APA software instruction manual

Similar documents
SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

Section Freepoint Service 26.1 FREEPOINT CONTROL PANEL

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

BathySurvey A Trimble Access hydrographic survey module

DRILL MONITOR DM-100 OPERATIONS MANUAL

Hydro-Control V User Guide

FTC130 Transmitter. Operating Manual

Manual Weighingblock VB2 series and Uniscale

1. Hardware Bookkeeping & Adjustment...7. Access Flow Chart... 7 System Adjustment... 8 Chance Adjustment... 9 Touch Screen Calibration...

Cover Page for Lab Report Group Portion. Head Losses in Pipes

SPLIT HOPKINSON PRESSURE BAR OPERATIONS MANUAL 5/9/2014

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Touch Screen Guide. OG-1500 and OG Part # T011

XC2 Client/Server Installation & Configuration

Operating instructions Electrical switching facility pco

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

Operations Manual. Internal automatic Pressure control for orbital tube welding. By Exel Orbital Systems, Inc. Page

CONSUMER MODEL INSTALLATION GUIDE

TR Electronic Pressure Regulator. User s Manual

Microsoft Windows Software Manual for FITstep Stream Version 4

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Oxygen Meter User Manual

Stand-Alone Bubble Detection System

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

Datasheet: K-30 ASCII Sensor

FOOD INTAKE MONITOR. Hardware and Software User s Manual DOC-047 Rev 3.0. Copyright 2009 All Rights Reserved

Overview. Front Panel: Keypad and Display

Apollo Safety Features

KEM Scientific, Inc. Instruments for Science from Scientists

DIY - PC - Interface for Suunto Cobra/Vyper/Mosquito

Figure SM1: Front panel of the multipatcher software graphic user interface (GUI) at the beginning of multipatcher operation.

ELIMINATOR INSTRUCTIONS Table of Contents

LED CONVERSION BOARD - YAKUZA SERIES EGO/GEO

Using the UltraRAE. Firmware 2.35

User manual CF8-D/W-IN

SECTION 2 SMART PAYOUT MANUAL SET FIELD SERVICE MANUAL

Wickets Administrator

D-Opto Dissolved Oxygen Sensor Operation Manual

User Manual. ENGLISH Pages FRANÇAIS Pages ESPAÑOL Páginas DEUTSCH Seiten 53-69

HyperSecureLink V6.0x User Guide

SWS Option: Well Pressures. SWS Option: Stretch Correction (Corrected depth) SWS Option: MMD (Magnetic Marks Detection) ASEP Products

A4s Operation Manual

Mitos Fluika Pressure and Vacuum Pumps Datasheet

FIG: 27.1 Tool String

GV Standard X-Vent. Setup, Commissioning & Installation Guide

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

MIE Medical Research Ltd Digital Analyser Pinch/Grip Instruction Manual

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Device overview. 6 Breathing circuit connection. Note: When the remote control foot pedal is connected, the manual switch is disabled.

1)! DO NOT PROCEED BEYOND THIS MARK

MP15 Jockey Pump Controller

REASONS FOR THE DEVELOPMENT

Boyle s Law: Pressure-Volume Relationship in Gases

Lab #1 Pressure: Bubblers and Water Balloons CEE 331 Fall 2003

Version-E Manual

Remote Control Bait Boat

2. USER INSTRUCTION. Table of contents: Pg.1/14 N:\FAP-2000: LWP

OMNISPORT 2000 SWIMMING QUICK REFERENCE

Experiment P18: Buoyant Force (Force Sensor)

Gait Analysis System. User Manual and Outcome parameters Patent WO2012/ A1

Gas Analyzer for TC Sensors (CO2, H2, N2) Series 62101, 64101, Operating Manual

Three Lakes Association Hydrolab for Dummies. Table of Contents:

OC508 Programmable mv Calibrator

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

SIDRA INTERSECTION 6.1 UPDATE HISTORY

Microfluidic Demonstration

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

BUYER S GUIDE AQUAlogger 530WTD

DeeterFlow Automatic Liquid Dispenser

MASSACHUSETTS STATE POLICE CRIME LABORATORY. Certificate of Calibration Procedure for the Alcotest 9510

AX5000 Operational Manual

Helium Level Measurement Unit

DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS

D-OptoLogger Dissolved Oxygen Logger Operation Manual

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

Roller AC Servo System

Software Manual for FITstep Pro Version 2

In Vivo Scientific, LLC INSTRUCTION MANUAL

e360t and e360t+ Model

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

DBI version 002 User Manual US version Free Balloon Flight Instrument

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

Cover Page for Lab Report Group Portion. Pump Performance

[XACT INTEGRATION] The Race Director. Xact Integration

LX Compass module 3 Electronic compass device User manual

J12 TICKET DISPENSER HOPPER ALL STOP STOP 1 STOP 2 STOP 3 BIG DOUBLE SMALL TAKE PLAY START CURRENT PRODUCTION BOARD TYPE

New product release. Universal Rebreather Monitor (URBM) Three cell / Independent backup

The ICC Duckworth-Lewis-Stern calculator. DLS Edition 2016

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

DST Host User Manual

ISM-3 User Manual PBI D 04/2013

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system

Soft Systems. Log Flume - 1. Enter Specification. Activity One ACTIVITIES. Help. for Logicator

Operating Instructions Part No

RM-80 respiration monitor

eflo ELECTRONIC GAS FLOW METER OPERATIONS MANUAL

User s Guide. Model ESM1500 FORCE TEST STAND

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Transcription:

1. Starting the program In order to start the control software for the APA device press APAxx shortcut located on the desktop of the supplied computer. XX corresponds to the current software version. When asked to fill in the area of the probe write one of the values 0,5; 1 or 2. This value should correspond to the area of currently attached probe in cm 2. Use a comma as the decimal sign. After filling out the probe area proceed to the control program by pressing the Start -button. 2. User Interface When the program starts the control panel will be displayed. At the same time the probe is reset to its starting position, the calibrator is reset as well as internal calculations. The control panel, directly after the start of the program, will have a look as displayed below. Each of the fields on the panel is further discussed below. 2016-03-23 APA Manual 1.0 for SW ver. Page 1 of 9

2.1 Setup and settings In this part of the panel the user can adjust the measurement and stimulation settings as well as run the Warmup routine. The calibration values for the system can be changed in the Setup menu. However this should not be required except when the maintenance is performed. Warmup Runs the warm up routine. Should be run before the stimulations start in order to get the most accurate stimulation and measurement results. Do not hesitate to run the routine several times if the APA system has not been in use a longer period of time. Setup Toggles to the setup screen where calibration parameters are set and internal data is displayed. The setup screen is further discussed in 2.5. Contact Pressure The pressure that the probe applies during Contact and Hold instructions before and just when contact with skin is made. Clearance The distance between the probe and skin after Preset instruction is performed. Pressure Slope The speed of pressure increase after the Threshold instruction is performed. Hold Time The amount of time the pressure is applied during the Hold instruction. The timer starts running when the probe reaches the skin. 2016-03-23 APA Manual 1.0 for SW ver. Page 2 of 9

2.2 Control buttons and Current action display In this part of the control panel user selects what instructions to run and can survey the process while an instruction is being executed. Reset Resets the probe to the upper position and cancels other instructions. The instruction can be triggered in three ways: through pushing the button on the control panel, through patient response ball and from an external machine using the D-SUB connector. If an instruction needs to be cancelled, the patient experiences discomfort or pain due to, for example, study of pain threshold, or APA displays unexpected behaviour the reset instruction should be run. Contact Starting from its current position the probe is lowered until contact with skin is made. When contact is made the distance travelled is saved and the probe returns to starting position. Preset The probe is lowered towards the skin, but stops when clearance distance remains until contact. The clearance can be set using a slider scale in settings. Threshold Continuously increases the pressure that the probe applies with a speed as selected trough Pressure Slope slider scale in setting. When the desired threshold is reached, the instruction should be interrupted, for example, using the patient response ball. The maximal applied pressure is then saved. N/A, 60% - 130% If a threshold pressure is available select one of the buttons 60%-130% to apply corresponding percent of the measured threshold. The probe starts with lowering down to the surface of the skin, then the selected pressure is applied for the time selected through Hold Time slider scale in settings. Current action indicators Current instruction being performed is indicated through a green light being lit to the right of the instruction text. The instruction texts are Standby, Reset, Contact, Preset, Threshold and Hold. 2016-03-23 APA Manual 1.0 for SW ver. Page 3 of 9

2.3 Displays The results and stimulation history are found in this part of the control panel. Graph In the graph the probe position is displayed in red (mm) and pressure applied by the probe is displayed in blue (kpa). The graph is continuously updated with latest movements and applied pressures. Note that the position is accurately updated on the way down, the movement back to start position is not of interest and is displayed as a vertical step. Measurement Values Pressure: The current pressure applied by the probe. Skin Contact: The distance at which contact with skin was made during latest Contact instruction. Position: The current position of the probe. Threshold: The latest threshold value acquired through Threshold instruction. Calibrator: The force currently applied to the surface of the calibrator device. 2016-03-23 APA Manual 1.0 for SW ver. Page 4 of 9

2.4 Status displays and buttons This part of the control panel displays current status of the APA device and provides buttons to manipulate the state of the program. Status Lights Probe status light is either Green/Ready or Red/Busy and indicates if the APA device is ready to receive next instruction through button push or externally through D-SUB connector. Hold status light is either Green/On or Red/Off. During Hold instruction it indicates if the probe has found the skin surface and is currently applying the selected pressure. Exit and Reset Calib Buttons Reset Calib: Sets Calibrator value to zero in the Measurement Values. This can be utilized to set alternative baseline or reset calibrator after a significant force was applied. Exit: Moves the probe to its starting position, stops measurement and closes the program, then returning to the Windows desktop. 2016-03-23 APA Manual 1.0 for SW ver. Page 5 of 9

2.5 Setup Screen Setup screen is used to calibrate the APA device and control its functionality. The user is advised to change only the Push Depth parameter, if needed. Other parameters are changed only during calibration of the device, which requires in-depth understanding of its function. Push depth A parameter that should be set depending on how soft the skin and underlying tissues are in order to adjust the positioning during Preset. Under normal circumstances 2mm is a good estimation for this parameter. For very soft tissue it might be increased to 5-10mm or even more. Offsets and Gains These parameters are used in order to calibrate the APA software s internal functions against the calibrator. 2016-03-23 APA Manual 1.0 for SW ver. Page 6 of 9

The graphs in Setup display are: pressure applied by the probe (red, kpa), pressure applied to the calibrator by 1cm 2 probe (blue, kpa), average velocity of the probe minus current velocity (pink, m/s) internal signal indicating skin contact (green). Probe Size Displays what probe size was chosen during the start-up of the program and is currently used for the calculations. If probe is changed, the program must therefore be restarted. Measurements Button that returns user to the control panel. 2016-03-23 APA Manual 1.0 for SW ver. Page 7 of 9

3. Additional Notes Usage guidelines not covered by basic instructions In order to apply small pressures accurately it is beneficial to use the probe with maximal area, i.e. 2cm 2. When studying pressures below 200-300kPa this option should always be considered. It is essential that Contact Pressure parameter is lower than applied percentage of the threshold, in other case the initial touch of the probe will surpass the stimulation pressure. This might interfere with the study method and provide incorrect results in terms of the sensation the test subject experiences. The distance measuring algorithms might produce small errors, if it is essential that the probe should not touch the skin before Threshold or Hold instructions, select slightly higher Clearance. If one of the percentage buttons is selected before threshold is found nothing will happen. However in order to proceed it is advised to press the reset button before selecting next instruction. 2016-03-23 APA Manual 1.0 for SW ver. Page 8 of 9

4. Connections to the APA remote control connector: Connected through a standard 15 pin D-SUB connector. There is a male connector on the APA front, a connecting cable need thus to have a female connector. Connections: Pin Function Remark 1 Ground Connected to APA and computer ground through USB port. 2 Preset Set probe to Preset position. 3 Hold 1 Least significant bit of Remote HOLD command. 4 Hold 2 2 nd bit of Remote HOLD command. 5 Hold 4 3 rd bit of Remote HOLD command. 6 Hold 8 4 th bit of Remote HOLD command. 7 READY High when OK to give new command, low when probe is active or in WAIT state. 8 + 5 Volt From USB interface, use as voltage reference for digital signals. 9 CONTACT Probe in contact with skin. 10 PPB/RESET High when PPB not activated. Ground set s APA in RESET state. 11 not used 12 not used 13 not used 14 Ana gnd Analog ground 15 P OUT Pressure reference output. PPB = Patient push-button = The rubber ball for patient response. Remote HOLD command is constructed from the function IF (H1+H2+H3+H4)>0 then HOLD = 55 + (H1*1 + H2*2 +H4*4+H8*8)*5 % of last measured pressure threshold. Else HOLD is set by front panel switches. Check for READY high before setting a Remote HOLD or PRESET command. Reset the command(s) as READY goes low. RESET is always possible to set => probe pressure stops and probe returns to retracted position. The same action if PPB is pressed. 2016-03-23 APA Manual 1.0 for SW ver. Page 9 of 9