User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

Similar documents
1 DRIVE INDUSTRIAL IMPACT WRENCH

INSTALLATION OPERATION MAINTENANCE

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

MyControl Bathing System Signature Series

A4s Operation Manual

accidents which arise due to non-observance of these instructions and the safety information herein.

New AQF Filter Polymer Filtration System

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

TECHNICAL DATA. Q = C v P S

Instruction Manual for Configura Cushionair Portable Pump

36H SERIES Combination Gas Valve

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual

/2004 US/CA

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax:

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

AIR INLINE METAL SHEAR

ACV-10 Automatic Control Valve

Bermad Pressure Reducing. Model: 42T

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

TECHNICAL DATA. Q= Cv S

GALISO SOAP OPTION FOR PCT-ADW-D

12V AIR STATION ALL-IN-ONE

deluxe toilet safety support

INFLATION STATION. Cordless OWNER S MANUAL MODEL NO: RCP-C65B

Rotary Abreast Automatic Teat Sprayer User Manual. Technical Manual Revision 0.01

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Your safety and the safety of others are very important.

INSTALLATION & START-UP INSTRUCTIONS. Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS

WSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, PHONE #: (970) FAX #: (970) TO-Clean Manual

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Installation, Operation, and Maintenance Manual

PANACEA P200 STAINLESS STEEL USER MANUAL

Conversion instructions from natural gas to propane

Safety, Operating and Maintenance Manual. TRAIN Rat DS9-TRAIN

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

Napa Technology Trouble Shooting. For Premier & Premier PLUS Models

Operating Instructions Part No

Sterisil Ac+ Installation & Operating Manual

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

OWNER S MANUAL. Page: 1 of 8

Product Information News

OC Panel High Limit Aquastat Kit, Manual Reset p/n

OPERATOR s MANUAL AHCON PCI 3000

1/4 Air Ratchet Wrench

DuPage County Environmental, Safety, Health & Property Loss Control Program Hazardous Energy Control (Lockout/Tagout)

Touch Screen Guide. OG-1500 and OG Part # T011

TECHNICAL DATA CAUTION

Operation Manual Guillotine Cutter RC-5

750 Cable Cutter INSTRUCTION MANUAL

10 DRIP NOZZLE WATERING DRIP KIT Model / Model 46095

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

Related Products: Auto Drain Valve. Model/Specifications. Model

BOTTOM HINGED FLOOD BARRIER

Pressure Dump Valve Service Kit for Series 2300 Units

General No. 25 and D-25 Handy Operating Instructions

Operating Instructions Part No

Installation and Use Manual

OPERATION MANUAL NTF-60 Plus

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

Installation Instructions

1200B2 Series Service Regulators. Instruction Manual

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

Winter Shut Down Procedure

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

DK ton, Double-acting, Die-type Crimping Tool

IMPACT WRENCH ASSEMBLY AND OPERATING INSTRUCTIONS

NIV EAU MATIC ST User Manual Made in Canada

Operator: Save these instructions for future use!

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

Roller AC Servo System

New product release. Universal Rebreather Monitor (URBM) Single O2 cell and Dual HP package

Agilent 1290 Infinity Pump Head Maintenance

NORMAL OPERATING DISPLAYS GENERAL OPERATION

Offset head dual chuck

User Instruction Manual

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual

PANACEA P100 LOW PRESSURE USER MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INLOOP ACE CRUDE OIL SAMPLER

MODELS (2 foot Version) (4 foot Version)

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

HD Mast Series. Installation & Operation Manual

XpressFill XF4500 Counter Pressure Filler. Operating Instructions

Scald Protection Three-Way Thermostatic Mixing Valve

Transcription:

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

Copyright Disclaimer Trademarks and patents Intended use Contact info 2011 Inflotrolix, Inc. This document may not be copied in whole or in part or otherwise reproduced without prior written consent from Inflotrolix, Inc., except where specifically permitted under Canadian, US and international copyright law. The information in this document is subject to change without notice. Inflotrolix, Inc. ( Inflotrolix ) assumes no responsibility for inaccuracies or omissions and specifically disclaims any liabilities, losses, or risks, personal or otherwise, incurred as a consequence, directly or indirectly, of the use or application of any of the contents of this document. For the latest documentation, contact your local supplier or visit us online at www.aqua-protec.com. This publication may contain examples of screen captures and reports used in daily operations. Aqua-Protec is a registered trademark ( ) and is patent pending in Canada and the United States. Use this product only for the purpose it was designed for; refer to the data sheet and user documentation for details. For the latest product information, contact your local supplier or visit us online at www.aquaprotec.com. For contact information, see our Web site: www.aqua-protec.com/en. 2 P a g e Rev. V1.6-EN 11/08/2014

Table of Contents User Manual... 1 1. Introduction to Aqua-Protec... 4 2. Intent of use... 4 3. How it works... 4 4. Powering... 4 5. Battery replacement... 5 6. Balloon replacement... 5 7. How to navigate your Aqua-Protec... 5 7.1. How to change language... 5 7.2. Software release... 6 7.3. Aqua-Protec history... 6 7.4. Technician menu... 6 8. Operation modes... 6 8.1. STANDBY mode... 7 8.2. ALERT mode... 7 8.3. Weekly self-testing mode... 8 9. Maintenance... 8 10. Precaution for your Aqua-Protec... 8 11. Work to be done in your sewer?... 9 11.1. Balloon removal instruction... 9 11.2. Insert the balloon in the cleanout... 10 12. Information displayed... 11 13. Contact... 11 14. Certificates and Patent... 11 3 P a g e Rev. V1.6-EN 11/08/2014

1. Introduction to Aqua-Protec Aqua-Protec is design to protect you, your family and all your possessions stored in the basement. Aqua-Protec is an automatic electro-pneumatic device to protect you against back water situation. Unlike conventional mechanical valves, the Aqua-Protec system is completely automated, and reliable. It is composed of a control panel, a 17 umbilical cord and a Retractable Pneumatic Sealing Module (RPSM or the balloon). The RPSM is equipped with sensors which, in case of municipal sewer backups, are triggered, sending a signal to the onboard compressor to deploy the RPSM by filling it with 11.5 PSI of air pressure, causing the RPSM to expand firmly into the 4 sewage drain pipe. This manual gives directions on how to use your Aqua-Protec. 2. Intent of use Aqua-Protec is a device used to minimize the risk of sewer backup in a single family residence. It is fully automatic, so it requires very little intervention on your part. It will protect your home at all times, even in the most severe situations. 3. How it works In case of sewer backup, sensors will detect the high level of water in just few seconds and communicate to the control panel. Air will be compressed into the balloon which will seal the sewer pipe and protect your residence. It will remain inflated until the retraction of water from the sewer pipe. When Aqua-Protec no longer detects water, it will deflate and automatically return to standby mode until the next event. 4. Powering During installation, your certified plumber connected the control panel of the Aqua Protec system to a 120V outlet. During installation, the emergency battery is also connected. Solid green light (figure1) indicates that the Aqua Protec is properly powered (primary and emergency). When the green light flashes (figure2), it indicates a power failure and the compressor will be running on backup power battery and will continue to do so until the power is restored. Figure 1 Figure 2 Despite the power outage, the device remains fully operational for a period of one week. 4 P a g e Rev. V1.6-EN 11/08/2014

5. Battery replacement The emergency battery has an expected life of 3-4 years. It can keep the system fully functional for more than a week in the event of a power outage. Aqua-Protec notifies you in advance when the battery no longer keeps its charge and a replacement is necessary. The message «REPLACEMENT REQUIRED» appears on the display screen on the control panel. 6. Balloon replacement Aqua-Protec is a fully-automated system and requires little human intervention. It should protect your home at all times, even in the most extreme situations. In order to ensure its proper operation, the RPSM has a limited recommended lifespan and must be replaced at the earliest of the following: After being deployed for a duration of more than 24 consecutive hours, or After 10 deployments of duration of more than 1 hour, or After 5 years of service. The control panel will inform you when the balloon requires to be replaced. 7. How to navigate your Aqua-Protec Your certified plumber configured your Aqua-Protec. You can access to the menu by pressing the CHECK ( ) button. The display will list followed options: 1) LANGAUGE 1) VERSION 2) HISTORY 3) TECHNICIAN 7.1. How to change language You can modify the displayed language To select a new language: 1) Press the CHECK ( ) button; 2) With up and down arrows ( ) navigate until you reach LANGUAGE line; 3) Use RIGHT arrow ( ) to select LANGUAGE menu; 4) Different LANGUAGE are listed. Use up and down arrows ( ) to navigate; 5) Use RIGHT arrow ( ) to confirm the desired LANGUAGE; 6) Use LEFT arrow ( ) to return to previous menu. 5 P a g e Rev. V1.6-EN 11/08/2014

7.2. Software release You can validate on which release your Aqua-Protec operates 1) Press the CHECK ( ) button; 2) With up and down arrows ( ) navigate until you reach VERSION line; 3) Use RIGHT arrow ( ) to see software information; 4) You should see release V2.0_C11 or higher; 5) Use LEFT arrow ( ) to return to previous menu. 7.3. Aqua-Protec history Aqua-Protec will protect your property from all sewer backup situations and list and record any incidents when the system is deployed in this menu. It will indicate the date, hour and how long the event occurred. You will have the information on how many times Aqua- Protec protected your home. If nothing is listed, it s means that no sewer backup occurred. 2) Press the CHECK ( ) button; 3) With up and down arrows ( ) navigate until you reach HISTORY line; 4) Use RIGHT arrow ( ) to see history information; 5) Use LEFT arrow ( ) to return to previous menu. 7.4. Technician menu This menu is intended to be used only by the certified plumber for periodic maintenance or inspection of Aqua-Protec. It requires a password. 8. Operation modes Once your Aqua-Protec is fully installed and configured, it can be in 3 different status modes: STANDBY mode; ALERT mode; WEEKLY SELF-TESTING mode. 6 P a g e Rev. V1.6-EN 11/08/2014

8.1. STANDBY mode Under normal conditions, the display is showing STANDBY and solid green light is on (figure3). The Aqua-Protec is working properly and ready to react to protect your home from a sewer backup situation. 8.2. ALERT mode Figure 3 During a sewer backup situation, Aqua-Protec is in ALERT mode. An audible alarm will be heard, ALERT mode is displayed, green light is OFF, solid yellow light is ON (water detection-figure4) and solid red light is ON (sewer sealed-figure5). Aqua-Protec will display WATER DETECTED and SEWER SEALED. After a detection of 5 consecutive seconds, system will switch to Alert Mode and will seal the drain. After 5 seconds Figure 4 Figure 5 Press the «X» button to mute the alarm sound. CAUTION: During sewer backup situation, Aqua-Protec seals the sewer pipe. Used water can NOT be evacuated. To avoid flooding, do NOT use water in the house. Do NOT flush ANY toilets, stop using the shower. Stop in-progress water-using appliances such as dishwashers and washing machines. Note: Aqua-Protec can be connected to Nowa, which is an automatic water shutoff valve to prevent water usage. Visit www.nowasystems.com for more information. Aqua-Protec can also be linked to your home alarm monitoring system. To be sure that the sewer backup situation is over and the water level is back to a safe level, Aqua-Protec will remain in ALERT mode for 30 minutes. It is normal to see the solid red light ON and yellow light OFF (figure6). Time left to free the sewer is displayed on the control panel. Audible alarm will inform you when the sewer will be free. Sound will last for 10 consecutive minutes and then 10 seconds per minutes until you press the X button. Aqua-Protec wants to make sure you are aware of the event. Even if no one is home during the event, you will be informed upon your return. 7 P a g e Rev. V1.6-EN 11/08/2014

Figure 6 Press the «X» button to mute the alarm sound. 8.3. Weekly self-testing mode The reliability of Aqua-Protec is assured by its weekly auto-testing. Once a week, Aqua- Protec is self-checking the system. The control panel partially inflates the RPSM and maintains the pressure during 15 minutes. Aqua-Protec will detect compressor failure, slow leak, and low battery. This test is run without any human needs and it does NOT affect used water evacuation. You can use water without any issue. When test is preceded, all light are turned OFF. Figure 7 If Aqua-Protec detects any abnormal situation, it will inform you with an audible alarm sound. It will display a message or an error code on the control panel screen. Press the «X» button to mute the alarm sound. Contact Aqua-Protec technical support 1-877-287-7777, and we will assist you. 9. Maintenance Aqua-Protec is the most reliable device on the market because it is the only one that complies with IGC 283-2011 (IAPMO Standard) and auto-test itself weekly, but due to its operating environment, we recommend an annual inspection by certified plumber especially if many events of sewer backup occurred. It is a quick inspection that assures optimal performance of the product. Contact us is you think your system need some attention. 10. Precaution for your Aqua-Protec To ensure optimum performance of Aqua-Protec, cable between control panel and the clean out must remain free at any time. Do not stack any object on it. Air used to inflate the balloon is circulating in the cable. If the cable is pinched, system may not operate properly. Weekly auto-test will detect and inform you if cable is pinched. 8 P a g e Rev. V1.6-EN 11/08/2014

11. Work to be done in your sewer? Over time, your sewer may require to be inspected, unclog, repaired or clean. The clean out will be used to execute the work by your licensed plumber. Aqua-Protec can easily be removed to do the work. In this situation, you need to inform the plumber that an Aqua-Protec is installed in the clean out. If the plumber in not familiar with Aqua-Protec, he can refer to Balloon removal instruction in the user manual. 11.1. Balloon removal instructions Attention: Before beginning balloon removal, make sure the system in not running its weekly auto-test. 1. Turn off the power : 1.1. Unplug the power supply from the walled outlet 1.2. Disconnect one terminal of the battery. 2. Loosen the cable gland of the cleanout cap. 3. Loosen and remove cleanout cap from the cleanout 4. Keeping the anchor ring attached, carefully pull on the installation rod and the steel extraction cables until the balloon is retracted out of the clean-out. Lubricate with water and soap as required. 5. Place the balloon on a clean surface. During installation, the balloon was covered with a silicone lubricant to ensure easy positioning and sealing. Accumulated residue on the balloon may affect the ease to reposition of the balloon into the cleanout. Once the work is completed, Aqua-Protec can be reinserted in the cleanout. Repositioned correctly, it will once more protect your basement from sewage backups. See insert procedures in this manual. 9 P a g e Rev. V1.6-EN 11/08/2014

11.2. Balloon insertion instructions 1. Insert the balloon into the cleanout, taking care to direct probe sensors in same direction as the flow in the sewer. 2. Using positioning rod, slide the balloon until the anchor ring sit at the bottom of cleanout cap threads. Note: To ease the way down back into the cleanout, silicon lubricant can be used on the balloon. Do not use any other grease type. Probe sensors must remain clean. 3. Make sure steel wires are going thru the anchor ring. 4. Tighten cleanout cap in place. Hand tightening is enough to seal the cap. 5. Tighten cable gland to insure water tightness. Hand tightening is enough to seal the cable gland. 6. Repowering the system 6.1. Connect the battery terminal 6.2. Plug the power supply into the walled outlet. We recommend running a full test to confirm that the system is functional. If the test is not performed at this time, the system will run the test during the weekly selfcheck. Figure 8 10 P a g e Rev. V1.6-EN 11/08/2014

12. Information displayed Here is a list of messages you can see on the control panel screen of Aqua-Protec: Messages STANDBY WATER DETECTED ALERT mode INFLATION KEEP DEFLATION SEWER FREE SEWER SEALED MANUAL CONTROL OUT OF ORDER Description Aqua-Protec is armed Aqua-Protec detects water. If detection last more than 5 consecutive seconds, Aqua-Protec will switch in ALERT mode Sewer backup situation is occurring Aqua-Protec inflates the RPSM RPSM is sealing the sewer. Do NOT use water services. Aqua-Protec deflates the RPSM RPSM is retracted and sewer is free SEWER is sealed. DO NOT used any water services : toilet, dishwasher, washing machine, shower, etc. Aqua-Protec is in manual mode and will NOT detect water. Technician forgot to return to automatic mode. Call back the installer or technical support: 1-877-287-7777. Aqua-Protec faced an abnormal situation and need assistance from a certified technician. Call your local supplier or our technical support: 1-877-287-7777 13. Contact Aqua-Protec is made in Canada by Inflotrolix Inc. You can contact our customer service at 1-877-287-7777 You can visit us thru our web site: www.aqua-protec.com 14. Certificates and Patent Patent Pending US2011005615A1 247603 IGC 283-2011 11 P a g e Rev. V1.6-EN 11/08/2014