Laser Gas Analyzer LG2000. The Laser Technologies

Similar documents
Aurora. Moisture Measurement for Industrial Gases. GE Measurement & Control

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

FAS-W. Features. Applications. Automatic condensation hygrometer

PRODUCT CONFORMITY CERTIFICATE

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

HCL MONITORING. ICAC MARAMA WORKSHOP May 18-19th, Presented by: Ty Smith. CEMTEK

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

LFE OEM TCD - Thermal Conductivity Detector

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Model EXAxt AV550G. Averaging Oxygen Analyzer

Continuous Gas Analyzers, in-situ

GasSense NDIR User Manual

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Oxygen & Binary Gas Measurement and Analysis

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

EasyLine Continuous Gas Analyzers. So smart, they re simple

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

analytical bulk flow distance FLOW level pressure temperature industrial communication

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

THERMAL MASS FLOW MEASUREMENT FOR GASES

MATRIX-MG Series. Innovation with Integrity. Automated High-Performance Gas Analyzers FT-IR

Advance Optima -- High Performance Measurement Technology Oxygen Analyzer Module Magnos 16/17

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

FTC130 Transmitter. Operating Manual

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

CONTENTS OVERVIEWS PRODUCT INFORMATION

Micro Motion 3098 Gas Specific Gravity Meter

Laser in Situ Online Gas Analysis System. Application Guide. for the Petrochemical Industry

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Oxygen Flue Gas Analyzer BA 2000

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Advance Optima AO2000 Series Continuous gas analyzers Models AO2020, AO2040. Measurement made easy. Modular continuous gas analyzers

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

High-performance submersible pressure transmitter For level measurement Model LH-20

Laser Spectrometers for Online Moisture Measurement in Natural Gas. Ken Soleyn GE M&C

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

Continuous Gas Analyzers, in-situ

Level MEASUREMENT 1/2016

Automatic Isokinetic Sampler. ST5 Evo

Autocalibration Systems For In Situ Oxygen Analyzers

Visualize Nitrogen Gas Consumption

Flow metering in gases Introduction to COMBIMASS family

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Pressure Measurement Single-range transmitters for general applications

Analyze IT EL6010 Gas Analyzers in Category 2G

TH-1800-T TRX-700-CNG Converter

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Manual of SF6 Comprehensive Tester

Mass Flowmeters. Mass Flowmeters for Gases

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

C-Flow Coriolis Mass Flow Meters

Data Sheet 10/ EN July 2007

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

BUBBLER CONTROL SYSTEM

Ultrasonic level transmitter and indicator

LUGB Vortex Flowmeter

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Over 20,000 Strain Gage Target flowmeters installed since 1952.

High-performance submersible pressure transmitter For level measurement Model LH-20

Advance Optima AO2000 Series Continuous gas analyzers Models AO2020, AO2040. Measurement made easy. Modular continuous gas analyzers

MMS Mercury Monitoring System for Natural Gas

better measurement Simply a question of

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Features. Description

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Non-intrusive Natural Gas Flow Measurement

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

[Instruments for vacuum measurement, checking and adjustment] 3

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Your local gas generation partner. Precision series Modular gas generation solution for GC.

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

Real-time gas analysis and software for the management of bioprocessing

BUBBLER CONTROL SYSTEM

Instruction and Maintenance Manual

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

deltaflowc deltaflowc Venturi or Probe

Model 601CV. Mass Flow Controller. Product Features:

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

Zirconia Oxygen Analyzer Systems

High-performance submersible pressure transmitter For level measurement Model LH-10

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

SM8200. SO2/NO In Situ Multi-Gas Analyzer

WITT-GASETECHNIK GMBH & CO KG

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Transcription:

Laser Gas Analyzer LG2000 The Laser Technologies

LG 2000 Series Laser Gas Analyzer Utilizing proprietary technologies of Tunable Diode Laser Absorption Spectroscopy (TDLAS), the LG 2000 system to satisfy in-situ measurements with high accuracy, fast response, strong reliability and virtually maintenance free. The LG 2000 system is applica to almost all industrial process, especially well proven in harsh conditions in combination of high temperature, pressure, dust, corrosives and contaminants. Leveraging an installed base of over 8,000 units, the LG 2000 system has been extensively used for combustion and safety control, process optimization, energy recovery, scientific research as well as environmental monitoring. To date, these units have been employed in metallurgy, refinery, petrochemical, natural gas, power plant, waste incineration, cement and other situations where gas measurement is needed. Gas Detection Limit Measurement Range O 2 0.01%Vol 0-1%Vol, 0-100%Vol CO 0.6 ppm (0-60) ppm, (0-100)%Vol CO 2 1.5 ppm (0-150) ppm, (0-100)%Vol H 2 O 0.3 ppm (0-30) ppm, (0-100)%Vol H 2 S HF HCI 2 ppm 0.02 ppm 0.01 ppm (0-200) ppm, (0-30)%Vol (0-2) ppm, (0-10,000) ppm Vol (0-7) ppm, (0-8,000) ppm Vol Notes : Listed are detection limits specified for 1m optical path at 20 C, 1 bar abs. Dual Gas CO+CO 2, HCL+H 2 O are available for particular applications. Other gases and detailed measurement ranges may be available or customizable on request. HCN 0.3 ppm (0-30) ppm, (0-10,000) ppm Vol NH 3 0.4 ppm (0-40) ppm, (0-100) %Vol CH 4 10 ppm (0-200) ppm, (0-100) %Vol C 2 H 2 0.1 ppm (0-10) ppm, (0-100) %Vol C 2 H 4 0.6 ppm (0-60) ppm, (0-100) %Vol Configuration The transmitter portion of the LG 2000 system consists mainly of diode laser, laser driver and HMI modules, realizing diode laser driving, spectrum data processing and human-machine interface. The receiver unit of the analyzer is composed of a photoelectric sensor, signal processing and purge control modules, is capable of signal processing and anti-explosion control. Measuring Principle The laser beam from the transmitter unit passes across the stack or duct work and is absorbed by the measured gas. The attenuated light is then detected by the photoelectric sensor in the receiver unit, and the resulting signl is sent back to the transmitter unit and analyzed to yield gas concentration. Diode Laser Drive Circuit Data Analysis and Control Measuring Principle Diagram Data Acquisition

Technology Comparison Adaptability Measurement Response Time Acccuracy Item LG 2000 Laser System Conventional Online Analysis Applicable to high temperature, pressure, moisture, dust density and corrosion In-situ, continuous/real-time measurement; sample gas evacuation free Fast, only limited by electronics response, less than 1 sec. Average concentration along the optical path; no cross interference from other gas species, dust, and gas parameter fluctuations Application to constant temperature, pressure and dust free. With sample conditioning system, discontinuous measurement Slow, limited by gas sampling, transport, and instrument electronics response 20+ sec. Gas concentration at the tip of the sampling probe only, affected by gas influence and absortion, and leaked during gas sampling and transport; cross interference from other gas species, dust, and gas parameter fluctuations; gas information lost due to dissolution, absorption, and leakage. Reliability No moving parts, highly reliable Many moving parts, low reliability Calibration & Maintenance Calibration : <2 times/year Maintenance : <2 times/year Calibration : 2-3 times / month Maintenance : frequent Operation Costs No spare parts, only cost of electricity Lots of spare parts, around 20% of the equipment cost per year. Technical Principle No Cross Interference The laser spectrum features excellent monochromaticity with spectral width down to 0.001 nm, which is much narrower than spectral width of other light sources. Byutilizing the "Single-line" spectroscopy,awell-targeted laser spectrum can be sorted out to cover only the easuring gas without overlapping spectrum of all background gases. "Single-line spectrum" measurement No Effects from Dust, Moisture and Window Cotamination TDLAS gas analyzers use a laser spectral scanning technique. The unit periodically scans the gas under test with a modulation frenquency rangelarger than the gas absorption spectral line-width such that, within one scan period, there are two distinctive areas. Area I is uneffected by the gas absorption and gives Td, whereas Area II is effected and gives Tgd. The transmittance of the gas under test is then calculated accurately by Tg=Tgd/Td. The interference from dust and optical window contamination is, therefore, automatically screened out. Automatic Tempeature & Pressure Compensation When gas temperature and pressure under measurement changes, the width and height of the absorption waveform change, which effects the accuracy of the measurement. By having 4-20mA process temperature and pressure input the LG 2000 system automatically compensates for them with a proprietary algorithm to ensure measurement accuracy.

LG 2100 In-situ Features and Benefits In-situ, no gas sampling No cross interference Fast response less than one second Diverse optical length (0.5~20m) Reliable in all harsh conditions: high temperature & pressure, dust density, moisture and corrosion Online calibration, no zero drift Receiver Thousands of tailor-made solutions for various applications International ATEX certified Sender Application Areas Refinery & Petrochemical FCC Catalyst Regeneration SCR NH3 Injection Desulfurization Efficiency Explosive Process Gas Reactant Ratio Optimization Product Purity HCL, HF Emission Flue Gas Measurement Outlet of Process Heaters, Fractionators, Thermal Crackers, Utility Boilers and Incineratos Sulfur Recovery Metallurgy Combustion Control for Reheating Furnace, Heat treatment Furnace, Forging Furnace Converter Gas Recycle Blast Furnace Gas Coke Oven Gas Flue Gas of Sintering, Pelletizing Coal Injection Safety Control Electric Tar Precipitator (ETP) Safety Control CDQ Circulating Gas Gas Tank Safety Control Calorific Value Analysis Sulfur Recovery Thermal Power SCR NH3 Injection Desulfurization Efficiency Coal Injection Safety Control HCL, HF Emission Composition Sender Unit 4-20mA Input 4-20mA Output Relay Output RS485 Modbus RTU Instrument Flange Purging Gas 24V Power Supply Welding Flange Mounting Nut Receiver Unit Purging Gas Specification Repeatability : ± 1%F.S Linearity : ± 1%F.S Span drift : ± 1%F.S./6 months Response time : 1s(T90) Warm-up time : 15min Optical path length : 0.5-30m Process gas temperature : max. 1500 C Process gas pressure : 0.8 to 4 bar abs. Input & Outputs Analog outputs : 2 Outputs 4-20mA, max. load 750Ω, electrically isolated Relay outputs : 3 outputs 24V DC/1A Analog Inputs : 2 inputs 4-20mA, for gas temperature & pressure compensation Communications : RS485 (or Bluetooth, RS232 or GPRS) Operating Conditions Power supply : 24VDC (21-36VDC), or 90-240VAC Power consumption : Max. 20W Operating temperature : -30 C to +60 C Storage temperature : -40 C to +80 C Purge Gas : 0.3 to 0.8MPa nitrogen gas or instrument air Protection class : IP65 Approvals Laser class : class 1 conformant with IEC60825-1 CE certified : Conformant with 2004/108/EC ATEX(IECEx) certified : Ex d op is pxiic T5 Gb

LG 2200 Sampling Features and Benefits Fast response High accuracy, ppm level resolution No cross interference Reliable in all harsh conditions : high temperature & Pressure, dust density, moisture and corrosion Online calibration, no zero drift International ATEX certified Corrosion resistant / high temperature proof gas cell Application Areas Trace H 2 O in VCM Production Coal Injection Safety Control SCR NH 3 Injection in Coal-fueled Plants All other applications where in-situ doestn't fit due to high pressure or dust density, limitation of stack diameter or position. Composition Controller Specification Repeatability : ± 1%F.S Linearity : ± 1%F.S Span drift : ± 1%F.S./6 months Response time : 1s* Warm-up time : 15min Gas cell temperature : -30 C to +250 C Gas Cell Pressure : 0.5 to 3 bar abs *Gas flow > 1L/min, system response time : T90 20Ss. Gas Outlet Sender Probe 4~20mA Output Relay Output RS485 Gas Inlet Receiving Probe 220V Power Supply Input & Outputs Analog outputs : 2 Outputs 4-20mA, max. load 750Ω, electrically isolated Relay outputs : 3 output 24V DC/1A Communications : RS485 (or Bluetooth, RS232 or GPRS) Operating Conditions Power supply : 200-240VAC/48-63Hz Power consumption : 30W (no heat tracing) Operating temperature : -30 C to +60 C Storage temperature : -40 C to +80 C Purge Gas : 0.3MPa nitrogen gas or instrument air Protection class : IP65 Approvals TUV EC Conformity : 16030374 001 MCERT (Pending)

Dimension DN50/PN1.6 Flange DN50 Ball Valve 118 187 450 450 261 118 Sender Unit Purging Unit Receiver Unit Purging Inlet Ø8 to Receiver RS485 4-20mA Output Relay Output Ø8 24V Power Supply Ø8 to sender (4-20mA/Relay/RS485) G3/4 220 VAC Power Supply Ø8 190 20 ~2000 126 Ø100 Ø6 Sample Gas Ø100 Outlet Ø6 Inleet Ø6 Bont Technologies GmbH Salzstr.1 21335 Lüneburg www.bont-tech.com info@bont-tech.com