SKYBOX USER GUIDE EMERGENCY ULTRAFILTRATION PACKAGE. The trusted choice for rapid response potable water solu4ons SKYBOX

Similar documents
USER GUIDE EMERGENCY PUMP KIT ULTRAFILTRATION ULTRAFILTRATION SYSTEMS. safe drinking water ULTRAFILTRATION UNIT FOR USE WITH:

Advanced Fluid Handling Cart Owner s Manual

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps

DF-5 48 Inch Gas Train 10/09/2012

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

Operating Instructions Model and Hydrostatic Test Pump

TurboDraft. Fire Eductor Operating Instructions.

TurboDraft Fire Eductor

Operating Instructions Models and Hydrostatic Test Pumps

D05 Pressure Regulating Valves

OWNER S TECHNICAL MANUAL

Instruction Manual Updated 7/26/2011 Ver. 2.2

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

Flow Material Length. Weight GPM LPM. Style 3095

Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

IFS NUVENT SERIES IWF FOR POTABLE WATER ANTI SLAM AIR RELEASE AND VACUUM BREAK AIR VALVES

TANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING

Instruction & Parts Manual

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

FI-25V OWNER S MANUAL

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Installation of Your SprayMaster System

Operating Instructions Models and Hydrostatic Test Pumps

DS05C,D,G Dial Set Pressure Regulating Valves

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

OPERATING MANUAL LO-CROSS-FLOW CF M

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

STIH) Technical Information Accessories for STIHL cut-off machines / drills. 1. New pressurized water tank

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

GRAPHIC DIVISION. 3D drawings available at

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

CAST IRON VALVES FLOAT VALVE

BACK PRESSURE / SUSTAINING

STREAMLINE SHOP SERIES MODEL 30040V OPERATION & PARTS MANUAL

D05T Compact Design Pressure Regulating Valves

Y O U R W A Y IRRIGATION COMPONENTS. adritec.com

VBS-9263 Series. Application. Features. Applicable Literature

BACK PRESSURE / SUSTAINING

Copyright, 2005 GPM Hydraulic Consulting, Inc.

KIT. Small Automatic Water Boosters KIT MODELS

VB-7263 Series. Application. Features. Applicable Literature

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Life Raft - Product Information

accidents which arise due to non-observance of these instructions and the safety information herein.

SCK01 AIR COMPRESSOR KIT WITH QUICK FITTINGS - SPRAY/BLOW/OIL GUN, TYRE INFLATOR & HOSE

Water Pressure Reducing Valves

VB-7273 Series. Application. Features. Applicable Literature

Air Eliminators and Combination Air Eliminators Strainers

TWO POST RAM PACKAGE 55 GALLON

Operating Instructions Model and Hydrostatic Test Pump

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

DS06D,G Dial Set Pressure Regulating Valve

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

KJ4000 Operating Instructions & Parts Manual NSN

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Basic layout 2016 IRRIGATION-MART. Check (Non- Leak) Valve. Friction Fit. Sprinkler. Figure 1 - Hanging Sprinkler & Check Valve Assembly

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

STREAMLINE SHOP SERIES MODEL OPERATION & PARTS MANUAL

1020 Industrial Drive, Orlinda, TN fax

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

SEMI-SUB AND JACK UP DRILL RIGS SPECIALIST CLEANING SERVICES & EQUIPMENT RENTAL SOLUTIONS

Model Series 62 Constant Differential Relay

PORTABLE AFTERCOOLER MODEL CA-700 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL ORIGINAL INSTRUCTIONS

Instruction Manual Updated 5/26/2009 Ver. 2.0

Powers Controls D Day-Night Thermostats

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

AirCannonPlans.Com. High Powered Water Cannon

All information correct as of 25 th September 2013 and subject to change without notice. 6 inch HURRICANE modular dredge equipment operations manual.

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

2. Piggery facilities

SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems

Hydraulic Reliability & Preventive Maintenance Report

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Operating Instructions Part No

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

MULTI-STAGE VACUUM GENERATORS PVP 12 MX and 25 MX

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

SINGLE VALVE WITH LOW-FLOW BYPASS

VOLUMATIC WATER REGULATOR

Vacutrans Instructions

Residential Pressure Booster Systems

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

1200 Series Pressure Regulators

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Transcription:

SKYBOX EMERGENCY PACKAGE USER GUIDE SKYBOX EMERGENCY PACKAGE EMERGENCY UNIT The trusted choice for rapid response potable water solu4ons www.skyjuice.org.au

SKYBOX EMERGENCY FILTRATION PACKAGE The SKYBOX Emergency Package is offered in two configurations. These are: 1) SKYBOX COMPLETE FILTRATION EMERGENCY PACKAGE SFP ( 5000 litre/day potable water capacity) 2) SKYBOX EMERGENCY PUMP & SUPPLY PACKAGE SPSP (where existing filtration assets are available for use) The SKYBOX SFP (Dimension 90 cm x 60 cm x 40 cm ; weight 40 Kgs) The SFP is a self contained immediate solution. It is used for pumping raw water from a swamp, creek or other water source directly to a SkyHydrant Ultrafiltration Unit. A pressure-reducing valve prevents excessive pressurisation of the SkyHydrant. This equipment is ideal for shorter-term operations such as for disasters, emergencies or rapid water supply requirement, such IDP camps and alike. The SKYBOX SPSP (Dimension 80cm x 40 cm x 40 cm ; weight 22 Kgs) The SPSP is a pump and supply derivative, where existing filtration equipment or assets exist, and or, the user has access to existing SkyHydrant units.

INCLUDED IN KIT: HONDA WATER MASTER 1 TRANSFER PUMP Powered with reliable Honda engines, these portable pumps are built tough and reliable for the most demanding of jobs including water transfer. Maximum suction: 7m Engine model: GenTech MHM10 Honda GX25 1.1hp Starting system: recoil Fuel tank capacity: 0.65 L Section and discharge size: 1 inch Max head: 30 m Maximum flow right: 3130 Fluid handling: water/diesel Weight: 6.5 kg SUCTION HOSE KIT Ball float x1 Foot Valve 25mm x 1 Easy Fit male straight coupling 25mm x 2 Socket 25mm x 1 Suction hose 25mm/6m x 1 Lanyard DISC FILTER KIT Reducing socket 25/20mm x 1 Disc filter - yellow 25mm x 1 HOSE KIT Reducing socket 25/20mm x 1 Barrel union 20mm x 2 Layflat hose 20mm/6m x 1 KIT Apex FV 3.7 Pressure Reducing Valve x 1 Pressure Gauge 100kPa x 1 Bush Reducing 20/8mm Bush Reducing 20/15mm Socket 20mm x 1 Tee 20mm x 1 Nipple 20mm x 1 Ball Valve 20mm x 1

OPERATING INSTRUCTIONS START UP Refer to water pump operating instructions. Prior to Starting the pump check the correct water pressure To the SkyHydrant will be supplied either by relying on adjusting the water pump throttle control or using a pressure control unit. If the correct pressure cannot be achieved by throttling the pump, connect a pressure control unit. When using a pressure control unit, turn the ball valve off prior to starting the pump. Once started, adjust the pressure control unit as per instructions below. The Pressure Control Unit should be adjusted to Between 30 to 40 kpa (about 5 psi). Refer to the SkyHydrant user guide for maximum operating pressure. & GUAGE ASSEMBLY The Pressure Reducing Valve and Gauge Assembly can be used to reduce water pressure supplying raw water to a SkyHydrant ultrafiltration unit. It should be located close to the SkyHydrant and be periodically checked to ensure the correct pressure is being maintained. To do this, turn the ball valve off to check the static supply pressure. 1) INLET WATER QUALITY TO THE : Water entering the Pressure Reducing Valve must not contain particles exceeding 250 micron (1/4mm), which could otherwise foul the unit. To prevent fouling, install a pre-filter such as a disc filter, screen filter or media filter. 2) ADJUSTABLE APEX - FV3.7: Specifications: Adjustable pressure range 15 to 100 kpa Maximum Inlet Pressure 2000 kpa Compensated to give constant outlet pressure regardless of inlet pressure. Installation: Can be installed in any orientation. Do not install in the ground. Valve requires adjustment on site. To increase pressure turn the adjusting screw clockwise (1 ½ turns = 1 metre head). After adjustment reset the locknut. When setting the pressure, close the ball valve and adjust the valve to the required pressure as shown on the pressure gauge. Open and close the ball valve a couple of times to ensure the correct pressure is being maintained and make finer adjustments as required. Operating Pressure: Recommended operating pressure for supply to manually operated water filtration unit should not exceed 30 kpa. Note: This is the static pressure as observed on the pressure gauge when the ball valve is closed. Refer to the SkyHydrant User Guide for more information on operating pressures.

DIRECT PUMPING SYSTEM - SUGGETED CONFIGURATIONS Check operations every hour to ensure the correct pressure is maintained. If necessary, make adjustments to the system operating pressure. Note: The SkyHydrant ultrafiltration unit requires regular cleaning to maintain a desirable water flow. If the raw water supply is excessively turbid additional cleaning will need to be undertaken. A pre-filter may also be needed. After each cleaning cycle the pump and pressure control unit may need to be reset. Refer to the SkyHydrant User Guide for more information. FILTRATE STORAGE OPTIONS Rigid tank Collapsible tank TAPS TANK STAND OR PLATFORM DRINKING WATER OUTLET Direct Pumping & Tank Stand Setup TAP STAND BLADDER TANK ON SAND BAGS, MOUND OR ON 44 GALLON DRUMS Direct Pumping & Elevated Bladder UNIT or MULTIPLE UNITS WATER BLADDER PUMP TANKER TRUCK Direct Pumping & Filtrate Bladder Setup