MaxSB - Low Voltage Switchboard

Similar documents
Retrofitting kit New Emax Direct Replacement of Megamax and Novomax

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Project: Consultant : MEP Contractor: PREPARED BY: DORMAN SMITH SWITCHGEAR - DUBAI REVIEWED BY CONSULTANT : Page 1 of 15

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA

Miniature controls. Contactors. Overload relays. Starters. Control relays

SonoMeter 30 Energy Meters

Innovative Techniques for Mitigating Arc Flash Exposure

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

Aquavar SOLO 2 Frequently Asked Questions

Circuit breakers PR 60

Meta-MEC Manual Motor Starters

Installation, operating and maintenance Instructions for Seemag bypass level indicator

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Check with local zoning official for property line distance requirements.

3M Telecommunications Solutions for Networks. Quante QSA (= LSA plus) System Catalogue. Innovation

Medium Voltage Switchgear. Installation Manual for Pressure Relief Ducts

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

London Underground - Section 12 approved Switch Disconnectors

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Why do I need to do an Arc-Flash Analysis?

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

BUBBLER CONTROL SYSTEM

Selection of Electrical PPE Tables

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

IEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031)

Electrical Safety Program

Electrical Shore Connections

CMC Series Moulded Case Circuit Breaker Cielo Electric

CCT-7320/ROC-2313 Reverse Osmosis Controller

RPS900W Redundant Power Supply. Installation Guide.

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

TECHNICAL DATA. Trimpac 256a. October 31, 2013

Customer Responsibilities

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Field Certification Certificate of Compliance

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

SPECIFICATIONS ATTENTION

BUBBLER CONTROL SYSTEM

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

icreasepro Creaser Operators Manual

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

Pushbuttons, Indicating Light, and Rotary Switch Stations Series 4975

Appendix A: Energized Work Permit

Pressure switch Type BCP

3M InCa Individual Cross-Connection Cabinets

SyncroFlo Municipal University and Hydraulic Institute, Pump Systems Optimization

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013

Residential Swimming pools

General Requirements of the NEC Advanced Course. Building Officials and Inspectors Educational Association

INSTALLATION,OPERATION AND MAINTENANCE INSTRUCTIONS DRY AIR COOLER

Digital Melting Point Apparatus

Extension Platform. Base Platform. Crossover. Exit railing. Exit Railing

I.H.S INSTALLATION INSTRUCTIONS

[Instruments for vacuum measurement, checking and adjustment] 3

MP15 Jockey Pump Controller

Quadair. Air Hockey Table Owners Manual. Assembly operation and care instuctions. Serial # Distributed By. Sales Person. Technical Service #

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments

GV Standard X-Vent. Setup, Commissioning & Installation Guide

SUBSTATION EXPLOSION BARRY GASS HIGH VOLTAGE TRAINING. Barry Gass Training Manager High Voltage Training South Africa

Installation, use and maintenance instructions. Gas burner (5)

All Molybdenum Hot Zone & Elements. All Insulators are made of High Alumina. Element style - 1/8 Molybdenum Wire.

POWR-BLOKS Distribution/Splicer Blocks and Covers

Protection of motor circuits

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TeSys protection components

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

CUSTOM ENCLOSURE CUTOUTS

EU Declaration of Conformity

EXPLORE FLIP AND NEST COLLABORATIVE TABLE

Customer Responsibilities

HS653 Negative Pressure Ventilation Controller

Evaporator (DX) Freon Applications 1 12 Tons MHF

780S Ultra High Purity Series

Torque Tube TB300 Digital Transmitters

This presentation provides an overview of modern methods for minimizing the arc-flash hazard.

Product Overview. Product Description CHAPTER

3200 WHOLE HOUSE FAN INSTALLATION & OPERATION MANUAL

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

Lighting Contactors. 4.1 UL Rated AC Contactors

E Cube Lift Model: ECU Installation Instructions

Zelio Relays RSL Slim Interface Plug-In Relays

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

EU Declaration of Conformity

VI.D AIR DISCONNECT SWITCHES

Copeland Discus with CoreSense Diagnostics January 2011

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Gas Network Craftsperson

Cycling Device Training Manual

ski racks DESCRIPTION ADULT SKI RACK DIMENSIONS

OEM Manual. MODEL ½ Digit DRUM SCALE

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

ATTACHMENT 2 REQUIREMENTS MILLE LACS ENERGY COOPERATIVE S SCHEDULE 3 DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS TABLE OF CONTENTS.

KAL36150 Molded Case Circuit Breaker, 600VAC, 150A

Squeegee Unit for MRS Multi-Recovery System

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

Transcription:

BU 3101 Low Voltage Systems, March 2009 Low Voltage Systems MaxSB - Low Voltage Switchboard May 5, 2009 Slide 1

MaxSB Product Overview Description Value Rated Main bus current 1600A, 2000A, 3000A, 3200A, 4000A, 5000A Group Mounted Vertical bus Distribution vertical bus Rated tested maximum voltage Rated voltage 800A, 1500A, 2250A 1000A-5000A 254Vac, 508Vac, 635Vac 240Vac, 480Vac, 600Vac Phases 3 phase 3 wire, 3 phase 4 wire Neutral Frequency Short circuit current 480V Short circuit current 600V Service Entrance 100% rated 50/60 Hz 65kA, 100kA 50kA Yes (Optional) Enclosure NEMA 1 April 8, 2011 Slide 2

MaxSB Standards SWITCHBOARD UL 891 Low Voltage Switchboards CSA C22.2 No. 244-05 Canadian Standards Association ANCE NMX-J-1182/2 Association of Standardization and Certification ANCE-2006 IEEE-STD-693-2005 Seismic Qualification CIRCUIT BREAKER ANSI C37.13 LV AC Power Circuit Breakers Used in Equipment ANSI C37.16 Preferred Rating, Related Requirement, Application Circuit Protectors Recommendations For LV Power Circuit Breakers and AC Power ANSI C37.50 Testing of Low Voltage AC Power Circuit Breakers UL 1066 Low Voltage Power Circuit Breakers UL489 Standard for Molded-Case Circuit. Breakers and Circuit Breaker Enclosures CSA 22.2 Canadian standard for enclosures April 8, 2011 Slide 3

MaxSB Market Segments Oil and Gas Mining and Metals Utility and co-generation Steel Mill Critical power Pharmaceutical Waste Water Generator Manufacturing Oil and gas Power Generation Food and Beverage Aerospace Critical Power and Data Centers Industrial facilities April 8, 2011 Slide 4 Utilities

MaxSB Offerings Hinged door, large wire ways save time and money in field wiring. Plated copper bus used in all three phases and neutral. Copper ground bus extends full width of switchboard. Horizontal bus up to 5000A Vertical bus up to 2250A April 8, 2011 Slide 5

MaxSB Structure Standard Textured Paint Finish RAL7035 Frame is made of Turati ArTu-K made of zinc coated steel of thickness 1.5 mm Frame is reinforced with #12 ga galvanized supports Frame is secured on corners by a three way aluminum joint Shipping base is four inches high #12 ga galvanized steel All switchboards are shipped on wooden pallets Maximum shipping split is 78 Four inch base is standard 92 Height Lifting eyes on roof April 8, 2011 Slide 6

MaxSB Dimensions - Widths April 8, 2011 Slide 7

MaxSB Dimensions - Depths April 8, 2011 Slide 8

MaxSB Covers and Doors All doors and covers are painted RAL 7035 Side panels and rear panels are #16 ga galvanized steel Top panel is #14 ga steel Group mounted door and breaker covers are #16 ga steel and is locked by door handle Emax breaker doors are #14 ga thickness and are secured by screws April 8, 2011 Slide 9

MaxSB Layouts Main and Tie Sections Amperage (A) Dimensions Frame Size Width Depth Line/Load Lug Information Quantity (per phase) Size (kcmil) Mechanical 800 2 1200 3 28.3 33 1600 E3 4 (720mm) (840 mm) 2000 5 2500 6 3000 37 33 8 E4 3200 (940 mm) (840 mm) 8 4000 44 41 10 E6 5000 (1120 mm) (1037 mm) 12 #2-600 April 8, 2011 Slide 10

MaxSB Layouts Emax Feeder Sections The MaxSB can provide stacked feeder sections up to 2000A using fixed or drawout type Emax power circuit breakers (UL1066). Each circuit breaker is located behind a hinged door secured by screws. The MaxSB utilizes only the E3 frame size. Amperage (A) Dimensions Frame Size Width Depth Line/Load Lug Information Quantity (per phase) Size (kcmil) Mechanical 800 2 1200 28.3 33 3 E3 1600 (720mm) (840 mm) 4 2000 5 #2-600 April 8, 2011 Slide 11

MaxSB Layouts Group Mounted Sections Breaker are mounted by bus straps Bus straps are covered with electrical tape holes on vertical bus allow for mounting of breakers at different location Incoming can be main lug or single main for single group mounted sections 3P4W require depth of 33 (840mm) Single group mounted can be 15 (385 mm) deep 3000A requires an incoming pull section April 8, 2011 Slide 12

MaxSB Layouts Group Mounted Sections For 2500A and 3000A sections an incoming pull section is required Only uses Tmax breakers April 8, 2011 Slide 13

MaxSB Layouts Pull Sections 28.3" 37" 40" Instrument Compartment Instrument Compartment Instrument Compartment 92" April 8, 2011 Slide 14

MaxSB Horizontal Bus Design Horizontal bus ratings: 1600A, 2000A, 3000A, 3200A, 4000A, and 5000A Short Circuit Current: 100 ka (3 Cycle Rating) Silver-plated standard with option for tin-plated Location is top, bottom, or middle depending on incoming and application April 8, 2011 Slide 15

MaxSB Group Mounted Vertical Bus Design April 8, 2011 Slide 16 Vertical bus ratings: 800A, 1500A, and 2250A Short Circuit Current: 65 ka without main breaker Group mounted feeder breakers ranging from 15 amps to 1200 Amps Silver-plated standard with option for tin-plated Vertical bus is slotted to allow adjustability for mounting location of molded case breakers 52 high interior available for mounting of breakers

MaxSB Group Mounted Vertical Bus Design 1P 1P 2.06 in T1 100 Amp 2/3 Pole 2/3 Pole 4.13 in T2 100 Amp 52 of available space 2/3 Pole 2/3 Pole 4.13 in T3 225 Amp 2/3 Pole 2/3 Pole 4.13 in TS3 225 Amp 2/3 Pole 4.13 in T4 250 Amp 3 Pole 5.51 in T5 400 Amp 3 Pole 5.61 in T4/T5 400 Dbl 2/3 Pole 8.27 in T6 800 Amp T7 1200 Amp 36" Wide Structure April 8, 2011 Slide 17

MaxSB Group Mounted Sizing Section Example: 2 - T2 40A 1 T6 600A 2 T4 200A 2 T5 400A Total amperage sum = 1888A Total number of breakers = 7, reduction percentage = 60% Therefore total available current = 1888 X.6 = 1128A, therefore 1250A vertical bus is required April 8, 2011 Slide 18

MaxSB Ground Bus Design Single group mounted sections: ¼ x 2 bare copper All other types of sections: ¼ X 4 bare copper One TA600-NS lug per section is provided as standard, others may be added upon request April 8, 2011 Slide 19

MaxSB Barriers Instrument mounting panels are used for mounting electrical equipment and as barriers to isolate electrical components from the main bus when accessing through the front. Optional glastic or steel barriers are available between each section to segregate each section completely. When service entrance is required, the MaxSB will incorporate all appropriate service entrance barriers. April 8, 2011 Slide 20

MaxSB Emax Power Circuit Breakers 800-5000 Amps Frame Sizes: E3, E4, and E6 Fixed/Drawout Electronic Trip Compact Size High Interrupting Rating Extremely High Mechanical & Electrical life April 8, 2011 Slide 21

MaxSB Emax Power Circuit Breaker There are three types of trip units available PR121 Protection Features Only PR122 Protection Features LCD Display Current Measurement Contact Wear Communications option PR123 PR122 Features Harmonic Measurements Communications option April 8, 2011 Slide 22

MaxSB Emax Power Circuit Breaker PR121P Trip Unit LED Display LSIG Protection Wireless communication by means of the BT030 adapter unit plugged in the front April 8, 2011 Slide 23

MaxSB Emax Power Circuit Breaker PR122P Trip Unit LCD Display LSIG Protection Phase unbalance protection U Zone discrimination for S and G protection Self-diagnosis Data Logging Modbus Communication Measurement function April 8, 2011 Slide 24

MaxSB Emax Power Circuit Breaker PR123P Trip Unit LCD Display LSIG Protection Double selective S and G function Phase unbalance protection U Zone discrimination for S and G protection Self-diagnosis Data Logging Modbus Communication Measurement function Harmonic calculation up to the 40 th harmonic April 8, 2011 Slide 25

MaxSB Emax Power Circuit Breaker There are multiple modules that can be incorporated in the PR122 and PR123 trip units PR120/V Measurement Module Provides voltage, data logging, power, power factor, frequency, energy, UV, OV, RV, Reverse power protection, and frequency protection PR120/K Electrical Signaling Module Provides remote signaling of alarms and trips of breaker and can be provided with a digital input enabling external trip, activation of alternate set of parameter, trip reset, and reset of PR120/K power relays PR120/D-M Modbus Communication Module Provides Modbus Communication to PR122 and PR123 trip unit PR021/K Signaling Unit Converts digital signals by PR121, PR122, and PR123 into electrical signals. (overload pre-alarm, timing and tripping of protections, overtemperature, trip unit tripped, dialogue fault on serial line, and phase unbalance) April 8, 2011 Slide 26

MaxSB Emax Power Circuit Breaker Breaker Electrical Contacts Aux Contacts: 4, 10, and 15 TOC Contacts: 5 and 10 Sliding Contacts Contacts for signaling closing springs charged Contacts for signaling undervoltage release April 8, 2011 Slide 27

MaxSB Emax Power Circuit Breaker Breaker Electrical Accessories Shunt Trip Second Shunt Trip Charging Motor Bell Alarm Undervoltage Release April 8, 2011 Slide 28

MaxSB Emax Power Circuit Breaker Breaker Mechanical Accessories Operation Counter Circuit breaker lock in racked-in/test isolated/racked-out position Key locking provisions Padlock provisions Button Guard April 8, 2011 Slide 29

MaxSB Tmax Molded Case Breakers Frame sizes from T1-100A to T7-1200A Thermal Magnetic or Electronic Trip Units Fixed Mounted Double insulation provided between live power parts and the front of the apparatus preventing any risk of contact Interrupting rating up 100kA April 8, 2011 Slide 30

MaxSB Tmax Molded Case Breakers Four types of Trip Units for T1- T6 Thermal Magnetic PR221DS LI PR222DS/P LSI PR222DS/PD-A LSIG Four types of Trip Units for T7 PR231/P LI PR232/P LSI PR331/P LSIG PR332/P LI, LSI, LSIG April 8, 2011 Slide 31

MaxSB Tmax Interrupting Ratings April 8, 2011 Slide 32

MaxSB Tmax Molded Case Breakers Multiple Common Accessories between each frame Undervoltage Release Shunt Trip Closing Coil Aux Contacts Charging Motor April 8, 2011 Slide 33

MaxSB Instrumentation and Metering Door mounted lights, meters and control ABB Indicating Lights Volt, amp, and watt meters Electroswitch Series 20 and 24 control switch Multifunction Metering Electro Industries Others (optional) Relays ABB (provided standard when required) Others (Optional) Surge Protectors APT or ABB TVSS (Standard) Others (Optional) April 8, 2011 Slide 34

MaxSB Accessories Lift Truck for removing of Emax power breakers Breaker test cabinets for testing Emax breakers PR010/T portable test unit for all breakers April 8, 2011 Slide 35

MaxSB Applications Main-Tie-Main transfer schemes (open and close) ABB standard only Kirk Key Interlock April 8, 2011 Slide 36

MaxSB Arc Flash Safety Options - Maintenance Switch Used to manually change the circuit breaker s Instantaneous protection settings to a preprogrammed set of values by means of a door mounted switch. Used when the customer requires a faster tripping time when personnel are working in and around the switchgear. The circuit breaker stores preset values (Value A = Normal and Value B = Maintenance ) with regards to the instantaneous settings. These values are determined by the customer and programmed into the circuit breaker trip unit. Normal values are specified for regular operation of the switchgear, Maintenance values are specified for when work is being performed on the switchgear. Note: Only offered in Emax sections April 8, 2011 Slide 37

MaxSB Arc Flash Safety Options - REA Relay Minimizes material damage to switchgear, enables quick restoration of the power distribution and guarantees improved personnel safety. Detects an arc anywhere in the bus compartment and cable compartment utilizing long-fiber sensor system. Total reaction time is less than 2.5ms plus Emax breaker opening time. Uses a fiber optic cable wired through the bus compartment and cable compartment in order to detect an arc flash. It then feeds signal to an REA relay which verifies current change on the incoming main bus by the use of CT s. If a change is detected by the relay along with a signal from the fiber optic cable the relay will then send a signal to the main breaker in the corresponding bus to trip, therefore opening the corresponding bus. Note: Only offered in group mounted sections April 8, 2011 Slide 38

MaxSB Features and Benefits Strong frame construction isolates bus and breaker assemblies from enclosure skin. Unique bus layout delivers the freedom to locate feeder breakers independent of any hole pattern. Optional barriers for increased personnel protection Hinged door, large wire ways save time and money in field wiring. Standard connections to a full range of ABB products Modbus Communication Transfer Schemes April 8, 2011 Slide 39

MaxSB Competitive Aspects Competitive Footprint Stability and strong structure Emax breaker Trip Units PR121P, PR122P, and PR123P Safety Features Tmax breakers Multiple frame sizes with common accessories Communication Capabilities (SCADA, Modbus, Ethernet, etc.) April 8, 2011 Slide 40

Visit us at www.abb.com/us