Accu-Tab PowerBase 3070AT by Axiall Corporation

Similar documents
Accu-Tab PowerBase 3140AT by Axiall Corporation

Accu-Tab PowerBase 3012AT by Axiall Corporation

Accu-Tab Systems 1000 Series by Axiall Corporation

Accu-Tab Systems 2000 P Series by Axiall Corporation

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

ECONOMY POOL SUNSHINE IONIZER MODEL SPE INSTALLATION INSTRUCTIONS

Vessel Installation and Operating Manual

Installation and Operating Manual

Saline C 6.0 Junction Box

PURITY INSTALLATION INSTRUCTIONS MODEL P40

Operator's Manual. Model #PS Arch Chemicals, Inc Lake Park Drive Smyrna, GA PULSAR

Installation Instructions JATCO Environmental Protection Tank Model J-7000

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

PC1131 Electric Air Compressor

Arch Feeder: Operator s Manual

Operating Manual. Model BAC-30RT30/BAC-30DC

PoolNaturally. Pure. Simple. Genius. Installation and Product Use Instructions In ground and above ground pools

Installation and Operating Instructions

FLANGED TWO-PIECE BALL VALVES

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

ACCU-MIX 1200 / / 26270

J Air and Water Kit Instructions Part# 02584

FLANGED TWO-PIECE BALL VALVES

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

INSTALLATION AND OPERATION INSTRUCTIONS

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

HIGH PERFORMANCE POOL & SPA PUMPS

D Series Air and Water Kit Part# 02550

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

FLANGED MULTI-PORT BALL VALVES

480C DUAL PERFORMANCE VALUE PACK

There are no NSF-certified substitutes for Accu-Tab 3-inch Blue and Blue SI (scale inhibitor) Tablets.

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

1. Introduction Part One The business... 2 Part Two The benefits... 3

Marschalk Model # 94000

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

BS Series Basket Strainer

1 Pound Treats Between 10,000 to 15,000 Gallons. 24 x 1lb. pouches

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

200 PSI COMPRESSORS - MODEL NUMBERS

Cocoa Patio Pond with Lit Spillway

Model TWBS.SH Tempered Water Blending System

1020 Industrial Drive, Orlinda, TN fax

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

Installation, Operation and Maintenance Manual

HAS2400 Hepa Air Scrubber

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Light Commercial Reverse Osmosis System. EE-1000 Manual

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING

INSTALLATION AND OPERATION INSTRUCTIONS

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

444C DUAL PERFORMANCE VALUE PACK

SERVICE BULLETIN This service bulletin is for Accu-Tab Blue Calcium Hypochlorite Tablets (EPA Reg. No )

Model Portable Eyewash

100C Air Compressor Kit

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

KJ4000 Operating Instructions & Parts Manual NSN

3" Chlorinating Tablets Controls Bacteria and Algae Growth Does Not Contain Stabilizer One Tablet Treats 10,000 Gallons of Water for Up to Seven Days

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

ULTRA QUIET & OIL FREE

INSTALLATION AND OPERATING INSTRUCTIONS

Owner s Manual W Automatic Aboveground Pool Cleaner

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

FloWash. Industrial Filter Cart

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

92831 TEL: (714) FAX:

Swimming Pool IAQUALINK WEB CONNECT

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

IMPORTANT SAFETY INSTRUCTIONS

2 Gallon Air Compressor

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Nature 2 Vision Pro Cartridge Back Label (H )

SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process

KJ1000 Operating Instructions & Parts Manual NSN

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

4-in-1 Professional Inflator Kit

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

Installation & Instruction Manual For Portable Series R.O. units:

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

IMPORTANT SAFETY INSTRUCTIONS

453 Series Steam Heated Vaporizing Regulator

Waste Management System.

VAC-U DRIVE Swinging float arm for Acrobat like agility 36 Fin disk with DEEP VEE Scoop

Transcription:

Accu-Tab PowerBase 3070AT by Axiall Corporation Installation and Operating Instructions The PowerBase 3070AT Chlorinator is NSF STD 50 NSF-Listed for pool applications. ONLY Axiall Corp. Accu-Tab Blue SI Tablets for commercial pool applications are permitted for NSF installations. Use of tablets will void NSF certification. DANGER: DO NOT MIX CHEMICALS! The PowerBase 3070AT chlorinator system is designed for use with Axiall Corp. approved tablets only. Do not use Cal-Hypo tablets with stabilized chlorine or bromine products, or other sanitizing chemicals. Fire or explosion could result. Rev 06/11/15

Description The Accu-Tab PowerBase 3070AT chlorination system incorporates a patented Axiall Corporation chlorinator into a compact plug and play system. Included in the system is an integrated, level controlled solution tank and a centrifugal pump. The flow rate through the system is controlled by a manually adjusted valve located on the discharge of the pump. The solution tank level is controlled by a float valve. As solution is pulled from the tank, the float valve opens allowing water to flow to the chlorinator, contacting the tablets, and then draining into the solution tank. Overflow protection is standard. Two level switches in the top area of the Solution Tank (4 apart) will flip a latching relay in the electrical box causing the pump to turn on/off as needed. The chlorination system is designed for use ONLY with Axiall Accu-Tab Blue SI tablets utilizing the Axiall erosion feeder technology that erodes only the bottom layer of tablets on the sieve plate, while keeping tablets above the sieve plate dry and ready for use. Tablets other than Axiall Accu-Tab Blue SI tablets will have different delivery rates, resulting in improper chlorine delivery. 2

Installation Instructions 1. Place the chlorination system in a location near the place of application. 2. Level the system. This is important for proper chlorine delivery. 3. Connect the inlet flow meter assembly to the solution tank. The parts were shipped separately to prevent breakage in shipping. 4. Connect the inlet water supply with 1-1/2 PVC pipe or hose. Include an isolation valve in the line. 5. Connect the discharge assembly to the pump using a section of 1-1/2 pipe. (The parts were shipped loose to prevent breakage in shipment.) 6. Connect the discharge piping from the feeder to the chlorine application point with 1-1/2 PVC pipe or hose. Include an isolation valve in the line. 7. Plug the power cord into an 120v receptacle. 3

8. If a chemical controller is utilized, plug the controller cord into the controller s 120v switched output. NOTE: IF A HIGH PRESSURE WEBTROL PUMP IS ORDERED, A LARGER CAPACITY PUMP CONTACTOR IS INSTALLED IN THE ELECTRICAL BOX AND NO CORD/PLUG IS PROVIDED AS A 25 AMP CIRCUIT IS REQUIRED. 4

Chlorine Delivery (lbs/hr) 10 8 Model 3070AT Using Accu-Tab Blue and Blue SI Tablets For pool use only 6 4 2 NSF 0 Standard 50 0 2 4 6 8 10 12 14 16 18 20 Flow Through Chlorinator (gpm) Start Up 1. Close the discharge gate valve. 2. Open the feed and discharge isolation valves. Water will begin to fill the solution tank. 3. When water stops flowing, switch the system ON using the chemical controller. The pump will circulate water through the blue tubing. 4. Begin opening the discharge gate valve to start flow in and out of the system. 5. Determine the maximum inlet flow rate by continuing to open the discharge gate valve in small increments. Remember to allow a few minutes each time to allow the flow meter to stabilize. If pump loses prime, maximum inlet flow has been exceeded. Shut down system for a few minutes (which will prime the pump), close back on the discharge gate valve and restart the system. Continue this process until the maximum inlet flow is determined. 6. Adjust flow through feeder using the discharge gate valve. The chlorine delivery is determined by the flow rate through the chlorinator. Use the graph above to determine proper flow rate. NOTE: After adjusting the discharge valve, the flow meter will take a few moments to stabilize. 7. Check all piping for leaks. 5

Operation 1. Remove lid from chlorinator and fill with the appropriate amount of Accu-Tab Blue SI tablets. Add no more than the amount of tablets that will be used within one week. 2. Check pool water for desired chlorine level and adjust flow through chlorinator as needed. NOTE: When pool water circulation stops, flow to chlorinator will stop. This will stop chlorine delivery. Adding Tablets 1. Tablets may be added while the system is running. Take care to protect eyes, skin, clothing and other equipment from splashing. Do not inhale fumes. 2. Remove lid and add Accu-Tab Blue SI tablets. 3. Replace lid. Maintenance Clean the Check Valve and Float Valve at least every 4-6 months, or as needed, to remove scale or debris Winterizing 1. Clean chlorination system following instructions below. 2. Close inlet isolation valve and operate pump until no more water can be pumped out. 3. Shut system down and close the outlet isolation valve. 4. Siphon any remaining water from the solution tank. 5. Remove any debris from the chlorinator or solution tank. 6. Open the bottom drain on the pump. 7. Drain water from feed and discharge lines. 8. Make sure no water remains in the pump, chlorinator, pipe line, or solution tank to prevent freezing over the winter. 6

System Cleaning Over time the chlorination system may develop a build-up of scale. This should be cleaned on a periodic basis, up to twice per year. If scale formation is severe, more frequent cleanings may be necessary. Cleaning may be accomplished by soaking the chlorinator with a dilute acid solution according to the instructions below. NOTE: Addition of muriatic acid may lower the ph of the pool water Preparation for cleaning 1. Prepare 2 gallons of muriatic acid. 2. Always use appropriate safety equipment while servicing the unit or handling chemicals. 3. Clean the feeder in a well-ventilated area. Chlorine gas may be released during the cleaning process! Cleaning procedure 1. Turn system off. 2. Open lid and remove all tablets. Use proper protective equipment when handling chemicals. 3. Switch system on to begin flushing the system. 4. Wash out the feeder with a hose to remove remnants of tablets and loosen scale. 5. Operate system until normal solution tank level is achieved. Switch system off. 6. Close inlet and outlet isolation valves. 7. Very carefully, pour the acid into the upper chlorinator to dissolve scale. It may be necessary to pour directly on the inside walls to remove any scale above the water level. Always add acid to water, never add water to acid. 8. Let soak for 30 minutes. As acid dissolves scale, carbon dioxide will be released, and foaming will occur. If any tablets were left in the feeder, chlorine gas may also be released. 9. Turn system on to start acid circulation through the blue tubing. Circulate for 10 minutes. 10. Open all valves to begin purging acid from system. 11. Wash the walls and sieve plate of the feeder with a hose to remove all acid residue. Chlorine gas may be released if any acid remains in the system. 12. Allow feeder to flush water for 30 minutes. 13. Turn system off. System is ready for operation. 7

Troubleshooting System overflows. 1. Debris in the float valve. 2. Debris in the check valve. 3. Float valve stuck in down position. Clean float valve. Pump will not run. 1. Check power supply and connections, and controller 110v signal. 2. Check for 110 voltage across terminals #2 and #5. If voltage present, wiring or pump motor failure. Pump loses prime (solution tank drains) 1. Maximum inlet flow exceeded. See Start-Up instructions point #5. Electrical Drawing Base System 8

If a controller is not used, remove controller cord and install jumpers between: Terminals #1 and #4 Terminals #2 and #6 If a chemical controller is not used, remove control cord and install jumpers between: Terminal #1 & #4 Terminal #2 & #7 The controller cord should be removed. Electrical Drawing HHL Pump Switch 9

Discharge Pressure, psi Hayward Pump Performance PurAqua Part #: PAPP1500 Pump Frame: R48Y Amp rating: 15 amps Flow, gpm PowerBase Replacement Parts PurAqua Part # Axiall Part# Hayward 1 ½ HP Pump PAPP1500 9500080 Seal for Hayward Pump SPX1250XZ2C Webtrol 1 ½ HP Pump PC150R 9500185 Option Seal for Webtrol Pumps 70X130-M Option Pump Contactor NC1-1810-120V 9500145 1 Inline Flow Meter F-41000LN-16 9500008 Level Switch M8710 9500084 Option 1 ½ Discharge Swing Check Valve S1720C-15 9500077 1 Gate Valve GVG-1000-S 9500011 1 ½ Inlet Filter 1-1/2-60-F 9500000 1 Kerick Float Valve PS-100SS 9500007 For other questions, contact Axiall Technical Service (855-934-3570) for assistance 10

CAL-HYPO COMMERCIAL SYSTEM LIMITED WARRANTY Axiall Corporation ("Axiall") warrants (subject to the below conditions) only its title to this water treatment system equipment (the "System") and that the System will be free of defects in materials and workmanship for a period of twelve (12) months from its original installation date. THIS IS THE ONLY REPRESENTATION OR EXPRESS WARRANTY THAT AXIALL MAKES AND ALL OTHER EXPRESS WARRANTIES UNDER STATUTE OR ARISING OTHERWISE IN LAW FROM A COURSE OF DEALING OR USAGE OF TRADE WITH RESPECT TO THE SYSTEM ARE DISCLAIMED. ANY IMPLIED WARRANTIES EXISTING AS A MATTER OF LAW SHALL NOT EXCEED THE DURATION OF THIS LIMITED WARRANTY. IN THE EVENT THE SYSTEM FAILS TO CONFORM TO THIS WARRANTY, AXIALL'S EXCLUSIVE OBLIGATION AND YOUR EXCLUSIVE REMEDY SHALL BE LIMITED TO, AT AXIALL'S OPTION, THE FURNISHING OF NEEDED REPLACEMENT PARTS OR THE FURNISHING OF A NEW SYSTEM (BUT THIS DOES NOT INCLUDE INSTALLATION OR THE COSTS FOR INSTALLATION). EXCEPT AS PROVIDED IN THE IMMEDIATELY PRECEDING SENTENCE, IN NO EVENT WILL AXIALL BE LIABLE UNDER ANY THEORY OF RECOVERY (WHETHER BASED ON NEGLIGENCE OF ANY KIND, STRICT LIABILITY OR TORT) FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES IN ANY WAY RELATED TO ANY USE MADE OF THE SYSTEM. Warranty Conditions. This Limited Warranty shall apply and be effective only if: (i) the Axiall Chlorinator Warranty Registration information has been completed within thirty (30) days of the customer s receipt of the system via the Internet at http://www.accu-tab.com/warrantyregistration.aspx; (ii) the System is installed and operated and maintained in accordance with this manual and the instructions accompanying the System; (iii) you, at your cost, promptly return the System or defective part to such location as may be specified by Axiall; and, (iv) only Axiall's Accu-Tab Blue SI calcium hypochlorite tablets are used in the System. If any of these conditions are not met, this Limited Warranty will not apply and you acknowledge and agree that your purchase of the System will be on an "AS- IS" basis without any warranty of any kind whatsoever having been provided by Axiall. You assume all responsibility and risk and liability arising from: (i) the unloading, installation, storage, handling and use of the System, including use thereof alone or in combination with other materials; (ii) the improper functioning or failure of unloading, installation, transportation or storage equipment you use, whether furnished or recommended by Axiall or not; and, (iii) the failure to comply with laws, rules and regulations governing storage, unloading, installation, handling, and use of the System. You will indemnify, hold harmless, and defend Axiall from and against any claim, suit, damage, cost, expense, fine, liability, or cause of action whatsoever, including reasonable attorney fees, on account of relating to, or arising out of the use, possession, installation or resale of the System. This Limited Warranty gives you specific rights, and you also may have other rights, which vary from jurisdiction to jurisdiction. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. 11