Mission SuperChill Pluto Edition

Similar documents
Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

DUQUESNE UNIVERSITY. Liquid Nitrogen Safety

Liquid Nitrogen Experiment Tips

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 022 MOD: 1st Issue Page: 1 of 8

General remarks regarding ALS robot system:

School of Plant Biology - Liquid Nitrogen Induction

Procedure for Filling 2 T Bruker Magnet with Nitrogen

OPERATING & HANDLING INSTRUCTIONS

PARTICLE SPACING PART 1

Rev. 1. Cryogenics Thermoflasks. 2122, 2123, 2124, 2129, and 2130

Chem Bio Liquid Nitrogen Facility

Talk Science Professional Development

Cryogenic Materials Operating Procedure and Safety Requirements

Evaluation copy. Wind Chill. computer OBJECTIVES MATERIALS

Working with Cryogenic Liquids

LAB 5 Pressure and Fluids

Science Museum Group Risk Assessment Form

PROCEDURE FOR THERMAL CYCLING IN LIQUID NITROGEN

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

DEMONSTRATION 2.1 PROPERTIES OF CO 2. Chapter 2: Gases

Automatic LN2 Fill Station Instructions

Balloon. Parachute. Payload

Standard Operating Procedure (SOP)

Mini-Labs. 7. Movie Fog 8. Jet Power 9. Sauce Pan 10. Magnetic Bubbles 11. Aquarium Magic 12. Hockey Puck 13. Carbon dioxide balloons

[USING THE VITROBOT April 9, Using the Vitrobot

Week 2 Sunday, January 18 th. Topics to be Covered Tonight:

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS

Step By Step Instructions for VT Experiments on the Bruker 300 MHz Spectrometer

WHAT IS GAS TANK/CYLINDER?

Tech Tips (June/July 2016) Product Information

Standard Operating Procedure Porosity Analyzer - The Micromeritics Tri-Star II (surface area) with Micrometrics VacPrep 061 (Sample Degas System)

EHS Laboratory Guidance: Cryogenic Material

Standard Operating Manual

Lecture Demonstrations Safety Manual & New Staff Induction

THE UNIVERISTY OF NEWCASTLE - SCHOOL of BIOMEDICAL SCIENCES

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Pump out insert (condenser and still lines) overnight with turbo pump

Motion Commotion. KindergarTen-second. Matter and Energy TEKS. Vocabulary

Trilogy Theory of Operation

BELT DRIVE INDOOR CYCLING BIKE SF-B1712 USER MANUAL

EXPERIMENT XI. Careful!! Improper handling of the vacuum line may result in the release of SO 2 which is an irritating and suffocating gas.

Wet Lamination of Dry Film Photoresist for the Hobbyist

Doc #: 2100 AD Revision: A

Before you start sampling, be sure to read

BELT DRIVE INDOOR CYCLING BIKE SF-B1712

Build your own weather station

Extension Activities:

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Alpine Rock Skills Course Pre Course Information

Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices. Unit Objectives. Pressure Vessels and Piping (1 of 2)

Cooling Gases Phase Changes and Phase Diagrams

Instruction Manual Updated 7/26/2011 Ver. 2.2

To derive from experiment the relationships between Pressure (P), Volume (V), Temperature (T), and Water Solubility of gases.

1.0 PURPOSE The purpose of this procedure is to describe the use of basic aseptic technique.

Molecular Materials Research Center Beckman Institute California Institute of Technology

L-23 Super Blanik Rigging (assembly/disassembly) Guide Maj Carl Kerns

OUTREACH SPRING QUARTER 2002

Installation of Your SprayMaster System

Bay Area Scientists in Schools Presentation Plan

Materials: Balloon demo (optional): - balloon, string, drinking straw, flour (optional)

Customer Responsibilities

ExamLearn.ie. The Air & Oxygen

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

1. A proper preparation of the cone and other material is inevitable prior to a CPTU test.

Principles of Pressure Canning

Technical Service Bulletin June 2015 TSB122.06

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources

Compressed Gases and Cryogens

SCIENCE Research how living things rely on carbon dioxide, study the greenhouse effect, research carbon dating

Our technical information is based on Tip: calls attention to special information.

Material Handling and Storage of compressed gases and Air equipment

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high)

Johnston Invar Coupling Johnston Invar Coupling

Bay Area Scientists in Schools Presentation Plan

We can tell that diameter of the tube influence the pressure of the water at the bottom.

Removing Yourself from Hazards During Equipment Operation

3.4 Compression of Fluids

DCIF Training Guide Variable Temperature Bruker B400 (last update )

ì<(sk$m)=bdiebi< +^-Ä-U-Ä-U

Temperature Liquid Oxygen

Rocket Lab Activity Plan: Rockets. Goal. Learning outcomes. Vocabulary MATERIALS. Accessing prior knowledge (10 minutes)

FRAME FEATURES TABLE OF CONTENTS INTRODUCTION. A guide to your Cervélo C Series frame.

What Causes Weather Patterns?

Properties of Gases Observing Atom Pressure of a Gas Measuring Gas Products of Chemical Inferring Molecule Reactions

INDOOR CYCLING BIKE SF-B1110 USER MANUAL

Nanoelectronics Lab, SR B14 Rules you must agree to follow for access

Liquid Helium Bath Cryostat

SAFE WORK PROCEDURE LOCATION WRITTEN BY APPROVED BY DATE CREATED LAST REVISION. All Schools Lorie Carriere Physical Therapists April 25, 2017 new

FORCE MOTION AND ENERGY EXPLORATION. Egg Spin

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

MJB4 Mask Aligner Operating Procedure. Effective Date: 07/12/2012 Author(s): Jiong Hua Phone:

INSTRUCTION MANUAL FOR POLYKEG DISPOSABLE KEG

OYC Opti 2018 Training Program Instructors Guide Points to cover

Good tread, no splits, cracks or holes, properly inflated. True, no missing or broken spokes, good rim. Secure, facing in right direction

Questions. theonlinephysicstutor.com. facebook.com/theonlinephysicstutor. Name: Edexcel Drag Viscosity. Questions. Date: Time: Total marks available:

Quattrocycle BV. Quattrocycle. User Manual. Last update February Quattrocycle BV Bremkant EJ Middelbeers. User Manual Quattrocycle 1

Exploring the Properties of Gases

Right-Angle Tube Roller Model

Transcription:

Mission SuperChill Pluto Edition Training Manual Mission SuperChill, page 1 of 7 Brief Summary Using media, props, a TV camera and liquid nitrogen (LN) a demonstrator will illustrate the surface conditions on Pluto. In addition this show presents some of the challenges NASA scientists and engineers will face in designing a spacecraft to visit Pluto or other such locations. You must complete the training requirements (listed at the end of this document) before performing this show. Educational Strategy Rather than perform a stand-alone Liquid Nitrogen Show the main teaching points have been connected to Space Odyssey by putting them together as part of a story of an imaginary what if trip to Pluto. Equipment Required 1) COMPUTER CART (on left of photo. Note this shows an older version of the computer cart 2) DEMO DESK (in center of photo) 3) MISSION SUPERCHILL STORAGE CART (on right of photo) cart containing all the props and equipment for the show. Naomi demonstrating a geyser during Mission Superchill Pluto Edition Show. On the screen on upper right, audience sees the Mission Superchill title screen.

Mission SuperChill, page 2 of 7 Close up of STORAGE CART Left Right Three PURPL E Tubs Two plastic shields & thin metal plate gloves Center Geyser flask and funnel Red Thermo s #1 Vacuum jar Large Demo Dewar Red Thermo s #2 Vacuum pump Note that face shield is stored on top of the plastic shields for the rubber ball STORAGE TUBS #1, #2 AND #3 Right: PURPLE TUB #1: Rubber ball Rubber tubing Nylon woven strap (Balloon may also be there, not used in this version of Superchill) Center: PURPLE TUB #2: Brass ball and ring Bicycle bearings Magnetic bearings Left: PURPLE TUB #3: This experiment is not used in this version of the show PURPLE TUB #3 PURPLE TUB #2 PURPLE TUB #1 Metal Tongs are located at the front of the cart by the Glass Dewar

Mission SuperChill, page 3 of 7 COMPUTER CART Right: Thermocouple and leadwire (not seen under screen). Below is the Logger Pro interface box. You should never have to make changes to this box. Camera Thermocouple (Behind screen) Centert: TV CAMERA Logger Pro Interface Box TV Camera Main Teaching Points Ordinary materials such as water can exist in three phases: solid, liquid and gas; so can nitrogen. As you move out in the solar system getting farther from the sun, planets and their moons get colder. Pluto is so cold (minus 391 deg F) that nitrogen, which makes up 80% of the air we breathe, can condense to a liquid or even freeze solid. Materials change properties at supercold temperatures, and those such as plastic and rubber can become completely useless on Pluto because they become stiff and brittle.

Mission SuperChill, page 4 of 7 Before NASA scientists and engineers send a spacecraft to places like Pluto, they will have to modify designs and invent new materials. Sometimes when you are trying to solve a problem, the best approach is to take a whole new approach rather than modifying a previously solution. NOTE about preparing to do this show Due to the safety issues related to handling Liquid Nitrogen, you must be 16 years or older to be trained to do this show Due to the safety issues related to handling Liquid Nitrogen, to do this show you must be certified by the appropriate staff member. No cross training on this show. Besides reading this Mission SuperChill s TRAINING MANUAL, you will also need to master two other documents: LIQUID NITROGEN SAFETY PACKAGE and MISSION SUPERCHILL SHOW SCRIPT. Operating Tips DO s DO bear in mind that Liquid Nitrogen is classified as hazardous material and that all safety guidelines MUST be followed at all times. NEVER do any informal experiments or unauthorized stunts. NEVER leave any LN out within reach of visitors Always keep the TIPPING CART locked when you are not physically present. Double check all show pre-sets, as there are many things if not set up properly that can spoil the continuity of the show. DO keep the show moving. It needs a brisk, but not rushed pace. DO motivate each movement or equipment change, that is, tell what you are going to do before you do it. The audience won t mind the wait as you get equipment set up since they will be excited to see what comes next. DO stick to the blocking (ie the movements of the performer and the props) as written in the script. The blocking and procedures have been carefully worked out for safety to audience, to minimize tripping and other safety hazards for the performer and to keep the show pace up. DO remember that the phenomena on display are the stars of the show; the performer is more the Master of Ceremonies than the lead. Therefore, DO allow time for audience to observe the phenomena as its happening for a moment before launching into an explanation, since the audience will be watching the phenomenon and not listening to you. DO rehearse the wording of the script, though reciting it dead letter perfect is not required. DO rehearse all aspects of the show. Otherwise, you get dead air and non-purposeful chatter. DO make sure that all audience members remains in their seats and no one comes on stage.

Mission SuperChill, page 5 of 7 DON T s DON T add unscripted material or anecdotes. The show will be too long or will drag. DON T ever take any Liquid Nitrogen off stage. DON T allow visitors on stage after the show or near the Liquid Nitrogen Dewars or any props. If you want to demonstrate something in response to a question, have visitors watch from off the stage. Operating the Tipping Cart The TIPPING CART is custom-made device to make pouring Liquid Nitrogen as safe and convenient as possible. 1) Always keep the TIPPING CART locked when you are not physically present. 2) Place the empty RED THERMOS JAR into the circular hole made for it on the lower level of the TIPPING CART. 3) Remove the cap from the 10 liter Dewar and set it on shelf. 4) Wearing protective gear, slowly and carefully tilt the box containing the 10 liter Dewar so that Nitrogen flows out at a slow steady rate. Poor small amount into thermos. 5) After initial boil off of Liquid Nitrogen, top off the level in the RED THERMOS JAR till it is about ¾ full. Place it against the wall to prevent accidental spillage. 6) Replace the cap on the 10 liter Dewar.

Mission Superchill Training Checklist Mission SuperChill, page 6 of 7 Name: Due to safety concerns, this show must be trained by a designated staff trainer. The trainers for this show are: Naomi Pequette, Christie Cass, Erin Prestia-Robins, Michael Parker, Andrew Parker, Amber Parham, Cat Jensen, Jose Zuniga. Dave Blumenstock and Naomi Pequette will work to pair volunteers with staff trainers for their shifts Preparation Liquid Nitrogen Certification with Samantha Richards or Naomi Pequette Watch staff Superchill #1 Watch staff Superchill #2 Review training material and script on Portal Training Please note there is no magic number of times each step in this process needs to be done. Please work with your staff trainer and Naomi to determine when you are ready to move on to the next step in the training process. Blocking run-through Do dry run (all show components without actually using Liquid Nitrogen) Perform individual experiments Experiment and Safety Sign-off with Naomi Tandem Show with trainer #1 (perform experiments with minimal script) Tandem Show with trainer #2 (reverse roles from first show) Perform whole set-up, show, and post-show for trainer according to all safety and script requirements (without audience and with audience) Solo Certification with Naomi (Run through set-up, show, and post show) Continuing Superchill Training Have trainer watch 2 nd solo show and give notes Have trainer watch 8 th solo show and give notes

Mission SuperChill, page 7 of 7 STAFF ONLY SECTION CHANGING THE DEWAR IN THE TIPPING CART When the Dewar reaches is empty or has less than enough LN for another show, it is time to change out the Dewar for a full one. 1. Take the SUPERCHILL key from the backstage rack. 2. Roll the TIPPING CART to the STORAGE CAGE on the loading dock. 3. Using the key hung on the TIPPING CART, unlock the padlock on the cage. 4. Make sure TIPPING CART front lock is locked and secure. 5. Remove a full Dewar from the cage and set in out of the way so it cannot be tipped over. 6. Remove the lid to the Dewar and set it inside the TIPPING CART. 7. Unlock the hasp on the handle side of the TIPPING cart, and open the lid. 8. Using both hands, lift the empty Dewar straight up and set it on the floor. 9. Replace the lid on the full Dewar. 10. Tear the tag on the Empty Dewar so it says EMPTY. 11. Place the empty Dewar inside the cage behind any full Dewars. 12. Replace padlock on storage cage. 13. Using both hands, lift the full Dewar and lower it into the TIPPING CART. 14. Close the top and secure the hasp 15. Return cart to the GALAXY STAGE, remembering to SET THE BRAKE on the TIPPING CART so it will not roll backwards while you unlock the GALAXY STAGE door. 16. Replace TIPPING CART and key to their normal palaces. 17. If you take the last full Dewar from the cage, leaving all 4 empties in the cage, call Samantha Richards and ask her to order a delivery.