Now it is. easy to switch. CHS TM Steroid Profiling kit and software. Brochure not for distribution in the USA and Canada

Similar documents
High speed UHPLC-MS/MS determination of multiple steroids in human serum using the Nexera MX system for multiplex analysis

LCMSMS Solutions For Steroid Analysis

Simultaneous Determination of a Panel of 22 Steroids in Urine and Serum by SPE and LC-MS/MS

WADA Technical Document TD2014EAAS. Endogenous Anabolic Androgenic Steroids Measurement and Reporting

Development of a Clinical Research Method for the Measurement of Testosterone. Dihydrotestosterone

The instrument should have a mass range from 2 to 2000 m/z or better Interface

Trace-Level Analysis of Metanephrines in Plasma by HILIC LC-MS/MS

Organic Elemental Analysis Series II CHNS/O Elemental Analyzer. proven performance. reliable results

Steroids. Analytical Reference Standards /08

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

May 1, By John Heim,Doug Staples

Integration of amino acid, acylcarnitine and steroids analysis in single FIA/LC-MS/MS platform

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Organic Elemental Analysis Series II Nitrogen Analyzer. proven performance. reliable results

WADA Technical Document TD2016EAAS. Endogenous Anabolic Androgenic Steroids Measurement and Reporting

Agilent Dimension Software for ELSD User Manual

Client: Ultimate Fitness Events - USA 600 Golden Gate St Lake Orion, MI Phone: (248) Identification: 104 DOB: Sex:

National Institute for Public Health and the Environment Annual CRL workshop 22 October Update on natural Hormone studies

Skin metabolism of steroid hormones as endogenous compounds?

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

The Application of QuEChERS in the Extraction of Anabolic Steroids in Whole Blood

Australian Supplement Survey Summary

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

Hair analyses. Hair analysis beyond workplace testing. Ia: Fatal steroid abuse. Identification of stanozolol in hair

Rapid and Reliable Detection of Dissolved Gases in Water

The ICL Insider. Lab Testing: Testosterone. In This Issue. The Debate

Extend the time window for the detection of low level anabolic androgenic steroids and their metabolites

Comparison of 7 Published LC-MS/MS Methods for the Simultaneous Measurement of Testosterone, androstenedione, and dehydroepiandrosterone.

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

MSD 96-Well MULTI-ARRAY CRP Assay

WADA Technical Document TD2018EAAS. Endogenous Anabolic Androgenic Steroids Measurement and Reporting

M/s. Thermo fisher Scientific

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Comparison of 7 Published LC-MS/MS Methods for the Simultaneous Measurement of Testosterone, androstenedione, and dehydroepiandrosterone.

Determination of Selected ASTM Perfluorinated Compounds (PFCs) Using the Shimadzu LCMS No. LCMS-083. No. SSI-LCMS-083

WADA Technical Document TD2010EAAS. Endogenous Anabolic Androgenic Steroids Testing, Reporting and Interpretive Guidance

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Androgen Measurements

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

MATRIX-MG Series. Innovation with Integrity. Automated High-Performance Gas Analyzers FT-IR

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

(2 pts) Draw the line of best fit through the data and estimate the concentration of Fe in your sample solution.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

In-Water Mass Spectrometry for Characterization of Light Hydrocarbon Seeps and Leaks

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Setting a New Standard in Flash Chromatography Performance

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

S on equipment and pipelines along with the constant threat to personnel safety justify major investment in H 2

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

n Budget constraints n Limited benchspace n Interest in running magnetic n User-friendly data management n Benefits resulting from a

Airox Supportair Ventilator

HUMAN IL6 KITS PROTOCOL

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

Longterm Detection of Anabolic Steroid Metabolites in Urine

WADA Technical Document TD2017NA

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs

Tissue-Tek Prisma Plus & Tissue-Tek Glas TM g2

Analysis of Melamine and Cyanuric Acid in Food Matrices by LC-MS/MS

Retention Time Locking: Concepts and Applications. Application

Original Article. Simultaneous determination of androstenedione and testosterone in human serum by liquid chromatography-tandem mass spectrometry

Solutions for transcutaneous monitoring

Comparative analysis of mass spectral matching for confident compound identification using the Advanced Electron Ionization source for GC-MS

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

Gradients in ion chromatography. Optimal separation with shorter analysis time

EFFECTS OF REVIVOGEN SCALP THERAPY ON TESTOSTERONE METABOLISM IN RECONSTRUCTED HUMAN EPIDERMIS

Gas Chromatography-Mass Spectrometry Analysis Of Organics In Drinking Water: Concentrates And Advanced Waste Treatment Concentrates, Vol.

STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015

Application Note AN-107

Improved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL

Quantitative Assay Validation for Oxandrolone in Human Plasma Using LC MS-MS

EVALUATION OF PROFICIENCY TESTING PROGRAM, SETTING PRIORITIES FOR THE FUTURE.

Hiden QIC Series Gas Analysers Real-time gas analysis systems

One of the guarantees of quality: External Quality Control. Finlay MacKenzie

The Tekran Series 2600-IVS Difference!

Technical Procedure for Drug Chemistry Gas Chromatograph/Mass Spectrometry (GC-MS)

PHOENIX L300i Best-in-class Helium Leak Detectors

Triton DO8 Dissolved Oxygen Sensors ELECTRO-CHEMICAL DEVICES

Capillary Flow Porometer/Frazier/C-522 CFP-1100AEX-F-C522

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens.

Improving the Measurement Accuracy of Water Partial Pressure Using the Major Constituent Analyzer

ANZAI AZ-733VI. Respiratory Gating System. since 1976

GCMSD-Headspace Analysis SOP

EasyLine Continuous Gas Analyzers. So smart, they re simple

Introduction. Experimental

Research and Development. Money in the Pipeline

Chemical Analysis for Methyltestosterone

AmpFlSTR Identifiler PCR Amplification Kit

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user.

Extended Application Note

ISO INTERNATIONAL STANDARD

EFFECTS OF CLEAROGEN ACNE LOTION ON TESTOSTERONE METABOLISM IN RECONSTRUCTED HUMAN EPIDERMIS

ab Testosterone ELISA Kit

Advanced Test Equipment Rentals ATEC (2832) OMS 600

ISO INTERNATIONAL STANDARD

Practical approach and problems in in-situ RGA calibration

Transcription:

Now it is easy to switch to Clinical MSMS CHS TM Steroid Profiling kit and software Brochure not for distribution in the USA and Canada

2 Meeting your needs for steroid assays

PerkinElmer s new CHS MSMS Steroid Kit helps you to implement liquid chromatography tandem mass spectrometry (LC-MSMS) in your laboratory and hence to meet your present and future steroid assay needs. Improved specificity and sensitivity New LC-MSMS methods represent the most successful approach towards improving on the specificity attainable using immunoassays. As well as offering improved analytical performance, the CHS MSMS Steroid Kit also provides you with the opportunity to view the overall pattern of expression of steroids rather than relying on individual one-off tests. The CHS MSMS Steroid Kit supports major savings in time and costs. It is especially well suited for specimens with low concentrations and small volume. With such specimens, the thoroughly validated kit affords high sensitivity and specificity through analyte-specific calibration together with the ability to measure 10 steroid analytes in the same aliquot. Labor-saving informatics Tandem mass spectrometry generates increased amount of data. For use with its new kit, and to provide labor savings in data handling, PerkinElmer has developed its dedicated CHS Data Suite Software. 3

CHS TM MSMS Steroid Kit Simultaneous measurement of 10 steroid analytes PerkinElmer CHS MSMS Steroid Kit represents the latest generation in LC-MSMS products, offering superior limits of quantification. The kit is fast and easy to use, and requires no derivatization steps. Using a sample volume of only 100 µl, the multianalyte steroid profiling kit provides results for 10 analytes in the same assay: testosterone cortisol corticosterone dehydroepiandrosterone progesterone 4-androsten-3,17-dione 11-deoxycortisol dehydroepiandrosterone sulfate 17-alpha-hydroxyprogesterone aldosterone Determination of concentration profiles of these 10 steroids may aid in clinical recognition, diagnosis and treatment of disease affecting the adrenal glands, ovaries, testes, and placenta. 4

State-of-the-art product to give you confidence in your results The kit is thoroughly validated. With specialized calibrators, and analyte-specific internal standards with deuterium labels, it also provides the luxury of three levels of analyte-specific internal controls. Intensity, cps 2.7e5 2.6e5 2.4e5 2.2e5 2.0e5 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 8.0e4 6.0e4 4.0e4 2.0e4 0.0 8.06 9.11 10.04 10.63 12.91 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Time, min CHS MSMS Steroid Kit gives you reliable concentration profiles for 10 key steroids. From individual results to comprehensive profiles Numerous enzymes are involved in the biosynthetic pathway of steroids and steroid intermediates. Loss of function of certain enzymes can trigger large changes in the pattern of steroid expression. With tandem mass spectrometry and CHS products, you can see the overall pattern of expression of steroids rather than individually acquired steroid values. 5

Why laboratories are switching to LC-MSMS Today s endocrinology laboratories have higher expectations as to results accuracy and ease of assay performance. The gold standard method for meeting the highest expectations is highperformance liquid chromatography/tandem mass spectrometry (LC-MSMS). LC-MSMS combines the benefits of two complementary techniques. High performance liquid chromatography is used to fractionate the samples into individual analytes and tandem mass spectrometry is used to quantitate these analytes. The fractionation stage is a major factor in the method s excellent analytical specificity. It removes the ambiguity associated with mass spectrometry when the technique is used to analyze mixtures. MSMS Q1 Collision Cell Q2 Detector HPLC Precursor Ion Selection Precursor Ion Fragmentation Product Ion Selection Product Ion Detection HPLC separates compounds out on the basis of retention time. The MSMS process separates precursor ions on the basis of their mass to charge ratio (m/z), then following a fragmentation stage there is a further separation of the product ions, also by their m/z. 6

Dedicated informatics to ease the workload Tandem mass spectrometry is a multiplexing technology that generates large amounts of data up to 100 times more data than typical immunoassays. PerkinElmer s CHS Data Suite software is optimized for use with PerkinElmer s CHS MSMS Steroids Kit and is designed to ease the data management workload. CHS Data Suite is and easy to deploy and easy to use software package pre-configured according to the needs of the CHS Kit user and is installed on a standard Windows-based PC. The software helps implement major savings in labor, as you: Automatically highlight (flag) cutoff violations Evaluate QC performance and trends Analyze cutoffs. 7

For the better At PerkinElmer, we re working to improve the health and safety of people and their environment. From safer water to cleaner air to healthier babies, our solutions touch every part of your life. PerkinElmer CHS products are not available in the USA, Canada and other countries. For information on availability of PerkinElmer diagnostic products please contact your local representative. PerkinElmer, Inc. PerkinElmer Genetic Screening 940 Winter Street Center of Excellence Waltham, MA 02451 usa wallac Oy, PO Box 10 Phone: (800) 762-4000 or 20101 Turku, Finland (+1) 203-925-4602 Phone: + 358 2 2678 111 www.perkinelmer.com fax: + 358 2 2678 357 For a complete listing of our global offices, visit www.perkinelmer.com/contactus 2009 PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks depicted are the property of their respective holders or owners. PerkinElmer reserves the right to change this document at any time and disclaims liability for editorial, pictorial or typographical errors. 1244-9923-01, August 2009 Printed in Finland