Table of Contents - Protec Filters

Similar documents
Table of Contents - ALpHA Filters

Table of Contents - Chemdyne Filters

Table of Contents - EverLUX Filters

Table of Contents - Ultradyne Filters

NEW. Rosedale General Service Membrane Filter Cartridges. Cost effective units for industrial applications

Process Filtration From Pure to Sterile

Assembly and Installation Procedures

Sterile Sampling Bottle Assembly

Sterile Sampling Bottle Assembly

Stainless Steel 142 mm Filter Holder YY

A Perspective on Filter Cartridge Issues

Providing the Benefits of Seitz Filter Media in the Most Versatile Capsule Format Available

Standard Flexel 3D bioprocessing bags for Palletank

Tank Blanketing Pressure Regulators RHPS Series

Instructions For Use USD3156. Kleenpak Capsule with Pegasus Protect Prefiltration Membrane

JSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves

BIOCLOSURE SYSTEM ASSEMBLIES

Chemgard Filter Housings

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves.

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

CVS10 Sanitary Check Valves

GREIG FILTERS, INC. OPERATION MANUAL

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

CS10-1 Stainless Steel Clean Steam Separator

VALVES & MEASUREMENT

LRS(H)4 Pressure-Reducing Regulator User Manual

KEYSTONE. A C E C O E n v i r o n m e n t a l C o m p a n y. Bulletin 10-B

JR Series. Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE

Mark 958 Series Sanitary Gas Back Pressure Regulators

HIGH-PRESSURE RELIEF VALVES

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Avenger Model 33M Installation & Operation Instructions

2D Labtainer BioProcess Container (BPC) systems

RD(H)20/25 Pressure-Reducing Regulator User Manual

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

JR Series. Gas Pressure Reducing Valves. a division of Jordan Valve GAS PRESSURE REDUCING VALVES

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

Discussion and guidance on the definition and qualification of porous loads

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

Quality filter cartridges and customized housings.

JSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

SRV66 Sanitary Pressure Reducing Valve

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Description Advanced Features Typical Applications

BT6-B Sanitary Balanced Pressure Thermostatic Steam Trap

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

INDUSTRIAL EXCESS ESS FLOW VALVES

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

Guardian Membrane Separators

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

4400 TwinHybrid Gas Seal

TECHNICAL DATA. Page 1 of 12

INSTALLATION AND OPERATION MANUAL CHEMICAL BYPASS FEEDER General Instructions Regarding All Models

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

Technical Information

Types S100K and S102K Pressure Regulators

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Horizontal Bladder Tanks

DTG - LCD Digital Temperature Gauge USER MANUAL

829S1 Series Flexflo Pilot

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

OVERVIEW METCELL SPECIFICATIONS. Lab scale nanofiltration equipment The METcell Range

Type 4708 Supply Pressure Regulator

Mark 958 Series (3/4" - 1") Sanitary Gas Back Pressure Regulators

TECHNICAL INFORMATION

FloWash. Industrial Filter Cart

HAYWARD FLOW CONTROL FLV SERIES, PVC/CPVC FILTER VESSEL INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Vertical Bladder Tanks

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

AVM7 Stainless Steel Thermostatic Air Vent

Proportional Relief Valves

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Operation Manual Piston Sensed Gas Pressure Regulators

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

GILMONT ACCUCAL FLOWMETERS

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Transcription:

Protec Filters 1

Table of Contents - Protec Filters Materials of Construction 3 Dimensions 4 Operating Characteristics 5 Cartridge Installation Instructions 6 Autoclave Instructions 7 Inline Steam Sterilization Procedure 8 Storage and Shelf Life 9 Protec Media Grade Descriptions 10 Cartridge Ordering Matrix Description 11 Small Flow Elements (SFE Filters) Ordering Matrix Description 12 Capsule (CS/CL) Ordering Matrix Description 13 Capsule (CF) Ordering Matrix Description 14 Capsule (CM/CK) Ordering Matrix Description 15 UltraCap (T-Style & Inline) Ordering Matrix Description 16 UltraCap H.D. (T-Style & Inline) Ordering Matrix Description 17 Protec GD007-2.2 Filters 2

Protec Filters Protec is a borosilicate glass fiber prefilter that offers a high critical degree of retention and provides outstanding protection of more expensive downstream sterilizing filters. The filter is optimized for bioburden reduction as well as removal of colloidal contaminants, aggregated and non-product proteins, lipids and other particles in a broad range of biopharmaceutical applications. It is ideal for prefiltration and clarification of biologicals, protein solutions, vaccines, fermentation broths, cell culture media, serum and plasma fractions. The Protec filter protects final membrane filters in processing solutions with high particle loads and high bioburden. Materials of Construction The Protec filter is manufactured using high quality components made from non-toxic and biologically inert raw materials. All components of the Protec filter are FDA listed for food contact use in the Code of Federal Regulations (CFR), Title 21 as below: Components Media: RF (single layer) Borosilicate glass microfiber CFR Title 21, 177.2420 RM (double layer) Borosilicate glass microfiber (outer layer), CFR Title 21, 177.2420 Polyvinylidene fluoride membrane (inner layer) CFR Title 21, 177.2510 Upstream/Downstream support: Polypropylene CFR Title 21, 177.1520 Core/Outer guard: Polypropylene CFR Title 21, 177.1520 End caps/adaptors: Polypropylene CFR Title 21, 177.1520 Capsule housing: Polypropylene CFR Title 21, 177.1520 O-rings: Buna, EPR or Silicone CFR Title 21, 177.2600 Teflon over Silicone or CFR Title 21, 177.1550 Teflon over Viton Sealing method: Thermal bonding The Protec filter meets requirements as specified in the current USP Class VI plastics and cytotoxicity tests. Configurations Protec can be ordered in a variety of configurations from SFE filter cartridges through UltraCap high capacity capsule filters. SFE Cartridge Cartridge CL CS CF CK CM T-Style Inline T-Style Inline Capsule UltraCap UltraCap H.D. Protec Filters 3

Dimensions Length EFA** EFA Cartridge Diameter (nominal) (RF Grade) (RM Grade) 2.75" (7 cm) 10" (25 cm) 6.4 ft 2 (0,59 m 2 ) 5.7 ft 2 (0,53 m 2 ) 20" (50 cm) 12.8 ft 2 (1,19 m 2 ) 11.4 ft 2 (1,06 m 2 ) 30" (75 cm) 19.2 ft 2 (1,78 m 2 ) 17.1 ft 2 (1,59 m 2 ) 40" (100 cm) 25.6 ft 2 (2,38 m 2 ) 22.8 ft 2 (2,12 m 2 ) Length EFA EFA SFE Cartridge Diameter (nominal) (RF Grade) (RM Grade) 2.25" (5,7 cm) 2.5" (6,4 cm) 1.0 ft 2 (0,09 m 2 ) 0.86 ft 2 (0,08 m 2 ) 5" (12,7 cm) 2.0 ft 2 (0,19 m 2 ) 1.7 ft 2 (0,16 m 2 ) Length EFA EFA Capsule Diameter (nominal) (RF Grade) (RM Grade) CL/CL2 2.75" (7,0 cm) 6.9" (17,5 cm) 2.0 ft 2 (0,19 m 2 ) 1.7 ft 2 (0,16 m 2 ) CS/CS2 2.75" (7,0 cm) 4.5" (11,4 cm) 1.0 ft 2 (0,09 m 2 ) 0.86 ft 2 (0,08 m 2 ) CF2-A 2.25" (5,7 cm) 3.3" (8,3 cm) 0.33 ft 2 (305 cm 2 ) 0.28 ft 2 (260 cm 2 ) CF2-B 2.25" (5,7 cm) 3.3" (8,3 cm) 0.50 ft 2 (465 cm 2 ) 0.42 ft 2 (390 cm 2 ) CK2 1.25" (3,2 cm) 6.25" (15,9 cm) 0.36 ft 2 (335 cm 2 ) 0.33 ft 2 (305 cm 2 ) CM2 1.25" (3,2 cm) 5.50" (14,0 cm) 0.29 ft 2 (270 cm 2 ) 0.26 ft 2 (240 cm 2 ) Length Capsule Dimension EFA EFA UltraCap Diameter * (nominal) (overall) (RF Grade) (RM Grade) T-style 3.25" (8 cm) 10" (25 cm) 12.2" (31 cm) 6.4 ft 2 (0,59 m 2 ) 5.7 ft 2 (0,53 m 2 ) 20" (50 cm) 21.8" (55,4 cm) 12.8 ft 2 (1,19 m 2 ) 11.4 ft 2 (1,06 m 2 ) 30" (75 cm) 31.5" (80 cm) 19.2 ft 2 (1,78 m 2 ) 17.1 ft 2 (1,59 m 2 ) Inline 3.25" (8 cm) 10" (25 cm) 14.8" (37,6 cm) 6.4 ft 2 (0,59 m 2 ) 5.7 ft 2 (0,53 m 2 ) 20" (50 cm) 24.5" (62,2 cm) 12.8 ft 2 (1,19 m 2 ) 11.4 ft 2 (1,06 m 2 ) 30" (75 cm) 34.1" (86,6 cm) 19.2 ft 2 (1,78 m 2 ) 17.1 ft 2 (1,59 m 2 ) Length Capsule Dimension EFA EFA UltraCap H.D. Diameter * (nominal) (overall) (RF Grade) (RM Grade) T-style 3.5" (9 cm) 10" (25 cm) 11.7" (29,7 cm) 6.4 ft 2 (0,59 m 2 ) 5.7 ft 2 (0,53 m 2 ) 20" (50 cm) 21.1" (53,6 cm) 12.8 ft 2 (1,19 m 2 ) 11.4 ft 2 (1,06 m 2 ) 30" (75 cm) 30.6" (77,7 cm) 19.2 ft 2 (1,78 m 2 ) 17.1 ft 2 (1,59 m 2 ) 40" (100 cm) 40.0" (101,6 cm) 25.6 ft 2 (2,38 m 2 ) 22.8 ft 2 (2,12 m 2 ) 50" (125 cm) 49.5" (125,7 cm) 32.0 ft 2 (2,97 m 2 ) 28.5 ft 2 (2,65 m 2 ) Inline 3.5" (9 cm) 10" (25 cm) 17.3" (43,9 cm) 6.4 ft 2 (0,59 m 2 ) 5.7 ft 2 (0,53 m 2 ) 20" (50 cm) 26.8" (68,1 cm) 12.8 ft 2 (1,19 m 2 ) 11.4 ft 2 (1,06 m 2 ) 30" (75 cm) 36.2" (91,9 cm) 19.2 ft 2 (1,78 m 2 ) 17.1 ft 2 (1,59 m 2 ) 40" (100 cm) 45.7" (116,1 cm) 25.6 ft 2 (2,38 m 2 ) 22.8 ft 2 (2,12 m 2 ) 50" (125 cm) 55.2" (140,2 cm) 32.0 ft 2 (2,97 m 2 ) 28.5 ft 2 (2,65 m 2 ) *inlet/outlet fittings extend beyond stated diameter **EFA = Effective Filtration Area Protec Filters 4

Operating Characteristics Cartridges and SFE (Small Flow Elements) Maximum Operating Temperatures and Pressures 80 psid @ 32 F to 100 F ( p 5,5 bar @ 0 C to 38 C) 60 psid @ 150 F ( p 4,1 bar @ 66 C) 30 psid @ 180 F ( p 2,1 bar @ 82 C) Capsules - CS/CL & CF Models Maximum Operating Pressure, Liquids Maximum Operating Pressure, Gas 75 psig @ 32 F to 100 F 50 psig @ 32 F to 100 F (5,2 bar @ 0 C to 38 C) (3,4 bar @ 0 C to 38 C) Maximum Operating Temperature Rating 160 F @ 35 psig (71 C @ 2,4 bar) Capsules - CM/CK Models Maximum Operation Pressure & Temperature, Liquids Maximum Operating Pressure & Temperature, Gas 100 psig @ 32 F to 122 F 100 psig @ 32 F to 122 F (6,9 bar @ 0 C to 50 C) (6,9 bar @ 0 C to 50 C) UltraCap Model Maximum Operating Pressure & Temperature, Liquids Maximum Operating Pressure & Temperature, Gas 75 psig @ 32 F to 100 F 50 psig @ 32 F to 100 F (5,2 bar @ 0 C to 38 C) (3,4 bar @ 0 C to 38 C) 45 psig @ 140 F 30 psig @ 140 F (3,1 bar @ 60 C) (2,1 bar @ 60 C) UltraCap H.D. Model Maximum Operating Pressure & Temperature, Liquids Maximum Operating Pressure & Temperature, Gas 90 psig @ 32 F to 100 F 60 psig @ 32 F to 100 F (6,2 bar @ 0 C to 38 C) (4,1 bar @ 0 C to 38 C) 55 psig @ 140 F 35 psig @ 140 F (3,8 bar @ 60 C) (2,4 bar @ 60 C) Protec Filters 5

Cartridge Installation Instructions Meissner filters are available in a number of different adapter and O-ring configurations designed to fit modern filter housings. The filter should fit snugly in the housing. Improper installation can impair filtration efficiency. 1. Verify that the correct filter part number for the application has been chosen. 2. Keep the filter in its plastic bag to avoid contaminating the cartridge as long a possible. Cut open the bag at the O-ring end. While holding the bagged cartridge, lubricate the O-rings by dipping the O-rings into clean water or other suitable liquid compatible with the process fluid. 3. Line up the open end of the cartridge with the housing seat and install using a slight twisting motion while holding the bagged cartridge near the O-ring adapter. Verify that the O-rings are fully seated and not twisted. If the cartridge has locking tabs, rotate the tabs into place with a clockwise motion until engaged. Caution: always rotate cartridges while firmly grasping the O-ring end of the cartridge to prevent excessive torque damage to the filter. 4. Repeat with additional cartridges. Remove protective bags from the cartridges. If present, install cartridge retainer system (plate or spring). Reassemble housing. Protec Filters 6

Autoclave Instructions Meissner filters may be autoclaved repeatedly without loss of integrity. Capsule, UltraCap and UltraCap H.D. Filters The following outlines the steps recommended in the autoclave sterilization of Meissner filter capsules. 1. Loosely cover the capsule inlet and outlet with autoclave wrap. All capsule vents are on the upstream side of the filter and should be loosened or removed to facilitate steam penetration. Hose barb vent valves must be opened at least two full turns to prevent valve leakage post autoclaving. 2. The weight of clamps or fittings attached to the capsule must be supported to avoid damaging the adapters. Sanitary flanges may have clamps and gaskets loosely attached to the filter. If fittings must be attached to flanges, tri-clamps are preferable to bi-clamps and should be tightened after the assembly has cooled. 3. Autoclave the capsule at a minimum of 121 C for 60 minutes or 125 C for at least 45 minutes with the capsule in a horizontal position using a slow exhaust or liquid cycle. T-style UltraCap capsules may be autoclaved horizontally or with the outlet oriented downward to facilitate the removal of condensate from the downstream side of the filter. As autoclave systems vary, sterilization cycles should be validated under actual system or autoclave loading conditions. Downstream attachments can significantly increase the time required to sterilize the filter core. 4. Allow the capsule to cool. Install filter into system aseptically. Cartridge and SFE (Small Flow Elements) The following outlines the steps required to autoclave a Meissner filter cartridge and housing assembly. A stainless steel reinforcement ring is required for filter configurations with 222 or 226 O-rings. 1. Install the filter into the housing. Loosely cover the inlet and outlet with autoclave wrap. Vent and drain valves should be fully open. 2. Autoclave the cartridge and housing assembly at a minimum of 121 C for 30 minutes with the filter outlets in an outlet down or horizontal position using a slow exhaust or liquid cycle. As autoclave systems vary, sterilization cycles should be validated under actual system or autoclave loading conditions. Assemblies attached to the outlet can increase the required sterilization times. 3. Allow the housing assembly to cool. 4. Install the sterile filter assembly into the system using aseptic techniques. Different autoclave temperature and time combinations may be used to sterilize the filters but the combination should be validated to ensure that sterilization occurs under those conditions. Temperatures above 135 C are not recommended. Protec Filters 7

Inline Steam Sterilization Procedure Steaming in place (SIP) is frequently used in critical applications where a sterile effluent is desired. To prevent damage to the filter cartridge s O-ring adapter, cartridges with 222 or 226 O-ring adapters must be reinforced with a stainless steel ring. Protec filter cartridges with reinforced O-ring adapters are capable of repeated sterilization cycles without loss of integrity. The steps required to steam sterilize the Protec filter cartridge and system using saturated steam are outlined in the procedure, below. The steam should be free of rust and other particulates. The housing should be clean before the cartridge is installed. If you are steam sterilizing a wetted cartridge, upstream and downstream gauges must be provided to verify that the differential pressure across the membrane does not exceed 5 psi (0,3 bar). To assure sterilization, steam pressure in the assembly must not be allowed to fall below 15 psi (1 bar) or 121 C. Condensate should be drained from the system during sterilization. A typical piping schematic is outlined in Figure 1. Caution: Capsules, UltraCap and UltraCap H.D. are not designed for inline steam sterilization! Procedure (Figure 1) 1. Close all valves. 2. Open valve V 4. 3. If cartridge is wet, or if there is a large volume tank downstream of the filter, open V 5. a. Slowly open V 2. This will connect both sides of the filter to steam pressure. b. Crack open V 7 to vent trapped air. c. Crack open V 6 allowing steam to flow through the system. d. Slowly close V 5 but do not allow the differential pressure across the cartridge to exceed 5 psi (0,3 bar). e. Leave drain V 8 cracked during sterilization to drain condensate. 4. If sterilizing a dry cartridge, slowly open V 2. a. Crack open V 7 to vent trapped air. b. Crack open V 6 to allow steam to flow through the system. Do not allow the differential pressure across the cartridge to exceed 5 psi (0,3 bar). c. Leave drain V 8 cracked during sterilization to drain condensate. 5. Steam sterilize for 30 to 60 minutes at 15 to 20 psig (1,0 to 1,4 bar), or as long as experience dictates. 6. When sterilization is complete, close V 2. 7. Open V 3 and introduce sterile air or nitrogen regulated to the same pressure as the steam. 8. Close V 8 once steam and condensate flow stops. 9. Allow the system to cool to room temperature. Do not allow the differential pressure across the cartridge to exceed 5 psi (0,3 bar). Then close V 3, V 7 and V 6. Keep the system under pressure until ready for use. 10. Crack vent V 7 and allow the system pressure to equalize. The filtration process may now be started. V7 P1 P2 Process Fluid Steam Filtered Air V1 V2 V3 V4 V8 V5 Figure 1 V6 Protec Filters 8

Storage and Shelf Life Meissner manufactures a complete line of filter products and One-Touch single use assemblies. Products are suitably bagged and boxed for shipping and may be stored in the original packaging in a clean dry area between 0 C and 40 C (32 F to 100 F). The following gives the minimum shelf life expectancies for Protec products. Filters The Protec filter has an expected shelf life greater than 5 years in the cartridge, small flow, large and small capsule lines, and disc configurations. Filter product age can be determined from the date on the original Certificate of Conformance. Gamma irradiated filters, which include capsule, UltraCap and UltraCap H.D. capsules have a shelf life of at least 2 years from the date of irradiation. Gamma irradiated capsules are distinguished with part numbers beginning with the letter G. One-Touch Products The One-Touch product line of single-use systems, including but not limited to biocontainers, tubing, and/or filter assemblies, has labeling which identifies the product specific expiration date. The standard shelf life of nonsterile One-Touch products is 2 years from the date of manufacture. These standard time periods may be amended to reflect the various components included in a specific configuration, a change that will be indicated on the product label. Filters that are part of a One-Touch single-use system begin with C and are irradiated once with the One-Touch assembly. Protec Filters 9

Protec Media Grade Descriptions RM = RF = This pleated filter combines an outer layer of borosilicate glass microfiber media with an inner layer of Meissner's proprietary hydrophilic PVDF membrane. A Certificate of Conformance is available on a lot basis. This pleated filter contains a single layer of borosilicate glass microfiber media. A Certificate of Conformance is available on a lot basis. Protec Filters 10

Cartridge Ordering Matrix Description RM 0.5 2 C6 R S Filter Grade Absolute Rating (µm) Cartridge Length End Cap Configuration Reinforcement Ring Option Seal Material (O-ring or Gasket) RM 0.2, 0.3, 0.5 1 = 10" GS = DOE; flat gaskets (9.75", 19.5", (Blank) = Standard - no O-ring Seal 29.25", 39" length filters) reinforcement ring B = Buna RF 0.5, 1 2 = 20" 3 = 30" C1 = SOE; 222 no-ring, button cap end GL = DOE; flat gaskets (20", 30", 40" R = Reinforcement ring length filters) required for autoclave/ SIP applications E = EPR S = Silicone T = Teflon over Silicone C2 = SOE; 222 O-rings, button cap end V = Viton F1 = SOE; 222 no-ring, fin end 4 = 40" X = Teflon over Viton F2 = SOE, 222 O-rings, fin end C5 = C6 = F5 = SOE; 226 no-ring, fin end F6 = SOE; 226 O-rings, fin end DN = RN = SOE; 226 no-ring, button cap end SOE; 226 O-rings, button cap end DOE; internal 120 O-rings SOE; internal 120 O-ring, recessed cap end Gasket Seal B = Buna E = EPR P = Polyethylene S = Silicone T = Teflon V = Viton DA = DOE; internal 213 O-rings RA = SOE; internal 213 O-ring, recessed cap end Protec Filters 11

Small Flow Elements (SFE Filters) Ordering Matrix Description L RM 0.5 5 6 R S L Model Filter Grade Absolute Rating (µm) Filter Length/(Area) nominal Adapter Selection Reinforcement Ring Option O-ring Material L RM 0.2, 0.3, 0.5 For RM grade filters: P = Standard internal 116 O-ring (Blank) = Standard - no reinforcement ring B = Buna 2 = 2.5"/0.86 ft² (0,08 m²) 2 = 222 O-rings (for autoclave/ E = EPR RF 0.5, 1 5 = 5.0"/1.7 ft² (0,16 m²) SIP applications, select R" R = Reinforcement ring - under Reinforcement Ring required only for the S = Silicone Option") 222 and 226 adapter T = Teflon over Silicone when autoclaving or For RF grade filters: 6 = 226 O-ring style locking steam sterilizing V = Viton 2 = 2.5"/1.0 ft² (0,09 m²) adapter (for autoclave/sip applications, select R" under X = Teflon over Viton 5 = 5.0"/2.0 ft² (0,19 m²) Reinforcement Ring Option") SK = Skirt-flange adapter (no reinforcement or O-ring options available) L = 116 O-ring with Mini Lock Protec Filters 12

Capsule (CS/CL) Ordering Matrix Description C S 2 RM 0.5 02 2 Sterile Option Filtration Area (nominal) Material Code Filter Grade Absolute Rating (µm) Inlet/Outlet Connections Vent/Drain Ports C = Standard (nonsterile) For RM grade filter: (Blank) or 1 = S = 0.86 ft² (0,08 m²) Polypropylene capsule shell material RM 0.2, 0.3, 0.5 00 = G = Gamma Irradiated L = 1.7 ft² (0,16 m²) 2 = Animal RF 0.5, 1 component free polypropylene For RF grade filter: capsule shell S = 1.0 ft² (0,09 m²) material L = 2.0 ft² (0,19 m²) 02 = 0C = 22 = 2B = CC = inlet; 3/8" hose barb outlet inlet; 1/2" hose barb outlet 3/8" hose barb 3/8" hose barb with filling bell 1/2" hose barb 0 = No vent/drain port 1 = 2 = 4 = 5 = 1 luer port with cap, outlet side Standard - 2 luer ports with caps 2 sanitary valves with hose barb 1 sanitary valve with hose barb connection, inlet side 44 = 55 = 66 = 1/4" MNPT 3/8" FNPT 3/8" MNPT 77 = 3/4" sanitary flange 88 = 3/4" hose barb 99 = 1/2" hose barb flexible tubing Protec Filters 13

Capsule (CF) Ordering Matrix Description CF 2 RM 0.5 33 A 1 2 Sterile Option Material Code Filter Grade Absolute Rating (µm) Inlet/Outlet Connections Filtration Area (nominal) Vent/Drain Ports CF = Standard (nonsterile) 2 = Animal component free polypropylene capsule shell material RM 0.2, 0.3, 0.5 33 = 3B = Hose barb (1/4" - 3/8") with A = 0.28 ft² (260 cm²) GF = Gamma Irradiated RF 0.5, 1 filling bell B = 0.42 ft² (390 cm²) 41 = 44 = 77 = Hose barb (1/4" - 3/8") 1/4" MNPT inlet; 1/4" hose barb outlet 1/4" MNPT 3/4" sanitary flange For RM grade filter: 0 = No vent/drain port For RF grade filter: A = 0.33 ft² (305 cm²) B = 0.50 ft² (465 cm²) 1 = 2 = 2 luer ports with caps 4 = 5 = Standard - 1 luer port with cap, outlet side 2 sanitary valves with hose barbs 1 sanitary valve with hose barb connection, inlet side Protec Filters 14

Capsule (CM/CK) Ordering Matrix Description C K 2 RM 0.5 77 4 2 Sterile Option Filtration Area (nominal) Material Code Filter Grade Absolute Rating (µm) Inlet/Outlet Connections Vent/Drain Ports C = Standard (nonsterile) For RM grade filter: M = 0.26 ft² (240 cm²) 2 = Animal component free polypropylene capsule shell material G = Gamma Irradiated K = 0.33 ft² (305 cm²) RF 0.5, 1 For RF grade filter: M = 0.29 ft² (270 cm²) K = 0.36 ft² (335 cm²) RM 0.2, 0.3, 0.5 11 = 1/4" hose barb 22 = 44 = 71 = 72 = 77 = 3/8" hose barb 1/4" MNPT 3/4" TC in; 1/4" hose barb out 3/4" TC in; 3/8" hose barb out 3/4" sanitary (TC) flange 0 = No vent/drain port 1 = 2 = 4 = 5 = 1 luer port with cap, outlet side Standard - 2 luer ports with caps 2 sanitary valves with hose barb 1 sanitary valve with hose barb connection, inlet side 6 = 1 sanitary valve with hose barb, outlet side Protec Filters 15

UltraCap (T-Style & Inline) Ordering Matrix Description CU RM 0.5 2 T 00 2 Sterile Option Filter Grade Absolute Rating (µm) Cartridge Length Body Style Inlet/Outlet Connections Vent/Drain Ports T-Style CU = Standard (nonsterile) RM 0.2, 0.3, 0.5 1 = 10" T = T-style 00 = GU = Gamma Irradiated RF 0.5, 1 2 = 20" N = Inline 3 = 30" 77 = 02 = 0C = 09 = 08 = 22 = 3/4" sanitary flange inlet; 3/8" hose barb outlet inlet; 1/2" hose barb outlet inlet; 9/16" hose barb outlet inlet; 3/4" hose barb outlet 3/8" hose barb 0 = No vent or drain 1 = No vent; 1/4" sanitary drain plug 2 = Sanitary vent; 1/4" sanitary drain plug 3 = 4 = Sanitary vent; no drain 5 = 6 = Sanitary vent; 3/4" sanitary flange gauge port; 1/4" sanitary drain plug Sanitary vent; 3/4" sanitary flange gauge port; no drain No vent or drain; 3/4" sanitary flange gauge port CC = 99 = 88 = AA = BB = 1/2" hose barb 9/16" hose barb 3/4" hose barb 1/2" Flaretek 3/4" Flaretek Vent/Drain Ports Inline 0 = 2 = No vent or drain Two sanitary vent/drain valves 4 = One sanitary vent or drain valve, outlet side Protec Filters 16

UltraCap H.D. (T-Style & Inline) Ordering Matrix Description CR 2 RM 0.5 2 T 00 2 2 Sterile Option Material Code Filter Grade Absolute Rating (µm) Cartridge Length Body Style Inlet/Outlet Connections Vent/Drain Ports T-Style CR = Standard (nonsterile) 2 = Animal component free polypropylene capsule shell material RM 0.2, 0.3, 0.5 1 = 10" T = T-style 00 = GR = Gamma Irradiated RF 0.5, 1 2 = 20" N = Inline 3 = 30" 4 = 40" 5 = 50" 77 = 02 = 0C = 09 = 08 = 0D = 22 = 3/4" sanitary flange inlet; 3/8" hose barb outlet inlet; 1/2" hose barb outlet inlet; 9/16" hose barb outlet inlet; 3/4" hose barb outlet inlet; 1" hose barb outlet 3/8" hose barb 0 = No vent or drain 1 = 2 = 3 = 4 = Sanitary vent; no drain 5 = 6 = A = No vent; 1/4" sanitary drain plug Sanitary vent; 1/4" sanitary drain plug Sanitary vent; 3/4" sanitary flange gauge port; 1/4" sanitary drain plug Sanitary vent; 3/4" sanitary flange gauge port; no drain No vent or drain; 3/4" sanitary flange gauge port No vent; sanitary drain valve CC = 99 = 88 = DD = AA = BB = 1/2" hose barb 9/16" hose barb 3/4" hose barb 1" hose barb 1/2" Flaretek 3/4" Flaretek B = C = Sanitary vent; sanitary drain valve Sanitary vent; sanitary drain; 3/4" sanitary flange gauge port Vent/Drain Ports Inline 0 = No vent or drain 2 = 4 = Two sanitary vent/drain valves One sanitary vent or drain valve, outlet side Viton and Teflon are registered trademarks of E. I. du Pont de Nemours and Company. Flaretek is a registered trademark of Entegris, Inc. Protec, UltraCap and UltraCap H.D. are registered trademarks of Meissner Filtration Products, Inc. 2013, 2007 Meissner Filtration Products, Inc. Protec Filters 17