessories Technical data Terminal numbering imensions S 22.2/14 N 63110 S 1025 V 0660/102 NL 419 RN pg..53 pg..57 pg..58 pg..91 pg..99 pg..112 Standard voltages To complete the catalogue number, replace the symbol by the code corresponding to the voltage and frequency of the control circuit. lternating (V). ualfrequency coil 1 2 9 3 4 5 6 7 13 8 15 24 42 48 110 120 220 230 240 400 440 480 50/60z 115 lternating (V). K L N T U W Y Z 32 127 220 380 415 500 660 50z 230 400 690 208 277 380 480 460 600 60z irect (V) or contactors type L... / Operating limits: 0.80... 1.10 x Us J K N P R T X Voltage 12 24 36 42 48 60 72 110 120 220 230 240 250 440 125 oil with electronic module for contactors L... (can also be used with alternating ) J N Y Voltage 24 42 60 110 220 440 28 48 72 125 250 irect (V). oil with wide voltage range (0.70... 1.30 x Us) or contactors type L... W W W W W W W WJ WK WN WP WR WT WX 12 24 33 42 48 60 72 110 125 220 230 240 250 440 oil with electronic module for contactors L... W W W W WJ WN Voltage 24 33 48 72 110 220 Maximun number of addon auxiliary contact blocks: L00...L02 : 2NO or 1N L03...L45 : 1NO and 1N L05...L10 : 4NO or 2N L05...L10 : 4 cont. aux. ifferent auxiliary contact configurations, contact us..52

Three pole contactors. Screw terminal load 1 Motors <440V, 3 ~ 50/60z 3 25 9 dmissible power 3 P P P P lectrical ux. endurance contacts at. 3 Operations 2.2 4 4 5.5 2x10 6 1 0 3 5.5 5.5 7.5 0 0 3 4 1 2 ontrol circuit: lternating at. no. (1) (3) ontrol circuit: irect ontrol circuit: oil with electronic module (/) L00310T 5 L00301T 5 at. no. (1) (3) L00310T 10 L00301T 10 at. no. (1) (3) 3 5.5 5.5 7.5 2x10 6 1 0 4 7.5 7.5 10 0 1 L01310T 5 L01301T 5 L01310T 10 L01301T 10 4 7.5 7.5 10 1.7x10 6 1 0 5.5 10 10 13.5 0 1 L02310T 5 L02301T 5 L02310T 10 L02301T 10 7.5 11 11 15 1.2x10 6 0 0 10 15 15 20 7.5 12 12 15 2x10 6 1 0 10 16 16 20 0 1 9 16 16 18.5 2x10 6 1 0 12 22 22 25 0 1 L25300T 5 L03310M 10 L03301M 10 L04310M 10 L04301M 10 L25300T 10 L03310M 10 L03301M 10 L04310M 10 L04301M 10 60 40 11 18.5 22 25 2x10 6 0 0 15 25 30 34 L45300M 10 L45300M 10 90 50 15 22 25 30 1.8x10 6 0 0 20 30 34 40 L06300M 1 L06300M 1 L06300M 1 18.5 30 37 40 1.7x10 6 0 0 25 40 50 55 L07300M 1 L07300M 1 L07300M 1 110 80 140 95 22 37 45 45 1.5x10 6 0 0 30 50 60 60 25 45 50 55 1.7x10 6 0 0 34 60 68 75 L08300M 1 L09300M 1 L08300M 1 L09300M 1 L08300M 1 L09300M 1 140 105 30 55 55 65 1.5x10 6 0 0 40 75 75 88 L10300M 1 L10300M 1 L10300M 1 Spare coils L00 L25 L03 L45 L06 L10 coil + electronic module L06 L10 L1 5 L3 5 L4 5 (1) To complete the catalogue number, replace the symbol by the code corresponding to the voltage and frequency of the control circuit (see.52). quipped with two blocks L (3) Multipack, see below Multipack. Series M and L1 5 L3 5 L4 1 L4 1 To reduce the amount of waste packaging material and to save time during installation, we offer the opportunity to order contactors in a multipack without the individual packaging. Product Type Standard pack Multipack (1) L00...L25... 20 40 L03...L45... 10 20 (1) The quantity ordered must be a multiple of the quantity in each multipack ( with the same frame/size and coil voltage) ow to order To order a multipack, add the suffix MP to the standard catalogue number or reference numbers, xample Standard pack Multipack L03400MJ L03400MJ MP (20 pieces).53

Three pole contactors. Ring terminal load 1 Motors <440V, 3 ~ 50/60z 3 25 9 dmissible power 3 P P P P lectrical ux. endurance contacts at. 3 Operations 2.2 4 4 5.5 2x10 6 1 0 3 5.5 5.5 7.5 0 1 3 4 1 2 ontrol circuit: lternating at. no. (1) L00310R 5 L00301R 5 ontrol circuit: irect at. no. (1) L00310R 10 L00301R 10 3 5.5 5.5 7.5 2x10 6 1 0 4 7.5 7.5 10 0 1 L01310R 5 L01301R 5 L01310R 10 L01301R 10 4 7.5 7.5 10 1.7x10 6 1 0 5.5 10 10 13.5 0 1 L02310R 5 L02301R 5 L02310R 10 L02301R 10 7.5 11 11 15 1.2x10 6 0 0 10 15 15 20 7.5 12 12 15 2x10 6 1 0 10 16 16 20 0 1 9 16 16 18.5 2x10 6 1 0 12 22 22 25 0 1 L25300R 5 L03310R 10 L03301R 10 L04310R 10 L04301R 10 L25300R 10 L03310R 10 L03301R 10 L04310R 10 L04301R 10 60 40 11 18.5 22 25 2x10 6 0 0 15 25 30 34 L45300R 10 L45300R 10 90 50 15 22 25 30 1.8x10 6 0 0 20 30 34 40 L06300R 1 L06300R 1 18.5 30 37 40 1.7x10 6 0 0 25 40 50 55 L07300R 1 L07300R 1 110 80 140 95 140 105 22 37 45 45 1.5x10 6 0 0 30 50 60 60 25 45 50 55 1.7x10 6 0 0 34 60 68 75 30 55 55 65 1.5x10 6 0 0 40 75 75 88 L08300R 1 L09300R 1 L10300R 1 L08300R 1 L09300R 1 L10300R 1 Spare coils L00 L25 L03 L45 L06 L10 L1 5 L3 5 L4 5 L1 5 L3 5 L4 1 (1) To complete the catalogue number, replace the symbol by the code corresponding to the voltage and frequency of the control circuit (see.52). Multipack, see.53 or reference numbers,.54

our pole contactors. Screw terminal loads 1 3 dmissible power 1 lectrical Power endurance contacts at. 1 Operations 9.5 16.5 18 21.5 1.5x10 6 4 0 ontrol circuit: lternating at. no. (1) L01400T 5 ontrol circuit: irect at. no. (1) L01400T 10 ontrol circuit: oil with electronic module (/) at. no. (1) 12 22 23 27.5 1.5x10 6 4 0 L02400T 5 L02400T 10 17 29 32 39 2x10 6 4 0 L03400M 10 L03400M 10 90 50 140 95 <440V, Motors loads 3~ 50/60z 3 1 22.5 39.5 43 52 1.5x10 6 4 0 34 59 64 78 1.5x10 6 4 0 42 72.5 79 95 1.8x10 6 4 0 53 92 100 121 1.8x10 6 4 0 dmissible power 3 P P P P Power contacts 3 5.5 5.5 7.5 2 2 4 7.5 7.5 10 L04400M 10 L05400M 1 L07400M 1 L09400M 1 ontrol circuit: lternating at. no. (1) L04400M 10 L05400M 1 L07400M 1 L09400M 1 ontrol circuit: irect at. no. (1) L05400M 1 L07400M 1 L09400M 1 ontrol circuit: oil with electronic module (/) at. no. (1) L0100T 5 L0100T 5 4 7.5 7.5 10 2 2 5.5 10 10 13.5 7.5 12 12 15 2 2 10 16 16 20 L0200T 5 L0300M 10 L0200T 5 L0300M 10 90 40 9 16 16 18.5 2 2 12 22 22 25 11 18.5 22 25 2 2 15 25 30 34 18.5 30 37 40 2 2 25 40 50 55 L0400M 10 L0500M 1 L0700M 1 L0400M 10 L0500M 1 L0700M 1 L0500M 1 L0700M 1 110 80 22 37 45 45 2 2 30 50 60 60 L0800M 1 L0800M 1 L0800M 1 Spare coils L00 L25 L03 L45 L05 L08 oil + lectronic module L05 L08 L1 5 L3 5 L4 5 L4 1 L1 5 L3 5 L4 1 L4 1 (1) To complete the catalogue number, replace the symbol by the code corresponding to the voltage and frequency of the control circuit (see.52). Multipack, see.53 or reference numbers,.55

our poles. Ring terminal load 1 3 dmissible power 1 lectrical Power endurance contacts at. 1 Operations 9.5 16.5 18 21.5 1.5x10 6 4 0 ontrol circuit: lternating at. no. (1) L01400R 5 ontrol circuit: irect at. no. (1) L01400R 10 12 22 23 27.5 1.5x10 6 4 0 L02400R 5 L02400R 10 17 29 32 39 2x10 6 4 0 L03400R 10 L03400R 10 22.5 39.5 43 52 1.5x10 6 4 0 L04400R 10 L04400R 10 90 50 34 59 64 78 1.5x10 6 4 0 L05400R 1 L05400R 1 42 72.5 79 95 1.8x10 6 4 0 L07400R 1 L07400R 1 140 95 load 1 Motors <440V, 3~ 50/60z 3 53 92 100 121 1.8x10 6 4 0 dmissible power 3 P P P P Power contacts 3 5.5 5.5 7.5 2 2 4 7,5 7,5 10 L09400R 1 ontrol circuit: lternating at. no. (1) L0100R 5 L09400R 1 ontrol circuit: irect at. no. (1) L0100R 5 4 7.5 7.5 10 2 2 5.5 10 10 13.5 7.5 12 12 15 2 2 10 16 16 20 L0200R 5 L0300R 10 L0200R 5 L0300R 10 9 16 16 18.5 2 2 12 22 22 25 L0400R 10 L0400R 10 Spare coils L00 L25 L03 L45 L05 L08 LR1 5 LR3 5 LR4 5 LR1 5 LR3 5 LR4 1 (1) To complete the catalogue number, replace the symbol by the code corresponding to the voltage and frequency of the control circuit (see.52). Multipack, see.53 or reference numbers,.56

uxiliary contact blocks nstantaneous Number ontacts Type Time of contacts 3 1 7 5 at. no. Ref. no. rontal mounting 4 2 8 6 Terminal: screw 1 1 0 0 0 L10 104700 10 1 0 1 0 0 L01 104701 10 1 0 0 1 0 L10 104702 10 1 0 0 0 1 L01 104703 10 Terminal: ring terminal 1 1 0 0 0 R10 108901 10 1 0 1 0 0 R01 108902 10 Side mounting Terminal: screw 2 2 0 0 0 LL20 104706 10 2 1 1 0 0 LL11 104707 10 or combinations of more than 4 frontmounted and 2 sidemounted auxiliary contact blocks 2 2 0 0 0 RLL20 104704 10 2 1 1 0 0 RLL11 104705 10 2 0 2 0 0 RLL02 106622 10 Pneumatic timer ront mounting Terminal: screw 2 0 0 1 1 elay ON 0.1 30 sec. TL30 104709 10 2 0 0 1 1 elay ON 1 60 sec. TL60 104710 10 2 0 0 1 1 elay O 0.1 30 sec. TL30 104711 10 2 0 0 1 1 elay O 1 60 sec. TL60 104712 10 Terminal: ring terminal 2 0 0 1 1 elay ON 0.1 30 sec. TR30 108903 10 2 0 0 1 1 elay ON 1 60 sec. TR60 108904 10 2 0 0 1 1 elay O 0.1 30 sec. TR30 108905 10 2 0 0 1 1 elay O 1 60 sec. TR60 108906 10 Seaking cover protection for pneumatic timer TLX 113001 5 ccessories Number ontacts or use of contacts 3 1 7 5 at. no. (1) Ref. no. nterlock 4 2 8 6 Mechanical L00... L10 L 104723 5 Mech./ electrical 2 0 2 L00... L10 L02 104724 5 Support interlock Only for direct contactors L00...L10 SL 101017 5 Mechanical latch blocks rontal mounted to the contactor L00... L10 RML see bottom 10 J N U Y 50z 24, 32 42, 48 110, 115, 120, 127 220, 230, 240 380, 400, 415, 440, 480 500, 660/690 60Z 24, 32 48, 60 110, 115, 120, 127 208, 220, 240, 277 380, 400, 415, 440, 480 600 24, 32, 36 42, 48 60, 72 110, 120, 125 220, 230, 240, 250 440 1) To complete the catalogue number, replace the symbol by the code corresponding to the voltage and frequency of the control circuit (see.52). or reference numbers,.57

Transient voltage suppressor block ccessories or use Type ontrol circuit Ue at. no. Ref. no. ixation to the coil terminals, that allows simultaneous use with the auxiliary contact blocks. L00... L45 R/ 12V... 48V SLR2 104713 10 L00... L45 R/ 50V... 127V SLR2K 104714 10 L00... L45 R/ 130V... 250V SLR2R 104715 10 L05... L10 R/ 12V... 48V SLR3 104716 10 L05... L10 R/ 50V... 127V SLR3K 104717 10 L05... L10 R/ 130V... 250V SLR3R 104718 10 L iode 12V... 600V SLZ 104719 10 L00... L10 Varistor / 24V... 48V SLV3 104720 10 L00... L10 Varistor / 50V... 127V SLV3K 104721 10 L00... L10 Varistor / 130V... 250V SLV3R 104722 10 L00... L10 Varistor / 277V... 500V SLV3U 110836 10 lectronic timer module or use ontrol circ. Type Time at. no. Ref. no. ixation to the coil terminals, that allows simultaneous use with the auxiliary contact blocks. L00... L10 24250V / delay ON 0.1 2 sec. TL02 113602 5 L00... L10 24250V / delay ON 1.5 45 sec. TL45 113603 5 L00... L10 24250V / delay O 0.1 2 sec. TL02 113604 5 L00... L10 24250V / delay O 1.5 45 sec. TL45 113605 5 dentification ccessories or use at. no. Ref. no. L00... L10 Sheets of labels (sheets of 260 labels each) T 260 100548 1 L00... L10 Labelling plate base (50 pieces in one pack) SPR 100549 1 Pole terminal protector PXX L03... L04 PTP04 113850 8 L45 PTP45 113851 6 L05... L08 PTP08 113852 8 L09... L10 PTP10 113853 8 ontact kits Spares or use Number of sets Type at. no. Ref. no. L03_3_/L03_4_ 3 NO V31203 104743 1 L03 4 2NO2N V1203 133170 1 L04_3_/L04_4_ 3 NO V31204 104745 1 L04 4 2NO2N V1204 133885 1 L45_3_ 3 NO V31245 104758 1 L05_4_ 4 NO V31205 104747 1 L05 4 2NO2N V1205 104748 1 L06 _ 3 NO V31206 104749 1 L07_3_/L07_4_ 3 NO V31207 104750 1 L07 4 2NO2N V1207 104751 1 L08_3_/L08_4_ 3 NO V31208 104752 1 L08 4 2NO2N V1208 104753 1 L09 _ 3 NO V31209 104754 1 L10 _ 3 NO V31210 104755 1.58

irectonline starters 9 to 105 (3) Power circuit: up to 690V ontrol circuit: up to 690V Protection degree P00 mpty boxes Neutral terminal irectonline starters or use with Pushbuttons Protection at. no. Ref. no degree L00, L01,L02 Start/Stop + Reset P40 L0004P10 209344 1 P65 L0006P10 200004 1 Without pushbuttons P40 L0004S10 209347 1 P65 L0006S10 116011 1 Only Reset P40 L0004R10 116651 1 P65 L0006R10 116652 1 L25 Start/Stop + Reset P40 L2504P10 100885 1 P65 L2506P10 101095 1 Only Reset P40 L2504R10 116226 1 P65 L2506R10 133611 1 L04 Start/Stop + Reset P40 L0404P10 116653 1 P65 L0406P10 116656 1 Only Reset P40 L0404R10 133264 1 P65 L0406R10 133265 1 L25, L04 Without pushbuttons P40 L0404S10 116996 1 P65 L0406S10 116997 1 NL 104797 10 onversion to permanent control Start contact block Pressurefixed between pushbuttons in directonline enclosures PL 104798 10 for mechanical interlocking into permanent control. Pressurefixed onto the front of directonline starters allowing electrical ML 104800 10 operation using the start pushbutton on the enclosure Wiring diagramspage.132 imensionspage.137.59

Reversing starters 9 to 40 (3) Power circuit: up to 690V ontrol circuit: up to 690V P00 version Polycarbonate enclosure (P40 P65) Shock resistance Total insulation 4 knockout input holes mpty enclosures version Start contact block Wiring kits for reversing starters Reversing starters escription Suitable to be usd with link modules Upper and lower connections without overload relays or use with contactor L00.., L01.., L02.. ac/dc ac/dc at. no. WKL02P Ref. no. 101422. 1 Plate Metallic plate L06, L07, L08 L08, L09, L10 WK0910 WK0608 241751 241752 1 1 Stardelta starters Power circuit: up to 690V ontrol circuit: up to 690V Protection degree P00 Use delay setting by electronic relay NMT Terminals protected against accidental contact usbar sets for power circuit Stardelta starters Linedelta at. no. Ref. no. contactor L00 WKL00 103238 1 L01, L02 WKL02 103241 1 Plate page.60 Wiring diagramspage.132 imensionspage.137 Metallic plate L06, L07, L08 WLS 103247 1 L09, L10 WLS1 241750 1.60