Datasheet. Technical. 3M 6000 Series Reusable Half Masks. Main Features. Applications

Similar documents
Datasheet. Technical. 3M 6000 Series Full Face Masks. Main Features

Technical. Datasheet 3M Reusable Half Face Respirator 6000 Series. Main Features. Applications

Technical. Datasheet. 3M 6000 Series Reusable Full Face Masks. Applications. Product Description. Key Features

Technical. Datasheet 3M Reusable Half Face Respirator 7500 Series. Main Features. Applications

3M TM Full Face Respirator 6000 Series - Schematic

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower.

3M Occupational Health & Environmental Safety Division. Half and Full Face Masks. Exceptional quality. & unrivalled. comfort

Application Hazard Typical Protection Solvent-Based Paint** Anti-Fouling Paint Spraying / Grinding

3M Personal Safety Division 3M Supplied Air Respirator System S200+ Work. in a World of. Comfort. The Power To Protect Your World

8214/8514/07187 Respirator N95 Particulate

Class 1 Cartridges and Filters for use with Honeywell Twin Filter half and full-face masks We listened to you. Respiratory Protection

Phalanx Alpha Phalanx Beta and Ultra Elite

DATASHEET SUPPLIER ART.NO. STAXS. ART.NO. F M Aura respirator with shrouded valve 6 x 8 pcs per box STAXS ART.NR.

3M recommended for the aluminum industry and nuisance level acid gas relief* in non-oil environments User Instructions (Keep insert for reference)

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care

Maintenance Made Simple Fewer replacement parts and super-simple disassembly make cleaning and maintaining the 7000 Series easy.

low maintenance respirator

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

University of Alabama Office of Environmental Health and Safety. Respirator Protection Training

Nuisance level organic vapor relief* User Instructions (Keep insert for reference)

9000 SERIES FULL FACE RESPIRATORS

NIOSH CERTIFIED FEATURES DUAL APPLICATIONS SUITABLE FOR WELDING APPLICATIONS

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

3M Occupational Health and Environmental Safety Division. Options

A. APPLICATIONS 1. WARNING TO USER

8515/07189 Respirator. N95 Particulate 3M recommended for welding, brazing, metal pouring and cutting User Instructions (Keep insert for reference)

Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters

3M Personal Safety Division 3M HALF FACEPIECE REUSABLE RESPIRATORS

Respiratory Protection Program

Michael Pate Utah State University

3M Occupational Health & Environmental Safety Division. Maintenance Free Particulate Respirator. Workwell, stay. well

Respiratory Protection Program

Breathe easily. Weld safely. 3M Disposable and Reusable Respirators for Welding

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR PERSONS CONDUCTING A BUSINESS OR UNDERTAKING

BREATHE SAFELY: The Proper Use of Respiratory Protection

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR WORKERS

Respiratory Protection Training

3M Half and Full Facepiece Respirators. Unsurpassed comfort. Maximum versatility. 3Innovation

BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY

RESPIRATOR HALFMASK AIR-PURIFYING 7700 SERIES SILICONE HALF MASK CARRY BAG. features and benefits

"RESPIRATORY PROTECTION AND SAFETY"

3 Choosing the Right Respirator

Respiratory Protective Equipment

DREW UNIVERSITY RESPIRATORY PROTECTION PROGRAM DRAFT 06/11

Safety Best Practices Manual

9210/37021, 9211/37022* Particulate Respirator N95

3M Select Software United Kingdom and Ireland

USE INSTRUCTIONS SCOTT HEALTH AND SAFETY PROMASK 25 FULL FACEPIECE RESPIRATOR USE INSTRUCTIONS

Respiratory Protection Program

The Dräger X-plore Series

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres

Inhale, Exhale, Relax. [ Triple Safety with the Advantage Line]

Operating and Maintenance Instructions

North RU8500 Series Half Masks

Particulate Respirator N95

Respiratory Protection

PRODUCT NUMBER: Rd40 Aluminium Canister K2

VFlex 9105/9105S Particulate Respirator N95

8000 SERIES FACEPIECE ASSEMBLY FACEPIECE REPLACEMENT CARTRIDGES 1 ORGANIC VAPORS ACID GASES ORGANIC VAPORS/ ACID GASES AMMONIA/METHYLAMINE

D Lightweight Respiratory Protection

Respiratory Protection Programs Policy

Respiratory Protection for Producers

A. Evaluation of the written program

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

1000 Series. Quality. Superior Filter Media. SABS Quality Mark. Metal Nose Clip. Foldable. Made in South Africa. Comfort Valve. Usage: Application:

RESPIRATORY PROTECTION

8200/07023 Particulate Respirator N95

Section 3. Respiratory Protection Plan (SPPM 3.24)

Respiratory Protection For Pesticides

RESPIRATORY PROTECTION PROGRAM

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision

8210Plus/8210/07048/8110S Particulate Respirator 3M recommended for sanding, grinding, sawing, sweeping and insulating

Ontario Operations PMP - Daily Safety Message. Respirator Safety

Respirator with Ultra-Twin, Ultravue, Ultra Elite, or Duo-Twin TM Facepiece

Respiratory Protection

RESPIRATORY PROTECTION

San Mateo County Health System Environmental Health Services Division. Respirator Use

Respiratory Protection 3M Reusable Respirators. Engineered for. comfort and. durability

Respiratory Protection

The Following information is based on material prepared by the American Lung Association

PPE: RESPIRATORY PROTECTION EQUIPMENT

Respirator with Ultra-Twin, Ultravue, Ultra Elite, or Duo-Twin TM Facepiece

EP30g, Respiratory Protection.pdf

Personnel Protective Equipment

Standards of Practice Respiratory Protection: Appendix C

Respiratory Protection Self Inspection Checklist

Respiratory Protection Program

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

Vortex Tube Respirator

Disposable Particulate Respirators

Respiratory Protection Program 29CFR

PRODUCT NUMBER: A COMPACT AIR A150401

West Clinton Fire District

RESPIRATORY PROTECTION PROGRAM

Head Cover BE-12 Series

Dual Airline Supplied Air Respirators User Instructions

COLUMBUS STATE COMMUNITY COLLEGE EMPLOYEE SAFETY MANUAL

Transcription:

Technical Datasheet 3M 6000 Series Reusable Half Masks Main Features The 3M 6000 Series Reusable Half Masks are proven to be simple to handle and comfortable to the wearer. The new exhalation port provides increased durability, easy cleaning and reduced breathing resistance which helps to increase your comfort. Available in three sizes, all masks have the 3M bayonet connection system allowing connection to a broad range of twin lightweight fi lters to protect against gases, vapours and particulates depending on your individual needs. The main features include: Reusable, low maintenance half mask. Soft, lightweight elastomeric respirator ensures comfort during long periods of work. Flexible System (gas & vapour and / or particulate fi lters plus Supplied-Air option). Twin fi lter design provides lower breathing resist ance, a more balanced fi t, and improves fi eld of vision. Cost effective replacement fi lters. Safe, secure Bayonet fi lter attachment system. Easy and secure fi tting. 3 sizes (small - 6100, medium - 6200, large - 6300) Face piece weight: 82 grams. Applications The 6000 Series Respirators can be used with a variety of different fi lter options: Gas and Vapour Filters only: The fi lters generally protect against either single or multiple contaminant type(s). The 6000 Series filters fi t directly onto the respirator except for the 6098 and 6099. Particulate filters only: These fi lters provide protection against solid and non-volatile liquid particles. T he 2000 Series particulate fi lters fi t directly onto the respirator. T he 5000 Series particulate fi lters may be used on their own with platform 603 and 501 retainers. The 6035 & 6038 are encapsulated fi lters, which fi t directly onto the respirator. Combination of Gas & Vapour and Particulate filters: The 5000 Series particulate fi lters can be used with 6000 Series Gas and Vapour fi lters using 501 retainers excluding the 6035, 6038, 6096, 6098 and 6099. The 6096 has a Particulate fi lter media integrated with the Gas and Vapour cartridge. The 6038 is an encapsulated particulate fi lter with a layer of carbon for low capacity gas protection. Supplied-Air mode: All fi lters can be used with S-200 Supplied Air Regulator except for the P1 R (5911) and P2 R (5925, 2125 and 2128) fi lters, and 6098 and 6099. 6035 P3R 6038 P3R(HF) 2125 P2R 2128 P2R 2135 P3R 2138 P3R safe &quick 6051 A1 6055 A2 6054 K1 6057 ABE1 6059 ABEK1 6075 A1+Form 5911 P1R 5925 P2R 5935 P3R 501 Supplied-Air option click! 6096 A1HgP3R

Gas and Vapour Filters: FILTER IMAGE STANDARD CLASS HAZARD INDUSTRY 6051 (06911) 6055 (06915) A1 A2 Organic Vapours (b.pt. > 65 C) - Anywhere conventional paints are used (non-isocyanates, subject to usage conditions) - Vehicle manufacture - Aircraft manufacture and refurbishment - Boat Building - Ink and dye manufacture and use - Adhesive manufacture and use - Paint and varnish manufacture - Resin manufacture and use 6054 K1 Ammonia & derivatives - Manufacture and Maintenance of refrigeration equipment - Spraying and handling Agrochemicals 6057 ABE1 Combination organic vapours (b.pt. >65ºC), inorganic & acid gases As 6051, but including: - Electrolytic processes - Acid Cleaning - Metal Pickling - Metal Etching 6059 ABEK1 Combination organic vapours (b.pt. >65ºC), inorganic & acid gases & Ammonia As 6057 & 6054 6075 A1 + Formaldehyde Organic Vapours (b.pt. >65ºC) & Formaldehyde As 6051 but also: - Hospitals and Laboratories 6096 A1Hg Organic vapours (b.pt. >65ºC), Mercury vapour, Chlorine & Particulates - Use of Mercury & Chlorine - Particulate applications Particulate Filters: FI LT ER IM AG E S TA NDA RD C L A S S H A Z A RD INDUS T RY 5911 5925(06925) 5935 2125 2135 2128 2138 6035 6038 P1 P2 P3 P2 R P2 R Particulates, Ozone & nuisance levels of Organic Vapours & Acid Gases Particulates, Hydrogen Fluoride at 10 x TLV, Nuisance levels of Organic Vapours & Acid Gases - Welding - Paper Industry - Brewing - Chemical Processing - Typical Smog - Inks and Dyes As 6035 but also: - Aluminium smelting - Mining

Approvals The 3M 6000 Series Respirators and 6000/5000/2000 Series Filters have been shown to meet the Basic Safety Requirements under Article 10 and 11 of the European Community Directive 89/686/EEC, and are thus CE-marked. These products were examined at the design stage by: BSI Product Services, Kitemark House, Maylands Avenue, Hemel Hempstead, Herts, HP2 4SQ, England (Notifi ed Body 0086). Standards These products have been tested to the relevant European Standards: 6000 Series Half Masks to EN140: 1998. 6000 Series Gas and Vapour fi lters to EN14387:2004 + A1:2008 2000 and 5000 Series and 6035, 6038 Particulate fi lters to EN143: 2000 +. Correct Usage When the 6000 Series Half Mask is fitted with Gas & Vapour Filters: 6000 Series gas and vapour fi lters, it may be used in concentrations of gases or vapours (types specifi ed by 3M) up to 50 x the Threshold Limit Value (TLV) or 1000ppm (5000ppm for 6055) whichever value is lower. 6 075 offers protection against organic vapour (as above) and 10ppm formaldehyde only. 6000 Series gas and vapour fi lters should not be used to protect the wearer against a gas or vapour that has poor warning properties (smell or taste). When the 6000 Series Half Mask is fitted with Particulate Filters: 5911 fi lters may be used in concentrations of particulates up to 4 x TLV. 5925, 2125 or 2128 fi lters may be used in concentrations of particulates up to 12 x TLV. 5935, 2135, 2138 or 6035, 6038 fi lters may be used in concentrations of particulates up to 50 x TLV. 2128 and 2138 fi lters may be used to protect against ozone up to 10 x TLV and offers relief from acid gases and organic vapours at levels below the TLV. 6 03 8 offers protection against 10 x TLV Hydrogen Fluoride and offers relief from acid gases and organic vapours at levels below the TLV. Cleaning and Storage Cleaning is recommended after each use. 1. Disassemble by removing the fi lters, head straps and other parts. 2. Clean and sanitize the mask (excluding fi lters) using 3M 105 Face Seal Cleaner or immersing in warm cleaning solution and scrubbing with a soft brush until clean. Parts may also be cleaned in a domestic washer. 3. Disinfect respirator by soaking in a solution of quaternary ammonium disinfectant or sodium hypochlorite (30 ML household bleach in 7.5L of water) or other disinfectant. 4. Rinse in fresh, warm water and air-dry in noncontaminated atmospheres. Water temperature should not exceed 50 C. Do not use cleaning agents that contain lanolin or other oils. Do not autoclave.. Use Limitations 1. These respirators do not supply oxygen. Do not use in oxygen defi cient areas.* 2. Do not use for respiratory protection against atmospheric contaminants, which have poor warning properties, are unknown or immediately dangerous to life and health, or against chemicals, which generate high heats of reaction with chemical fi lters. (The 3M S-200 Supplied-Air Respirator System can be used against contaminants with poor warning properties, subject to other use limitations). 3. Do not modify or alter this device. 4. The assembled respirator may not provide a satisfactory face seal with certain physical characteristics (such as beards or large side burns) resulting in leakage between the respirator and the face. The user assumes all risks of bodily injury, which may possibly result. 5. Do not use with unknown concentrations of contaminants. 6. Do not use for escape purposes. 7. Leave the work area immediately and check the integrity of the respirator and replace respirator and / or fi lters if: Damage has occurred or is apparent. Breathing becomes diffi cult or increased breathing resistance occurs. Dizziness or other distress occurs. You taste or smell the contaminant or an irritation occurs. 8. Store this device in a sealed container away from contaminated areas when not in use. 9. Use strictly in accordance with respirator and fi lter user instruction leafl et. * 3M definition minimum 19.5% by volume oxygen

Fitting Instructions Before assigning any respirator to be worn in a contaminated area, we recommend that a qualitative or quantitative fi t check be performed before entering the workplace. Fitting instructions must be followed each time the respirator is worn. 1. Place the respirator over the mouth and nose, then pull the harness over the crown of the head. 2. Take the bottom straps in both hands, place them at the back of the neck and hook them together. 3. Tighten the top straps fi rst by pulling on ends to achieve a comfortable and secure fi t. 4. Tighten bottom straps using either front or rear adjustments. (Strap tension may be decreased by pushing out on back side of buckles). Fit Check Perform a positive and/or negative pressure fi t check each time the respirator is donned. Positive pressure Face Fit check (all Filters except 3M 6035, 6038 / 2000 Series Filters). 1. Place the palm of the hand over the exhalation valve cover and exhale gently. 2. If the respirator bulges slightly and no air leakage between the face and the respirator is detected, a proper fi t has been achieved. 3. If air leakage is detected, reposition the respirator on the face and/or readjust the tension of the strap to eliminate the leakage. 4. Repeat the above face fi t check. 5. If you cannot achieve a proper fi t, do not enter the contaminated area. See your supervisor. Negative pressure face fit check (3M 6035, 6038 / 2000 Series Filters) 1. Push the fi lter cover down (6035, 6038) or press your thumbs into the central indentation of the fi lters (2000 series), inhale gently and hold your breath for fi ve or ten seconds. 2. If the respirator collapses slightly, a proper fi t has been achieved. 3. If air leakage is detected, reposition the respirator on the face and/or readjust the tension of the straps to eliminate the leakage. 4. Repeat the above face fi t check. 5. If you cannot achieve a proper fi t, do not enter the contaminated area. See your supervisor. Materials PART MATERIAL Face Mask Thermoplastic Elastomer Head Harness Polyethylene Head Strap Polyester / cotton / Polyisoprene Inhalation Valve Polyisoprene Exhalation Valve Silicone Rubber Gasket Silicone Rubber 6000 Filter Body Polystryrene 6000 Filter Element Activated / Treated Carbon 5000 / 2000 Series Filter material Polypropylene

Spare parts PART MATERIAL 6895 Inhalation Gasket 501 Retainer for 5000 Series Filters 603 Particulate Filter Platform 105 Face Seal Cleaner S-200 Supplied Air Regulator 106 Half Mask Carry Case Respiratory Protection is only effective if it is correctly selected, fitted and worn throughout the time when the wearer is exposed to respiratory contaminants. 3M offers advice on the selection of products, and training in the correct fi tting and usage. For more information on 3M products and services please call the 3M Health & Safety Helpline. Important Notice 3M does not accept liability of any kind, be it direct or consequential (including, but not limited to, loss of profi ts, business and/or goodwill) arising from reliance upon any information herein provided by 3M. The user is responsible for determining the suitability of the products for their intended use. Nothing in this statement will be deemed to exclude or restrict 3M s liability for death or personal injury arising from its negligence. 3M Occupational Health & Safety Division EMEA Region 3 M C e n t r e C a i n R o a d B r a c k n e ll Berkshire RG12 8HT U n i t e d K i n g d o m Te l: +4 4 ( 0 ) 13 4 4 8 5 8 0 0 0 Web: www.3m.eu/safety Please recycle. 3M 2010. All rights reserved. EU_MASTER_01