STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION 333 West Seventh Avenue Anchorage, Alaska 99501

Similar documents
1. UPDATE 12/12/2014: What wells are regulated under the MIA Program? Must they be drilled, stimulated, and completed? Must they be in production?

Blowout during Workover Operation A case study Narration by: Tarsem Singh & Arvind Jain, OISD

RULES OF THE OIL AND GAS PROGRAM DIVISION OF WATER RESOURCES CHAPTER DRILLING WELLS TABLE OF CONTENTS

Investigation of Explosion and Fire at Prudhoe Bay Well A-22 North Slope, Alaska August 16, 2002

1. The well has been shut in on a kick and the kill operation has not started.

Texas Administrative Code

DEPARTMENT OF ENVIRONMENTAL PROTECTION Office of Oil and Gas Management

Success Paths: A Risk Informed Approach to Oil & Gas Well Control

Investigation of Loss of Well Control Eugene Island Block 277 OCS-G Well A-2 Off the Louisiana Coast July 6, 2001

Hard or Soft Shut-in : Which is the Best Approach?

Protecting People and the Environment during Stimulation Treatments in Offshore Settings

TAQA North Ltd. Well Blowout W4M June 8, 2009

IWCF Equipment Sample Questions (Combination of Surface and Subsea Stack)

Module No. # 01 Lecture No. # 6.2 HAZOP (continued)

BUCCANEER ALASKA OPERATIONS, LLC. BUCCANEER ALASKA OPERATIONS, LLC Cook Inlet Exploratory Drilling Program. Community Outreach: KPB Assembly

Well Control Drill Guide Example Only. Drill Guide is the list of drills, questions and attributes that are in DrillPad.

The enforcement staff believes a hearing panel could enter a show-cause order pursuant to Bylaw regarding involvement in Allegation No. 1.

AUSTRALIA ARGENTINA CANADA EGYPT NORTH SEA U.S. CENTRAL U.S. GULF. SEMS HAZARD ANALYSIS TRAINING September 29, 2011

COGCC OPERATOR GUIDANCE MECHANICAL INTEGRITY TEST GUIDANCE: PRACTICES AND PROCEDURES

Railroad Commission of Texas. Chairman Barry T. Smitherman Commissioner David Porter Commissioner Christi Craddick

Perforating Options Currently Available in Horizontal Shale Oil and Gas Wells. Kerry Daly, Global BD Manager- DST TCP

"Sharing To Be Better. Influx through failed cement in shoetrack during completion operations

Deepwater Horizon Incident Internal Investigation

CHE Well Testing Package/Service:

Appendix K Appendix K

Mecklenburg County Health Ordinance Rules Governing Residential Swimming Pools

SPE MS Well Collision Avoidance Management and Principles

7/27/2011. How Things Can Go Wrong In The Drilling Of Oil / Gas Wells

Wednesday, March 6, 2013 Houston, TX. 2:30 4:00 p.m. CLOSING SESSION BLOWOUT! A NIGHTMARE IN THE OIL PATCH

Subsea Safety Systems

Disposal/Injection Well Pressure Test Report (H-5)

Chapter 4 Key Findings. 4 Key Findings

SUPPLEMENT Well Control for Drilling Operations Workover & Completion for Supervisors Core Curriculum and Related Learning Objectives

W I L D W E L L C O N T R O L SHUT-IN PROCEDURES

International Well Control Forum. Well Intervention Pressure Control Level 2 Syllabus July 2015 Version 7.0

Performance and Value of the invision System : Offshore in Coiled Tubing Operations

Dilution-Based Dual Gradient Well Control. Presented at the 2011 IADC Dual Gradient Workshop, 5 May 2011 by Paul Boudreau, Dual Gradient Systems LLC

SUPPLEMENT Well Control for Drilling Operations Workover & Completion for Drillers Core Curriculum and Related Learning Objectives

August 21, Deepwater MPD / PMCD

W I L D W E L L C O N T R O L PRESSURE BASICS AND CONCEPTS

Pressure Relief Device Investigation Testing Lessons Learned

EASTERN MICHIGAN UNIVERSITY PUBLIC INFRACTIONS REPORT NOVEMBER 8, 2012

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

EXAMINER S REPORT AND RECOMMENDATION STATEMENT OF THE CASE

Every things under control High-Integrity Pressure Protection System (HIPPS)

SOP GEN-007X Crane and Winch Operations

Study Guide IADC WellSharp Driller and Supervisor

Commentary on the book by Andrew Hopkins. By Graham Dalzell

Talk 2 Tree & Wellhead Valve Testing Leak Rate Acceptance. Talk 3 DHSV Control Line hydrocarbon Ingress measurement & acceptability

Comments and Requests for Additional Information. Regarding

2017 LGA 191/192 & 195 Pipeline Safety Conference

Why Do Not Disturb Is a Safety Message for Well Integrity

PETITION OF SHELL OIL COMPANY TO MAKE PERMANENT THE PRESENT SPECIAL FIELD RULES FOR THE SOUTHWEST PINEY

Colorado Oil and Gas Conservation Commission

APPEALS COMMITTEE UPHOLDS DECISION FOR BALL STATE UNIVERSITY FORMER COACH

IWCF Equipment Sample Questions (Surface Stack)

MSC Guidelines for the Review of Vapor Control Systems Procedure Number: C1-46 Revision Date: March 30, 2012

Restoring Fluid Flow in Tubing Strings

NORSOK STANDARD SYSTEM REQUIREMENTS BOP, DIVERTER AND DRILLING RISER SYSTEM (SYSTEM NO.: 12-30, 12-40)

Environmental Appeal Board

INTERPRETATION NOTE ISSUED UNDER THE PETROLEUM DRILLING REGULATIONS (CNR 1150/96)

Commonwealth of Kentucky Court of Appeals

Case studies from classes led by Dr. Ron Fulbright, University of South Carolina Upstate. IMPROVED BLOWOUT PREVENTER

POLMAK SONDAJ SANAYII A.S. HEALTH, SAFETY, AND ENVIRONMENTAL POLICY

LOCKOUT SYSTEM AND POLICIES

IACS History File + TB

MSC Guidelines for Review of Vapor Control Systems Procedure Number: C1-46 Revision Date: 01/08/2018

A LIFE OF THE WELL ARTIFICIAL LIFT STRATEGY FOR UNCONVENTIONAL WELLS

HYDROSTATIC LEAK TEST PROCEDURE

APPENDIX A1 - Drilling and completion work programme

FOR RELEASE: Thursday, June 23, 1994, 10 a.m. (Central time) CONTACT: David Swank, Chair, NCAA Committee on Infractions

DEPARTMENT OF ENVIRONMENTAL PROTECTION Office of Oil and Gas Management

How HSE regulates onshore oil and gas

CONTACT: Robert A. Stein, acting chair, NCAA Infractions Appeals Committee

MOCS. Multiple Opening Circulation Sub. Fluid Bypass Valve

Arbitration CAS 2015/A/4210 Karam Gaber v. United World Wrestling (FILA), award of 28 December 2015

A PROACTIVE APPROACH TO ADDRESSING ANNULAR PRESSURE ISSUES AND STRAY GAS MIGRATION IN THE UNCONVENTIONAL SHALE PLAYS

Via Federal Express Rockville, MD 20850

Frequently Asked Questions Directive 056 Facilities Technical

The Developing Design of the Blowout Preventer in Deep Water

and we protect correlative rights. And, as I said, we do this throughout the State, regardless of land ownership.

5. INSPECTION AND TESTING PROCEDURES

USTA NorCal CAP. Rev. A 4/20/2017

Oil Well Potential Test, Completion or Recompletion Report, and Log

7.0 DEVIATION and EXCEPTION of a PREVIOUSLY APPROVED PROTOCOL

VOLUMETRIC METHODS and STRIPPING OPERATIONS

USTA NorCal Sportsmanship Committee Meeting December 12, 2006 Alameda Office

R.H. Hobbs, Chair N.F. Nicholls, Commissioner October 6, 2006 L.A. O Hara, Commissioner O R D E R

Practice Exam IADC WellSharp Driller and Supervisor

Captains Meeting 2009 Introduction to Well Testing- Expro. Edwin Schoorl

* William A. Sala, Jr. John A. Roscher. Columbia Gas Transmission, LLC * Sorana Linder 700 Louisiana Street, Suite 700 Director, Regulated Services

USTA NorCal CAP. Rev. A

Dynamically Positioned (DP) Mobile Offshore Drilling Unit (MODU) Critical Systems, Personnel and Training

SOUTH BERKELEY SOCCER LEAGUE RULES AND REGULATIONS

WellCAP IADC WELL CONTROL ACCREDITATION PROGRAM

3.01B(2) Section and District/Area. Each Sectional Association shall appoint a Sectional Association League

USTA/COLUMBIA TENNIS LEAGUE SOUTHERN COMBO DOUBLES REGULATIONS 18 & Over, 40 & Over, 55 & Over, 65 & Over League Year 2018

PGA TOUR INTEGRITY PROGRAM MANUAL. Effective January 1, 2018

TENNIS AUSTRALIA CODE OF CONDUCT Incorporating the Tennis Australia Junior Disciplinary System (section 1.1)

SEMS II: BSEE should focus on eliminating human error

Transcription:

STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION 333 West Seventh Avenue Anchorage, Alaska 99501 Re: Failure to Test BOPE After Use Milne Point Unit I-03 Docket Number: OTH-15-029 PTD 1900920 DECISION AND ORDER On November 16, 2015 the Alaska Oil and Gas Conservation Commission (AOGCC) issued a Notice of Proposed Enforcement Action (Notice) to Hilcorp Alaska, LLC (Hilcorp) regarding the Milne Point Unit well I-03 (MPU I-03). The Notice was based upon Hilcorp s failure to notify AOGCC of the use of blowout prevention equipment (BOPE) and the failure to test the BOPE after its use prior to reentering MPU I-03 to run the well completion. The Notice proposed specific corrective actions and a $40,000 civil penalty under AS 31.05.150(a). Hilcorp requested an informal review. That review was held February 18, 2016. Summary of Proposed Enforcement Action: The Notice identified violations by Hilcorp of 20 AAC 25.285. Hilcorp shut in MPU I-03 with BOPE to stop the flow of fluids from the well. After use of the BOPE, Hilcorp was required to test the used BOPE components before the next wellbore entry. Hilcorp failed to test the BOPE components used during well control operations. The Notice proposed the following corrective actions be completed by Hilcorp: 1) provide AOGCC a detailed description and an example of its regulatory compliance tracking program; 2) provide AOGCC a copy of the written management of change procedures that correct the violations; and 3) provide AOGCC a detailed written explanation that describes how recurrence of the violations will be prevented. For violating 20 AAC 25.285 the AOGCC proposed civil penalties under AS 31.05.150(a) as follows: - $20,000 for failing to notify AOGCC of the use of BOPE to prevent the flow of fluids from MPU I-03. - $20,000 for failing to test BOPE used to prevent the flow of fluids from MPU I-03. Blowout Prevention Equipment: Secondary well control equipment (known as BOPE) includes the casinghead assembly of valves, rams and other pack-off devices installed on a rig during drilling, completion, and workover operations. The BOPE designed to close around the drill pipe, work string, tubing, casing or tools is able to completely close the top of the casing to control well pressure. The rated working pressure of the BOPE must exceed the maximum potential surface pressure. BOPE must be maintained in good operating condition at all times and must be regularly tested.

Page 2 of 7 If any BOPE is used for well control or equivalent purpose, the components used must be function pressure-tested before the next wellbore entry. Informal Review: On January 29, 2016 Hilcorp submitted a consolidated brief ( brief ) in advance of an informal 1 review covering four Notices of Proposed Enforcement Actions, including this action. On February 18, 2016 Hilcorp was provided an opportunity to present the information it claimed AOGCC should have considered in its proposed enforcement action. Hilcorp argued that the rig s Well Site Manager provided proper notice to AOGCC by electronic mail regarding the use of BOPE at MPU I-03. Hilcorp also argued that the well flowing was an expected possible consequence of the operation and that actions taken in response were consistent with its work plan. Hilcorp included copies of email messages both internal to Hilcorp and between Hilcorp s Well Site Manager and AOGCC. Hilcorp asserts that AOGCC s proposed penalties are based on an incomplete understanding of the factual record, and claims AOGCC has overlooked communications between Hilcorp and AOGCC personnel. Hilcorp also contends that the BOPE was not used for well control purposes 2 at MPU I-03, therefore no re-test was required. Discussion: Workover operations on MPU I-03 were approved by AOGCC on April 23, 2015 (Sundry Approval 315-233), authorizing Hilcorp to replace a failed electric submersible pump (ESP) with a new ESP completion. Operations reports indicate Hilcorp commenced the workover with Nordic Rig 3 on April 30, 2015. MPU I-03 began to flow during workover operations on May 1, 2015. The well was shut in with the annular preventer and with a floor safety valve installed in the work string. Kill weight fluid was also ordered as there was an insufficient volume available at the location to displace and kill the well. The AOGCC has considered the factors in AS 31.05.150(g) in its determination of penalties for the MPU I-03 violations. Hilcorp neither offers mitigating factors nor demonstrates AOGCC missed information in reviewing the enforcement action. Relying on emails between Hilcorp and AOGCC, Hilcorp argued proper notice had been provided and that AOGCC approved Hilcorp s failure to report use of BOPE. However, review of internal Hilcorp emails establishes that critical factual information known to Hilcorp was not provided to AOGCC when Hilcorp asked if it was required to report use of the BOPE. Specifically, Hilcorp failed to provide information regarding well pressures, failed to advise AOGCC there were insufficient materials on hand for weighting up the well fluid, and failed to advise AOGCC that a floor safety valve was installed to stop the flow of fluids to surface from the work string. All of the information Hilcorp failed to provide was critical to AOGCC s determination of whether a report was required. Because that information points to a well control event instead of a planned activity, 1 Other 15-025 (Unauthorized Changes to Approved Permit; MPU J-08A); Other 15-029 (Failure to Test BOPE After Use, MPU I-03); Other 15-030 (Failure to Notify of Changes to an Approved Permit; MPU J-01A); Other 15-031 (Failure to Notify of Changes to an Approved Permit; MPU J-09A) 2 Hilcorp Submission to AOGCC for Informal Review (Dockets OTH-15-25, OTH-15-29, OTH-15-30, and OTH- 15-31), pages 1 and 15.

Page 3 of 7 Hilcorp would have been required to report its use of the BOPE had it provided the missing information. Hilcorp has provided no evidence to support its claim this well control event was a planned event. In fact, its failure to maintain sufficient materials at the locations to weight up the well fluid undermines its claim that the use of the BOPE was planned. AOGCC s proposed enforcement noted the violation here was not isolated and is emblematic of ongoing compliance problems with Hilcorp rig workover operations. AOGCC also noted the disregard for regulatory compliance is endemic to Hilcorp s approach to its Alaska operations. Hilcorp objects to these statements, characterizes AOGCC s observations as inflammatory and harsh, and claims virtually all of its operations are performed in full compliance. Table 1 attached to this Decision lists numerous incidents of noncompliance, some of which are recurring events. Specific to this incident, in 2013 the AOGCC fined Hilcorp a total of $115,000 for violations relating to failure to test BOPE after use for well control. Previous versions of Table 1 have been provided to Hilcorp s Alaska managers during meetings about compliance concerns. The noncompliance history even triggered at least one unprecedented meeting with Hilcorp field operations staff at their Kenai field office to emphasize AOGCC s concerns and 4 elaborate on AOGCC expectations for regulatory compliance. Findings and Conclusions: Hilcorp violated 20 AAC 25.285. Hilcorp was clearly aware of the requirement to notify the AOGCC that the BOPE was used to control flow from the well based on the internal Hilcorp email correspondence. While Hilcorp did initiate contact with AOGCC staff regarding the use of BOPE, the email from Hilcorp to the AOGCC failed to advise AOGCC that MPU I-03 was flowing and had been shut in with the annular preventer and a floor safety valve, did not mention that the well started flowing with oil to surface almost immediately upon releasing off the packer, nor were the shut in tubing and shut in casing pressures provided to the AOGCC. Hilcorp communicated to AOGCC that only the annular preventer was used to shut in while 5 waiting to increase the workover fluid density. If the details included in the internal Hilcorp emails (May 2, 2015, 5:43 am) had been provided in the email to AOGCC questioning the need to report a BOPE use (May 2, 2015 12:31 pm), the AOGCC would have required a BOPE use report and instructed Hilcorp that the used BOPE components must be tested before reentering the well. Hilcorp s suggestion that the use of BOPE at MPU I-03 was not for well control is unconvincing. The MPU I-03 event was clearly well control related, clearly warranted closure of the BOPE to prevent the flow of well fluids at surface, and required proper notice and testing of all used components of the BOPE prior to running the replacement ESP completion. AOGCC does acknowledge that notice of BOPE use did occur despite Hilcorp s communication being misleading and incomplete. As a result, the proposed penalty will be mitigated. 3 3 AOGCC Other Order 80, Failure to Notify of Changes to an Approved Permit; and Failure to Test Blowout Prevention Equipment 4 Meeting requested and arranged by Hilcorp management; held November 11, 2013 5 Hilcorp Submission to AOGCC for Informal Review (Dockets OTH-15-25, OTH-15-29, OTH-15-30, OTH 15-31), Exhibits 21 and 22

Page 4 of 7 Now Therefore It Is Ordered That: A civil penalty in the amount of $20,000 is imposed for the initial event of failing to test BOPE after being used for well control purposes and prior to the next wellbore entry (in this case prior to running the replacement ESP completion). AOGCC is eliminating the penalty for failure to notify of the use of BOPE. In addition, Hilcorp is instructed to provide AOGCC with a detailed explanation of how recurrence of this violation will be prevented in the future. Included in the corrective actions must be how Hilcorp has acted or will act to ensure accurate information is provided to AOGCC for decisions. As an Operator involved in an enforcement action, you are required to preserve documents concerning the above action until after resolution of the proceeding. Done at Anchorage, Alaska and dated. //signature on file// Cathy P. Foerster Chair, Commissioner //signature on file// Daniel T. Seamount, Jr. Commissioner Attachment RECONSIDERATION AND APPEAL NOTICE As provided in AS 31.05.080(a), within 20 days after written notice of the entry of this order or decision, or such further time as the AOGCC grants for good cause shown, a person affected by it may file with the AOGCC an application for reconsideration of the matter determined by it. If the notice was mailed, then the period of time shall be 23 days. An application for reconsideration must set out the respect in which the order or decision is believed to be erroneous. The AOGCC shall grant or refuse the application for reconsideration in whole or in part within 10 days after it is filed. Failure to act on it within 10-days is a denial of reconsideration. If the AOGCC denies reconsideration, upon denial, this order or decision and the denial of reconsideration are FINAL and may be appealed to superior court. The appeal MUST be filed within 33 days after the date on which the AOGCC mails, OR 30 days if the AOGCC otherwise distributes, the order or decision denying reconsideration, UNLESS the denial is by inaction, in which case the appeal MUST be filed within 40 days after the date on which the application for reconsideration was filed. If the AOGCC grants an application for reconsideration, this order or decision does not become final. Rather, the order or decision on reconsideration will be the FINAL order or decision of the AOGCC, and it may be appealed to superior court. That appeal MUST be filed within 33 days after the date on which the AOGCC mails, OR 30 days if the AOGCC otherwise distributes, the order or decision on reconsideration. In computing a period of time above, the date of the event or default after which the designated period begins to run is not included in the period; the last day of the period is included, unless it falls on a weekend or state holiday, in which event the period runs until 5:00 p.m. on the next day that does not fall on a weekend or state holiday.

Page 5 of 7 Table 1 Hilcorp Noncompliance History Date Non-Compliance Location AOGCC 6 Action April 2012 Missing SVS tests; Failure to notify AOGCC for test witness Comments Westside CI No action taken Numerous efforts by AOGCC to obtain SVS test results for IRU, PCU, LRU, Stump Lake; some missing SVS tests between 5/2011 and 2/2012; some failure to notify AOGCC for opportunity to witness (previous operator responsible for some tests) 5/8/2012 Missing Kill Line Valve Swanson River 21-22 BOPE test; Inspector observed missing kill line valve (Aurora Rig 1) at inlet to stack (1 installed; 2 required) 9/17/2012 Choke Manifold Valves Swanson River 21-25 Corrective Rig crew performing choke manifold test greased and cheated closed during BOPE test (Aurora Rig 1) actions had to cheat choke manifold valves closed to pass pressure test 10/2/2012 Notice of Meter Calibrations Happy Valley 10/18/2012 Incorrect BOPE Test Soldotna Ck 44-33 Pressure (Doyon Rig 1) Failure to notify of changes to approved permit 10/23/2012 Soldotna Ck 44-33 (Doyon Rig 1) Well control; Failure to test BOPE after use 10/26/2012 Failure to Test BOPE within 7 days Granite Pt 32-13RD (crane workover) 10/31/2012 Improper gauge on IA Trading Bay Unit 45 Corrective actions See 10/23/12 enforcement Civil Penalty; Corrective Actions (Other Order 80) Denied request for delaying BOPE test AOGCC has not received notice of meter calibration for Happy Valley custody transfer meter for at least as long as Hilcorp has been responsible for the meter; schedule provided 10/9/12 When finally tested BOPE after use (10/18/12), tested to wrong pressure (4000psi instead of 5000psi) Hilcorp failed to follow well drilling procedures approved in PTD by AOGCC; failed to notify AOGCC of changes to well plan; failed to maintain well in overbalanced condition; lack mgt of change Hilcorp failed to test BOPE used in well control operations prior to first wellbore entry following use Test due 10/26/12, started running completion 1500hrs on 10/26 without making any attempt to get test extension (working daylight hours only); landed pipe high, had to trip pipe; request extension 10/27/12 D- none Hilcorp self-reported that gauge was pegged out; 2000psi alarm set, 1000psi gauge; well SI by Hilcorp 6 Notice of Violation; no financial penalty; corrective actions only

Page 6 of 7 Date Non-Compliance Location AOGCC Comments 6 Action 11/29/2012 Missing well control equipment Happy Valley B-16 (Aurora Rig 1) Missing top drive valve(s) on 10/10/12 and again 11/18/12; reviewing Hilcorp response rec d 12/11/12 11/29/2012 Incorrect BOPE test Granite Point #50 Sundry 312-439 required BOPE rams, valves to test to pressure (Schlumberger CT 2) 4500psi; Hilcorp tested to 3500psi 12/6/2012 Conduct of operations Trading Bay Unit G- 32 (Williams Rig 404) Violation found 11/7/12 as part of rig inspection/ and BOPE test witness; hazardous conditions; wellbore fluids on deck; equipment placement; lack of winterization; reviewing Hilcorp response rec d 12/21/12 12/16/2012 Winterization; Conduct of Operations Trading Bay Unit G- 32 (Williams Rig 404) Ordered ops shut down on Rig 404 until corrective actions implemented Inspector arrived 12/15/12 for BOPE test; unable to test due to fluids covering stack well cellar (similar to issued noted in 12/6/12 ); returned 12/16/12 to test BOPE unable to test BOPE (frozen choke manifold, top drive valves, floor safety valves, choke and kill lines along with everything else not in heated enclosure. Rig ops allowed to restart 12/31/12 after corrective actions, inspection and passing BOPE test 12/16/2012 Commence production w/o Nikolaevsk Unit (Red Corrective 12/18/12 Hilcorp contacts AOGCC with notice of approved LACT meter pad) actions SVS testing; AOGCC determined by questioning status that well commenced production 12/16/12; application for LACT meter rec d 1/9/12 4/11/2013 Defeated SVS Sterling 43-09X SVS found defeated 3/15/13 during AOGCC inspection; well was SI without testing 9/30/2013 Defeated SVS Swanson River Field KGSF #1 SVS found defeated 9/2/13 during AOGCC inspection; needle valve on actuator blocked 1/14/2014 Defeated SVS Missing Annulus Gauges Swanson River Field SCU 12A-04; SCU SVS on 3 rod pump wells found defeated during 12/9/13 AOGCC inspection; found SCU 24A-09 w/o 24A-09; SCU 41A-08 4/22/2014 Defeated SVS Ninilchik Unit SD-3; Ninilchik Unit FC-5 8/29/2014 Failure to Test BOPE Trading Bay Unit G- 11 (Moncla Rig 301) Corrective actions the req d pressure gauge to monitor outer annulus SSSV found by AOGCC Inspectors 4/15/14 and 4/16/14; Hilcorp reported on 4/21/14; Inspector required SSSV back in service before departing Rig exceeded allowed 7days between BOPE tests without AOGCC approval

Page 7 of 7 Date Non-Compliance Location AOGCC Comments 6 Action 10/31/2014 Failure to Test Required Ninilchik Unit Paxton Corrective No enforcement; reported by Hilcorp; approved Well Control Equipment 7 & Paxton 8 actions sundry required testing despite wells being isolated from the formation 1/5/2015 Workover Safety Concerns Hilcorp Cook Inlet Meeting 1/9/15; List of concerns provided to Hilcorp addressing and Kenai Peninsula Corrective suitability of equipment and procedures; unsafe Rig Workovers actions working conditions associated with rig workovers; onshore and offshore Cook Inlet 1/7/2015 Casing Valves Inaccessible Ninilchik Unit Paxton Meeting 1/9/15; Frozen well cellar found by Inspector 1/7/15; operator 8 Corrective instructed to thaw cellar; no action taken per Hilcorp actions (1/9/15 mtg - operator unclear about req d action ); AOGCC Deficiency Report created to track corrective actions identified during inspections 2/4/2015 Defeated SVS Northstar Unit NS-15 SSV found defeated during 1/23/15 AOGCC inspection 4/22/2015 Failure to Obtain Approval Kenai Gas Field KDU Operating without required competent tubing and for Continued Production 1 packer; no AOGCC approval (20 AAC 25.200); discovered as part of well review; well shut in 9/4/2015 Rig Operations with Failed Milne Pt Unit F-96 Notice of AOGCC Docket OTH 15-024; Notice sent 11/25/15; Gas Detection System Proposed informal review held 2/18/16; Final Decision pending Enforcement (Civil Penalty) 10/1/2015 Failure to follow approved All Hilcorp-operated Shut down well AOGCC-ordered suspension of all rig workover procedures/good oilfield rigs performing workover operations; corrective actions required; conditional practices workovers operations approval for restart 10/21/15