DEFENSE LOGISTICS AGENCY LAND AND MARITIME P.O. BOX 3990 COLUMBUS, OHIO

Similar documents
MIL-STD-883K w/change 2 METHOD SEAL

Inadequacy of traditional test methods for detection of non-hermetic energetic components

Bonding Reliability Testing for Wafer Level Packaged MEMS Devices

Implication of Multiple Leak Tests and Impact of Rest Time on Avionic Hybrids

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 215, RESISTANCE TO SOLVENTS

Eliminating Gross Leakers by Seal Processing for Lowest Leak Rates per MIL-STD-883 TM 1014 Seal

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 215, RESISTANCE TO SOLVENTS

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 112, SEAL

A Practical Guide to TM 1014 (Seal)

IN-PLACE DENSITY WAQTC FOP AASHTO T 209 (16)

The Helium Leak Detector

MILITARY SPECIFICATION. CARTRIDGE 5.56mm, BALL, M855. MIL-C-63989C was inactivated after 15 September 1996 For New Design.

ASPHALT WAQTC FOP AASHTO T 209 (12)

RESISTANCE OF COMPACTED ASPHALT MIXTURE TO MOISTURE INDUCED DAMAGE (Kansas Test Method KT-56)

Regulatory Concerns for Leakage Testing of Packagings with Three 0-Ring Closure Seals

DETAIL SPECIFICATION VALVES, EXPANSION, THERMOSTATIC, REFRIGERANT-12 (R-12) AND REFRIGERANT-22 (R-22) Inactive for new design after 1 April 1996.

Air Removal from the Sterilization Chamber

MIL-STD-202G METHOD 112E SEAL

MIL-STD-883H METHOD EXTERNAL VISUAL

DETAIL SPECIFICATION HOSE ASSEMBLIES, ELASTOMERIC HYDRAULIC FLUID, FUEL, AND OIL RESISTANT, GENERAL SPECIFICATION FOR

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

~ goss7-- OSTI RECEIVED LEAKAGE TESTING OF PACKAGINGS WITH THREE-O-RING CLOSURE SEALS. c=t) SUMMARY INTRODUCTION

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

Sterile Visual Flow Indicator

Gas and Moisture Transport through Non-Hermetic Glass-to-Metal Bridge- Wire Initiator Seals

SAES Packaging service. making innovation happen, together

Seal Processing for Lowest Leak Rates and the New MIL-STD-883 TM 1014 Seal

Hermetic Cover Seal Process Technology MIL-STD-883 TM 1014 Seal

QUALIFICATION TESTS FOR A TYPE B (U) PACKAGE

Variable Leak Rate Phenomena in Glass to Metal Seals

Training Workshop «DO160/ED14» - Jessica France

The Original 24/7 PMO Valve and 24/7 PMO Tank Valve. The only way to non-stop production. GEA Mechanical Equipment / GEA Tuchenhagen

Cable Pressurization Buffering

WHP Operations and Methods { July William M. Smethie, Jr. Lamont Doherty Geological Observatory Palisades, New York U.S.A.

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

TOPIC: KNOWLEDGE: K1.01 [2.5/2.7] An atmospheric pressure of 15.0 psia is equivalent to... A psig. B psig. C psig.

Aug 17, 2001 LAB MANUAL MAXIMUM SPECIFIC GRAVITY (RICE VOIDS TEST) OF PAVING MIXTURES AASHTO Designation T 209 (Mn/DOT Modified))

Hygienic Bubble Trap Installation and Operations Manual

Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers

May08 Rev B

DEPARTMENT OF DEFENSE 1. THE FOLLOWING PAGES OF MIL-STD-202G HAVE BEEN REVISED AND SUPERSEDE THE PAGES LISTED:

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

IC67 - Pre-Instructional Survey

BULK SPECIFIC GRAVITY AND UNIT WEIGHT OF COMPACTED HOT MIX ASPHALT (HMA) (Kansas Test Method KT-15)

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List

How to specify a product. Process Sensors and Mechanical Instruments

PERFORMANCE SPECIFICATION SHEET MICROPHONE ASSEMBLY, M-169A/AIC

v. Size shall be specified on drawings.

Succeeding with Production Air Leak Testing Methods. Paul Chamberlain President, CEO

Operating Procedures for Metal Evaporator I

STANDARD OPERATING PROCEDURE

OBJECTIVE 22: EMERGENCY WORKERS, EQUIPMENT, AND VEHICLES - MONITORING AND DECONTAMINATION

INSTALLATION & MAINTENANCE INSTRUCTION

MILITARY SPECIFICATION POWDER, BLACK

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

OBJECTIVE 6: FIELD RADIOLOGICAL MONITORING - AMBIENT RADIATION MONITORING

Chamber Test Testing Theory

ONEIDA RESEARCH SERVICES, Inc.

rd Quarter Continuing Education Hazardous Materials Defensive Actions/ Emergency Decon

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

VACUUM TESTING PRECAST CONCRETE MANHOLES

TABLE OF CONTENTS PART 2 - CONFINED SPACES

II. Table C, column 20, additional requirement number 12 for UN 1280 and UN 2983: Table C column 20 mentions additional requirement/remark #12:

THERMODYNAMICS OF A GAS PHASE REACTION: DISSOCIATION OF N 2 O 4

Liquid Penetrant Procedures TABLE OF CONTENTS

IDEM Indiana Department of Environmental Management Office of Land Quality P.O. Box 6015 Indianapolis, IN OLQ PH: (317)

NSPS SUBPART Ka Check-off Form JULY 11, LAFAYETTE ROAD NO., ST. PAUL, MN

Marshall Municipal Utilities CONFINED SPACE ENTRY Effective January 1, 2011

Best Practices for Installation of Gaseous Sample Pumps

Florida Method of Test for MEASUREMENT OF WATER PERMEABILITY OF COMPACTED ASPHALT PAVING MIXTURES

6900 Maintenance Instruction System Flush

3M Steri-Vac Sterilizer/Aerator GSX Series. For Life Science Applications. Product. Profile

MILITARY STANDARD INTERFACE STANDARD FOR SHIPBOARD SYSTEMS SECTION 106 COMPRESSED AIR SERVICE FOR SURFACE SHIPS

PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, ARGON

Standard Operating Procedure Porosity Analyzer - The Micromeritics Tri-Star II (surface area) with Micrometrics VacPrep 061 (Sample Degas System)

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

LABORATORY SAFETY SERIES: Laboratory Hoods

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

PERFORMANCE SPECIFICATION PROPELLANT, OXYGEN

Experiment 13 Molar Mass of a Gas. Purpose. Background. PV = nrt

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

ASSE International Product (Seal) Listing Program

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Are Detonator Qualification and Lot Acceptance Test Requirements Rational?

Two coats are normally recommended. Some service may require mils DFT

User's Manual. MixRite TF 10. Edition 05.08

Downloaded from

Smart Water Application Technologies (SWAT) TM

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Damage Tolerance Inspection Methodology for Slow Crack Growth Metallic Structure

the annulus between the second casing string and the surface casing [must be] open to the atmosphere in the manner described in subsection (2).

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS!

OPERATING INSTRUCTIONS Sherlock Chamber Testing System

HCMTCB ASPHALT CERTIFICATION KEY ELEMENTS LIST

VACUUM CHAMBER MANUAL

PERFORMANCE SPECIFICATION VALVE; AIRCRAFT, PNEUMATIC, HIGH-PRESSURE CHARGING

OFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS

Transcription:

DEFENSE LOGISTICS AGENCY LAND AND MARITIME P.O. BOX 3990 COLUMBUS, OHIO 43218-3990 January 6, 2016 MEMORANDUM FOR VAI (LSA) SUBJECT: Dated Engineering Practices Study To Solicit User Input To Determine Whether A Proposed Modification To Add A Vacuum Aided Dye Detection Examination To The Radioisotope Wet Gross Leak Test Should Be Added To MIL STD 750 1, Test Method 1071, Condition A. Project Number 5961 2015 080. The findings and recommendations on Engineering Practices Study, dated 6 January 2016, are enclosed. The point of contact for this document is Mr. David Corbett, DLA Land and Maritime, VAC, Post Office Box 3990, Columbus, OH 43218 3990. Mr. Corbett can also be reached at 614 692 0526/DSN 850 0526, or by facsimile 614 693 1642/DSN 850 6939, or by e mail to: david.corbett@dla.mil. / Signed / THOMAS M. HESS Chief Active Devices Branch

ENGINEERING PRACTICE STUDY PROJECT NUMBER: 5961 2015 080 TITLE: MIL STD 750 1, TEST METHOD 1071v14, CONDITION A PROPOSED MODIFICATION TO ADD A VACUUM AIDED DYE DETECTION EXAMINATION TO THE RADIOISOTOPE WET GROSS LEAK TEST 6 JANUARY 2016 FINAL REPORT Prepared by: David J. Corbett DLA VAC

I. OBJECTIVES: The objective of this EP study was to solicit user input to determine whether the proposed vacuum aided dye detection visual examination step to the radioisotope wet gross leak test should be incorporated into condition A of test method 1071 of MIL STD 750 1. II. BACKGROUND: Test condition A of test method 1071 of MIL STD 750 1 cover the requirements for determining gross leak rate using a wet 85 Kr radioisotope procedure. This test condition is currently limited to device packages with an internal free cavity volume less than 0.05cm 3. The following issues with the current requirements have been identified: 1. When batch testing, isolating gross leakers can be difficult. 2. Leak path size and orientation can reduce the amount of red dye present within the device cavity. Without adequate red dye within the device cavity, the 85 Kr gas will not getter effectively; which can lead to test escapes. 3. False failures The test procedure modifications being proposed are designed to increase the detection of gross leakers. The current condition A test procedure includes the following steps: 1. Device immersion and pressurization in red dye penetrant. 2. Red die penetrant removal from device(s) exterior (acetone cleaning). 3. Visual examination for evidence of red dye exiting from leaking device(s). 4. 5. 85 Kr/air mixture pressurization. 85 Kr reading utilizing a well crystal counting station. A vacuum aided inspection step is being proposed between steps 3 and 4 above (between steps 1 and 2 in the test method). After visual examination for red dye; the device(s) shall be placed (lid down) on a white surface and evacuated in ambient air to 26 inches Hg for ten minutes. This additional step in the test sequence will detect any gross leakers via a red dye ring on the white surface. The summary of condition A issues (attachment 1), justifying examples (attachment 2) and proposed modification (attachment 3) to condition A are included. III. RESULTS: An initial draft of the EP Study project was posted on the DLA Land and Maritime website. Inputs were solicited from all currently listed parties on DLA Land and Maritime s FSC 5961 stock class email distribution list, which included military services, manufacturers, original equipment manufacturers, and the user community. No records of any response or interest are available to support the addition of the proposed methodology. IV. CONCLUSIONS: The results of this EP Study do not support the addition of the proposed methodology covering the vacuum aided dye detection visual examination step into condition A of test method 1071 of MIL STD 750 1. V. RECOMMENDATIONS: Work with all interested parties to create another proposal that warrants justification for adding the proposed methodology.

ATTACHMENT 1 RADIOISOTOPE WET GROSS LEAK TEST PROCEDURE ISSUES 1. Isolating gross leakers in a batch of devices is difficult when red dye effervescences. If a failure is missed during the initial visual inspection screening it will be more difficult to identify a gross leaker during the second visual inspection due to cross contamination. 2. Depending on the free internal cavity volume, orientation and size of the gross leak path(s), it is possible to completely drain a gross leaker leaving only a trace amount of red dye incapable of acting as an effective Kr85 getter during re-pressurization. 3. Not all devices with "leaking" red dye are non-hermetic. Ceramic devices/lids can contain worm holes capable of retaining red dye. Lid solder seals can have dead end solder voids that retain red dye.

ATTACHMENT 2 EXAMPLES OF DIFFICULT TO FIND RED DYE LEAKING DEVICES 1. Dead end voids. This is an example of a solder void capable of entrapping red dye without breaching hermeticity:

ATTACHMENT 2 Continued. 2. Ceramic worm hole voids. This is an example of a void in a ceramic lid which is capable of entrapping red dye without breaching hermeticity:

I ATTACHMENT 3 MODIFIED RADIOISOTOPE WET GROSS LEAK TEST PROCEDURE. Key for the proposed modification MIL STD 750 1, test method 1071, paragraph 4.2: New text to be added is identified in yellow highlighting. Example of text to be added. Text to be deleted is identified by red text, highlighted light blue with strike-out. Example of text to be deleted. 4.2 Procedure. The following four five steps shall be followed: Step 1: Step 2: The devices shall be immersed in the red dye penetrant solution and evacuated to a pressure of 100 mm of Hg or less for 10 minutes and then pressurized with air for 10 minutes minimum at 45 psia (310 kpa) minimum. The devices shall be removed from the red dye penetrant solution and placed in a fine-screen basket and flushed with acetone by applying a fine-spray of acetone to remove the surface film of the solution. It is recommended that the devices in the fine-screen basket be held over funnel, with the funnel inserted into a large Erlenmeyer flask, (thus minimizing the acetone vapors released into the room). Do not allow any acetone to contaminate the red dye penetrant solution. Immediately following the wash, the devices shall be emptied onto a white surface (such as paper towels), and examined carefully for evidence of red dye penetrant solution exiting from any leaking devices. Any devices with red dye penetrant solution leaking from them shall be rejected as gross leakers. All devices post visual inspection shall be placed on a white surface (lid down) and evacuated in ambient air to 26 in Hg for 10 minutes. Any gross leak devices will be easily visible via a red dye ring on the white surface and shall be rejected as gross leakers. Step 2 3: The devices shall then be placed in the radioisotope pressurization tank, (with all excess free volume displaced with aluminum filler blocks), and the tank evacuated to a pressure of 0.5 mm of Hg. The devices shall then be pressurized to a minimum of three atmospheres absolute pressure of 85 Kr/air mixture for 12 minutes minimum. The gas mixture shall then be transferred to storage until a pressure of 2.0 mm of Hg maximum exists in the tank. This transfer shall be completed in 2 minutes maximum. The tank shall then be filled with air, and the devices immediately removed from the tank and measured within 5 minutes after gas exposure, with a scintillation well crystal equipped counting station. It is recommended that batch sizes be kept small enough to allow all devices to be measured within 5 minutes. Any device indicating 500 counts per minute (cpm) or greater above the ambient background of the counting station shall be considered a gross leaker. If all of the devices cannot be measured within 5 minutes, they shall be retested starting at the beginning of step 2 3. Step 3 4: Failing devices may cross contaminate compliant devices with red dye penetrant solution. Devices which contain red dye penetrant solution may effervesce after being pressurized with 85 Kr and may lose the 85 Kr trapped within them. The devices shall be emptied onto a white surface (such as paper towels), and examined carefully for any red dye penetrant solution exiting from any leaking devices. Any devices with red dye penetrant solution leaking from them shall be rejected as gross leakers. Gross leak failures with a internal free cavity volume less than 0.05 cm 3 shall be visually inspected at 30X to confirm that the red dye penetrant solution is actually leaking from the device. Step 4 5: If any devices are rejected by steps 1 through 3 4, the procedure (starting with step 2 3) shall be repeated until no more gross leakers are found.