Regulator from 1800 B series

Similar documents
1800C and 1800C-HC Series Service Regulators

1200B2 Series Service Regulators. Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

American Meter Co. Five-Year Limited Warranty Industrial Regulators

MEGR-1627 Instruction Manual

MEGR-1912 Instruction Manual

1800C and 1800C-HC Service Regulators

Types S100K and S102K Pressure Regulators

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Model 1800 PFM Series Regulator. Technical Bulletin

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

Installation, Operation, and Maintenance Manual

2.0 INSTALLATION & SERVICE

1800CPB2 Service Regulators

1805 Series Relief Valves

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

Industrial Regulator Series 1800/2000

TECHNICAL DATA CAUTION

1800CPB2 Pilot-Loaded Service Regulators

Installation, Operation and Maintenance Manual for Back Pressure Regulator

WW-730. Pressure Sustaining/Relief Control Valve

Model: 43T. Bermad Pressure Relief Valve

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

CS800 Series Commercial / Industrial Pressure Reducing Regulators

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation Troubleshooting Maintenance Instructions Installation / Start-up

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

1305 Series Pressure Reducing Regulators

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Bermad Pressure Reducing. Model: 42T

627 Series Pressure Reducing Regulators

Model 141-A Regulators

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

Types 749B and R130 Changeover Manifolds

SR100 Series Service Regulators. Technical Bulletin

V43 Pressure Actuated Water Regulating Valve

Combination Air Valve

Anti-flood device Model B-1

64 Series Pressure Reducing Regulators

CL34 Regulator Commercial and Industrial Regulator

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

299H Series Pressure Reducing Regulators

299H Series Pressure Reducing Regulators

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

Type OS2 Slam-Shut Device

299H Series Pressure Reducing Regulators

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

LRS(H)4 Pressure-Reducing Regulator User Manual

299H Series Pressure Reducing Regulators

WW-720. Pressure Reducing Control Valve

1800C & 1800C-HC Service Regulators

Types S100C and S102C Pressure

Type CT88 Backpressure Regulator

TECHNICAL INSTRUCTIONS

CL34 Regulator Commercial and Industrial Regulator

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG

Radial Flow Valves. Installation Operation Control Manifold Control Loops Repair Parts. ANSI Class 150, 300 and 600 IM

RD(H)20/25 Pressure-Reducing Regulator User Manual

Type ACE95jr Tank Blanketing Valve

Operation Manual Piston Sensed Gas Pressure Regulators

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

WW-720. Pressure Reducing Control Valve

Engineering Data Sheet

627 Series Pressure Reducing Regulators

HIGH RATE BASKET STRAINER

TECHNICAL DATA. Q = C v P S

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

R122H, R222, R232A, and R232E Series Instruction Manual

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

Type ACE97 Pad-Depad Valve

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

Types 95L and 95H Pressure Regulators

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

Wilo Triple Duty Valve / Triple Service Valve Installation and operating instructions

Float Operated Level Controllers

CL31 Series Commercial Regulator. Advanced Metering and Regulation Technology at Work.

Series 100 Slam Shut Valve. Technical Bulletin

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

CL38 Regulator Commercial & Industrial Regulator

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

OPERATING AND MAINTENANCE MANUAL

1213B2 Service Regulators Maximum Inlet Pressure 125 PSIG

R600 and HSRL Series Instruction Manual

CL231 Series Regulator Commercial Regulator

Installation, Operation, and Maintenance Manual

Type R622 Pressure Reducing Regulator

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1

Transcription:

Regulator from 1800 B series Regulator from 1800 B series Measuring of industrial gases frequently requests a precise pressure regulation for the purpose of dosage and proccesing. UNIS FAGAS has two kinds of pressure regulators, 1893 B and 1853 B, in its production programme. These regulators enable economical and precise regulation of pressure in various applications, as well as protection of consumers from overpressure and undrepressure in the installation. Application 1. Gas installations in individual houses, 2. Gas installations in appartment buildings, 3. Gas installations in indusrty and small economy, 4. Low pressure pilot regulator, 5. Pressure reduction from bar to mbar. www.fagas.ba

General Information: 1800B Serie s Service Regulators The 1800B Regulators are available as Full Capacity Internal Relief Models. Series 1800B Regulators are also available with over and underpressure shut-off protection. Available valve body sizes: 3/4" x 3/4", 3/4" x 1", 1" x 1", NPT or BSP-TR. Maximum inlet pressure, normal service (Pin): Depending on orifice size, up to 8.6 bar. Maximum outlet set pressure, normal service (Pout): Depending on spring selection, up to 140 mbar. Orifice Sizes Orifice size 9 / 16" 1 / 2" 3 / 8" 5 / 16" 1 / 4" 3 / 16" 1 / 8" Regulator springs Outlet Pressure Range Color code Part Number 9-15 mbar Blue 70017 P043 14-20 mbar Yellow 70017 P044 18-30 mbar Red 70017 P045 29-41 mbar Brown 70017 P046 38-56 mbar Purple 70017 P047 53-71 mbar Black 70017 P048 70-140 mbar Tan 70017 P049 * Other Pressure Ranges on request 1. Install, operate, inspect and maintain the regulator as outlined in the following instructions and in accordance with your company's policies and applicable state and local codes and laws. Failure to follow these instructions may result in damage to the regulator or personal injury. 2. Check installation location for suitability. It is possible that physical changes have been made to the building site since the regulator and location were originally selected. 3. Examine regulator for shipping damage. 4. Check regulator and piping for foreign matter which may have accumulated during shipment or handling. 5. Check seal plug information to determine if regulator is suitable for intended service. 6. Suitable stop valve(s) should be installed and should be conveniently located. 7. Filters should be used for applications where pipeline contaminant s are suspected to be present. 8. Regulators may be used at temperatures between -30 C and +65 C. Installation: Warning: Inside Installation: Will require a vent line of sufficient diameter to carry gas vented by the regulator to a safe outside location away from any opening in the building. For all sizes of regulators, a 1 NPT or BSP-TR is provided for a vent line. Do not thread a pipe into the vent more than 7 turns so as not to block the vent flapper. Outside Installation: Will require that care be taken to prevent vent opening from freezing closed or becoming blocked or permitting water to enter from any cause. Particular consideration should be given to sites where flooding, snow, or freezing rain may be experienced. The vent or vent line port should point vertically downward and overhead protection should be used where necessary. Preparations: Do not connect the inlet of the regulator to a normal pressure source higher than that recommended. Never connect the regulator outlet to the source of pressure. Observe the flow direction arrow on the valve body. If inlet pressure can exceed the maximum regulator outlet pressure rating, some form of overpressure protection in addition to internal relief may be required. To prevent damage to the regulator and possible personal injury, inlet and outlet pressures must not exceed the regulator pressure rating. regulator pressure rating stated on page 4. 1. Remove all shipping plugs. 2. Use good piping practice. Be sure piping and regulators are free of dirt, pipe dope and other debris. Apply pipe dope to male threads only. 3. Install regulator. Make certain it is piped correctly with inlet pipe connected to the inlet regulator connection and flow is in the direction as indicated by arrow located on valve body (41). The vent should be positioned to prevent entry of water and debris. UNIS FAGAS recommends that the vent face downward. By relieving the two bolts (30), the diaphragm case (33) may be rotated in relation to the valve body (41). Tighten the bolts (30). Inside Installations - A regulator installed within a building should be located as near as practical to the point of service line entrance. 4. Turn gas on slowly. If an outlet stop valve is used, it should be open first. Do not overload the diaphragm with a sudden surge of inlet pressure. 5. Assure that there are no leaks and all connections are tight. 6. The 1800B Series regulator is preset at the factory with the diaphragm in the horizontal position and should not require any adjustment if installed in that position. The outlet pressure may vary as much as 0.5" Page2

W.C. if the regulator is installed in the vertical position. Should you decide to adjust the set pressure, perform the following: a) Turn gas off and depressurize the system. b) Install outlet pressure gauge. Remove seal plug (44). c) Turn gas on slowly. d) Establish a low flow rate 1.2m³/h (20.3l/min). e) Turn pressure spring adjustment screw (47) clockwise to increase outlet pressure or counterclockwise to decrease outlet pressure. f) Establish the set pressure within the range limits of the pressure spring used. g) To test for the regulator's ability to fully shut off (lockup), shut off all flow downstream of the regulator. At lock-up, the outlet pressure will be somewhat higher than the set pressure. However, if the pressure continues to rise after 3 seconds, the regulator must be repaired. Observe for 30 seconds. h) When the set pressure has been properly adjusted, depressurize and remove gauge(s) and lines. i) Replace seal plug (44). j) Pressurize and check all connections for leaks. Inspection: Inspection and maintenance of the 1800B Series regulator has been simplified for practical reasons. Repair parts are offered if maintenance of the regulator is required. Inspection of the valve seat disc (28) and orifice valve (26) may be performed in the field. Follow the procedure described below. Care should be exercised to prevent foreign matter from entering the regulator. Procedure for Inspection of Valve Seat Disc and Orifice 1. Shut off gas supply and depressurize the regulator system. 2. Remove two bolts (30) securing the diaphragm case (33) to the valve body (41) and separate the diaphragm case from the valve body. 3. Visually check the seating edge of the orifice (26). If it is nicked or damaged, it should be replaced with a new orifice to provide proper shutoff. See Maintenance instructions for replacing the orifice. 4. Inspect the surface of the valve seat disc (28). If it is scored or uneven replace it as outlined in the Maintenance instructions. 5. Install new seal ring (29) in the diaphragm case groove. 6. Inspect unit for cleanliness and proper positioning of the parts. Pay particular attention to the proper positioning of the seal ring (29) in the groove. 7. Install the diaphragm case (33) on the valve body (41). Make sure the vent is pointed downward. Replace and tighten the valve body bolts (30). 8. Proceed to Steps 4, 5 and 6 of the installation instructions. Regulators are pressure control mechanisms having numerous moving parts which can wear. In addition, regulator damage may occur from external sources. For these reasons, the regulator should be periodically inspected and checked for proper operation. The frequency of inspection will depend on the severity of the service conditions and the requirements of applicable local codes and regulations. Maintenance: Replacing Seat Disc: 1. Carefully insert the tip of a knife along the edge of the seat disc (28) and lift the seat disc out of the plunger (). 2. Install a new seat disc (28) into the plunger (32), by pressing into place. Make sure that the disc is pressed completely into the plunger (32). 3. Proceed to Steps 5, 6, 7 and 8 of the Inspection Instructions. Handling and Disposal As a knowledgeable user of Unis Fagas products, we are sure that you are aware that parts in the Company's meters and regulators contain or are coated with heavy metals such as cadmium, zinc, lead and chromium. Obviusly, therefore, repair or refurbishment of this equipment should take into account the presence of these materials and should comply with all requirements concerning worker protection, proper disposal and safety, including protection against exposure to dust and fumes. Replacing Orifice: Regulators that have an orifice size change different than shown on the seal plug or tag must have their set pressure reestablished. Mark new orifice size and pressure on the regulator seal plug or on its tag. 1. Shut off gas supply and depressurize the regulator system. 2. Remove two bolts (30) securing the diaphragm case (33) to the valve body (41). Place the diapragm case aside and protect the seat disc from dirt particles. 3. Remove the orifice valve (26) with a 7/8 hex socket wrench. 4. Spraingly apply Henkell G30 or Loctite Stainless steel PST thread sealant or equivalent (not supplied) to the new orifice threads. 5. Carefully start the threads of the orifice into the valve body and tighten to specification. Care must be taken to prevent nicking the orifice. 6. Proceed to steps 5, 6 7 and 8 of the Inspection. Page3

Replacing Pressure Spring: Regulators that have a pressure spring removed or replaced must have their set pressure reestablished. If the pressure spring is different from that shown on the seal plug or tag, mark spring range on the regulator seal plug or on its tag, and cross out the old value. 1. Shut off gas supply and depressurize the regulator system. 2. Remove seal plug (44). 3. Unscrew pressure adjusting screw (47) with a 3/8 screwdriver and remove the pressure adjusting screw completely. 4. Remove the pressure spring (48). Install new pressure spring. 5. Replace the pressure adjusting screw and turn adjusting screw to about mid position. 6. Proceed to Steps 4, 5 and 6 in Installation Instructions. Resetting The OPSO: 1. Shut off gas supply and depressurize in the regulator system. 2. Unscrew the OPSO lower diaphragm case cap (body plug) (14). 3. Pull back the knurled plunger (13) until the diaphragm stem (9) repositions (an audible click). 4. Replace the OPSO diaphragm case cap (body plug) (14) after examining the o-ring (12) for damage. 5. Proceed to Steps 4 and 5 in Installation instructions. Operation & Resetting The UPSO Underpressure Shutoff Operations Under normal operating conditions, natural gas flows through the orifice. If conditions should change to cause upstream line underpressure, the resultant pressure drop will be sensed by the regulator main diaphragm which lowers and causes the plunger and valve seat to move away from the orifice. The restoring force in the orifice valve stem spring holds the valve stem assembly against the seat. If the seat continues to move away from the orifice, the valve stem o-ring will make contact with the inner wall of the orifice body and completely shut off the gas flow. When the underpressure condition has been corrected or repaired and inlet pressure has been introduced to the regulator, the UPSO device is simply reset by unscrewing the cap seal and pulling up on the diaphragm stem. This type of design allows service maintenance to downstream appliances to be performed before upstream pressure is introduced by resetting the regulator. For example, light the pilot light, close valves, etc. In some cases downstream failure may result in the regulator shutting down due to excessive flow lowering downstream pressure. This design has been tested and meets capacity requirements, while insuring efficient and reliable resetting operation even at sub-zero temperatures. UNIS FAGAS d.o.o. Fabrika Gasnih Aparata Sarajevo 71000, Sarajevo Bosnia & Herzegovina Tel: 00387 33 235 395 Fax: 00387 33 235 397 Web: www.fagas.ba Page4

Regulator 1853B Part List Item Part number Description Material PCS 1 01.05.10.001 Seal plug AlCu5PbBi 1 2 01.05.10.002 O-ring Vellumoid 1 2 01.05.10.002.1 O-ring Buna N 70 1 3 01.05.10.017 Adjustm.screw AlCu5PbBi 1 4 01.05.10.018.1 Spring 35-70 mbar C-1.1200 1 5 01.05.10.019 Top TAISi12 1 6 01.05.10.020 Diaphragm stem screw Steel 0265 1 7 01.05.10.021 Upper diaphragm plate Steel 0147HT40 1 8 01.05.10.005 Lower diaphragm plate Steel 0147HT40 1 9 01.05.10.006 Stem diaphragm Steel 4590 1 10 01.05.10.003 Diaphragm Buna N 1 11 01.05.10.004.2 Body bottom TAISi12 1 12 01.05.10.009 O-ring Buna N 70 1 13 01.05.10.007.1 Valve plunger Steel 4590 1 14 01.05.10.008 Body plug AlCu5PbBi 1 15 01.05.10.024 O-ring Buna N 70 1 16 01.05.10.010.1 Valve stem quide AlCu5PbBi 1 17 01.05.10.011 O-ring valve stem Buna N 70 1 18 01.05.10.012 O-ring retainer Steel 4171 1 19 01.05.10.018.1 Cast-off spring C-1.1200 1 20 01.05.10.015 Roll pin Steel 2131 1 21 01.05.11.000 Seat disc, assembly 1 01.05.11.001 AlCu5PbBi 1 01.05.11.000.1 Seat disc Buna N 70 1 22 01.05.10.022 Flange screw Steel 1221 6 23 01.05.10.014 Screw Steel 0265 4 24 01.05.10.023 O-ring tube Buna N 70 1 25 01.05.10.016 O-ring Buna N 70 1 26 01.05.20.001.X Orifice AlCu5PbBi 1 27 O-ring orifice Buna N 70 1 28 01.05.30.001 Valve Seat disc buna N 80 Buna N 80 1 29 01.05.30.002 O-ring body Buna N 70 1 30 01.05.30.003.1 Valve body bolt short Steel 1590 2 31 01.05.30.004 Plunger quide bush Derlin 500 1 32 01.05.31.000 Valve stem 1 01.05.31.001 AlCu5PbBi 1 01.05.31.000.1 Nylon 612 1 33 01.05.32.000 Lower diaphragm cover 1 01.05.32.000.1 TAISi12 1 01.05.32.001 Steel 1331 1 34 01.05.33.000 Lever 1 01.05.33.001 SINT-D 1 01.05.33.002 P 80 1 01.05.33.003 SINT-D 1 01.05.33.004 8-Ugst-36-2 1 35 01.95.34.000 Stem diaphragm 1 01.95.34.001 Steel 1190 1 01.95.34.000.1 Celcon M90 1 36 Spring C-1.1200 1 37 01.05.30.007 Diaphragm plate Steel 0147HT40 1 38 01.05.30.006 Diaphragm Buna N 1 39 01.05.21.002 Valve body tube CuZn30 1 40 01.05.00.004 Nylon 2 41 01.05.21.001.X Valve body NL 42 1 42 01.05.30.011.1 UPSO screw Steel 3990.5 8 43 01.05.30.011.2 UPSO Steel 1490.5 8 44 01.05.30.012.1 Seal plug Ultramid-A3 1 45 01.05.30.008 Reset rod AlCu5PbBi 1 46 01.05.30.013 Gasket Neoprene 1 47 01.05.30.009 Press.Adjustm.screw AlCu5PbBi 1 48 01.05.30.010.X Pressure spring P 70 1 49 01.05.35.000.1 Top 1 01.05.35.001.2 Top TAISi12 1 01.05.35.002 Flapper vent Steel 4571 1 01.05.35.003 Retainer vent flapper Steel 0146HT55 1 01.05.35.004 Protect. screen Steel 4171 1 50 01.95.30.005 Adj. Spring nut Steel 1190 1 Page5