Your patients, our primary focus. Siesta i Whispa anesthesia machine

Similar documents
State-of-the-art anesthesia technology

Your patients, our primary focus

Siesta i Whispa Integrated technology

Dameca MRI 508. State-of-the-art MRI technology

The centerpiece of a comprehensive anaesthesia workstation

An intuitive and innovative answer to your anaesthesia challenges

APUS Anesthesia Machines

A9600 Anesthesia Workstation. Your healthcare, we care.

APUS Anesthesia Machines

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Anesthesia Workstation

Safe Accurate Reliable. CWM-301 Anesthesia System

Anesthesia Solutions. Prima SP and Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

The anaesthesia workstation focused on you

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

Technical Data and Specifications

The anaesthesia workstation focused on you

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

SLE5000 Infant Ventilator with HFO

GE Healthcare. Aestiva/5. More than superior ventilation

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

AkzentColor. Anesthesia. Anesthesia and excellent ventilation for neonatal, pediatric and adult patients

V8800 Ventilator System. Your healthcare, we care.

Blease900 Ventilator PATIENT CENTERED VENTILATION

GE Healthcare. Avance Carestation. Upgrade promotions guide

Fabius MRI. From specialists for specialists. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

WILAmed INTENSA. Intensive Care Ventilator System

Carestation 650c. Key Features. Design. Ventilation

Carestation 650. Physical Specifications Product Description Carestation 620 A1 ANESTESI CARESTATION 650

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

INTENSIVE CARE VENTILATORS

Aespire 7100 Essential performance Compact design

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

PERSEO EVOLUTION. workstation for gaseous anaesthesia. for adults, children and newborns. Code: OM 403 / 3 gas module 3 rotameter

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

Carestation 620. Key Features. Ventilation. Design

DATA SHEET. VENTILATION SERVO-s

Flow meter. bellow vaporizer. APL valve. Scavenging system

Carestation 650. Key Features. Design. Ventilation

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

SERVO-s v8.0 Data sheet

D Your personal anesthesia assistant DRÄGER PRIMUS. Dräger. Technology for Life

Milestones of Aeonmed Ventilators

SERVO-air ventilator. Datasheet for system version 2.1

D The plus that makes all the difference DRÄGER FABIUS PLUS

SLE5000 Neonatal Ventilator with High Frequency Oscillation

D The specialist for every environment DRÄGER FABIUS TIRO

Draeger Fabius GS Pre-Use Check

Panther 5 Acute Care Ventilator

Oxylog 3000 plus Emergency & Transport Ventilation

INTENDED USE CLASSIFICATION PHYSICAL CHARACTERISTICS

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH

Dräger Fabius Tiro Anaesthesia Workstations

BleaseFocus Anesthesia System VERSATILE ANESTHESIA

Disclosures. The Pediatric Challenge. Topics for Discussion. Traditional Anesthesia Machine. Tidal Volume = mls/kg 2/13/14

Dräger Savina Sub-Acute Care Ventilation

D The plus that gives you more DRÄGER FABIUS PLUS

Intensa GO Alternate Care Ventilator

HAMILTON-MR1. Technical specifications HAMILTON-MR1

MT Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

Basics of Mechanical Ventilation. Dr Shrikanth Srinivasan MD,DNB,FNB,EDIC Consultant, Critical Care Medicine Medanta, The Medicity

Dräger Fabius plus XL Anaesthesia Workstations

Service Manual. Anesthesia System ANESTHESIA S ANESTHESIA SYSTEM

Oxylog VE300 Emergency & Transport Ventilation

Innovating with you Shaping exceptional care

Flight Medical presents the F60

fabian HFO: Modular, Powerful, Versatile.

Automatic Transport Ventilator

Dräger Fabius GS premium Anaesthesia Workstations

Ventilators. Dr Simon Walton Consultant Anaesthetist Eastbourne DGH KSS Basic Science Course

Anaesthesia Workstation. MODEL 7400A MODEL 7200A Glory Plus. Critical Care

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

AV-S Ventilator. Service Manual. Partnership for Life. Remote Display Module and Interface for use with A200SP Absorber

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

Apollo Safety Features

Using Common Ventilator Graphics to Provide Optimal Ventilation

fabian HFO Our 4-in-1 device

S/5 Aespire. Quick Reference Guide

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

IEC C LASSIFICATIONS:

PERSEO SERVICE MANUAL

Evita 2 dura. High-end ventilation in your patient s best interests. Because you care

Penlon MRI Product Range ANAESTHESIA SOLUTIONS

DATA SHEET. ANESTHESIA SYSTEM FLOW-i

Operation of Oxylog 3000 ventilator

ekom Compressor for Medical Air Sonata with Ekom

New Frontiers in Anesthesia Ventilation. Brent Dunworth, MSN, CRNA. Anesthesia Ventilation. New Frontiers in. The amount of gas delivered can be

Infant Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

Neonatal Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

Transcription:

Your patients, our primary focus Siesta i Whispa anesthesia machine

Functional, and flexible At Dameca we are not just committed to meeting the healthcare needs of today. We also think about tomorrow. The benefits are many Siesta i Whispa

to your needs Take a good look and you ll be surprised by the many forward-thinking features of the Siesta i Whispa anesthesia machine. Microprocessor-controlled ventilator The Siesta i Whispa ventilator compensates for changes in the fresh-gas flow and compliance in the breathing system. Pressure, spirometry data, and oxygen concentration are displayed on the 8 color TFT screen. Supports seven ventilation modes: VCV, PCV, SIMV, PSV, PRVT*, manual, and spontaneous. PRVT* Pressure Regulated Volume Target PRVT (Pressure Regulated Volume Target), a lungprotective ventilation mode that combines the advantages of Volume Controlled Ventilation (VCV) and Pressure Controlled Ventilation (PCV). PRVT continuously adjusts the inspiratory pressure based on the compliance and resistance of the patient s lungs and airways, to maintain pressure at the lowest possible level while providing the preset tidal volume. This provides optimum gas exchange and subsequent oxygenation during surgery. * Option High-level safety features The Siesta i Whispa has a number of built-in safety features, including: Hypoxic guard function, ensuring at least 25% oxygen in the oxygen/nitrous oxide mix A slave regulator cuts off nitrous oxide and sounds an audible alarm in the event of a failed oxygen supply A fresh-gas switch between the integrated breathing system and auxiliary gas outlet An oxygen flowmeter with separate outlet, including tube nipple and integrated patient suction unit Automatic self-test at start-up Built-in battery backup Space-saving design The slim, modular Siesta i Whispa is a compact choice for all operating theaters, occupying a minimum of space. Twin wheels allow the machine to be moved around smoothly and easily. Where floor space is particularly limited, the pendant and wallmounted solutions provide practical alternatives. We have done our best to integrate all the key functions into the machine as standard. Even the AGSS for gas evacuation is among the core functions, eliminating the need for a separate system on the side or rear of the machine. A backbar for mounting Selectatec vaporizers and simple mounting of all types of patient monitors adds to the flexibility of the Siesta i Whispa. Intuitive and user-friendly interface Integrated breathing system Microprocessor-controlled ventilator with seven advanced ventilation modes, including PRVT* 8 high-resolution color display High-level safety features Space-saving design Siesta i Whispa

Integrated breathing Forget about time-consuming, multiple-tube connections between the anesthesia machine, breathing system, and patient. Our integrated breathing system (IBS) integrates an ascending bag-in-bottle, patient circuit, and CO 2 absorber in one compact unit. That means no tubing between the breathing system and machine and only two tubes for inspiration and expiration between the breathing system and patient. The manual bag connection is located under the APL valve. Setting up for a procedure is fast, and cleaning is easy. In less than sixty seconds the breathing system can be taken apart for cleaning, without any need of special tools. The foolproof design prevents reassembly errors after cleaning. Bag-in-bottle The ascending bellows is designed to prevent air from being drawn into the breathing system in the event of a leakage. The capacity is up to 1500 ml, making it suitable for adults, pediatrics, and neonates. Valves Yellow valve flaps allow visual supervision of inspiration and expiration. An APL valve is also integrated and valid in the manual and spontaneous modes. i-sorb absorber Available in reusable or disposable versions, i-sorb minimizes the waste of unused soda lime thanks to its flow-optimized design. Soda lime capacity is 900 g. The absorber can be replaced while the machine is in operation.

system SIESTA i WHISPA Dimensions (H x W x D) Weight Hypoxic guard system Vaporizers Integrated breathing system (IBS) Absorber capacity Ventilation modes Tidal volume Respiration rate 1510 x 760 x 670 mm 110 kg Total flow range: 0 20 L/min Backbar for two Selectatec vaporizers (German or British standard) with interlock safety mechanism Vertical Insp./Exp. valve flaps Tool-free disassembly in less than sixty seconds Fresh gas introduced after Insp. valve 900 g VCV (volume-controlled ventilation) PCV (pressure-controlled ventilation) SIMV (synchronized intermittent mandatory ventilation) PSV (pressure support ventilation) PRVT* (pressure-regulated volume target) Manual, spontaneous 20 to 1500 ml 4 to 80 bpm I:E ratio 3:1 to 1:9,9 Electronic PEEP 4 to 20 hpa (cmh 2 O) Inspiratory pressure PCV 4 to 67 hpa (cmh 2 O) PSV 4 to 50 hpa (cmh 2 O) AGS System Ventilation measurements 3 0 to 40 L/min Peak, Plateau, and PEEP Pressure Patient compliance Tidal & minute volume Inspired O 2 %* Spirometry loop* * Option Siesta i Whispa

Siesta_i_Whispa_brochure_Nov2016 Dameca A/S Islevdalvej 211 2610 Roedovre, Denmark Telefon +45 4450 9990 Fax +45 4450 9999 info@dameca.com www.dameca.com 2016 Dameca - reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.