The New Quintix. Redefining Standard.

Similar documents
The New Secura : Easy, Reliable Weighing in Regulated Areas

Pneumatic high-pressure controller Model CPC7000

User Manual. Portable Balances PL-E

KERN EG/EW Version /02

Pneumatic high-pressure controller Model CPC7000

Eclipse Precision & Analytical Balances

Hand-held pressure calibrator with integrated pump Model CPH6600

Sartorius CCL kg Prototype Mass Comparator

Technical Information Conducal CLY421

628 Differential Pressure Decay Leak Tester

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

User Manual. Precision and Analytical Balances ME-T

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

RADWAG Mass Comparators - ETERMA 2013 MASS COMPARATORS

Sartorius Basic plus Service Manual. WBP5007-e95021

Service Manual. Sartorius Expert. LE-Models Electronic Analytical and Precision Balances. WLE5001-e04022

Digital deadweight tester Model CPD8500

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

UniBloc technology and over 80 years of experience in precision weighing. Registered

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

KERN CM Version /2004

Additel 761 Automated Pressure Calibrators Selection Guide

Digital dead-weight tester Model CPD8500

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Additel 761 Automated Pressure Calibrators

ADT 761 Automated Pressure Calibrator

Precision digital pressure gauge Model CPG1000

Additel 780 Series Pressure Controller

Over 80 years of experience in precision weighing and UniBloc technology

Additel 761 Automated Pressure Calibrators Selection Guide

High-performance submersible pressure transmitter For level measurement Model LH-20

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

Additel 761 Automated Pressure Calibrators

High-performance submersible pressure transmitter For level measurement Model LH-20

Sartorius Competence CP Series Sartorius Gem plus

Additel 761 Automated Pressure Calibrators

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

English. Quick Guide MS-TS Precision and Analytical Balances

Precision pressure sensor Basic version Model CPT6020

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

Operation Instruction. BSM Series Electronic Precision Balances

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

AUW-D AUW AUX AUYSeries

General Accreditation Guidance. User checks and maintenance of laboratory balances

High-performance submersible pressure transmitter For level measurement Model LH-20

CO2 incubator with additional process controls

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

CO2 incubator with additional process controls

Additel 780 Series Pressure Controller

NEW: CO2 incubator with sterilizable sensor

High-performance submersible pressure transmitter For level measurement Model LH-10

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

NEW: CO2 incubator with sterilizable sensor

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs

High-performance submersible pressure transmitter For level measurement Model LH-10

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

EPP4 Pressure Regulator Basic G 1/4"

Guide No. 2/2009. Design, training and equipment Martin Firlus. Physikalisch Technische Bundesanstalt Braunschweig und Berlin

Industrial pressure controller Model CPC4000

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

FAS-W. Features. Applications. Automatic condensation hygrometer

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

SAUTER FK Version /2016 GB

Qi Litre Ultrasonic Cleaner

Volume Determination for 2 kg~20 kg in NIM

How to Achieve Optimal Weighing Performance

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

User Manual PTW-DensiX. D / Di/Zi

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Gas density monitor With integrated transmitter Model GDM-100-TI

Industrial pressure controller Model CPC4000

Additel 780 Series Pressure Controller

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE

Digital pressure gauge Model CPG500

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

BCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)

DFX II Series. Digital Force Gauge

Digital Melting Point Apparatus

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

PHOENIX L300i Best-in-class Helium Leak Detectors

Oil Diagnostic Systems. Online and bottle measurement Mobile and stationary operation Lab quality accuracy e

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

AXIS. User Manual. American Weigh Scales. AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g)

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

JUMO dtrans p30 Pressure Transmitter

STANDARD OPERATING PROCEDURE

Digital pressure gauge Model CPG500

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

VLT 2000 Series. How to size your VLT

Pressure transmitter PASCAL Ci4

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Transcription:

The New Quintix. Redefining Standard.

We found it really simple to use the new Quintix right away. I don t know of any other balance that is this easy to operate intuitively.

The new Sartorius Quintix sets new benchmarks in every aspect for standard lab balances: features, technology, ergonomic style, and, above all, the entirely new, user-friendly operating design of the Quintix that helps make workflows much more efficient. What it boils down to is the Quintix is fail-safe: it rules out weighing errors due to incorrect operation and eliminates the time-consuming chore of fine-tuning the settings. Fractions of a second are all it takes for any user to adapt the Quintix to specific requirements and obtain traceable results much faster than ever. Sartorius teamed up with experienced lab users to develop the user interface of the new Quintix. Lab users No. 1 priority was to ensure easy, intuitive operation without having read the manual first. They did it! The self-explanatory icons and plain-text prompts on the large touch screen show you all the information you need to know for the procedure no more, no less. For example, the touch-activated print key will appear only when Quintix has detected that a Sartorius printer is connected. The Quintix also excels in compliance with workplace safety requirements: Even if you are wearing several pairs of lab gloves, you can still correctly use all the functions of the balance.

Checkweighing Helps you zip through series of samples when you have to quickly determine whether each one is within a specific tolerance range. Density Takes the effort out of determining the density of a solid, irregularly-shaped object. Weighing In addition to this app, all Quintix balances feature isocal, the fully automatic internal calibration and adjustment function engineered by Sartorius to ensure total accuracy. Quintix comes standard with convenient, built-in applications. These, along with the extensive accessories Sartorius offers, enable you to customize Quintix to a variety of weight measurement tasks. Take specific gravity. With the built-in Density application and the Sartorius Density Kit, you can effortlessly determine the density of solids and liquids. Mixing Enables you to weigh in various components of a formula quickly with 100% traceability. Components Conveniently lets you weigh components of a formula into separate containers and retrieve the total amount weighed-in at any time. Statistics Saves you work when you need to know the standard deviation and other statistics on an entire group of different samples, but don t have the time to do the number-crunching yourself. Conversion Takes care of the math when you need to convert a weight using a factor, say, to calculate the weight per unit area. Peak Hold Locks in the reading so you can later view the maximum force released in milliseconds when a switch is activated during an experiment, or the weight of a bulky sample that hides the display while weighing. Unstable Conditions Delivers rock-steady results when you have to weigh in an extremely unstable environment or measure the weight of a hyper little mouse that just won t sit still. Percentage Makes comparisons of samples easy when you need to determine their difference in percent from a reference standard. Counting Gives you the exact count when you want to know how many identical parts, such as tablets, are in a bag.

With the apps in Quintix, we can now take care of exotic applications much more easily and efficiently.

I just transfer weights and other app data directly into an Excel file at a mouse click, without any additional software or bothering with tweaking this really couldn t be more convenient.

needing the settings Every advanced analytical laboratory requires GLP- GMPcompliant records, as well as fast and secure processing of the data generated. The Plug and Work technology in Quintix saves you considerable time and effort in generating fast and reliable documents. Quintix substantially simplifies processing data in spreadsheets. How? After connecting the USB port on Quintix to a computer, just open the Microsoft Office program you need. Quintix delivers data in your choice of format, either text or numbers, enabling effortless and accurate spreadsheet calculations. No additional software or special configuration settings are needed. The Sartorius standard printer YDP0 is automatically detected by Quintix. Thanks to interactive user guidance, Quintix provides help in generating error-free printouts, for instance, by inputting the correct sample ID numbers.

We use Quintix non-stop. It s worth its weight in gold because it s a balance you can always depend on.

Repeatable results and linearity are the key prerequisites to obtaining accurate and traceable weighing results. That s why Quintix has been subjected to extensive automated repeatability, linearity and temperature drift tests to guarantee that it meets our high metrological specifications. Inside a virtual rigorous testing chamber, Quintix test samples undergo more than 1,000,000 load stress tests to ensure that after years of standing up to the rigours of daily use with different weight loads, it will still deliver accurate results just like it did on day one. Quintix is crafted in Germany with high-grade components and materials. For example, the weigh cells are mounted on a solid, special aluminum alloy base plate, which is extremely impervious to ambient conditions, such as temperature fluctuations and vibration. All these tests and features add up to user benefits like the legendary reliability of the Sartorius Quintix, a major advantage it shares with every other Sartorius balance. Is the linearity still correct even after 1 million cycles? Absolutely! Shown here is the Quintix undergoing an endurance test.

Peace of Mind with isocal iso CAL iso CAL iso CAL Temperature fluctuations have an influence on the accuracy of your weighing results Target This is why every Quintix comes equipped with the internal adjustment function isocal that ensures consistently accurate results. Drift in the readout caused by fluctuations in the ambient conditions, such as temperature Each time isocal is performed, the Cal Audit Trail function in Quintix records all data on this procedure so it can be traced for your quality assurance. Designs Design Design 3 Design 1

Technical Specifications Model 1 513 313 13 510 310 10 110 1 5101 5100 Design 1 1 3 3 3 3 3 3 3 Weighing capacity g 0 10 510 310 10 5,100 3,100,100 1,100 10 5,100 5,100 Readability mg 0.1 0.1 1 1 1 10 10 10 10 10 100 1000 Repeatability mg 0.1 0.1 1 1 1 10 10 10 10 10 100 500 Linearity mg 0. 0. 0 0 0 0 0 300 1000 Typical s 3 1.5 1.5 1.5 1.5 1.5 response time Pan size diameter Height of the weighing chamber mm inches 90 3.5 90 3.5 10.7 10.7 10.7 180 7 mm 09 09 09 09 09 - - - - - - - Net weight kg.9.9.9.9.9 5. 5..7.7.7.7.7 lb 10.8 10.8 10.8 10.8 10.8 11.5 11.5 10.8 10.8 10.8 10.8 10.8 Dimensions mm 30 + 1 + 30 (designs 1+) 30 + 1 + 95 (design 3) D + W + H inches 1.1 + 8.5 + 1. (designs 1+) 1.1 + 8.5 + 3.75 (design 3) Versions verified All models can be obtained with an EC type-approval certificate for use in legal metrology as legal for trade Draft shield for analytical balances (Designs 1+) Housing Weigh cell Calibration Interface Supervisor lock In-use cover Anti-theft device Built-in application programs Below-balance weighing Accessories Development and manufacture Analytical draft shield chamber with doors that glide open smoothly for fatigue-free weighing Interior chamber featuring spill-proof design; exceptionally easy to clean All panes can be individually cleaned or exchanged 180 7 180 7 180 7 Chemically resistant finish of the housing for the easiest cleaning ever Sartorius weigh cell Mounted on a heavy-duty die-cast plate made of a special aluminum alloy Stable and repeatable weighing results guaranteed, along with minimum dependence on temperature 180 7 isocal fully automatic, temperature- and time-controlled internal adjustment mini USB Automatic recognition of Sartorius printer models YDP30 or YDP0 Direct data transfer to Microsoft Windows programs without any additional software Programmable interval for data output Choice of SBI, xbpi, table format or text format data transfer protocols Menu lock for protection against unintentional changes Provides added protection against dirt and scratches; supplied standard with the balance Kensington lock and lug for attaching a chain or a cable Special lab applications such as Mixing, Components, Statistics and Conversion; plus standard lab applications such as Weighing, Density, Percentage, Checkweighing, Peak Hold, Counting and Unstable Conditions Standard, built-in feature See Quintix list of accessories Developed and made in Germany 180 7 180 7

The New Quintix Redefining Standard. Intuitive application guideance Laboratory Balances Maximum accuracy at all time Easy cleaning Plug & Work connectivity to printer or computer AC Adapter Sartorius AC adaptor module 971790 with interchangeable country-specific plug-in AC adaptors Primary 100 0 V~, 10% +10%, 50 0 Hz, 0. A Secondary 15 V DC, ± 5%, 530 ma (max.) 8 Watt (max.): 0 to +0 C and 15 V DC, ± 5%, 330 ma (max.) 5 Watt (max.): 0 to +50 C Other data protection class II, in accordance with EN IEC 0950-1 up to 3000 m above sea level; IP0 as per EN IEC 059 Balance Power supply only via Sartorius AC adaptor module 971790 Input voltage 1.0... 18.0 V DC Power consumption W (typically) Ambient Conditions The specifications apply when the following ambient conditions are in place: Environment for indoor use only Ambient temperature * +10 C to +30 C Operational capacity guaranteed between +5 C and +5 C Storage and shipping 10 C to +0 C Elevation up to 3000 m above sea level Relative humidity** 15% to 80% for temperatures up to 31 C; non-condensing, decreasing linearly to 50% relative humidity at 0 C and 0% at 50 C Safety of electrical equipment Electromagnetic compatibility Defined immunity to interference Interference emission in accordance with EN 1010-1/IEC 1010-1. Safety requirements for electrical equipment for mea surement, control, and laboratory use Part 1: General requirements in accordance with EN 13-1/IEC 13-1. Electrical equipment for measurement, control, and laboratory use EMC requirements - Part 1: General requirements Suitable for use in industrial areas Class B (suitable for use in residential areas and areas that are connected to a low voltage network that also supplies residential buildings). The device can therefore be used in both areas. Balances verified for use in legal metrology comply with the requirements of Council Directive 009/3/EC, EN 5501:199, and OIML R7:00. * For balances verified for use in legal metrology in accordance with EU requirements, refer to the information on the balance. ** For balances verified for use in legal metrology in accordance with EU requirements, the legal regulations apply.

Technical Specifications Standard Equipment Levelling Calibration Selectable weight units 1 Interface Display Standard built-in applications Special built-in lab applications Languages Protection Password protection Anti-theft lock Underfloor weighing Glass level indicator with air bubble for centering Internal calibration isocal, External calibration Gram, kilogram, carat, pound, ounce, troy ounce, Hong Kong tael, Singapore tael, Taiwan tael, grain, pennyweights, milligram, parts per pound, China tael, mommes, Austrian carat, tola, baht, mesghal and Newton mini USB Automatic recognition of Sartorius printer models YDP30 or YDP0 Direct data transfer to Microsoft Windows programs Programmable interval for data output Data transfer protocols SBI, xbpi, table format, text format Touch screen with Sartorius graphical user interface optimized for users in pharmaceutical laboratories Weighing, Density, Percentage, Checkweighing, Peak Hold, Counting, Unstable Conditions Mixing, Components, Statistics, Conversion English, German, French, Spanish, Italian, Russian, Chinese, Polish, Japanese, Portuguese Chemical resistant finish of the housing In-use cover Dust cover for analytical balances Supervisor lock for protection against unintentional changes Kensington lock and lockdown capability for cable or chain Integrated 1 Limited for verified models

Analytical Balances Quintix Model 1 Weighing capacity g 0 10 Readability mg 0.1 0.1 Repeatability (standard deviation) mg 0.1 0.1 Linearity deviation mg 0. 0. Sensitivity drift between +10 C and +30 C ± ppm/k 1.5 1.5 Typical stabilization time s 3 isocal: Temperature change Time interval Display result (depending on the set filter level) s 0. 0. Weighing pan size mm d 90 d 90 Weighing chamber height mm 09 09 Net weight, approx. kg.9.9 Dimensions, D + W + H mm Inch 30 + 1 + 30 1.1 + 8.5 + 1. Precision Balances Quintix Model 513 313 13 510 310 10 110 1 5101 5100 Weighing capacity g 510 310 10 5100 3100 100 1100 10 5100 5100 Readability mg 1 1 1 10 10 10 10 10 100 1000 Repeatability (standard mg 1 1 1 10 10 10 10 10 100 500 deviation) Linearity deviation mg 0 0 30 30 30 300 1000 Sensitivity drift between ± ppm/k 3 3 3 3 3 5 5 5 10 10 +10 C and +30 C Typical stabilization time s 1.5 1.5 1.5 1.5 1.5 isocal: Temperature change Time interval Display result (depending on the set filter level) K h 1 1 K h 1 s 0.1 0. 0.1 0. 0.1 0. 0.1 0. 0.1 0. 0.1 0. 0.1 0. 0.1 0. 0.1 0. 0.1 0. Weighing pan size mm d 10 d 10 d 10 d 180 d 180 d 180 d 180 d 180 d 180 d 180 Weighing chamber height mm 09 09 09 Net weight, approx. kg.9.9.9 5. 5..7.7.7.7.7 Dimensions, D + W + H mm Inch 30 + 1 + 30 1.1 + 8.5 + 1. 30 + 1 + 95 1.1 + 8.5 + 3.75 1.5 1 1.5

Verified Models with Country-specific Type Approval Certificate Analytical Balances Quintix Model -1x 1 1-1x 1 Accuracy class k k Type SQP-A SQP-A Max g 0 10 Scale interval d mg 0.1 0.1 Verification scale interval e mg 1 1 Min mg 10 10 Tare (subtractive) <100 % of the max. weighing capacity Typical stabilization time s 3 isocal: Temperature change Time interval K h Display result (depending on the set filter level) s 0. 0. Weighing pan size mm d 90 d 90 Weighing chamber height mm 09 09 Net weight, approx. kg.9.9 Dimensions, D + W + H Precision Balances Quintix mm Inch 1.5 30 + 1 + 30 1.1 + 8.5 + 1. Model 513-1x 1 313-1x 1 13-1x 1 510-1x 1 310-1x 1 10-1x 1 110-1x 1-1x 1 5101-1x 1 5100-1x 1 Accuracy class Type SQP-B SQP-B SQP-B SQP-C SQP-C SQP-D SQP-D SQP-D SQP-E SQP-E Max g 510 310 10 5100 3100 100 1100 10 5100 5100 Scale interval d mg 1 1 1 10 10 10 10 10 100 1000 Verification scale mg 10 10 10 100 100 100 100 100 1000 1000 interval e Min g 0.0 0.0 0.0 0.5 0.5 0.5 0.5 0.5 5 50 Tare (subtractive) < 100 % of the max. weighing capacity Typical stabilization s 1.5 1.5 1.5 1.5 1.5 time isocal: Temperature change Time interval K h Display result (depending on the set filter level) s 0.1 0. 0.1 0. 0.1 0. 0.1 0. 0.1 0. 0.1 0. 0.1 0. 0.1 0. 0.1 0. 0.1 0. Weighing pan size mm d 10 d 10 d 10 d 180 d 180 d 180 d 180 d 180 d 180 d 180 Weighing chamber height mm 09 09 09 Net weight, approx. kg.9.9.9 5. 5..7.7.7.7.7 Dimensions, D + W + H mm Inch 30 + 1 + 30 1.1 + 8.5 + 1. 30 + 1 + 95 1.1 + 8.5 + 3.75 1.5 1 Possible terms for country-specific models: x = CEU: Verified balances with EC Type Approval Certificate D1-09-01 (for EU except France, Italy, and Switzerland) x = CFR: Verified balances with EC Type Approval Certificate D1-09-01 for France only x = CIT: Verified balances with EC Type Approval Certificate D1-09-01 for Italy only x = CCH: Verified balances with EC Type Approval Certificate D1-09-01 for Switzerland only x = NUS: NTEP Certificate for USA x = CN: CMC Type Approval Certificate for China x = 0JP: Balance with Type Approval Certificate for Japan x = 0BR: Balance with Type Approval Certificate for Brazil x = 0AR: Balance with Type Approval Certificate for Argentina x = 0KR: Balance with Type Approval Certificate for South Korea x = 0RU: Balance with Type Approval Certificate for Russia x = 0IN: Balance with Type Approval Certificate for India x = 0CA: Balance with Type Approval Certificate for Canada All models with...cn : type SQP

Optional Accessories Printers and Communications Premium GLP Laboratory Printer Printer paper for GLP laboratory printer Endless labels for GLP laboratory printer Standard Laboratory Printer Printer paper for standard laboratory printer Data Cable Mini USB USB A Date Cable Mini USB RS3 9-pin General Battery Pack for Standard Lab Balances Draft Shield for analytical balances In-use cover for analytical balances In-use cover for precision balances Dust cover for analytical balances with draft shield Density Determination Density kit for analytical balances Density kit for precision balances for lab balance model 10; 110; 1 Calibration Weights Calibration for lab balance model 1 Proof Line knob weight 100 g, OIML class E, with DAkkS certificate Calibration for lab balance model ; 313; 13 Proof Line knob weight 00 g, OIML class E, with DAkkS certificate Calibration for lab balance model 513; 1 Proof Line knob weight 500 g, OIML class E, with DAkkS certificate Calibration for lab balance model 110 Proof Line knob weight 1 kg, OIML class E, with DAkkS certificate Calibration for lab balance model 310; 10 Proof Line knob weight kg, OIML class E, with DAkkS certificate Calibration for lab balance model 510; 5101; 5100 Proof Line knob weight 5 kg, OIML class E, with DAkkS certificate YDP30 9Y0385 9Y038 YDP0 9Y0387 YCC0-D09 YCC03-D09 YRB11Z YDS01SQP 90SE01 90SE0 90SE03 YDK03 YDK0 YCW51-AC-0 YCW5-AC-0 YCW55-AC-0 YCW1-AC-0 YCW-AC-0 YCW5-AC-0 YDP0, Standard Laboratory Printer

Technical Drawings Models with a readability of 0.1 mg, in mm Models with a readability of 1 mg, in mm

Models with a readability of > 10 mg, in mm Distributed by: BIRKENSTOCK & CO. GMBH 1500 Geesthacht Germany Tel. +9 15 80980 Fax +9 15 8099 www.beco-technic.com Technical changes as well as changes in production and prices are subject to our approval. For our terms of delivery and payment please go to www.beco-technic.com. Reg. office: 1500 Geesthacht Germany Register Court: Lübeck HRB 31 GE Managing Directors: Jürgen Birkenstock, Marek Birkenstock VAT-Number: DE 13583788 ILN 0 739 00000 3 WEEE-Reg.-Nr. DE1990100