Encore PE 50-lb Feed Hopper

Similar documents
NHR-X-X Encore Feed Hoppers

NHR Powder Feed Hopper

Standard and Low-Flow Metric Powder Feed Pumps

Tribomatic II Powder Pump

Metric Porcelain Enamel Powder Pump

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 2300 Units

Operating Instructions Models and Hydrostatic Test Pumps

K Page 1 of 48 Air Intake - Pg. 17

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps

Safety Powder Spray Systems

SIMPLAIR PIPING TOOL. JXT Company

Color Change Procedures ColorMax Powder Booth with Spectrum II Feed Center and Prodigy HDLV Powder Transfer System A04

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

Ultra Concentrate Dispensing System

VERTICAL BLADDER TANK

Squeegee Unit for MRS Multi-Recovery System

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

CO2 Tank Conversion Kit P.N , P.N , and P.N

Backboard and Rim Owners Manual

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

BRONZE BUSHING REPLACEMENT PROCEDURE DN345 & NL450C

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Operating Instructions Model and Hydrostatic Test Pump

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

HORIZONTAL BLADDER TANK

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS

SERVICE KITS SPECIFICATIONS GENERAL DESCRIPTION. y Use only genuine ARO replacement parts to assure compatible. RM051S-XXX-XX Single Post Lift / Ram

Universal Elevator Mount Owners Manual Customer Service Center N53 W24700 South Corporate Circle Sussex, WI U.S.A.

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Installation, Operation and Maintenance Manual for Back Pressure Regulator

RM051S-XXX-XX SINGLE POST LIFT / RAM

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Sanitizer Parts. Sanitizer Parts. Replacement Parts for Sanitizers

Instructions for using TSI Model mm or 8025-CEN Fit Test Adapter Kit

Pneumatic spool valve islands

30cc STRING TRIMMERS 30cc BRUSHCUTTERS REPAIR SHEET MODEL NUMBERS RY30020B, RY30040B, RY30060B

First the grid is assembled: bend it round so that the fixing hooks go from outside to inside.

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual

2.5 & 5.0 GALLON PRESSURE TANKS

TWO POST RAM PACKAGE 55 GALLON

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Chapter 9 Accessories

OPERATION MANUAL obl1 OPERATION MANUAL

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

CM MBC & CM MBC PARTS LIST

MID-CUT AND FRONT CUT UNITS

Booster Pump PB4-60 Replacement Kits

Poppetted Coaxial Drop Tube Assembly for use with Auto Limiter II. Installation Instructions

1805 Series Relief Valves

CS150 CAP STAPLER OWNER S MANUAL

WELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

11. Spare Parts. applications since applications since

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

14. Exploded View. Page 68

Model PSI Compressor with 3-Gallon Air Tank 12VDC

RM052S-XXX-XX TWO POST LIFT / RAM

PRODUCT OPERATING MANUAL

Model MTB-ASME Vertical Bladder Tanks

Installing ASI Umbilical Delivery Systems

Model MTB-ASME Vertical Bladder Tanks

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

600 o F High Temperature Aging Cell Instruction Manual

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Carter Option X Valve connector assembly. Maintenance manual

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

CP10 Sensor Installation and Maintenance Instructions

D Carriage Design (ALS)

Instruction Manual Updated 7/26/2011 Ver. 2.2

KEG PUMP. Range of Electric Keg Pumps

Hodge Clemco Ltd. SG-300 Suction Gun. Owner s Manual. Hodge Clemco Ltd

Agilent 1290 Infinity Pump Head Maintenance

Dual Electronic Basketball System Owners Manual

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

ABRASIVE REGULATOR II

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

Installing a Christie One Mount/Christie One Mount Plus

INSTRUCTIONS 360 Y-DROP HAGIE STS 2015

GEN20AD-GEN20AL-GEN18AN

Operating Instructions Models and Hydrostatic Test Pumps

Air Intake Snorkel Kit

ABRASIVE REGULATOR II

SERVICE KITS SPECIFICATIONS GENERAL DESCRIPTION. RM052S-XXX-XX Two Post Lift / Ram

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

American Meter Co. Five-Year Limited Warranty Industrial Regulators

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Transcription:

Instruction Sheet P/N 160429-01 Encore PE 50-lb Feed Hopper WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Description This instruction sheet provides specifications; installation and operation instructions; and parts lists for the. This hopper is used primarily with Nordson Mobile or Rail Mount Manual Powder PE Spray Systems. The hopper is shipped fully assembled, with an Encore PE pump adapter and pickup tube assembly, vent tube, and hopper fill plug. Specifications Specification Value Powder Capacity: 2 kg (50 lb) *Pump Knockouts: 2 *Pump Adapters Included: 1 Dimensions Height: 62 cm (24.5 in.) Diameter: 40.00 cm (15.75 in.) Weight (Empty): 9.5 kg (21 lb) Weight 2.5 kg (71 lb) (Full to Capacity): Fluidizing Pressure: 0.1 0.6 bar (2 8 psi) Fluidizing Air Tubing: *Pumps and additional adapters must be ordered separately. 10-mm OD

2 Installation Basic See Figure 1. 1. Make sure the fluidizing drum (6) and cover (2) are securely clamped to the body (), and that all gaskets are undamaged and sealing properly. 2. Connect 10-mm flexible air tubing to the fitting labeled with the fitting on the rear of the controller labeled with the hopper fluidizing icon ( ). Connect the opposite end of the tubing to the fluidizing air connector (5). WARNING: All electrically conductive equipment in the spray area must be grounded. Ungrounded or poorly grounded equipment can store an electrostatic charge which can give personnel a severe shock or arc and cause a fire or explosion.. For stand-alone hoppers, connect the ground wire shipped with the hopper to the ground stud (4). Connect the spring clip to a true earth ground. For hoppers on a mobile powder system dolly, connect the dolly ground wire to the ground stud (4). 4. Make sure the O-rings are installed correctly in the pump or adapter grooves. Install the pump on or in the adapter with a slight twisting motion. 5. Connect the flexible vent hose shipped with the hopper to the vent hose adapter (1). Secure the hose to the adapter with a hose clamp. Connect the other end of the hose to the booth powder collector to prevent vented powder from contaminating the room air. Installing Additional Pumps If you wish to install an additional pump, you must order a pump adapter and pickup tube for it. Remove the plug from the cover and install the adapter, pickup tube, and pump.

1 2 4 6 5 Figure 1 NHR-2-50 Encore PE Feed Hopper 1. Vent hose adapter 2. Cover. Body 4. Ground stud 5. Fluidizing air connector 6. Fluidizing drum Operation WARNING: Wear an approved respirator, protective clothing, and gloves when handling powder. Avoid skin contact with powder coatings, or breathing powder particles. 1. Fill the hopper half full of powder, to provide room for expansion as the powder is fluidized. Do not overfill. Overfilling may prevent powder from being fully fluidized, and affect coating performance. 2. Turn on the fluidizing air, and adjust the regulator until the powder is gently boiling. The air mixed with the powder will cause it to increase in volume. Fluidize the powder for five or ten minutes to make sure it is evenly fluidized and no clumps are left before spraying. Maintenance Periodically, empty the hopper and clean the interior. Clean the fluidizing plate and inspect it for signs of air contamination. If the plate is discolored and appears to be contaminated, replace it. Check your air supply and correct any contamination problems.

4 Parts To order parts, call the Nordson Industrial Coating Systems Customer Service Center at (800) 4-919 or your local Nordson representative. See Figure 2. Item Part Description Quantity Note 1604292 HOPPER ASSEMBLY, NHR Encore PE, 50 lb., packaged 1 1 1008082 HOSE, flexible, m (10 ft) 1 2 970966 CLAMP, hose 1 107022 PLATE, fluidizing 1 4 107024 GASKET, U-channel 1 5 107451 DRUM, fluidizing 1 A 6 1107948 BODY, hopper, packaged, 50 lb 1 7 981170 SCREW, truss, unslotted, 10 2 x 0.75 in. 8 8 984120 NUT, hex, small pattern, 10 2 8 9 164064 LATCH, hopper, curve base 4 10 107452 COVER, hopper, NHR-2, assy, packaged 1 B 11 1602284 MOUNT ASSY, pump, 18 in. 1 12 942161 O-RING, silicone, 1.125 x 1.75 x 0.125 in. 1 1 1602261 MOUNT, pump 1 14 09474 TUBE, pickup, 0.490-in. ID x 18 in., ⅜ NPS 1 15 9961 LOCKNUT, conduit, / 4 -in. NPS 1 16 14242 Plug 1 NS 14575 WIRE, ground 1 NOTE A: Refer to Fluidizing Drum on page 7 for a parts breakdown. B: Refer to Hopper Cover on page 6 for a parts breakdown. NS: Not Shown

5 1 2 16 1 12 10 15 11 14 7 8 9 6 4 5 Figure 2 Hopper Parts

6 Hopper Cover Item Part Description Quantity Note 107452 COVER, hopper, NHR-2 assy, packaged 1 1 1008081 NUT, conduit, 1.25 in. 1 2 1008080 GASKET, vent stack 1 1008079 FITTING, pvc, 1 1 / 4 in., male adapter 1 4 1070199 PLUG, hopper fill, NHR 1 NS 107459 GASKET COVER SERVICE KIT 1 NS: Not Shown 2 4 1 Figure Hopper Cover

7 Fluidizing Drum Item Part Description Quantity Note 107451 DRUM, fluidizing 1 1 107455 ELBOW, male, / 8 -in. RPT x 10-mm tube 1 2 984702 NUT, hex, M5, brass 2 98401 LOCK WASHER, split, M5, steel, zinc 11 4 98021 WASHER, flat, 0.20 x 0.405 x 0.040 in., brass 1 5 982126 SCREW, pan head, M5 x 25, brass 1 6 240674 TAG, ground 1 7 164064 LATCH, hopper, curve base 4 8 982000 SCREW, pan head, M5 x 10, zinc 8 9 9812 WASHER, flat, 0.219 x 0.500 x 0.049 in. 7 10 984706 NUT, hex, M5, steel, zinc 8 9 10 5 8 7 6 1 2 4 2 Figure 4 NHR Fluidizing Drum

8 Issued 7/1 Original copyright date 201. Encore, Nordson, and the Nordson logo are registered trademarks of Nordson Corporation.