SHMS. Downstream Beamline. Large SHMS/HMS Angles (Config-1) Large SHMS / Min HMS Angle (Config-2) Dan Young Ext /26/2015 1

Similar documents
pdf WATER RETICULATION STANDARD VENTILATION LOUVRE BOXES SINGLE AND DOUBLE DUCT SYSTEMS

3/8" Safety Cable Systems

Parts Manual. Scraper Hitches PH:

VACGEN. Vacuum Components. Product Overview

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

THE ARENA TABLE OF CONTENTS 6 THE ARENA OVERVIEW Dimensions and Tolerances... 2

Table of Contents FIRST 2005 FIRST Robotics Competition Manual: Section 3 The Arena rev B Page 1 of 8

3 THE ARENA 3.1 OVERVIEW Dimensions and Tolerances. [This section includes all modifications through Team Update 10]

5. STRUCTURAL ANALYSIS

Part No (Low Changeover) Part No (High Changeover) Part No (High Changeover)

Parts List for Type S Flowmeters

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Technical Information Cleanfit CUA451

Design Based Anchoring 2009 FORD F-150

Product Catalog and Pricing

Hallscrew Replacement Parts List

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

CRYO INDUSTRIES. Liquid Helium Research Dewars

Hydrostatic Pressure Testing

Rosemount 1195 Integral Orifice Primary Element

OMS Comfort Harness II

Dean Pump Self-Priming Chemical Process Pumps

L21S/SR/ST Glass Level Gauges

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

3200 Dwight Road Suite #100 Elk Grove, CA Ph: Fax: GNB Corporation

S Surge Arresters

Miniball Coulomb Excitation Target Chamber

Vacuum Poppet Valves. Телефон: +7 (499) (многоканальный)

ASME Boiler & Pressure Vessel Code Analysis of the 1497 MHz High-Current Cryomodule Helium Vessel

Foundation Products. Poured In Ground Anchor Bolts E1 - E4. Structural Foundations E5 - E12. Copyright 2016 s Industry Inc. SIE-RA-CMP EN

GAS SUPPLY DESIGN GUIDE

Materials : Forged carbon steel A105N

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

PRO-TOOLS 7616 INDUSTRIAL LANE TAMPA, FLORIDA PHONE FAX

Model PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515

TRAVSMART permanent single-cable horizontal lifeline system

- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted.

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

Tower Accessories & Hardware

Air Mortar User Manual

5k Slickline Lightweight Pressure Control Equipment 4 ID

! CAUTION! ! WARNING! General Information

Reproduction. Not for 27" & 29" TWO STAGE INTERMEDIATE SNOWTHROWERS Parts Manual for M1227E M1227EX M1529E

4400 TwinHybrid Gas Seal

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges

Air Operated Hydraulic Pumping Systems to 50,000 psi

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

Safe-T-Stopper. Gas-Free* Service Tee Renewal and Removal for CenterPoint Energy. *In a controlled gas environment

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

PORTABLE LIGHTNING MAST PROTECTION PLP SERIES INSTRUCTION MANUAL

15000 Series Exhausting Arm - Wall Mount Models: 15076/15106/15146

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

Rate of Flow Valve Series 120

QUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

IECEx Certificate of Conformity Annexe

MSA Confined Space Entry Equipment

B-Too Drilling and Tapping Machine

Variable Temperature Storage Dewar Mount Inserts

Pressure Dump Valve Service Kit for Series 2300 Units

SINGLE VALVE WITH LOW-FLOW BYPASS

EPOXY FITTINGS DIMENSIONS

WELDING POSITIONER MODEL NO:

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed

Design of a Solid Wall Transonic Wind Tunnel

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

GIRARD EQUIPMENT, INC. Specialty Valve Manufacturers for Tank Trailers since 1952

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID

Pressure Dump Valve Service Kit for Series 3000 Units

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

CHAIN LINK FENCE GATE

Vertical Bladder Tanks

Halsey Taylor Owners Manual

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

VALVES & MEASUREMENT

I.H.S INSTALLATION INSTRUCTIONS

Materials : Forged carbon steel A350 LF2

CVS 4150 and 4160 Pressure Controllers

MSA Confined Space Entry Equipment

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

RECOMMENDATION FOR INTERCHANGEABLE FLANGED DRILLING CHOKE DIMENSIONS

GREIG FILTERS, INC. OPERATION MANUAL

Johnston Invar Coupling Johnston Invar Coupling

Advantage Lockers & Bike

3 AND 6 SIDE ARMS, STRAIGHT/TAPERED TOWER SECTIONS

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

E Lightband Compression Tool Operating Procedure

THOR 10 HAMMER CAGE INSTRUCTIONS

Halsey Taylor Owners Manual

GUARDIAN FALL PROTECTION

SIF Exploded Views 10/3/2016

Table for PP. over welding cool-down time 0,10 (PP) time pressure pressure in

John Crane Type 609HTC/ECS (High-Temperature Corrosion Resistant) Sealol Metal Bellows Seal Installation Instructions

Thanks for choosing EJAI SOLAR product

Transcription:

SHMS Dan Young Ext 5255 Downstream Beamline Large SHMS/HMS Angles (Config-1) Large SHMS / Min HMS Angle (Config-2) 1/26/2015 1

10 14.5 SHMS Beam Line Large SHMS/HMS Angles (Configuration-1) SHMS minimum angle is 10 HMS minimum angle is 14.5 These angles allow for larger stepped s to clear Magnets and 1.3 Scatter Angle 1/26/2015 2

10 10.5 SHMS Beam Line Large SHMS /Min HMS Angles (Configuration-2) SHMS minimum angle is 10 HMS minimum angle is 10.5 This configuration has small diameter to nest inside HMS Q1 at Min HMS Angle. does NOT clear 1.3 Scatter Angle 1/26/2015 3

Target Center 0.00 Target Window Flange 29.126 184.575 Section-A Different for Configs 1 & 2 5.548 Bellows/ Gate Valve 1074.989 Current distance value. Maybe adjusted in with the new Spool to interface with new Beam Dump 280.125 Section-B Typical Configs 1 & 2 502.215 Section-C Existing s Typical Configurations 1 & 2 73.400 Section-C New Spool, Bellows, Viewer New Dog Legged Steel Supports New Steel Support Structure Assy Existing 10, 18 and 24 Aluminum Stands and Supports SHMS Downstream Beamline Layout 1/26/2015 4

SHMS Downstream Beamline Scattering Chamber Connection 1/26/2015 5

Target Center 0.00 Scattering Chamber Window Flange 29.126 Transition Configurations 1 & 2 3.288 Bellows 2.260 Gate Valve SHMS Downstream Beamline Scattering Chamber Connection Illustration typical for Large SHMS / HMS Angles and Large SHMS Angle/ Min HMS Angle Configurations 1 and 2 1/26/2015 6

Welded Bellows #225-150 2.25 OD x 1.50 ID CF-Flanges to match Scattering Chamber Window Flange and Gate Valve MDC Gate Valve 2 UHV Manual #302010 Similar to MDC #302002 previously used 2 1/2 inch Gate Valve seals are CF Gaskets in this area CF Flange on SHMS Transition to match Gate Valve SHMS 1 ½ Dia Mount Assembly Transition Different for Configurations 1 & 2 SHMS Downstream Beamline Scattering Chamber Connection Illustration typical for Large SHMS / HMS Angles and Large SHMS Angle/ Min HMS Angle Configurations 1 and 2 1/26/2015 7

SHMS Downstream Beamline Section-A and Supports Large SHMS/HMS Angles (Config -1) 1/26/2015 8

-Adjustment Assy Bellows and Gate Valve See Slides 5 & 6 Standoff- Dog Leg Aluminum SHMS Transition 1 ½ to 3 ½ SHMS Mount Assembly Standoff-Short Aluminum SHMS 6 SHMS Mount Assembly Standoff-Long Aluminum Horizontal Support Weldment Bolted to Steel Support and Target Adjustment Plate SHMS Downstream Beamline Section-A and Supports 1/26/2015 9 Large SHMS/HMS Angles (Config -1) Dog Leg Support-2 Possibly steel due to future side loading from Shielding

Target Center 0.00 Scattering Chamber Window Flange 29.126 3.288 Bellows 2.260 Gate Valve 1-1/2 Aluminum Pipe 81.575 SHMS Transition 3 1/2 Aluminum Pipe 1.3 Scatter Angle 6 Aluminum Pipe Extending to Section-B SHMS Downstream Beamline Section-A View illustrating diameters and 1.3 Scatter Angle Large SHMS/HMS Angles (Config -1) 1/26/2015 10

SHMS Downstream Beamline Section-A and Supports Large SHMS/ Min HMS Angle (Config -2) 1/26/2015 11

-Adjustment Assy Bellows and Gate Valve See Slide 5 & 6 Standoff- Dog Leg Aluminum SHMS Transition 1 ½ to 2 SHMS Mount Assembly Standoff-Short Aluminum SHMS 3 SHMS Mount Assembly Standoff-Long Aluminum Horizontal Support Weldment Bolted to Steel Support and Target Adjustment Plate SHMS Downstream Beamline Section-A and Supports Large SHMS/HMS Min Angle (Config -2) Dog Leg Support-2 Possibly steel due to future side loading from Shielding 1/26/2015 12

Target Center 0.00 Scattering Chamber Window Flange 29.126 3.288 Bellows 2.260 Gate Valve 1-1/2 Aluminum Pipe 81.575 SHMS Transition 2 Aluminum Pipe 1.3 Scatter Angle Outside Beampipe SHMS Downstream Beamline Section-A View illustrating diameters and 1.3 Scatter Angle Large SHMS/HMS Min Angle (Config -2) 3 Aluminum Pipe Extending to Section-B 1/26/2015 13

SHMS Downstream Beamline Section-B and Supports 1/26/2015 14

10 (Existing) 67503-00096 12 10 Support Mount 12 Support Mount seals are to be Metal O-rings Dog Leg Support-2 Possibly steel due to future side loading from Shielding SHMS Downstream Beamline Section-B s and Supports Typical for Configurations 1 and 2 DS Beam Line Support (Existing) 67100-56853 1/26/2015 15

10 Aluminum (Existing) 12 Aluminum (New) 1.3 Scatter Angle SHMS Downstream Beamline Section-B View illustrating diameters and 1.3 Scatter Angle 1/26/2015 16

SHMS Downstream Beamline Section-C and Supports 1/26/2015 17

24 67503-00096 18 67503-00095 24 Extension 67503-00037 24 Seal Ring 67503-00146 24 67229-56071 24 Dump Connection Or Exit Window Assy (In Work) seals are to be Metal O-rings SHMS Downstream Beamline Section-C Existing s and Supports DS Support Pole 67172-56139-01 Top Plate 67172-56139-03 24 Pipe Supports 67172-00038 1/26/2015 18

18 Aluminum (Existing) 24 Aluminum s (Existing) 24 Dump Connection Or Exit Window Assy (In Work) Need input clarification and requirements 1.3 Scatter Angle SHMS Downstream Beamline Section-C View illustrating diameters and 1.3 Scatter Angle 1/26/2015 19

24 Spool Can be fabricated to achieve required location of Exit Window or interface with new Dump Design 24 Bellows Similar in design as existing Bellows Do We Need?? Existing Spool and Window Assembly Design seals are to be Metal O-rings SHMS Downstream Beamline Section-C New Parts to interface with new Beam Dump or Simple Exit Window 1/26/2015 20

Reference Information And Existing Hardware 1/26/2015 21

DS Beam Line Support (Existing) 67100-56853 DS Support Pole 67172-56139-01 Top Plate 67172-56139-03 24 Pipe Supports 67172-00038 1/27/2015 22

1/26/2015 23

1/26/2015 24

1/26/2015 25

1/26/2015 26

1/26/2015 27