We Warm Animals. User Manual For. Darvall Heated Smooth-Wall Circuits. Darvall Heated ZDS Qubes

Similar documents
The SAV04 Small Animal Ventilator. Contents Page

Breathing Circuits. Product training

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

Hallowell EMC Anesthesia WorkStation Operating Manual

Recommendations on Checking Anaesthesia Delivery Systems

Selecting and Connecting Breathing Systems

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

Aespire 7100 Essential performance Compact design

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

The Merlin Small Animal Ventilator by Vetronic Services Ltd. Contents page. Introduction.2. Features of Merlin. 3

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Keeping anaesthetic pollution to minimum in theatre environment

M5400 Operators Manual

Anesthesia. Midmark Animal Health Products

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Complex Care Hub Manual: Pressure Ventilation on the LTV 1200

THE GE AISYS ANAESTHETIC MACHINE

Oxygen Therapy Devices

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Medical Instruments in the Developing World

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

My CoughAssist. A patient guide to CoughAssist T70. Please visit

Table Top and Convertible Anesthesia Machine Models: M3000 and M3100 (SHOWN WITH OPTIONAL EQUIPMENT)

Unit 15 Manual Resuscitators

Model 405 &407 Small Animal Ventilator. User Manual v3.5

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

DPA 02 TM Diamedica Portable Anaesthesia System INSTRUCTIONS AND USER GUIDE

VT900. Gas Flow Analyzer. Technical data. Key benefits and features:

SLE5000 Infant Ventilator with HFO

VT650. Gas Flow Analyzer. Technical data. Key benefits and features:

Anesthesia Machine Intro

Oxygen Delivery Systems:

URN (UNIVERSAL RODENT NOSE CONE) (17mm diameter) Figure 1

ekom Compressor for Medical Air Sonata with Ekom

RM-80 respiration monitor

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Heated Wire - Neonate Ø10mm Infant Ø12mm

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

VSM Ventilation Sequencer Module Type 698

Stand-Alone Bubble Detection System

Data Sheet... RUDOLPH, inc. HANS RUDOLPH,

Draeger Fabius GS Pre-Use Check

STARLOG. Capacitive Water Depth Probe

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES IEC COMPLIANT

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

Tafonius. Auxiliary Mode Operating Manual A USERS GUIDE

The Univentor 1250 Anaesthesia Unit

Guidelines on Monitoring in Anaesthesia

The centerpiece of a comprehensive anaesthesia workstation

Operation and Maintenance of the EPV200 Portable Ventilator

ISO 5367 INTERNATIONAL STANDARD. Breathing tubes intended for use with anaesthetic apparatus and ventilators

SLE5000 Neonatal Ventilator with High Frequency Oscillation

INSTRUCTION MANUAL. (Variante 2 / System 2) Surgery table standard (Variante 1 / System 1)

VIMA. (Volatile Induction and Maintenance Anesthesia) How and Why. James H. Philip M.E.(E), M.D.

Siesta i Whispa Integrated technology

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.

DX 3 RCDs. Technical data Nature and consequences of electrical risks Direct and indirect contact. Direct contacts


Practical considerations in anaesthetising exotic species. By Keith Simpson BVSc MRCVS AMIIE(Electronics).

2011 Equipment Catalog

Operating Instructions Part No

SomnoSuite Low Flow Anesthesia System for Mice and Rats. Owner s Manual

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

ACUC ۰ ROUTINE PROCEDURE

KOALA. Disposable Adult Anaesthetic Circuits for Low Flow Anaesthesia KO.S5.22MM. Adult Anaesthetic Circuits. Medical Pty Ltd

ES18 Security Theory/Regulations Answer Schedule

Technical Data. Dimensions

THE UNIVENTOR 400 ANAESTHESIA UNIT

RAM 4021 Operation Manual

Gas density monitor With integrated transmitter Model GDM-100-TI

Oxylog 3000 plus Emergency & Transport Ventilation

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Monitoring, Ventilation & Capnography

SEMEM3-65 Servicing anaesthetic and ventilation equipment

JUMO dtrans p30 Pressure Transmitter

AutoChanger Installation & User Guide Issue 2

Anaesthetic and respiratory equipment Breathing sets and connectors

Capnography in the Veterinary Technician Toolbox. Katie Pinner BS, LVT Bush Advanced Veterinary Imaging Richmond, VA

Oxylog VE300 Emergency & Transport Ventilation

Pressure Measurement Single-range transmitters for general applications

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

HumiSys HF High Flow RH Generator

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

(Delivery System) Pocket Guide. Series 3 software

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

INSTRUCTION MANUAL. Combi-vet Anesthesia system

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING

Great products available through ROI!

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

FAULT CODE TROUBLESHOOTING INDEX

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Anes Machine Use and Pre-use Check - CA1 focus

Transcription:

We Warm Animals User Manual For Warm Inspired Air Control Unit to use with Darvall Heated Smooth-Wall Circuits or Darvall Heated ZDS Qubes For Veterinary Use Only

Warm Inspired Air Control Unit Use for Veterinary Anesthesia with Darvall Heated Smooth-Wall Circuits (HBC) On Circle Systems for Cats, Dogs and other small animals up to 80Kgs or Darvall Heated ZDS Qubes A Non-Rebreathing System for Rodents, Birds, Exotics, Reptiles, Pups and Kittens For Veterinary Use Only Not intended or approved for Human Medical purposes Not evaluated to Human Medical Standards Evaluated By MET Laboratories to IEC / EN 61010-1 Electrical equipment for measurement, control, and laboratory use User Manual Contents Contents... 2 1. Introduction... 2 2. Heated Breathing Tube... 4 3. Qube - Heated Anaesthesia Block... 4 4. Heated Breathing Circuit controller... 5 a) Description... 5 b) Connecting up the controller... 5 c) Stand-alone heated tube... 6 d) Computer monitored heated tube... 6 e) Auxiliary temperature monitoring... 6 5. ZDS Qube connections... 7 6. Safety Features of the HBC system... 8 7. Specifications... 8 8. Parts for replacement and consumables... 9 9. ZDS Qube Mask Sizes... 11 Introduction

Maintaining anaesthesia in small animal veterinary practice is most commonly achieved using inhalation of volatile vapour ("anaesthetic gas"), typically isoflurane. The anaesthetic gas is generally delivered by flowing oxygen through a vaporiser, to a breathing system which is connected to the animal via flexible plastic tubing (breathing hoses). The breathing hoses are replaced on a daily basis to permit cleaning. Most commonly in dogs and cats, unconsciousness is induced by using a short acting intravenous anaesthetic, then an endotracheal tube is placed into the animal s airway and sealed to make a gas tight connection with the anaesthetic breathing system. This means that the animal s nose has been by-passed. The inspired gas, usually at room temperature (20 o C to 22 o C in surgery rooms) must be warmed to body temperature = 38 o C and 100% humidified before reaching the lungs. Expired gas temperature and humidity, usually recovered by the nose, are lost to the expired limb of the anaesthetic breathing system, so small animals become cold (hypothermic) during anaesthesia which results in longer recovery and increased anaesthesia mortality compared to normo-thermic animals. AAS Heated breathing circuits warm the inspired anaesthetic gas close to body temperature (38 o C) for small animals. This may be useful in reducing heat loss and pulmonary flow resistance, and avoiding bronchospasm and laryngospasm due to the inspiration of cold gas.in asthmatic animals. We have developed 2 two principle devices for the broadly similar purpose of warming inspired anaesthetic gas, depending on the animal s size and the practicalities of intubation. These are the Heated Breathing Tube, and the Qube. The Heated Breathing Tube is designed for anaesthesia of small animals (e.g. dogs, cats, rabbits etc.) where the inhalant anaesthetic is typically delivered via an endo-tracheal tube from a circle breathing system The Qube is designed for anaesthesia of very small animals including rodents (mice, rats, gerbils etc.), birds, reptiles and other exotic species such as found in zoological parks, where intubation may not be possible or practical. Figure 1 Diagram of an anaesthetic machine with a circle breathing system

1. Heated Breathing Tube Heated breathing tubes are novel devices (AAS Patent Applied for 2011), designed for anaesthesia of small animals (e.g. dogs, cats, rabbits etc.) where the inhalant anaesthetic is typically delivered via an endo-tracheal tube from a circle breathing system (Figure 1) The inspired gas is warmed by passage through an inspiratory heated breathing tube. Advanced Anaesthesia Specialists (AAS) produces 2 sizes of heated breathing tubes designed for animals: 12mmID or 16mmID and both 1.5m long (breathing tubes used in anaesthesia of adult humans are typically 20mmID). The AAS tubes include a heating wire embedded in the wall of the tube spirally extending along the length of the tube. In addition, at the endotracheal end of the breathing tube a temperature sensor extends radially into gas stream. This heated breathing tube is supplied thermostatically controlled power via a 4 conductor cable by the HBC control unit. 2. Qube - Heated Anaesthesia Block Heated rodent anaesthesia blocks (Registered trademark Qube) are novel devices (AAS Patent Application lodged 2010) designed for anaesthesia of very small animals including rodents (mice, rats, gerbils etc), birds, reptiles and other exotic species such as found in zoological parks, where intubation may not be possible or practical. In this case the inhalant anaesthetic is delivered via a sealed, zero dead space face mask (place over the animal s nose or beak) which is connected to an anaesthetic gas delivery block which can be heated to warm the inspired gas (Figure 2) Figure 2 Diagram of a Heated Rodent Anaesthesia Block connected to an anaesthetic machine

The AAS Qube block (50 x 50 x 70 mm, 0.25 kg), is warmed by two embedded thermostatically controlled heater elements from power supplied by the Heated Breathing Circuit controller. Anaesthetic gas is fed to a barbed input port and passes along a warming path through the block. The warmed gas is delivered to the mask connection port to then be inhaled by the animal. There are a range of Qube mask sizes and shapes available for specific species and applications (see ZDS Qube Mask). Exhaled gas exits via a second port into a waste gas removal tube. 3. Heated Breathing Circuit controller a) Description The Heated Breathing Circuit controller is an embedded microprocessor based system with the following functionality: 1) Monitoring the Heated Breathing Tube or Qube temperature close to the animals airway and continuously report the temperatures to the HBC display and an attached (via USB) computer 2) Control the heating power to the Heated Breathing Tube or Qube 3) Detect over temperature, disable further heating and report the condition to the HBC display and an attached (via USB) computer 4) Detect sensor error conditions and report the condition to the HBC display and an attached (via USB) computer 5) Allow an auxiliary temperature to be measured from an additional sensor which may report on animal core temperature or exhalation temperature as required. Continuously report the auxiliary temperatures to the HBC display and an attached (via USB) computer 6) Display the temperature in Celsius or Fahrenheit (selectable ) on an LED display 7) Operate both with a USB attached computer and autonomously in Stand-alone mode b) Connecting up the controller The controller is designed with flexibility of use in mind and can be connected up in a number of different ways. Figure 3 Darvall Heated Breathing Circuit Controller connected to a Darvall Smooth-Wall heated breathing circuit. The inspiratory limb of the circle system is connected to the Heated Breathing Circuit Controller at the canister end of the inspiratory tube. The animal end of this tube has an imbedded temperature sensor to monitor the temperature of the inspired gas.

c) Stand-alone heated tube A power plug (IEC) is connected to the rear of the unit and a D15 plug is connected between the front of the unit and the heater tube. (Figure 3). The anaesthetic gas circuit is connected in the required configuration. d) Computer monitored heated tube Connected as with Stand-alone (a) and add a USB connection from the controller (on right hand side, side panel) to the computer. The AAS HBC software will detect the connection automatically. Note also that when connected to a computer and no mains power is present at the IEC socket, the controller will operate in all monitoring ad data logging modes, but no heating will be available. This condition will be reported with a special error code to the computer. e) Auxiliary temperature monitoring An additional sensor may be plugged into the auxiliary jack socket on the controller s front panel (in addition to connections in (a) and (b) above). Which sensor being monitored on the LED display on the controller s front panel is indicated by the two LEDs near the D15 socket on the front panel. Note If there is no heater element (tube) present, the auxiliary temperature may still be monitored.

4. ZDS Qube connections The Qube heating block may be used in place of the heated tube. The electrical connections are similar to those described in (a), (b) and (c) above except that the D15 cable has a 4-pin mini XLR plug on the end which goes into the Qube. Figure 4 Shows 2 ZDS Qube. The ZDS Qube block on left shows rodent in a mask being monitored by an auxiliary temperature probe. The ZDS Qube block in the centre is connected to the Heated Breathing Circuit controller which provides power and monitors the temperature of the block. The HBC controller is on the right. Figure 5 Close up of the ZDS Qube block. The Red light shows that heating is on. In this picture the gas ports are not connected to the anaesthetic gas delivery machine (small top port is anaesthetic gas in; the large bottom port is waste anaesthetic gas out)

5. Safety Features of the HBC system 1) Modern anaesthetic vapour agents are generally regarded as non-flammable during clinical anaesthesia The heating elements of the HBC system are designed to never contact the anaesthetic gas; (indirect heating), eliminating electrical fault conditions as an ignition source to the gas. 2) The HBC system maintains electrical isolation between the animal and conductive surfaces in the system. 3) The temperature monitoring sensor close to the animal prevents thermal damage to the airway. 4) An over safe operating temperature condition will cause an alarm and disable further heating 6. Specifications Power source Power connector Internal Power supply Controller Enclosure Heating voltage Temperature Sensor 100-250V AC mains IEC C13 connector with integral switch and fuse allowing IEC C13 cables with international plug varieties 75W Switch Mode Power Supply fixed 24V DC output unit is enclosed metal frame type with UL certification and CE mark Single printed circuit board with all control components. Input voltage 24V logic operating voltage 5V Purpose built all steel construction in two parts both parts with earth link. Top half with narrow ventilation slits - lower half contains solid barrier to prevent contact with mains through ventilation slits 24V thermistor

7. Parts for replacement and consumables Part Number Photo Description Controller Parts 8445 Heated Breathing Circuit controller ONLY Aus/NZ - 8970 UK 8971 US - 8998 EU 8999 IEC mains cable with regional appropriate plug 8968 USB cable (USB A to USB mini B plugs) Heated Breathing Circuit Parts 2-20kg 8347 20-80kg 8348 Heated Breathing Circuits 8615 Cable HBC to breathing tube ( 15 pin D connector to 4pin block)

Qube Parts Qube ONLY 8270 Qube + Rodent Masks 8437 Qube + Exotics Masks 8457 Heated Qube 8619 Cable HBC to Qube ( 15 pin D connector to 4pin mini XLR) Auxiliary temperature measurement Parts 4.0mm Cat/Dog 8617 3.2mm Rodent 8618 Auxiliary temperature probe 8616 Auxiliary Expiratory tube cable

8. ZDS Qube Mask Sizes Part # Description Application Diagram 8382 ZDS Qube Mask 15mm Offset Tapered White Acetal Shortened 20mm offset mouse facemask specifically for stereotaxic block Typical Species:- Mouse 8416 ZDS Qube Mask 20mm Offset Tapered 3/4"/20mm offset tapered. Supplied with two 20mmOD - 0.3"/8mm ID aperture diaphragms Typical Species:- Mouse 8415 ZDS Qube Mask 20mm Straight 3/4"/20 mm straight. Supplied with two 20mm OD - 0.3"/8mm ID aperture diaphragms (#8334) Typical Species:- Small Rat 8414 ZDS Qube Mask 25mm Tapered 1"/25 mm tapered. Supplied with two 25mm OD - 1/2"/12mm ID aperture diaphragms (#8335) Typical Species:- Large Rat 8413 ZDS Qube Mask 40mm/1.5" offset tapered 8420 ZDS Qube Mask 15mm Tapered Endotracheal Tube Adaptor 1.5"/40mm tapered, offset - supplied with one silicon diaphragm with 3/4"/20mm aperture Typical Species:- Rabbit / Ferret - for use with all standard ET tubes (0.6"/15mm ID) Typical Species:- Mouse 8381 ZDS Qube Mask Blanking Plug Black Acetal Sealed off blanking plug for use on 5 station manifold when stations are not in use.

Trademarks Darvall is a registered trademark of Advanced Anaesthesia Specialists Pty ZDS Qube is a trademark pending of Advanced Anaesthesia Specialists Pty Information contained in this publication regarding device application is intended through suggestion only. It is the user s responsibility to ensure that the equipment discussed in this document meet the needs of your requirement. It is the user s responsibility to operate the equipment in a safe manner. Copyright 2012-2014 Advanced Anaesthesia Specialists Contact Details:- Australia (Headquarters) Advanced Anaesthesia Specialists Pty Web: - www.aasmedical.com.au Email: Sales@aasmedical.com.au Telephone: +61 298081844 USA UK Advanced Anaesthesia Specialists LLC Web: - www.darvallvet.com Email: info@darvalvet.com Telephone: (866) 9313292 Advanced Anaesthesia Specialists Web: - www.aasmedical.co.uk Email: Sales@aasmedical.co.uk Telephone: +44 8456024330