NO. TO THE DRAWINGS AND THE PROJECT MANUAL PROJECT NAME: Duncanville I.S.D. Safety, Security & Maintenance Package 2 CLIENT NAME: Duncanville I.S.D. LOCATION: Duncanville, Texas PROJECT NUMBER: 688-05 PROPOSAL DATE: Thursday, May 26 th,206 2:00 PM ADDENDUM DATE: Friday, May, 20th, 206 For additional information regarding this project, contact Jesus Rodriguez at 800.687.229. THIS ADDENDUM INCLUDES: Civil Items 0 Pages Landscape Items 0 Pages Structural Items 0 Pages Architectural Items 2 Pages Foodservice Items 0 Pages Plumbing Items 0 Pages Mechanical Items 0 Pages Electrical Items 0 Pages Technology Items 0 Pages AND ALL ATTACHED REVISED DRAWING REFERENCES IN THE ADDENDUM
Project Name: Duncanville I.S.D. Safety, Security & Maintenance Package 2 Client: Duncanville ISD Duncanville, Texas Project Number: 688-05 ARCHITECTURAL ITEMS FOR ADDENDUM NO. NOTICE TO PROPOSERS: A. This Addendum shall be considered part of the contract documents for the above-mentioned project as though it had been issued at the same time and incorporated integrally therewith. Where provisions of the following supplementary data differ from those of the original contract documents, this Addendum shall govern and take precedence. B. Proposers are hereby notified that they shall make any necessary adjustments in their estimate on account of this Addendum. It will be construed that each Proposer s proposal is submitted with full knowledge of all modifications and supplemental data specified therein. Acknowledge receipt of this addendum in the space provided on the proposal form. Failure to do so may subject Proposer to disqualification. REFERENCE IS MADE TO THE DRAWINGS AND THE PROJECT MANUAL AS NOTED: PROJECT MANUAL: AD No, Arch. Item : To the Project Manual, Sections as listed below, Part 2 Products; Products listed herein are considered acceptable for conformance with the design concept of the project and general compliance with the information given in the contract documents. The manufacturer, supplier and installer are responsible for meeting all requirements given in the contract documents unless specifically noted in the written approval. ) To Section 08 433, Aluminum-Framed Storefronts, Model Tubelite Inc. Series T400 Thermal Flush Glaze as manufactured by Tubelite Inc. DRAWINGS: AD No, Arch. Item 2: To the Drawings (Byrd MS), Sheet A3., DOOR SCHEDULE AND CONFIGURATIONS, ) For clarification Existing Original Construction 976 and Field House 99 record drawings do not indicate any existing door ratings. Record drawings can be made available for review upon request. 2) Replace this sheet in its entirety per this addendum. Existing fire ratings have been added to door schedule. AD No, Arch. Item 3: To the Drawings (Central ES), Sheet A3., DOOR SCHEDULE AND CONFIGURATIONS, For clarification 99 Renovation Drawings do not indicate any existing door ratings within door schedule. Record drawings can be made available for review upon request. AD No, Arch. Item 4: To the Drawings (Fairmeadows ES), Sheet A3., DOOR SCHEDULE AND CONFIGURATIONS, For clarification Original Construction 96, Addition 962, Addition 966 and Gym Building 978 Record drawings do not indicate any existing door ratings within door schedule. Doors in main building are listed as 20 Gage NYC Standard Type. Record drawings can be made available for review upon request. 987 Classroom Building Record drawings do not indicate existing door ratings within door schedule. AD No, Arch. Item 5: To the Drawings (Hardin IS), Sheet A3., DOOR SCHEDULE AND CONFIGURATIONS, Replace this sheet in its entirety per this addendum. Existing fire ratings have been added to door schedule. AD No, Arch. Item 6: To the Drawings (Merrifield ES), Sheet A3., DOOR SCHEDULE AND CONFIGURATIONS, For clarification Addition Construction 963 and Gym Building 978 Record drawings do not indicate any existing door ratings within door schedule. Doors in main building are listed as 20 Gage NYC Standard Type. Record drawings can be made available for review upon request. Architectural Items for Addendum No. Page of 2
Project Name: Duncanville I.S.D. Safety, Security & Maintenance Package 2 Client: Duncanville ISD Duncanville, Texas Project Number: 688-05 AD No, Arch. Item 7: To the Drawings (Reed MS), Sheet A3., DOOR SCHEDULE AND CONFIGURATIONS, For clarification 2004 Renovation drawings do not indicate any existing door ratings within door schedule. Record drawings can be made available for review upon request. END OF ARCHITECTURAL ADDENDUM Architectural Items for Addendum No. Page 2 of 2
Copyright 206, Huckabee & Associates, Inc. NOTE: D = SINGLE DOOR, DD = DOUBLE DOORS (PAIR), P = PARTIAL, S = SIDELIGHT, T = TRANSOM. COMBINATIONS OF THESE ARE USED BELOW TO DESCRIBE THE DOOR FRAME TYPES. DOOR WIDTH D OR DD OR CO SIMPLE FRAME/CASED OPENING DOOR FRAME CONFIGURATIONS DR WIDTH DS FULL SIDELIGHT OFFSET EQ. DR WIDTH EQ. SDS FULL SIDELIGHT SYMMETRICAL NOTE: OFFSET CONFIGURATIONS (E.G. "D-S" DOOR/SIDELITE) MAY OCCUR EITHER HAND; REFER TO FLOOR PLANS EQ DR. WIDTH EQ SDST, SDDST, SSDSST OR SSDDSST FULL SIDELIGHT SYMMETRICAL W/ TRANSOM 4' - 0" ' - 0" FL FLUSH DOOR NO GLAZING DOOR CONFIGURATIONS 2-PEEP HOLES PER SCHED, TYP KITCHEN BACK DOOR 6" NL NARROW LITE 2' - 3' - 6" 3' - 2" 2L TWO LITE 0" 2' - 0" FG FULL GLAZED 0" A3 - DOOR ASSEMBLY SCHEDULE(v204) DOOR ASSEMBLY DOOR DESCRIPTION FRAME DESCRIPTION DETAILS AND NOTES MARK FIRE RATE DOOR TYPE WIDTH HEIGHT GLAZING TH. H.O. SEC. FRAME TYPE WIDTH HEIGHT GLAZING HEAD JAMB JAMB SILL NOTES.00A EXIST (PR) 3' - 0" 7' - 0" --- EXIST AL-S-DD-S-T 9' - 7" 0' - 0" -- 2,4,5.00B EXIST (PR) 3' - 0" 7' - 0" --- EXIST AL-S-DD-S-T 8' - 0' - 0" -- 2,4,5.00D EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 4.00F HM-FL (PR.) 3' - 0" 7' - 0" --- XHM-DD 6' - 7' - -- 4,5.00JA EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4.00K EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4.00L EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4.00M EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 4.0A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2.0B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2.02 EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4.03 EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2.04A SC-NL (PR.) 3' - 0" 7' - 0" CTG XHM-DD 6' - 7' - -- 3,4,5.04B SC-NL (PR.) 3' - 0" 7' - 0" CTG XHM-DD 6' - 7' - -- 3,4.04C EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 4.04G SC-NL (PR.) 3' - 0" 7' - 0" --- XHM-DD 6' - 7' - 2" -- 3,5.05A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2.05B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2.06 EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4.06E EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4.07 EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,5 2.00E EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2.00F EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4 2.00G EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4 2.00I EXIST 3' - 0" 7' - 0" --- EXIST HM-D-S 5' - 7' - 2,4 2.0D EXIST 2' - 3" 7' - 0" --- EXIST HM-D 2' - 7" 7' - -- 4 2.02A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 2.02B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 2.03 EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 2.04A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 2.04B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 3.00A EXIST (PR) 3' - 0" 7' - 0" --- EXIST HM-DD 6' - 7' - -- 4 3.00B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 4 3.00C EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4 3.00D EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4 3.00G EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4 3.00H EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4 3.0A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 3.0B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 3.02 EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 3.03A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 3.03B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 3.04 SC-NL 3' - 0" 7' - 0" CTG XHM-D-S-T 5' - 0" 7' - -- 3,5 3.04A SC-NL 3' - 0" 7' - 0" CTG XHM-D 3' - 7' - -- 3,5 3.04B SC-NL 3' - 0" 7' - 0" CTG XHM-D-S-T 6' - 0" 7' - -- 3,5 3.05A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 3.05B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 3.06 45 MINS. EXIST (PR) 3' - 0" 7' - 0" --- EXIST HM-DD 6' - 7' - -- 2,5 3.06A 45 MINS. EXIST (PR) 3' - 0" 7' - 0" --- EXIST HM-DD 6' - 7' - -- 2,6 3.07 45 MINS. EXIST 4' - 0" 7' - 0" --- EXIST HM-D 4' - 7' - -- 2 4.00A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 4.00C EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 4.00D EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 4.00F EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4 4.0A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 4.0B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 4.02A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 4.02B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 4.03A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 4.03B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 4.03D EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 4.03DD EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 4.04A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 4.04B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.00A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 4 5.00D EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 4 5.0 EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.02A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.02B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.03 EXIST (PR) 3' - 0" 7' - 0" --- EXIST HM-DD 6' - 7' - -- 2,5 5.04A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 4 5.04B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.05A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.05B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.06A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.07A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.07B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.08A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.08B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.09A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.09B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.0A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 5.0B EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 6.00 AL-2L 3' - 0" 7' - 0" CTG AL-S-D-S 9' - 7' - CTG 6.00A AL-FG 3' - 0" 7' - 0" CTG XAL-S-D-S-T 3' - 6" 0' - 0" --,3 6.03A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4 6.06 EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 6.0 EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2,4 6. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - -- 2 7.02 EXIST (PR) 3' - 0" 7' - 0" --- EXIST HM-DD 6' - 7' - -- 4 SC - SOLID CORE WOOD AS SCHEDULED AND SPECIFIED DOOR MATERIALS XHM - EXISTING HOLLOW METAL FRAME DOOR FRAME MATERIALS CTG - FRG - GIT - ISG - LTSG - GLAZING LEGEND CLEAR TEMPERED GLASS FIRE RATED GLASS GREY INSULATED TEMPERED GLASS INSULATED SPANDREL GLASS LAMINATED TEMPERED SAFETY GLASS.) ALL GLAZING IS / THICK (U.N.O.). INSULATED GLASS SHALL CONSIST OF AN EXTERIOR LAYER OF GLASS, TINTED AS SPECIFIED, AN INTERIOR LAYER OF CLEAR GLASS, FACTORY SEALED WITH A /2" AIR SPACE. WHERE TEMPERED GLASS IS SPECIFIED, BOTH LAYERS OF INSULATED GLASS SHALL BE TEMPERED. 2.) ANY WINDOW OR GLAZING PANELS LOCATED AT A INTERSTITIAL SPACE OR NOT READILY VISIBLE SHALL HAVE SPANDREL GLASS INSTALLED, REGARDLESS OF ANY NOTATION ELSEWHERE. DEFAULT DOORS IF A DOOR ASSEMBLY APPEARS ON THE FLOOR PLANS BUT IS NOT IDENTIFIED BY A SCHEDULE NUMBER, THE DOOR SHALL BE INCLUDED IN THE BID AS LISTED BELOW. THE CONTRACTOR SHALL REQUEST CLARIFICATION FROM THE ARCHITECT TO DETERMINE WHAT THE ACTUAL DOOR AND FRAME TYPE AND HARDWARE REQUIREMENTS WILL BE. ADJUSTMENTS IN CONTRACT PRICE WILL BE BASED ON THE DIFFERENCE BETWEEN ACTUAL REQUIREMENTS AND THE DEFAULT DOOR VALUE. THE DEFAULT EXTERIOR DOOR SHALL BE A TYPE "HM-FL" (SINGLE TYPICAL DETAILS FOR EXTERIOR DOORS. THE DEFAULT INTERIOR DOOR SHALL BE A TYPE "SC-FL" (SINGLE TYPICAL DETAILS FOR INTERIOR DOORS. TYPICAL NOTES A) DOOR AND FRAME TYPES ARE INDICATED AS A MATERIAL- CONFIGURATION CODE. THE MATERIAL CODE DESIGNATES MATERIALS AND FINISHES AS SPECIFIED. REFER TO SPECIAL NOTES FOR NON-TYPICAL FINISHES. THE CONFIGURATION CODE REFERS TO TYPICAL OR SPECIAL CONFIGURATIONS AS DRAWN. B) DOOR ASSEMBLIES ARE NUMBERED BY ASSEMBLY. MULTIPLE SETS OF DOORS MAY OCCUR IN THE SAME FRAME ASSEMBLY (REFER TO SCHEDULE AND PLAN FOR QUANTITY). DOORS MAY OCCUR IN PAIRS (REFER TO SCHEDULE AND PLAN FOR INCIDENCE). C) FRAME CONFIGURATION IS DIAGRAMMATIC AND NOMINAL. DIMENSIONS SHALL BE ADJUSTED TO ACCOMMODATE DOOR SIZES AS SCHEDULED. WITHIN ANY ASSEMBLY, THE WIDTH OF SIDELITES SHALL BE EQUAL AND SHALL NOT EXCEED 3'-0" U.N.O. D) ALTERNATE FINISHES CAN SOMETIMES HAVE AN IMPACT ON DETAILING (E.G. HALF OR OFFSET SADDLES EMPLOYED IN LIEU OF STANDARD SADDLES WHEN ADJACENT TO THICKER FLOOR FINISHES SUCH AS TERRAZZO OR QUARRY TILE). COORDINATE DETAILS WITH FINAL FINISH SELECTIONS. E) GLAZED FRAMES ASSOCIATED WITH 20-MINUTE OR 45-MINUTE FIRE-RATED DOORS SHALL BE RATED -HOUR. GLAZED FRAMES ASSOCIATED WITH 90-MINUTE FIRE-RATED DOORS SHALL BE RATED 2-HOUR. GLAZING MUST MEET CODE REQUIREMENTS, INCLUDING SIZE LIMITATIONS, IN FIRE-RATED FRAMES. F) PROVIDE 2x BLOCKING @ MTL STUD WALLS FOR WALL MOUNTED ITEMS LIKE; WALL STOPS, HOLD OPENS ETC. SPECIAL NOTES:. PROVIDE ACCESS CONTROL - REF ELEC AND TECH. SHEETS 2. REPLACE DOOR HARDWARE - PROVIDE INTRUSION HARDWARE 3. EXISTING DOOR LEAF TO BE REPLACE WITH NEW LEAF. PROVIDE NEW HARDWARE. EXISTING FRAME TO REMAIN - PATCH AND REPAIR AS REQUIRED. CONTRACTOR TO FIELD VERIFY AND CATALOG EXISTING DOOR LEAF SIZE PRIOR TO PURCHASE OF NEW DOOR LEAF. NEW DOOR LEAF TO MATCH EXISTING ADJACENT DOOR LEAVES. 4. REFER TO DOOR HARDWARE SETS FOR SCOPE OF WORK. 5. PROVIDE PANIC HARDWARE. REFER TO DOOR HARDWARE SETS. 6. EXISTING PANIC HARDWARE TO REMAIN. COORDINATE SCOPE WITH DOOR HARDWARE GROUPS. DOOR ASSEMBLY NOTES Revision / Date 5/20/6 ADDENDUM# Project: DUNCANVILLE I.S.D. SAFETY, SECURITY & MAINTENANCE PACKAGE 2 BYRD MIDDLE SCHOOL FOR DUNCANVILLE I.S.D. DUNCANVILLE, TEXAS TEM - TEMA- TICF - TICFA - TYP EXT MASONRY DETAIL - HM TYP EXT MASONRY DETAIL - ALUM TYP EXT INSUL CONC FORMS - HM TYP EXT INSUL CONC FORMS - ALUM TIM - TYP INTERIOR MASONRY DETAIL - HM TIMA - TDW - TYP INTERIOR MASONRY DETAIL - ALUM TYP DRYWALL PARTITION DETAIL - HM 5/4/206 F-252 3'-0" EXCEPT, 6" AT LIGHT POLES LOCATED MORE THAN 3'-0" AWAY FROM PAVED SURFACES LIGHT POLE (BY OTHERS) TDWA- TYP DRYWALL PARTITION DETAIL - ALUM HO - DOOR HOLD OPEN (MAGNETIC OR MANUAL - SEE SPECIAL NOTES FOR MORE INFO) 3/ RADIUS DO NOT USE GROUT UNDER POLE BASE PLATE TH - THRESHOLD SEC - SECURITY CONTACTS (REF. ELEC. AND TECH.) 3' - 0" (VERIFY) ADDITIONAL #4 HOOPS AT OC FOR THE LENGTH OF ANCHOR BOLTS ANCHOR BOLTS GRADE OR PAVEMENT SCHEDULE ABBREVIATIONS C:\Users\jrodriguez\Documents\688-05-0_DISD-MC-Tech-Pkg2_ByrdMS_jrodriguez.rvt 0' - 0" ~ #4 HOOPS AT 2" OC 3" MIN COVER NOTE: /2" DIA SPIRAL AT 2" PITCH MAY BE USED IN LIEU OF HOOPS 2' - 0" DIA CONDUIT (AS REQUIRED BY LIGHT POLE MANUFACTURER) 8 - #6 VERTICAL STEEL FIRM UNDISTURBED SOIL OR COMPACTED STRUCTURAL FILL CONTRACTOR TO VERIFY THAT THE ANCHOR BOLTS FIT INSIDE THE VERTICAL STEEL CAGE. MODIFY DIAMETER AS REQUIRED. TYPICAL LIGHT POLE PIER FOR LIGHT POLES UP TO 30'-0" TALL A3. /2" = '-0" DOOR SCHEDULE AND CONFIGURATIONS Job. No. 688-05-0 Drawn By: IS Date: 5/3/6 Sheet No. A3.
Copyright 206, Huckabee & Associates, Inc. 4' - 0" ' - 0" FL FLUSH DOOR NO GLAZING DOOR CONFIGURATIONS 2-PEEP HOLES PER SCHED, TYP KITCHEN BACK DOOR 6" NL NARROW LITE 2' - 3' - 6" SF STORE FRONT - WIDE STILE DOOR NOTE: D = SINGLE DOOR, DD = DOUBLE DOORS (PAIR), P = PARTIAL, S = SIDELIGHT, T = TRANSOM. COMBINATIONS OF THESE ARE USED BELOW TO DESCRIBE THE DOOR FRAME TYPES. DOOR WIDTH D OR DD OR CO SIMPLE FRAME/CASED OPENING EQ DR. WIDTH EQ SDST, SDDST, SSDSST OR SSDDSST FULL SIDELIGHT SYMMETRICAL W/ TRANSOM NOTE: OFFSET CONFIGURATIONS (E.G. "D-S" DOOR/SIDELITE) MAY OCCUR EITHER HAND; REFER TO FLOOR PLANS DOOR FRAME CONFIGURATIONS A3 - DOOR ASSEMBLY SCHEDULE(v204) DOOR ASSEMBLY DOOR DESCRIPTION FRAME DESCRIPTION DETAILS AND NOTES MARK FIRE RATE DOOR TYPE WIDTH HEIGHT GLAZING TH. H.O. SEC. FRAME TYPE WIDTH HEIGHT GLAZING HEAD JAMB JAMB SILL NOTES.0 20 MINS. SC-NL (PR) 3' - 0" 7' - 0" FRG HM-DD 6' - 7' - 2" -- T.D.W. T.D.W. T.D.W. 4.02 20 MINS. EXIST (PR) 3' - 0" 7' - 0" --- EXIST HM-DD 6' - 7' - -- 2.03 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2.04 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2.05 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2.06 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2.07 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2.08 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 2.0 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 2.02 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 2.03 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 2.04 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 2.05 20 MINS. EXIST (PR) 3' - 0" 7' - 0" --- EXIST HM-DD 6' - 7' - -- 2 2.09 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 4 2.0 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D-S-T 6' - 2" 7' - 2" -- 2 3.0 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 3.02 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 3.03 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 3.04 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 4.0 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 4.02 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 4.03 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 4.04 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 4.05 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 5.0 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 5.02 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 5.03 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 5.04 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 6.0 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 6.02 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 6.03 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 6.04 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 7.0 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 7.02 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 7.03 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 7.04 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 8.0 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 8.02 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 8.03 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 8.04 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 8.05 20 MINS. AL-SF 3' - 0" 7' - 0" CTG XAL-S-DD-S-T 6' - 0' - 0" -- T.D.W. T.D.W. T.D.W. 3,5 8.08A EXIST 2' - 0" 7' - 0" --- EXIST HM-D 7' - 2" -- 4 9.0A 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D-S-T 7' - 6" 7' - 2" -- 2 9.0B 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D-S-T 7' - 6" 7' - 2" -- 2 9.02 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 9.03 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 9.06 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 9.07 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 9.08 20 MINS. SC-FL 3' - 0" 7' - 0" -- HM-D 3' - 7' - 2" -- 0.00 SC-NL 3' - 0" 7' - 0" CTG HM-D 3' - 7' - 2" -- T.D.W. T.D.W. T.D.W. 0.0 EXIST 3' - 0" 7' - 0" -- EXIST AL-D-S-T 7' - 2" 8' - 0" 0.05 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 0.06A EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 0.06B 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 0.07 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 0.08 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 2 0.09 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 4 0.0 20 MINS. EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 4 0.20 EXIST 3' - 0" 7' - 0" --- EXIST HM-D 3' - 7' - 2" -- 4 UNLESS NOTED OTHERWISE ALL H.M. FRAMES IN DRYWALL SHALL CONFORM TO THESE DETAILS OF GYP. BD. EA. SIDE OF MTL. STUDS OF GYP. BD. EA. SIDE OF MTL. STUDS IFIED. 2" W.T. FRAME DEPTH = W.T. + / TYP. DOOR/WDW HEAD DETAIL 3 /2" BATT INSUL. CERAMIC TILE WHEN IT OCCURS CONT. SEALANT AT CERAMIC TILE 2X WOOD BLOCKING WHERE ALUM. FRAME OCCURS - REF. PLAN 3 /2" BATT INSUL. TYP. DOOR/WDW JAMB DETAIL VERIFY WALL THICKNESS TO DETERMINE FRAME SIZES. OF GYP. BD. EA. SIDE OF MTL. STUDS PROVIDE 3 MTL STUDS AT EACH JAMB PROVIDE 3 JAMB ANCHORS @ EA JAMB. SC - SOLID CORE WOOD AS SCHEDULED AND SPECIFIED XHM - EXISTING HOLLOW METAL FRAME DOOR MATERIALS DOOR FRAME MATERIALS CTG - FRG - GIT - ISG - LTSG - GLAZING LEGEND CLEAR TEMPERED GLASS FIRE RATED GLASS GREY INSULATED TEMPERED GLASS INSULATED SPANDREL GLASS LAMINATED TEMPERED SAFETY GLASS.) ALL GLAZING IS / THICK (U.N.O.). INSULATED GLASS SHALL CONSIST OF AN EXTERIOR LAYER OF GLASS, TINTED AS SPECIFIED, AN INTERIOR LAYER OF CLEAR GLASS, FACTORY SEALED WITH A /2" AIR SPACE. WHERE TEMPERED GLASS IS SPECIFIED, BOTH LAYERS OF INSULATED GLASS SHALL BE TEMPERED. 2.) ANY WINDOW OR GLAZING PANELS LOCATED AT A INTERSTITIAL SPACE OR NOT READILY VISIBLE SHALL HAVE SPANDREL GLASS INSTALLED, REGARDLESS OF ANY NOTATION ELSEWHERE. DEFAULT DOORS IF A DOOR ASSEMBLY APPEARS ON THE FLOOR PLANS BUT IS NOT IDENTIFIED BY A SCHEDULE NUMBER, THE DOOR SHALL BE INCLUDED IN THE BID AS LISTED BELOW. THE CONTRACTOR SHALL REQUEST CLARIFICATION FROM THE ARCHITECT TO DETERMINE WHAT THE ACTUAL DOOR AND FRAME TYPE AND HARDWARE REQUIREMENTS WILL BE. ADJUSTMENTS IN CONTRACT PRICE WILL BE BASED ON THE DIFFERENCE BETWEEN ACTUAL REQUIREMENTS AND THE DEFAULT DOOR VALUE. THE DEFAULT EXTERIOR DOOR SHALL BE A TYPE "HM-FL" (SINGLE TYPICAL DETAILS FOR EXTERIOR DOORS. THE DEFAULT INTERIOR DOOR SHALL BE A TYPE "SC-FL" (SINGLE TYPICAL DETAILS FOR INTERIOR DOORS. TYPICAL NOTES A) DOOR AND FRAME TYPES ARE INDICATED AS A MATERIAL- CONFIGURATION CODE. THE MATERIAL CODE DESIGNATES MATERIALS AND FINISHES AS SPECIFIED. REFER TO SPECIAL NOTES FOR NON-TYPICAL FINISHES. THE CONFIGURATION CODE REFERS TO TYPICAL OR SPECIAL CONFIGURATIONS AS DRAWN. B) DOOR ASSEMBLIES ARE NUMBERED BY ASSEMBLY. MULTIPLE SETS OF DOORS MAY OCCUR IN THE SAME FRAME ASSEMBLY (REFER TO SCHEDULE AND PLAN FOR QUANTITY). DOORS MAY OCCUR IN PAIRS (REFER TO SCHEDULE AND PLAN FOR INCIDENCE). C) FRAME CONFIGURATION IS DIAGRAMMATIC AND NOMINAL. DIMENSIONS SHALL BE ADJUSTED TO ACCOMMODATE DOOR SIZES AS SCHEDULED. WITHIN ANY ASSEMBLY, THE WIDTH OF SIDELITES SHALL BE EQUAL AND SHALL NOT EXCEED 3'-0" U.N.O. D) ALTERNATE FINISHES CAN SOMETIMES HAVE AN IMPACT ON DETAILING (E.G. HALF OR OFFSET SADDLES EMPLOYED IN LIEU OF STANDARD SADDLES WHEN ADJACENT TO THICKER FLOOR FINISHES SUCH AS TERRAZZO OR QUARRY TILE). COORDINATE DETAILS WITH FINAL FINISH SELECTIONS. E) GLAZED FRAMES ASSOCIATED WITH 20-MINUTE OR 45-MINUTE FIRE-RATED DOORS SHALL BE RATED -HOUR. GLAZED FRAMES ASSOCIATED WITH 90-MINUTE FIRE-RATED DOORS SHALL BE RATED 2-HOUR. GLAZING MUST MEET CODE REQUIREMENTS, INCLUDING SIZE LIMITATIONS, IN FIRE-RATED FRAMES. F) PROVIDE 2x BLOCKING @ MTL STUD WALLS FOR WALL MOUNTED ITEMS LIKE; WALL STOPS, HOLD OPENS ETC. SPECIAL NOTES:. PROVIDE ACCESS CONTROL.- REF. ELEC AND TECH SHEETS. 2. REPLACE DOOR HARDWARE- PROVIDE INTRUSION HARDWARE. 3. EXISTING DOOR LEAF TO BE REPLACE WITH NEW LEAF. PROVIDE NEW HARDWARE. EXISTING FRAME TO REMAIN-PATCH AND REPAIR AS REQUIRED. CONTRACTOR TO FIELD VERIFY AND CATALOG EXISTING DOOR LEAF PRIOR TO PURCHASE OF NEW DOOR LEAF. NEW DOOR LEAF TO MATCH EXISTING ADJACENT DOOR LEAFS. 4.REFER TO DOOR HARDWARE SETS FOR SCOPE OF WORK. 5. PROVIDE PANIC HARDWARE. REFER TO DOOR HARDWARE SETS. DOOR ASSEMBLY NOTES Revision / Date 5/20/6 ADDENDUM# Project: DUNCANVILLE I.S.D. SAFETY, SECURITY & MAINTENANCE PACKAGE 2 HARDIN INTERMEDIATE FOR DUNCANVILLE I.S.D. DUNCANVILLE, TEXAS TYP. WINDOW SILL DETAIL TEM - TYP EXT MASONRY DETAIL - HM TYPICAL DRYWALL DETAILS (T.D.W.) SCALE -/2" = '-0 TEMA- TICF - TYP EXT MASONRY DETAIL - ALUM TYP EXT INSUL CONC FORMS - HM TICFA - TYP EXT INSUL CONC FORMS - ALUM TIM - TYP INTERIOR MASONRY DETAIL - HM TIMA - TDW - TDWA- TYP INTERIOR MASONRY DETAIL - ALUM TYP DRYWALL PARTITION DETAIL - HM TYP DRYWALL PARTITION DETAIL - ALUM HO - DOOR HOLD OPEN (MAGNETIC OR MANUAL - SEE SPECIAL NOTES FOR MORE INFO) TH - THRESHOLD SEC - SECURITY CONTACTS (REF. ELEC. AND TECH.) SCHEDULE ABBREVIATIONS C:\Users\jrodriguez\Documents\688-05-0_DISD-MC-Tech-Pkg2_HardinIS_jrodriguez.rvt DOOR SCHEDULE AND CONFIGURATIONS Job. No. 688-05-04 Drawn By: JR Date: 5/3/6 Sheet No. A3.