A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

Similar documents
FLOWSIC100 Flare Challenges in Ultrasonic Flare meter field installations. History of Evolution

Level MEASUREMENT 1/2016

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Gas Measurement Fundamentals Certification. Curriculum

Monitoring or Inspection

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Online data sheet FLOWSIC30 GAS FLOW METERS

THERMAL MASS FLOW MEASUREMENT FOR GASES

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Installation Effects on Ultrasonic Flow Meters for Liquids. Jan Drenthen - Krohne

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter. GE Sensing. Features. Applications

Diagnostics for Liquid Meters Do they only tell us what we already know? Terry Cousins - CEESI

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Instrumentation & Data Acquisition Systems

Over 20,000 Strain Gage Target flowmeters installed since 1952.

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

Micro Motion Coriolis Oil & Gas Metering Recommended Practices for Upstream Allocation

Flare Gas Measurement in B.C., Alberta, and Saskatchewan Using GE Ultrasonic Metering Technology

Shanghai AEAD Technology Co., Ltd Professional Manufacturer of Flow, Level, Pressure, Temperature

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Oil and Gas Custody Transfer

Improving distillation tower operation

Effect of noise in the performance of the transducers in an ultrasonic flow meter of natural gas

Flow metering in gases Introduction to COMBIMASS family

Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter

MEASUREMENT BEST PRACTICES FORIMPROVEDREFINERY SAFETY, AVAILABILITY & EFFICIENCY

Drilling Efficiency Utilizing Coriolis Flow Technology

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

deltaflowc deltaflowc Venturi or Probe

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Every things under control High-Integrity Pressure Protection System (HIPPS)

Measurement Technology

The American Society for Nondestructive Testing

The Discussion of this exercise covers the following points:

Towards ISO Koos van Helden, B.ASc. International Account Manager Eastern Hemisphere mailto:

analytical bulk flow distance FLOW level pressure temperature industrial communication

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Wedge Type Flow Meter Installation and Operation Manual

EXPERT SYSTEMS IN ULTRASONIC FLOW METERS

Calibrating and Monitoring MUSMs in Natural Gas Service

Increase Gas Production, Reduce Maintenance and Decrease Environmental Risks

JOSOP 603 flaring and venting Standard

Pro-V Multivariable Flowmeter

"BS An overview of updates to the previous ( 2009 ) edition. Andrew Wrath & BS7965 Working Group

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

SFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES:

Flowatch Multiphase Flow Meter

IT STARTS AT THE SOURCE - RE-CALIBRATING YOUR PLANT METERS

ACV-10 Automatic Control Valve

Liquid Level Measurement

NEW VERSAFLOW CORIOLIS

Becker* Products Below Ground Ball Valve Regulators

Ultrasonic Flowmeter USZ 08

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

Non-intrusive Natural Gas Flow Measurement

The Use of Ultrasonic Inspections at Elevated Temperature

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Visualize Nitrogen Gas Consumption

Products Solutions Services. Gas Flow Measurement

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

LPG DRIVER ATTENDED TRANSPORT LOADING

Remote. Measurement Assurance. Why CEESmaRT? significantly in measurement

The ERCB Directive 017 Overview

Specifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS)

SERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

Quick Installation Guide Doc nr.: C Date:

MIL-STD-883G METHOD

Micro Motion 3098 Gas Specific Gravity Meter

AMT-Ex Dewpoint Transmitter

Inspection of CANDU Reactor Pressure Tubes Using Ultrasonics

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

UsER manual for Watersens ph -REDOX

EXPERIMENTAL RESULTS OF GUIDED WAVE TRAVEL TIME TOMOGRAPHY

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Flare Gas Mass Flow Metering Innovations Promise More Economical Choices

Radar, Ultrasonic and RF Level Transmitters

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

Liquid level measurement using hydrostatic pressure and buoyancy

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Reduce Turnaround Duration by Eliminating H 2 S from Flare Gas Utilizing VaporLock Scrubber Technology

The Criticality of Cooling

Application Note AN-107

STANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK /J.02/0006-A4

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

75 Allen Street Lexington, MA Minute Model & Pricing Overview Guide

Digiquartz Water-Balanced Pressure Sensors for AUV, ROV, and other Moving Underwater Applications

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

Flowmeter Shootout Part II: Traditional Technologies

Transcription:

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility mass balance and compliance

1. What, When and Why? 2. Flare Measurement Challenges 3. Flare meter process selection 4. Installation best practices 5. Operation & Maintenance best practices 6. Questions

What, When and Why? Flare gas can come from a variety of sources and for different reasons. Chemical/Petrochemical Plants Refineries Gas Processing Plants Oil & Gas Production Storage LNG

What, When and Why? Flaring Situations Process unit upsets. Loss of compression. Over pressurization of relief valves. Start-up and shut-down. Blow Down. Loading & Unloading. Storage.

What, When and Why? Flaring is typically a safety measure to safely dispose of gas during upset and/or emergency conditions resulting from a loss of power or pressure control. It is performed to burn gas that cannot be stored or sold, and/or to burn waste gas that contains contaminants such as H2S.

FLARE GAS MEASUREMENT CHALLENGES Wide Gas Flow Velocity Range Large Pipe Diameters Changing gas composition Noise SNR Exposure to Erosion/Corrosion

Review considerations Selection process Pipe size, velocity calculations, Gas composition Installation Straight run, Orientation, Intrusive or not, Spool or hot tap, Noise sources Operation & Maintenance Inputs & Outputs, Process conditions, Erosion/Corrosion, Calibration

SELECTION PROCESS - PART 1 LARGE PIPE DIAMETERS Large Pipe Diameters can present their own set of issues:

SELECTION PROCESS - PART 1 LARGE PIPE DIAMETERS Large Pipe Diameters create similar and different issues: Larger pipes, especially with lower velocities, can result in non-ideal Re. Attenuating gases challenge the ability to maintain sufficient energy for signal acquisition. Large diameters also challenge the ability to provide sufficient straight runs.

SELECTION PROCESS - PART 2 WIDE RANGE OF FLUCTUATING VELOCITIES Standard operation of plant - small quantities of waste gas are burned, and some gases are used as a pilot gas to keep the BTU content at or above a federally regulated level. (Velocities are typically 0.1 to < 1.0 ft/sec). Low velocities can result in a non-axial, asymmetric flow regime where temperature-induced cross flows can contribute to a significant difference in travel times.

SELECTION PROCESS - PART 2 WIDE RANGE OF FLUCTUATING VELOCITIES In Emergency/Upset conditions - very large volumes of gas accumulate in a short period of time, and have to be disposed of immediately. (Velocities can be > 300 ft/sec). High velocities create noise in the form of turbulence, and in some cases can cause the signal to blow by the receiving transducer (signal loss).

SELECTION PROCESS - PART 2 The received signal power depends mainly on: Emitted sound pressure from the sender Signal Attenuation (signal damping in the gas and reflection losses) Filter characteristics of the receiver sensor Noise sources in the piping are: Signal to Noise Ratio (SNR) The flowing gas itself (turbulence creates noise) Valves, pressure regulators or any obstructions in the gas stream Powered equipment producing frequencies close to that of the ultrasonic sensors The most practical ways to increase the Signal to Noise ratio are: Maximize the emitted sound power from the sending transducer Optimize signal processing with the target to have a minimum limit value for the SNR, where the meter stops giving reliable results. Selecting a frequency range which is relatively insensitive to other noise (background) generated in the piping. FLUENTA 2013 www.fluenta.com 12

SELECTION PROCESS - PART 2 Robust Signal Processing Techniques t 12 t 12 t 21 Transit times measured with crosscorrelation and phase detection. The excitation signal is optimized for high and low velocities: Combination of Continuous Wave (CW) and Chirp is used for low velocities. Chirp signal (varying frequency, defined shape and duration) is used for high velocities. Using a continuous sine wave signal in combination with variable frequency ( Chirp ), improves low flow resolution and enables measurement through process noise generated from high velocity gas. Robust velocity measurements up to 120 m/s

SELECTION PROCESS - PART 3 CHANGING GAS COMPOSITIONS Multiple process units to a common flare header Densities/MWs can vary greatly How to accurately determine Density, MW, Mass? Unit1 Unit3 Unit5 Unit7 Unit2 Unit4 Unit6

SELECTION PROCESS - PART 3 CHANGING GAS COMPOSITIONS H2 can be problematic for USFMs. SoS =1000+ m/s: Large volumes can reduce the low flow sensitivity, and can create multiple reflections in small pipes. CO2 is very attenuating to USFMs. SoS ~ 267 m/s: Can reduce the upper flow limit by as much as 25%. N2 can affect the Mass flow result. SoS ~ 350 m/s: Has no BTU value, but will increase the apparent mass flow.

SELECTION PROCESS SUMMARY Pipe size Plan for worst case scenario but do NOT over do it! Velocity range Evaluate low, normal and high flow conditions and consider to manufacturers limitation Evaluate the signal processing method that better fits the application and installation requirements Gas composition Evaluate all potential scenarios for Gas composition Study impact of fluids that have adverse effect in measurements FLUENTA 2018 www.fluenta.com

Review considerations Selection process Pipe size, velocity calculations, Gas composition Installation Straight run, Orientation, Intrusive or not, Spool or hot tap, Noise sources Operation & Maintenance Inputs & Outputs, Process conditions, Erosion/Corrosion, Calibration

INSTALLATION - PART 1 Straight run Other ultrasonic's require 20/10 - In a 16 pipe that s 20 Feet of additional straight pipe! 10 x D 5 x D Preferred orientation: Horizontal installation on a horizontal line FLUENTA 2018 www.fluenta.com

INSTALLATION - PART 2 Orientation: horizontal, vertical, incline Avoid/Manage liquid accumulation, if any FLUENTA 2018 www.fluenta.com

INSTALLATION - PART 3 INTRUSIVE DESIGN Diagonal 45 o for low range Bias 90 o for high range probes are intrusive Multiple sets of sensors to cover the full flow range/turndown Exposure to erosion/corrosion Potential high velocity interference

INSTALLATION - PART 3 FULL PROFILE DESIGN Single set of non-intrusive sensors, using broadband (multifrequency), un-dampened transducers to measure the whole range probes are wetted but non-intrusive Diagonal 45 o

INSTALLATION - PART 4 SPOOL PIECE VS HOT TAP Spool piece is ideal for new facilities or planned Hot tap should be done between welding crew and flare meter vendor Tools for angle, measurements and pipe markings Follow all HSE applicable procedures and company policies FLUENTA 2018 www.fluenta.com

INSTALLATION SUMMARY Straight runs: significant installation deviations from standard recommended practice will impact accuracy Orientation: manage or avoid liquid buildup exposure as per manufacturer s recommendation Avoid intrusive or manage risk of high velocities that may cause erosion or corrosion issues Spool piece installation is recommended but hot tapping is a viable alternative when shutting in the line is not possible Isolate or keep distance from sources of noise FLUENTA 2018 www.fluenta.com

Review considerations Selection process Pipe size, velocity calculations, Gas composition Installation Straight run, Orientation, Intrusive or not, Spool or hot tap, Noise sources Operation & Maintenance Inputs & Outputs, Process conditions, Erosion/Corrosion, Calibration

Operation & Maintenance - PART 1 Inputs & Outputs Inputs Transducer tip distance (path) should be measured properly and given as an input P&T transmitters not only help standard volume calculations but also play a role in flow regime compensation (Reynolds number) Pressure & Temperature Transmitters should be ranged properly for the proper resolution Density from calculations or from analyzer? Weigh in accuracy of density versus measurement resolution Output variables Define critical variables to monitor Remote connection and protocols Analog signals (4-20mA) are very well established in the industry Digital interface offers the best results in terms of resolution and data available. Modbus, 4-20mA, HART, etc. FLUENTA 2018 www.fluenta.com

Operation & Maintenance - PART 2 PROCESS CONDITIONS Sensors are exposed to a variety of corrosive gases and liquids. Acid Gas, Liquid carry over Solids / particulates Sensors can become coated, even damaged Combined with high velocities creates an erosive atmosphere Periodical cleaning and inspection Material selection

Operation & Maintenance - PART 3 How to verify your meter is still reliable/accurate? Calibration The nature of flare service precludes the ability to calibrate in-situ. You could send the meter out to a calibration facility Costly NO UNPLANNED SHUTDOWNS!! No measurement while meter is being calibrated Lab conditions very seldom can replicate the field conditions (piping, velocity) Required accuracy is +/- 5% or better (non-custody transfer), so is the cost of a calibration justified? Calibration can reduce the turndown

Operation & Maintenance - PART 3 How to verify your meter is still reliable/accurate? Verification/Validation An on site calibration performed by most USFM manufacturers is really more of a verification. Zero Box - controls temperature and pressure, to verify a zero. Transducers are removed from the line and placed in the zero box. Insertion depths are set so that path lengths remain constant. Verification can be performed on-site by analyzing a variety of diagnostics such as signal quality, amplitude, gain, signal to noise ratio and speed of sound.

OPERATION & MAINTENANCE SUMMARY Identify critical measurement inputs and outputs and define the right communication protocol for your facility Provide initial input about process fluids under normal and upset conditions to improve material and sensor type selection (anticipate fluids that may affect measurements) Periodical verification (usually once a yr.) to check integrity of measurement system, communication and necessary adjustments based on process conditions changes All these aspects will ensure compliance with regulations and better measurement data management FLUENTA 2018 www.fluenta.com

ADVANCED ULTRASONIC TECHNOLOGY FOOD FOR THOUGHT API has been conducting Ultrasonic Flare Flow Meter testing Accuracy/Performance Velocity Limitations Current acceptable accuracy +/- 5% Royalty/Lease Payments Higher accuracy requirements? Additional paths? What will the next generation of a Flare Flow Meter look like?

Thank you! Any Question? FLUENTA 2013 www.fluenta.com