Speed control assembly model A-1

Similar documents
TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Page 1 of 12

Anti-flood device Model B-1

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA CAUTION

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 256a. October 31, 2013

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

TECHNICAL DATA CAUTION

TECHNICAL DATA ACCELERATOR MODEL E-1

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

TECHNICAL DATA. Dry 132a. October 1, 2008

TECHNICAL DATA OBSOLETE

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA. Deluge Valves 211a. November 30, 2007 DELUGE VALVE MODEL E-1 ANGLE STYLE 3 (DN80), 4 (DN100) & 6 (DN150)

TECHNICAL DATA. Deluge Valves 218a. November 30, 2007 DELUGE VALVE MODEL F-1 STRAIGHT THROUGH STYLE 2-1/2 (DN65) - 8 (DN200)

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Table 1 - Specifications

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Trimpac 247a_Euro. September 16, 2013

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA OBSOLETE

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

OBSOLETE. Wet pipe low flow manifold system

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

TECHNICAL DATA OBSOLETE

Wet pipe low flow foam/water system

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

Combination Air Valve

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA. than the water inlet pressure to the concentrate

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

1805 Series Relief Valves

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

Services Department for information concerning the use of the ACC-1 for use with dry pipe valves other than the Model DPV-1.

V43 Pressure Actuated Water Regulating Valve

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

1305 Series Pressure Reducing Regulators

GENERAL DESCRIPTION MODEL RCW DRY SYSTEM CONFIGURATION. Technical Support Airpark Dr. Standish, MI 48658

Technical Data. UL Listing is based on the following criteria:

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Halsey Taylor Owners Manual STOP!

TECHNICAL DATA OBSOLETE

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

Bermad Pressure Reducing. Model: 42T

Installation, Operation, and Maintenance Manual

29 SERIES - SAFETY VALVE

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

DS06D,G Dial Set Pressure Regulating Valve

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.

DS05C,D,G Dial Set Pressure Regulating Valves

1200B2 Series Service Regulators. Instruction Manual

Booster Pump PB4-60 Replacement Kits

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

2.0 INSTALLATION & SERVICE

Operating Instructions Models and Hydrostatic Test Pumps

INSTALLATION OPERATION MAINTENANCE

D05 Pressure Regulating Valves

Operating Instructions Model and Hydrostatic Test Pump

Data Sheet Issue A

Instructions for Installation, Operation, Care and Maintenance

Operating Instructions Models and Hydrostatic Test Pumps

GM Series Dual-Block Multi-Function Gas Control Valves

Worldwide Contacts. General Description

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Pressure Dump Valve Service Kit for Series 2300 Units

Operating Instructions Models and Hydrostatic Test Pumps

Combination Air Valve Model

Pressure Regulator B-95

Instruction Manual Updated 7/26/2011 Ver. 2.2

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Operating Instructions Model and Hydrostatic Test Pump

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Operating Instructions Models and Hydrostatic Test Pumps

TECHNICAL DATA NOTICE

Operation Manual Piston Sensed Gas Pressure Regulators

Transcription:

Pressure Regulation 533a 1. DESCRIPTION The Viking Speed Control Assembly provides adjustment of the opening speed of Viking Deluge Valves, and adjustment of both the opening and closing speed of Viking Flow Control Valves. Water hammer, which may result from the opening of a Deluge Valve or opening and closing of a Flow Control Valve, may be reduced by adjusting opening and/or closing speed. Also, use of the Speed Control Assembly, along with the Viking Pilot Pressure Regulating Valve, enables pressure regulation for reducing high water supply (inlet) pressures to lower outlet pressures. The Speed Control Assembly is factory assembled for easy installation, and is listed for optional use with Viking Deluge and Flow Control Valves equipped with Conventional Trim. The Viking Speed Control Assembly is required when a Viking Flow Control Valve is equipped with a Viking Pilot Pressure Regulating Valve. 2. listings Listings and approvals: Approvals: UL Listed for use with UL Listed Viking Deluge Valves and Flow Control Valves equipped with Conventional Trim. UL Listed as a required component when UL Listed Viking Flow Control Valves are equipped with the Viking Pilot Pressure Regulating Valve. FM Approved - Deluge Sprinkler Systems, Pre-Action Sprinkler Systems, Refrigerated Area Sprinkler Systems, On-Off Multi Cycle Sprinkler Systems 3. Specifications: Water Working Pressure Rating: For use up to 250 PSI (17.2 bar) Material Standards: Refer to Chart in Figure 1 Ordering Information: Part Numbers: 08780 (Galvanized) or 11181 (Brass) Shipping Weight: Approximately 6.8 lbs (3.1 kg) Available since 1994 4. INSTALLATION Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. General Installation Instructions: The Viking Deluge Valve or Flow Control Valve used must be trimmed with Conventional Trim and installed in an area not subject to freezing temperatures or physical damage. When corrosive atmospheres and/or contaminated water supplies are present, it is the owner s responsibility to verify compatibility with the Valve, Trim, Speed Control Assembly, and associated equipment. For proper operation and approval, the Speed Control Assembly must be installed according to the appropriate Viking Deluge Valve or Flow Control Valve Trim Chart and Viking schematic drawings for the system being installed. Trim Charts are provided in the Speed Control Assembly Package. Both Trim Charts and schematic drawings are provided in the Viking Engineering and Design Data book. 1. Verify that the Viking Deluge Valve Trim or Flow Control Valve Trim used is Conventional Trim (Refer to Figure 2). If the trim has been installed, verify that it has been installed according to current trim charts. 2. Verify that the system is out of service and that the Deluge or Flow Control Valve Conventional Trim has been de-pressurized and properly drained. 3. On valves with trim installed, remove the pipe connecting the priming chamber to the trim by loosening the two unions provided. 4. Remove plastic thread protectors from the Speed Control Assembly. 5. Apply a small amount of pipe joint compound or tape to the external threads of all pipe connections required. Take care not to allow any compound, tape, or other foreign matter inside any of the nipples or openings of the Speed Control Assembly or other trim components. 6. Remove the union parts from the pipe removed in step 3 and install them on the 1/2 (15 mm) NPT nipples provided on the Speed Control Assembly. 7. Install the Speed Control Assembly as shown on the appropriate Viking Trim Chart provided in Figure 2. Form No. F_091794 Revised page replaces page 533a-d dated November 30, 2007. (Revised drawings and the Replacement Parts list. Removed stainless steel part number 11192.)

Pressure Regulation 533b Hydrostatic Test: Caution: When a Pressure Operated Relief Valve (PORV) is installed in the Deluge or Flow Control Valve trim, DO NOT subject the PORV to a 200 psi (13.8 bar) hydrostatic system test unless the 1/2 trim piping connecting the outlet chamber of the Deluge or Flow Control Valve to the operating (single ported) end of the PORV is disconnected and plugged during the test. Remove the plugs and re-connect the piping before placing the system in service. 4-A. PLACING IN SERVICE A: PROCEDURE FOR DELUGE VALVES: 1. Adjust Speed Control to initial setting for Deluge Valves: a. Fully OPEN the needle valve controlling flow into the priming chamber. This needle valve is marked SLOW CLOSE. b. Fully CLOSE the needle valve controlling flow out of the priming chamber. (This needle valve is marked SLOW OPEN.) Then partially open it, turning it approximately one and one-half turn counter-clockwise. 2. Place the system in service according to instructions printed in current Technical Data for the Viking Deluge Valve used. 3. Perform Trip Test to test the Deluge Valve opening speed with initial settings as described in step 1. (Opening the Emergency Release will trip the system.) Caution: Performing a trip test results in operation of the Deluge Valve. Water will flow into the sprinkler piping and out of any open sprinklers. Take necessary precautions to prevent damage. a. Observe the time required for the Deluge Valve to open. 4. Reset the Deluge Valve according to instructions printed in current Technical Data for the Valve used. 5. Adjustment procedure for Deluge Valves: a. If the opening speed observed in step 3 was too fast, turn the needle valve marked SLOW OPEN clockwise. Note: Needle valves are modified to prevent complete closure. Fully closing the needle valves will not prevent the Deluge Valve from operating. b. If the opening speed was too slow, turn the needle valve marked SLOW OPEN counter-clockwise. 6. Repeat steps 3 through 5 until the desired operating speed is achieved. b: PROCEDURE FOR FLOW CONTROL VALVES: 1. Adjust Speed Control to initial setting for Flow Control Valves: a. Fully CLOSE BOTH needle valves, then partially open them, turning both approximately one and one-half turns counterclockwise. 2. Place the system in service according to instructions printed in current Technical Data for the Viking Flow Control Valve used. 3. Perform Trip Test to test the Flow Control Valve operating speed with initial settings as described in step 1. Caution: Performing a trip test results in operation of the Flow Control Valve. Water will flow into the sprinkler piping and out of any open sprinklers. Take necessary precautions to prevent damage. a. Observe the time required for the Flow Control Valve to open. 4. Reset the Releasing Device used to trip the system. a. Observe the time required for the Flow Control Valve to reset. 5. Adjustment procedure for Flow Control: a. If the opening speed observed in step 3 was too fast, turn the needle valve marked SLOW OPEN clockwise. Note: Needle valves are modified to prevent complete closure. Fully closing the needle valves will not prevent the Flow Control Valve from operating. b. If the opening speed was too slow, turn the needle valve marked SLOW OPEN counterclockwise. c. If the closing (resetting) speed observed in step 3 was too fast, turn the needle valve marked SLOW CLOSE clockwise. d. If the closing (resetting) speed was too slow, turn the needle valve marked SLOW CLOSE counterclockwise. 6. Repeat steps 3 through 5 until the desired operating speed is achieved. 5. OPERATION (Refer to Figure 1.) The Viking Model A-1 Speed Control Assembly consists of a pre-assembled galvanized or brass pipe loop for installation between the priming chamber and trim of the Viking Deluge or Flow Control Valve used. One leg of the loop is equipped with a check valve to allow flow into the priming chamber only. The other leg is equipped with a check valve that only allows flow out of the priming chamber.

Pressure Regulation 533c Both legs are equipped with a special needle valve to adjust flow into or out of the priming chamber. The needle valves are modified to prevent complete closure, thus ensuring that fully closing the needle valves will not prevent the Deluge Valve or Flow Control Valve from operating. An additional strainer is provided in the outlet leg of the assembly to prevent the possibility of contaminants entering release line devices. With both needle valves fully opened, flow into the priming chamber will allow the valve to set at maximum speed and flow out of the priming chamber will allow the valve to trip at maximum speed. By partially or fully closing the appropriate needle valve, the setting and/or tripping speed can be reduced. 6. INSPECTIONS, TESTS, and MAINTENANCE After installation, the Speed Control Assembly is considered a trim component of the Valve on which it is installed. Refer to Maintenance instructions provided in Technical Data for the Valve used. Observe and apply all notices, warnings, cautions, and recommended procedures pertaining to trim components for the Valve used. Perform all recommended inspections, testing, and maintenance procedures on a regular basis; at least as often as the minimum frequencies recommended in Technical Data for the Valve used. Strainer Maintenance Procedures: (Refer to Figure 1.) Note: Flushing of strainer may be performed after the Deluge Valve or Flow Control Valve has operated. If the system is in operation when the strainer flushing plug is removed, water will flow from the opening. 1. To prevent operation of the Deluge Valve or Flow Control Valve, verify that the Main Water Supply Control Valve is closed. 2. Close the priming valve. 3. The Speed Control Assembly and associated trim may be de-pressurized by temporarily opening the Emergency Release. 4. To Flush Strainer Screen: a. Use the appropriate wrench to remove strainer flushing plug. Caution: Plug and trim may be pressurized. b. Open priming valve. Allow water to flow from the opening until it appears clear and free of debris. c. Close the priming valve. d. Re-install the flushing plug. 5. To remove strainer screen for inspection and cleaning: a. Use the appropriate wrench to loosen and remove the brass hex bushing and sealing washer. b. The strainer screen can be removed for inspection. Caution: Hex bushing and trim may be pressurized. c. Flush the screen with fresh water until clean. d. Place metal sealing washer over threads of hex-bushing. e. Carefully insert the screen into the seat provided in hex bushing. f. Install the hex bushing with screen. Use the appropriate wrench. Do not over-tighten. 6. When strainer maintenance is complete, place the system in service according to instructions printed in current Technical Data for the Viking Flow Control Valve used. a. Verify that the Main Water Supply Control Valve and priming valve are open. 7. AVAILABILITY The Viking Speed Control Assembly is available through a network of domestic and international distributors. See the Viking Corp. Web site for closest distributor or contact The Viking Corporation. 8. GUARANTEES For details of warranty, refer to Viking s current list price schedule or contact Viking directly.

Pressure Regulation 533d Figure 1 - Replacement Parts ITEM PART NUMBER MATERIAL NO. DESCRIPTION NO. Galvanized Brass Galvanized BRASS REQ D 1 01488A 01488A 1/4 Strainer Bronze and Stainless Steel Bronze 1 2 -- -- 1/2 x 1/2 x 1/4 Tee Galvanized Steel Brass 1 3 -- -- 1/2 x 1-1/2 Nipple Galvanized Steel Brass 2 4 06613A 03945A 1/2 Check Valve Brass Brass 1 5 -- -- 1/2 x Clo. Nipple Galvanized Steel Brass 6 6 * * 1/2 Releasing Speed Control Needle Valve Bronze Bronze 2 7 * * Label, Slow Close Aluminum, Silk Aluminum, Silk Screened Screened 1 8 -- -- 1/2 x 1/2 x 1/2 Tee Galvanized Steel Brass 1 9 -- -- 1/2 Union Galvanized Steel Brass 1 10 -- -- 1/2 x 1/4 x 1/2 Tee Galvanized Steel Brass 1 11 * * Label, Slow Open Aluminum, Silk Aluminum, Silk Screened Screened 12 -- -- 1/2 x 1/4 Hex Bushing Galvanized Steel Brass 1 13 -- -- 1/4 x Clo. Nipple Galvanized Steel Brass 3 14 -- -- 1/4 x 90 Ell Galvanized Steel Brass 1 15 08431 08431 1/2 In-line Check Valve Bronze Bronze 1 16 -- -- 1/4 Pipe Plug Brass Brass 1 17 -- -- Cap, Thread 2 18 -- -- 1/2 x 2 Nipple Galvanized Steel Brass 1 --Indicates replacement part not available * Indicates replacement part only available in Sub-Assembly below Sub-Assembly 6, 7, 11 08791 08791 Replacement Needle Package

Pressure Regulation 533e The Viking Speed Control Assembly may be used on Viking Angle Style Deluge or Flow Control Valves equipped with Conventional Trim installed according to the current conventional trim chart for the valve used. For Releasing Devices and modular trim, refer to current Technical Data for the releasing device used. Viking Deluge Valves, Flow Control Valves, Conventional Trim Packages, Releasing Devices and the Speed Control Assembly must be ordered separately. Figure 2

this page intentionally left blank Form No. F_091794 Revised page replaces page 533a-d dated November 30, 2007. (Revised drawings and the Replacement Parts list. Removed stainless steel part number 11192.)