DEEPSEA. SeaLite Lumos POWER & LIGHT. Operator s Manual Ruffin Road San Diego, CA USA.

Similar documents
DEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA

DEEPSEA. Sealite Sphere 6500 POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA

DEEPSEA. Sealite Sphere POWER & LIGHT. Operator s Manual 3150, 5150, 6150, Original Instruction Ruffin Road San Diego, CA USA

DEEPSEA. LED Micro SeaCam POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA

DEEPSEA. Sealite Sphere POWER & LIGHT. Operator s Manual 3100, 5100, 5500, 6100, Original Instruction

DEEPSEA. Power & Light. Micro SeaLaser. Operator s Manual Ruffin Road San Diego, CA USA T: (858) F: (858)

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Norrsken Family Booklet

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Saline C 6.0 Junction Box

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

453 Series Steam Heated Vaporizing Regulator

MODEL 100 NITROGEN INFLATION CART

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

Installation, Operation and Maintenance Manual

Vevazz. Operation Manual. Vevazz, LLC Rancho California Road. Suite Temecula, CA Phone: (773) Fax: (888)

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

Gemini Owner s Manual

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

BGA244 Binary Gas Analyzer

Geotech 1.66 Reclaimer

AUTO PUMP STATUS CENTER

6 digital caliper with case

For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)

SMART Oxygen Analyzer. User Manual

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

Permanent Roof Anchors

4-in-1 Professional Inflator Kit

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

4 and 8 Station PDS Control Installation & Operators Manual

Ocean Technology Systems ComBox

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

AA100 Acoustic Actuator

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

HAI UPB Wall Switch and Auxiliary Switch Installation and Operating Instructions

ASDX Series Silicon Pressure Sensors

User s Guide Temperature Sensor Converter TSC-599

92831 TEL: (714) FAX:

Model ASSEMBLY and OPERATING INSTRUCTIONS

Cylinder Tilt Saddle Instruction Manual

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

Portable Compressed CO 2 Regulator

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

92831 TEL: (714) FAX:

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Portable oxygen concentrator

Pressure Relief Valve Instruction Manual

In Vivo Scientific, LLC INSTRUCTION MANUAL

GasSense NDIR User Manual

SPECIFICATIONS APCEPH1

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

Operation Manual. O2 Quickstick. Oxygen Analyzer

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

Eastwood Versa-Cut Plasma Cutting System

PPS PORTABLE POWER SUPPLY

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Geotech 3.5 Reclaimer Installation and Operation Manual

8675/8677/8678 OWNER S MANUAL

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

SP-110 Autopilot OPERATION

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

Geotech 1.66 Reclaimer Installation and Operation Manual

210 Series Transmitter with External Electrochemical Sensor

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

FC100 / FC101 FlowCom Register

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

OPERATOR'S & PARTS MANUAL

Mini Pod Press. #78H-M2 Mini Pod Press Manual-R1

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

COMPACT METAL bender 99826

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

User Manual. ECC-Opto-Gas. Release Electrochemical test cell EL-CELL GmbH

700 SERIES BMS II BUBBLER MONITORING SYSTEM

GAS FUEL VALVE FORM AGV5 OM 8-03

USER S GUIDE AUTOTUNE SERIES HIGH INTENSITY ULTRASONIC PROCESSOR Watt Model TABLE OF CONTENTS

Price Schedule # Effective: MAy 5, 2014

Offset head dual chuck

A3 / A4 / A5 / A6 / A8 Spherical Ionization Chambers REF / / / / User Manual

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

! Warning, refer to accompanying documents.

Research Grade Blood Pressure Transducer User's Manual

FLANGED TWO-PIECE BALL VALVES

SMART Carbon Monoxide Analyzer. User Manual

Transcription:

SeaLite Lumos DEEPSEA POWER & LIGHT T: (858) 576-1261 F: (858) 576-0219 4033 Ruffin Road San Diego, CA 92123-1817 USA www.deepsea.com sales@deepsea.com REV 08/27/18

Optical Specifications Specification Overview SLL-1000 Typical Lumen Output 3,000 Color Day Light White 5000K - 6500K Contact Sales for Color Options Beam Angle (HPFW) Flood: 85º or Spot: 32º Environmental Specifications Depth Rating 6,000 m Operational Temperature -10º C to 40º C [14º F to 104º F] Electrical Specifications Voltage Current 90~270 VAC, 50/60Hz 100~350 VDC 0.27A @ 120 VAC 0.13A @ 240 VAC SLL-2000 10~36 VDC 1.10A @ 24 VDC 2.65A @ 10 VDC Standard Connectors 3 5 4 2 1 1 2 3 MCBH3MP (High Voltage AC/DC) 1 = Hot (DC +) 2 = Neutral (DC -) 3 = Chassis MCBH5MP (Low Voltage DC) 1 = DC+ 2 = DC- 3 = Chassis 4 = Not Used 5= 0-5 V DC Control (0-5V DC Control referenced to Pin 2) *Other connector options are available upon request. Power 32.0W max 26.5W max Dimming Mechanical Specifications Housing Port AC phase control (TRIAC) variable voltage (VARIAC) Titanium Sapphire 0~5 VDC Dimensions 2.47 62.6 1.87 47.5 Outer Diameter Overall Length (Without Connector) Weight in Air Weight in Water Connector Default 47.5 mm [1.87 in.] 154.3 mm [6.08 in] 710 g [1.56 lbs]` 400 g [0.88 lbs]` SEACON MCBHMP Contact sales for more options. 6.08 154.3 1.69 42.9 7.35 186.7 1.85 47 2.40 60.9 1.59 40.3.59 15 1 Titanium Housing, Universal Driver, Spot Reflector model. 1.00 25.4 1.00 25.4 4X 1/4-20 UNC OR 4X M6 x 1.0 [inch] mm 2 * Specifications subject to change without notice.

Table of Contents Specification Overview 2 Table of Contents 3 Safety Symbols 4 General Notes and Warnings 4 Pre Dive Inspection 4 Post Dive Inspection 4-5 Troubleshooting 5 Flooded Light Repair 5 Limited Warranty 5 RMA Procedure for Repair 5 Appendix A: Dimming Response Curve 6 Appendix B: Driver Efficiency 9 Appendix C: LVDC Step Response Curve 11 Appendix D: Beam Patterns 14 3

Safety Symbol In this operator s manual and on the product, safety symbols are used to communicate important safety information. This section is provided to improve understanding of these symbols. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER! WARNING CAUTION NOTICE DANGER indicates a hazardous situation which, if not avoided, could result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in damage to the product or bodily harm. CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE indicates information that relates to the protection of property. This symbol means read the operator s manual carefully before using the equipment. The operator s manual contains important information on the safe and proper operation of the equipment. This symbol means always wear safety glasses with side shields or goggles when handling or using this equipment to reduce the risk of eye injury. This symbol indicates the risk of electrical shock. General Notes and Warnings You may run your in air. As the light heats up you will notice that the output will diminish. This is normal, and the light will return to full brightness once it is submerged and allowed to cool down. DANGER When the is operated in air, the body may reach temperatures in excess of 65 C. These temperatures may be enough to cause burns if the light is handled without protective clothing. Do not operate any high voltage electrical equipment in or around water without using a Ground Fault Interrupt circuit (GFI) and an isolation transformer, especially when divers are in the water. WARNING Do not clean any part of the light head with any type of alcohol. There should be no reason to ever open the body of your light. There are no user serviceable parts inside your new underwater light. Your SeaLite Lumos was thoroughly pressure tested prior to leaving the factory to confirm the integrity of the complete assembly. Opening the housing may cause potential problems when resealing. Pre and Post Dive Inspection Check to make sure that the rear bulkhead connector is secure before deployment. Check the following areas for previous damage, wear or corrosion: rear bulkhead connector, power cable, front window. Rinse your in fresh water after use in saltwater. DANGER After each deployment, carefully check to make sure the light is operational and has not flooded. If it gets flooded, upon surfacing, the light can become internally pressurized, which may be potentially dangerous. Additionally, if the power remains on when the light has partially flooded, it is possible for electrolytic generation of an explosive mixture of hydrogen and oxygen gases. If a light appears flooded upon removal from the water, it should be treated as potentially dangerous. Point the light away from persons and valuable equipment and make sure that the power is disconnected. See the Flooded Light Repair procedure for more information. 4

Troubleshooting If the light stops working while underwater assume that it has been flooded. See Flooded Light Repair procedure below. Once it has been determined that the light is not flooded, or if it does not turn on during pre-deployment checks, check the input power cable/inline connector to make sure that correct voltage is being supplied, and that the correct pinout is being used. See page 2 of this manual for electrical specs and connector pin assignments. If the light still does not work, return it to DSPL using the RMA Procedure for Repair below. Flooded Light Repair If the light stops working while underwater, assume that it has been flooded. When working on a potentially flooded light, it is important to use appropriate personal protective equipment to include, at a minimum, eye and hand protection. 1. Place the light face down on a table making sure that the connector side is facing up. 2. Slowly unscrew the connector/socket assembly to allow any internal pressure to be equalized. 3. Once it is determined that the light is not internally pressurized, it is recommended that the light be returned to DeepSea Power & Light (DSPL) for evaluation and repair using the RMA Procedure. RMA Procedure for Repair Should it be necessary to return your light to the factory, follow the procedure for the Flooded Light Repair above, leaving the connector partially unscrewed. For warranty and non-warranty repairs please contact DeepSea Power & Light for a RMA number prior to returning your item. Please have your light model number, serial number and any other pertinent information along with a description of the problem, on hand when you call, or include them in a fax or e-mail. When shipping your item, be sure that the freight is pre-paid (CODs will not be accepted) and that the RMA number is clearly printed on the outside of the box. Tel: (858) 576-1261 Fax: 858-576-0219 e-mail: RMA@deepsea.com Limited Warranty Seller warrants that the goods (except internal electronic components) sold under this contract will be free from defect in material and workmanship for a period of one year from the date of shipment from the factory, if they have been properly used. Internal electronic components are warranted for 90 days from the date of shipment from the factory, if they have been properly used. This warranty will be limited to the repair or replacement of parts and the necessary labor and services required to repair the goods. IT IS EXPRESS LY AGREED THAT THIS WARRANTY WILL BE IN LIEU OF ALL WARRANTIES OF FITNESS AND IN LIEU OF THE WARRANTY OF MERCHANTABILITY. This warranty is the exclusive and only warranty to pass with the goods under this contract. No agent, employee, or representative of the Seller has any authority to bind Seller to any information, representation, or warranty concerning the goods sold under this contract, and unless an affirmation, representation, or warranty made by an agent, employee, or representative is specifically included within this contract, it will not be enforceable by Buyer. If notice of defect is given to DeepSea Power & Light LLC within such 90 day or one year warranty period, the sole obligation of DeepSea Power & Light LLC shall be to furnish new or repaired parts free of charge in exchange for parts which have been proved defective and does not include any other costs such as the cost of removal of the defective part, installation, labor, or consequential damages of any kind, the exclusive remedy being to require DeepSea Power & Light LLC to furnish such new parts. Under no circumstances shall the Buyer be entitled to recover any incidental damages as that term is defined in Commercial Code 2715. All shipments should be sent to the address below: DeepSea Power & Light Attn: RMA #### 4033 Ruffin Road San Diego, CA 92123-1817 U.S.A www.deepsea.com sales@deepsea.com 4033 Ruffin Road San Diego, CA 92123-1817 USA T: (800) 487-3775 F: (858) 576-0219 5

Appendix A Dimming Response Curves 6

SeaLite Lumos 1000 Phase Cut Dimming Response 100% 80% % Output 60% 40% 20% 0% 0 20 40 60 80 100 120 140 160 180 Input Phase Angle SLL-1000 120VAC 60Hz SLL-1000 240VAC 50Hz SeaLite Lumos 1000 Variable Voltage Dimming Response 100% 80% % Output 60% 40% 20% 0% 0V 20V 40V 60V 80V 100V 120V 140V 160V Input RMS Voltage SLL-1000 120VAC 60Hz SLL-1000 High Voltage DC 7

SeaLite Lumos 2000 Analog Dimming Response 100% 80% % Output 60% 40% 20% 0% 0.0V 1.0V 2.0V 3.0V 4.0V 5.0V 6.0V Dimming Input Voltage 8

Appendix B Driver Efficiency 9

SeaLite Lumos 1000 Efficiency 100% 80% Efficiency 60% 40% 20% 0% 60V 110V 160V 210V 260V 310V 360V Input RMS Voltage SLL-1000 VAC 60Hz SLL-1000 VAC 50Hz SLL-1000 DC SeaLite Lumos 2000 Efficiency 100% 3.5 3 80% 2.5 Efficiency 60% 40% 20% 2 1.5 1 0.5 Current (A) 0% 6V 12V 18V 24V 30V 36V Input DC Voltage 0 Efficiency Input Current 10

Appendix C Low-Voltage DC Step Response Curve 11

SLL-2000 DIM Input Step Response Characteristics 5V 100% 90% Control Pulse (V) 4V 3V 2V 1V 80% 70% 60% 50% 40% 30% 20% 10% % Output 0V 0% -10 0 10 20 30 40 50 Time (ms) Trigger % Output 12

DIM Input Pulse Response: Rise Time SLL-2000 LVDC DIM Input Pulse Response: Fall Time SLL-2000 LVDC 13

Appendix D Beam Patterns 14

Lux Radial Lux Intensity Comparison -90-85 -80 6000-75 -70-65 -60-55 5000-50 -45 4000-40 -35 90.0 80.0 70.0 60.0 50.0 Angular Distribution 3000 2000 1000 0-30 -25-20 -15-10 -5 0 5 10 15 20 Degrees 40.0 30.0 20.0 10.0 0.0-10.0-20.0-30.0 25-40.0 30 35-50.0 90 85 80 75 70 65 60 55 50 45 40-60.0-70.0-80.0-90.0 0% 25% 50% 75% 100% % Output Lumens: Peak Lux: FWHP Angle: SeaLite Lumos Flood SLL-2000-DW-F-A05 2607 1550 87 Lumens: Peak Lux: FWHP Angle: SeaLite Lumos Spot SLL-1000-DW-S-PV 1831 5160 34 NOTE: Beam pattern data for a representative sample of the indicated product configuration only. 15