Service Installation: 48 V Power Supply September 27, 2018 SI Written by BTA

Similar documents
Preferred Instruments Danbury, CT USA

Miniature controls. Contactors. Overload relays. Starters. Control relays

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

! Warning, refer to accompanying documents.

INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK

OC Panel High Limit Aquastat Kit, Manual Reset p/n

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

RPS900W Redundant Power Supply. Installation Guide.

Stand-Alone Bubble Detection System

Gerber Sabre 404 and 408 Installation Instructions

Pachinko Game (Additional Information)

Roller AC Servo System

When your Rock-N-Bowl was shipped from the factory, the dipswitches were set as follows:

FX134, FX1234, FX3030 Problem and Solutions

Wickets Installation Laundry Equipment Specific Installation Instructions 5/22/2009

CircuFlow Quick Setup Guide

How to calibrate the formaldehyde sensor within a PPMonitor Wireless Unit:

Coastal Amusements 1935 Swarthmore Ave. Lakewood NJ Tel: (732) Fax: (732)

Inoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development.

700 SERIES BMS II BUBBLER MONITORING SYSTEM

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

Troubleshooting Guide How to Properly Diagnose a Water Valve: Single, Triple, and Quadruple Solenoid Valves

Quadair. Air Hockey Table Owners Manual. Assembly operation and care instuctions. Serial # Distributed By. Sales Person. Technical Service #

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

FAULT CODE TROUBLESHOOTING INDEX

Pressure Dump Valve Service Kit for Series 2300 Units

A4s Operation Manual

T-02b2: Set Up/Adjust Drive (DC Full Range GE-Valutr

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Model TX-FM/FN Sensor Head

PURA. Pure Gas Dewpoint Transmitter. Users Guide

TECH TIPS TZ34/20 & TZ50/30. Service Call: Machine will not automatically level. Tools Needed: Multi Meter Jumper wire 7/16 Combination wrench.

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank

HyDefinition HD3070. Automatic Gas Console Upgrade. Field Service Bulletin (P/N ) Revision 2 April, 2002

Installation, operating and maintenance Instructions for Seemag bypass level indicator

I.H.S INSTALLATION INSTRUCTIONS

5000TOC Sensor Standard Operating Procedure for TOC Calibration Conductivity Calibration Temperature Calibration Flow Rate Calibration

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

RAM 4021 Operation Manual

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

Operating Instructions for Cobra and Lynx Duct Leakage Testers

TECHNICAL INFORMATION

ANY QUESTIONS? CONTACT ROYAL VENDORS CUSTOMER SERVICE DEPARTMENT IN NORTH AMERICA, CALL TOLL FREE

ServicePlus S21R & S27R Series 2 Installation Instructions

Aqua Control, Inc. 60Hz. BOTTOM CIRCULATOR INSTRUCTION MANUAL TABLE OF CONTENTS

Challenger Neon Air Hockey Table Owners Manual

GV Standard X-Vent. Setup, Commissioning & Installation Guide

Document How to Set Single Stage Press Pressures

with O 2 Controller Instruction Manual

POWERTRAIN CONTROL MODULE PIN IDENTIFICATION & VOLTAGE CHARTS > AXIOM 3.5L, PASSPORT, RODEO & RODEO SPORT 3.2L

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

Model 106 DPI "Micro-switch" Installation and Operating Instructions

To Purchase This Item, Visit BMI Gaming (800)

ACCESSORY KIT INSTALLATION MANUAL

Instructions for High Altitude Conversion

Section 3- Repair and Calibration Procedures

PS Plasma 375 Plasma Cutter Kit Assembly & Operating Instructions

APPS-160 Gen 2 User Manual

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

5 Channel Calibrator

Pressure Dump Valve Service Kit for Series 3000 Units

YSC-8330 USER MANUAL XI AN TYPICAL INDUSTRIES CO.,LTD.

ACV-10 Automatic Control Valve

User Manual for the Mars Calibration Bench

SII Trim/Installation/Set-Up Procedure for Ultrasonic Level Sensor Assembly with DST-2421-C30 Sensor - P/N

MODEL GT820 OXYGEN SENSOR

D I G I T A L C L A M

AHE58/59 AC Servo System

*ACTUATOR CIRCUIT TEST DIAGNOSTICS (DUAL-ZONE)

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

IntelliChlor Power Center (For use with IntelliChlor model IC60, IC40 and IC20)

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

User Manual for Amron International Diving Supply, Inc.

LENNOX SLP98UHV DIAGNOSTIC CODES

TR Electronic Pressure Regulator. User s Manual

V8200A,C,H,M and VR8200A,C,H,M Continuous Pilot Combination Gas Controls

INSTALLATION INSTRUCTIONS

Pump Performance Testing

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

UsER manual for Watersens ph -REDOX

VR400/VR800 SERIES. Honeywell CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION DESCRIPTION INSTRUCTION SHEET

TS-202 FFU Lever Remote Part Number & Operation & Installation Instructions Version 2.1

Item # in1 Rotating Table. Inch BILLIARDS AIR HOCKEY TABLE TENNIS

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

Air Check Lite Toxic Gas Monitor

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

TOYOTA TACOMA 2005 TOW HITCH Preparation. Part Number: PT

AMC-400 Series. Digital Transmitter with Smart Sensor USER MANUAL

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

SVEA II GSM Connector User Manual

Evaporative Emissions (EVAP) system, checking

WARNING! DISCONNECT BATTERIES BEFORE SERVICING.

ASG-SD2500 ASG-SD2500

MP15 Jockey Pump Controller

Catalina Spa-kle Installation and User Guide

Model 6810A Dual Lane Scoreboard Owner s Manual Rev B

Transcription:

Service Installation: 48 V Power Supply September 27, 2018 SI-92718 Written by BTA 48 Volt Power Supply Installation Guide PROCEDURE: Parts Needed: 48V Power Supply Kit Tools Needed: Standard screwdriver, ¼ Nut Driver, Wire Stripper INSTRUCTIONS: Review your kit to make sure everything is included b a d e f Kit Includes a. 48 Volt Power Supply b. A.C. Connector c. 48 Volt and Ground Wires d. 2 Wire Ties e. 4 Wood Screws f. 2 Wall Nuts c Make sure the game is powered off and unplugged. Rest the Playfield on the Yellow Service Stands. Remove the clear protective cover off the old power supply by removing the retaining nut.

Lay the new power supply to the right of the old power supply. 5 6 3 1 2 4 5 Remove the 2 Brown wires from the old P.S. #1, ensure there is a half inch of insulation removed from the wire and insert into an empty slot on the brown Wall Nut #3. (your game may have more than 2 Brown Wires, attach all of them to the Brown Wall Nut #3) Remove the 2 Black wires from the old P.S. #2, ensure there is a half inch of insulation removed from the wire and insert into an empty slot on the Black Wall Nut #4. (your game may have more than 2 Black Wires, attach all of them to the Black Wall Nut #4) Using the 4 Wood Screws, place a screw through each attachment point into the floor of the game. #5 (upper right attachment point is not shown in the picture) There should be no wires still attached to connector #6

Connect the A.C. power to the new P.S. 1 Disconnect the old A.C. connector #1 Connect the new AC connector attached to the new Power Supply to both ends of the old connector (pins in the new connectors may need to be adjusted/straighten if they do not mate properly with the old connector) Route the Green Ground along the right side of the cabinet towards the front and attach the Green Ground wire to the ¼ nut as shown

Verify that: ALL Black Wires are together on the same Wall Nut ALL Brown wires are together on the same Wall Nut ALL A.C. lines are going to the correct colors. On the Power Supply Verify that: The Brown wire is going to the +V terminal The Black wire is going to the -V terminal A.C. Input The Green wire is going to Ground Black is going to L White is going to N Once you are sure everything is connected correctly, plug in your machine and turn on the game. Next you will need to calibrate the coils If you are unable to obtain the desired coil response or your coil setting for any coil is at or over 30 you will need to increase the power supply output voltage. The voltage is set at 48 volts D.C. from the factory. Using a multimeter adjust the trim pot on the power supply until the meter reads 51 volts D.C. Recalibrate the coils. If coil response is still not acceptable or you are unsure how to adjust the power supply call the help line. 833-API-HELP CAUTION. WHEN PERFORMING THESE CALIBRATIONS, THE PLAYFIELD WILL BE ACTIVE! TAKE CAUTION WHERE YOU PLACE YOUR HANDS. 1. Open the coin door and remove the playfield glass 2. Pull out the interlock switch inside the coin door on the left side. 3. Put the game in test mode (page 3-6) and select Utilities>Clear Houdini s balls and follow the onscreen directions. 4. Catch the balls as they are cleared. 5. Press the green BACK/EXIT button once to return to main menu 6. Select Settings >Coil Adjustment Settings. LOWER CATAPULT Place a ball in the lower catapult located on the left side of the playfield, watch where the ball lands (when adjusted correctly the ball should pass through the opened trunk centered up and down between the base and lid of the trunk). If the ball lands before the trunk or hits the lower part of the trunk - increase the number of the LOWER CATAPULT by one and repeat the process. If the ball lands beyond the trunk or hits the trunk lid - decrease the number of the LOWER CATAPULT by one and repeat the process.

UPPER CATAPULT Place a ball in the upper catapult located right below the Trunk, watch how hard the ball hits the wire ramp (when adjusted correctly the ball should just barely make it into the ramp). If the ball does not make it to the ramp - Increase the number of the UPPER CATAPULT by one and repeat the process. If the ball hits the ramp to hard - Decrease the number of the UPPER CATAPULT by one and repeat the process. UPPER VUK Place a ball in the VUK located to the left of the mini playfield monitor, watch how fast the ball travels down the ramp (when adjusted correctly the ball should just make it over the apex of the ramp). If the ball does not make it over the apex of the ramp - Increase the number of the UPPER VUK by one and repeat the process. If the ball travels down the ramp too fast Decrease the number of the UPPER VUK by one and repeat the process. SCOOP Place a ball in the SCOOP located on the right side of the playfield just above the shooter lane, watch how fast the ball exits the SCOOP (when adjusted correctly the ball should barley make it out of the SCOOP and travel down to the right flipper). If the ball does not make it out of the SCOOP - Increase the number of the SCOOP by one and repeat the process. If the ball comes out of the SCOOP too fast - Decrease the number of the SCOOP by one and repeat the process OTHER COILS After you play the first game you might notice other coils needing adjustment. Adjust as needed. Play a test game, everything should operate normally at this point, if not call the service help line 833-API-HELP 1448 Yorkshire Rd Streamwood, IL 60107 Phone: 833-API-HELP www.americanpinball.com