February 22, Dear Jerry Masiello:

Similar documents
510(k) SUMMARY K EIDOSMVED LLC OEC EDG Depth Gauge Page 1 of 2, 510(k) Summary

EasyOne Pro LAB Measurement Technology Background

EasyWarePro Message Numbers

EasyWarePro Message Numbers

What is ultrasonic plethysmography and how can we use it in airway disease?

PULMONARY FUNCTION TESTING CORE

Diffusing Capacity: 2017 ATS/ERS Standards for single-breath carbon uptake in the lung. Susan Blonshine RRT, RPFT, FAARC, AE-C

Body Box 5500 Series Pulmonary Function Testing Systems

Chapter 53: Clinical Center Single-Breath Carbon Monoxide Diffusing Capacity (DLCO) MOP 53.1 Introduction

Independent Health Facilities

Pulmonary Function I (modified by C. S. Tritt, April 10, 2006) Volumes and Capacities

Quality Control of Pulmonary Diagnostic Systems

A Pulmonary Function Product of Rare Distinction

3/24/2009 LAB D.HAMMOUDI.MD. 1. Trachea 2. Thoracic wall 3. Lungs 4. Primary bronchi 5. Diaphragm

HARD (Gas Dilution) HARDER (Plethysmography) EASIEST (MiniBox+)

Lung Volumes and Capacities

CARDIOVIT AT-104 ergospirometry

hypair compact+ Flowmeter Pulmonary Function Testing Station p A fast, accurate One-stop test center p Software guided clinical excellence

Institutional Review Board Responsibilities in making the Significant Risk and Non-significant Risk Device Determination

Lab 3. The Respiratory System (designed by Heather E. M. Liwanag with T.M. Williams)

ISO INTERNATIONAL STANDARD. Breathing system filters for anaesthetic and respiratory use Part 2: Non-filtration aspects

Date Effective 4/21/2008 Identification

The physiological functions of respiration and circulation. Mechanics. exercise 7. Respiratory Volumes. Objectives

spiro air dry rolling seal spirometer The gold-standard measurement p A fast, accurate One-stop test center p Software guided clinical excellence

DEPARTMENT OF HEALTH & HUMAN S E RVICES, 'mgr,':~~ MAY WARNING LETTE R

AUTOMATIC HOSE TEST UNIT, TYPE SPU

(12) United States Patent

Manual of Procedures for DLCO. ARIC Exam 5

Cardiopulmonary Physical Therapy. Haneul Lee, DSc, PT

Fashionable, don t you think?

MasterScreen PFT. Powered by SentrySuite

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

COMMERCIAL ITEM DESCRIPTION NITROGEN, TECHNICAL

bespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance

RM-80 respiration monitor

European Technical Standard Order (ETSO)

Public Assessment Report Scientific discussion. Lung test gas CO (He) AGA, 0.28%, inhalation gas, compressed (carbon monoxide, helium) SE/H/1154/01/MR

Oxygen Dialflow Meter. Instructions for Use

Chapter 37: Pulmonary Ventilation. Chad & Angela

Human Respiration Laboratory Experiment By

8. Pulmonary Function Testing

Cardiopulmonary Exercise Testing with Non-Invasive Measurement of Cardiac Output

HUD and HDE Topics. Humanitarian Use Device and. Humanitarian Use Device. Humanitarian Device Exemption


Via Federal Express Rockville, MD 20850

Respiratory System Lab

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Sleep apnoea breathing therapy Part 2: Masks and application accessories

#37 - Occupational Exposure to Silica; Final Rule

TV = Tidal volume (500ml) IRV = Inspiratory reserve volume (3,000 ml)

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Physiology of the Respiratory System

CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE

For more information about how to cite these materials visit

Policy Number: 42 Title: Investigational Devices Date of Last Revision: 06/12/2008; 07/22/2010; 05/29/2013; 05/01/2016; 10/16/2018

This document is a preview generated by EVS

Australian/New Zealand Standard

Biology 347 General Physiology Lab Basic Pulmonary Functions: Respirometry and Factors that Effect Respiration

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

HCT/P Deviations and Reporting

Introduction. Respiration. Chapter 10. Objectives. Objectives. The Respiratory System

Institutional Review Board - Restriction s Impo sed

Breeze Suite Quick Start Operator Manual. An Introduction to Pulmonary Function Testing

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Lesson 12 New Procedure PULMONARY FUNCTION I

CITREX H4 Mobile gas flow analyser. The ideal mobile device for flow and pressure analysing.»

SAFETY PRINCIPLES FOR PRESSURE REGULATORS FOR MEDICAL OXYGEN CYLINDERS

USER MANUAL. Supported products

Information Sheet Guidance For IRBs, Clinical Investigators, and Sponsors

Hazard Communication Program

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

Micro Dial-Flowmeter. Instructions for Use

Cornell Institute for. Biology Teachers. Respirometry Part I: Lung Volumes and Capacities. Lab issue/rev. date: 12/12/96. Title:

TABLE OF CONTENTS... 1

Australian/New Zealand Standard

LAB 7 HUMAN RESPIRATORY LAB. Complete the charts on pgs. 67 and 68 and read directions for using BIOPAC

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

AFRL-RH-WP-TR

Oxygen Dialflow Meter. Instructions for Use

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

ISO INTERNATIONAL STANDARD. Flow-metering devices for connection to terminal units of medical gas pipeline systems

Gas exchange measurement in module M- COVX

SpiroConnect Spirometer. Operating Instructions. Issue 1.1

POLICY FOR THE CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH (COSHH)

Respiratory protective devices

Lung Volumes and Capacities

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

Breathing of Humans and its Simulation

GGG-M-125/3A September 20, 1982 SUPERSEDING GGG-M-125/3 March 28, 1975 FEDERAL SPECIFICATION

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Respiration. Exercise 1A: Breathing in Resting Volunteers Aim: To measure breathing parameters in a resting individual.

PROTOCOL January 25, 2008

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

FDA > CDRH > CFR Title 21 Database Search. Registration Listing Adverse Events Advisory Committees. 21 CFR Part 56

ISO 5367 INTERNATIONAL STANDARD. Breathing tubes intended for use with anaesthetic apparatus and ventilators

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

21 CFR Part 56 - Institutional Review Boards

NIOSH Task Number 18388

Transcription:

DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 February 22, 2017 Ndd Medizintechnik Ag Jerry Masiello Operations Manager Ndd Medical Technologies Inc. 300 Brickstone Square, Suite 604 Andover, Massachusetts 01810 Re: K161534 Trade/Device Name: Easyone Pro Respiratory Analysis System Regulation Number: 21 CFR 868.1890 Regulation Name: Predictive Pulmonary-Function Value Calculator Regulatory Class: II Product Code: BTY Dated: January 13, 2017 Received: January 23, 2017 Dear Jerry Masiello: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Page 2 - Jerry Masiello Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical devicerelated adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/medicaldevices/resourcesforyou/industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/medicaldevices/safety/reportaproblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/medicaldevices/resourcesforyou/industry/default.htm. Enclosure Sincerely yours, Tina Kiang - S Tina Kiang, Ph.D. Acting Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control, and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Indications for Use Form Approved: OMB No. 0910-0120 Expiration Date: January 31, 2017 See PRA Statement below. 510(k) Number (if known) 161534 Device Name EasyOne Pro Respiratory Analysis System Indications for Use (Describe) EasyOne Pro/LAB is designed for conducting lung function measurements in general or specialist practices or in hospitals. EasyOne Pro/LAB can also be used in clinical settings in occupational medicine for performing lung function screenings or measurements. EasyOne Pro/LAB is used to conduct lung function measurements on adults and children starting at age 4, except measurements of diffusing capacity of the lung based on CO (DLCO), which can be performed on adults and children starting at age 6. Type of Use (Select one or both, as applicable) Prescription Use (Part 21 CFR 801 Subpart D) Over-The-Counter Use (21 CFR 801 Subpart C) PLEASE DO NOT WRITE BELOW THIS LINE CONTINUE ON A SEPARATE PAGE IF NEEDED. FOR FDA USE ONLY Concurrence of Center for Devices and Radiological Health (CDRH) (Signature) This section applies only to requirements of the Paperwork Reduction Act of 1995. *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number. FORM FDA 3881 (1/14) Page 1 of 1 PSC Publishing Services (301) 443-6740 EF

8 510(k) Summary In accordance with 21 CFR 807.92, the following information provides sufficient detail to understand the basis for a determination of substantial equivalence. Submitter Information Submitter name: United States contact person: ndd Medizintechnik AG Technoparkstrasse 1 8005 Zurich, Switzerland Mr. Jerry Masiello Operations Manager ndd Medical Technologies, Inc Phone: (877) 904.0090 x11 Fax: (978) 824.3853 Email: jmasiello@nddmed.com Type of Submission: Traditional 510(k) Date prepared: July 20, 2016 Device Name Proprietary name: EasyOne Pro Respiratory Analysis System Common name: Pulmonary function testing device Class Class II according to 21 CFR 868.1890 Classification name: Predictive pulmonary function value calculator Product code: BTY Regulation number: 868.1890 Predicate Device Primary Predicate: EasyOne Pro Respiratory Analysis System, model EasyOne Pro K091428 Secondary Predicate: EasyOne Pro Respiratory Analysis System, model EasyOne Pro LAB K120635 Device Description The EasyOne Pro Respiratory Analysis System consists of two different device models: EasyOne Pro and EasyOne Pro LAB. The EasyOne Pro Respiratory Analysis System devices are pulmonary function testing devices. Both EasyOne Pro Respiratory Analysis System device models provide Spirometry and Single Breath CO Diffusion (DLCO) tests including Lung Volume Parameters. The device model EasyOne Pro LAB additionally provides the Nitrogen Multiple Breath Washout (MBW) method. The Section 8: 510(k) Summary Page 1 of 7

EasyOne Pro Respiratory Analysis System devices meet the ATS recommendations for accuracy and precision for Spirometry, DLCO and MBW tests. The EasyOne Pro Respiratory Analysis System devices can be used as a stand alone system and can be connected to a network. The EasyOne Pro Respiratory Analysis System devices use the following sensors: An ultrasonic flow sensor to measure flow velocity, volume and molar mass of the gases that the patient inhales and exhales; a molar mass sensor which determines the helium content of the respired air for the DLCO test and the nitrogen concentration for the multiple breath washout (MBW) test; a CO sensor (EasyOne Pro) or a combined CO/CO 2 sensor (EasyOne Pro LAB) to determine CO and CO 2 content in breathing gas; a temperature and humidity sensor to collect environmental data. The EasyOne Pro Respiratory Analysis System devices are used in combination with test gases (DLCO gas for DLCO tests and O 2 for MBW tests). The EasyOne Pro Respiratory Analysis System devices are used in combination with the singlepatient use breathing tube ndd Spirette. For DLCO and MBW tests, the additional single patient use accessories, the ndd DLCO or FRC Barriettes, are used. The single patient use accessories prevent cross contamination between patients. The Spirette prevents the passage of microorganisms into the inside of the flow sensor; the Barriettes prevent the passage of microorganisms into gas supply tubing. Intended Use: EasyOne Pro/LAB is designed for conducting lung function measurements in general or specialist practices or in hospitals. EasyOne Pro/LAB can also be used in clinical settings in occupational medicine for performing lung function screenings or measurements. EasyOne Pro/LAB is used to conduct lung function measurements on adults and children starting at age 4, except measurements of diffusing capacity of the lung based on CO (DLCO), which can be performed on adults and children starting at age 6. Comparison of Technological Characteristics: The modified device models of the EasyOne Pro Respiratory Analysis System have the same technological characteristics with regards to Spirometry, DLCO and MBW testing as the predicate devices. Side by side comparison of technological characteristics Description Primary predicate device Secondary predicate device Subject device Device identification EasyOne Pro Respiratory Analysis System Model: EasyOne Pro K091428 EasyOne Pro Respiratory Analysis System Model: EasyOne Pro LAB K120635 EasyOne Pro Respiratory Analysis System Models: EasyOne Pro EasyOne Pro LAB K161534 Product code BTY BTY BTY Section 8: 510(k) Summary Page 2 of 7

Description Primary predicate device Secondary predicate device Subject device Intended Use (incl. target population) System for pulmonary function testing on adults and children (over the age of 4 for spirometry lung function measurements and over the age of 6 for DLCO testing). Target users The EasyOne Pro Respiratory Analysis System is used by physicians, respiratory therapists or nurses in general or specialist practices or in hospitals. The EasyOne Pro Respiratory Analysis System can also be used in clinical settings in occupational medicine for performing lung function screenings or measurements in occupational medicine. User interface Resistive touch screen for data entry and display Capacitive touch screen for data entry and display Patient interface EasyOne Pro: Disposable breathing tube Spirette Disposable barrier shield DLCO Barriette EasyOne Pro LAB: All identical In addition: Disposable barrier shield FRC Barriette Components EasyOne Pro : Main Unit (embedded computer, touch screen and monitor) Handheld flow sensor Breathing valve assembly (for DLCO and FRC tests) DLCO gas mix supply 100 240 VAC, 50/60 Hz power supply EasyOne Pro LAB: All identical In addition: 100% O2 gas supply Operating system Microsoft Windows XP Embedded Microsoft Access database Microsoft Windows 8 Embedded SQLite/Microsoft SQL server database Section 8: 510(k) Summary Page 3 of 7

Description Physical dimensions Pulmonary Function Testing Principle of operation Reported Spirometry parameters Reported Lung Volume parameters Reported DLCO parameters Test gas requirements for DLCO test Primary predicate device 270 mm x 335 mm x 270 mm (h x w x d) EasyOne Pro : Spirometry tests: FVC, FVL, SVC, MVV, Prepost Bronchodilator Single Breath CO Diffusion (DLCO) test including Lung Volume EasyOne Pro: All test types measurement of patient air flow via ultrasonic transit time flow sensor. DLCO test determination of in and exhaled gas concentrations: CO gas concentration measured by infrared absorption with CO sensor. Helium tracer gas concentration measured by molar mass sensor. FVC, FEV0.5, FEV1, FEV3, FEV6, FEV1/FVC, FEV3/FVC, FEV1/FEV6, FEF25%, FEF50%, FEF75%, FEF25 75%, FEF75 85%, PEF, FIVC, FIV0.5, FIF50%, PIF, FET, Vext, MVV, MTV, RR, AT, VC, ERV, IRV, TV EasyOne Pro: DLCO test: FRC, TLC, RV, RV/TLC, VT, f DLCO, TLCO, DLadj, DLCO/VA, DLCO/VAadj, VA, VCin, BHT Medical grade gas mix CO: 0.3 % Helium: 10 % Oxygen: 18 % 25 % Nitrogen: balance Secondary predicate device EasyOne Pro LAB: All identical In addition: Nitrogen Multiple Breath Washout (MBW) test EasyOne Pro LAB: All identical In addition: MBW test determination of in and exhaled gas concentrations: Nitrogen tracer gas concentration determined by a combination of molar mass measurement (molar mass sensor) and CO 2 measurement (CO/CO2 sensor). EasyOne Pro LAB: All identical In addition MBW test: FRC, TLC, RV, RV/TLC, LCI, VT, f Subject device Section 8: 510(k) Summary Page 4 of 7

Description Test gas requirements for MBW test Flow sensor specification Flow range Volume accuracy Flow accuracy Flow resistance Molar mass sensor specification Type Range Resolution Accuracy CO Sensor specification Type Range Resolution Accuracy CO2 Sensor specification Type Range Resolution Accuracy Tracer Gas Analysis for DLCO Tracer gas Type Range Resolution Accuracy Tracer Gas Analysis for MBW Tracer gas Type Range Resolution Accuracy Primary predicate device (not applicable for EasyOne Pro) ±16 L/s Greater of ±2 % or 0.050 L Greater of ±2 % or 0.020 L/s <1.5 cm H 2 O/L/s (at 12 L/s) Ultrasonic transit time 9 50 g/mol 0.02 g/mol ±0.01 g/mol Infrared absorption 0 0.35 % 0.0001 % ±0.001 % (not applicable for EasyOne Pro) Helium Molar mass sensor 0 50% He 0.01% He ±0.05% He (not applicable for EasyOne Pro) Secondary predicate device Oxygen 100 % Infrared absorption 0 7 % 0.01 % ±0.1 % Nitrogen Molar mass sensor 0 100 % N 2 0.1 % N 2 ±0.2 % N 2 Subject device 0.3 cm H 2 O/L/s (at 12 L/s) 0.005 g/mol 0 15% 0.005% ±0.05% Section 8: 510(k) Summary Page 5 of 7

The same single patient use accessories Spirette, DLCO Barriette and FRC Barriette are used with the modified devices than with the predicate devices. The same materials in the patient gas path are used with the modified devices and the predicate devices. Differences between the modified and the predicate EasyOne Pro Respiratory Analysis System devices: The modified devices differ in appearance from the predicate devices in that they have a different color scheme of the device housing, a different on/off button and a different design of the software user interface. A capacitive touch screen is used for the modified devices in comparison to the resistive touch screen used for the predicate devices. A different PC board but providing the same functionalities is used for the modified devices. In the modified devices, a metal box around the CO or CO/CO 2 sensor provides improved EMC protection. A power supply of higher efficiency but identical environmental specifications is used for the modified devices. An internal USB stick instead of a CF card for internal back up data storage is used for the modified devices. DISS gas hose connectors are used in the modified devices instead of the Quick Connectors used in the predicate devices. The board used for data acquisition is modified compared to the predicate device, but keeping the same functions. The outer geometry of the MMss sensor is modified compared to the predicate devices, but without modifying the operating principle and functionality of the sensor. For the modified EasyOne Pro LAB device model, a modified combined CO/CO 2 sensor is used; the modified combined CO/CO 2 sensor contains an additional reference path but has the same performance specifications as the combined CO/CO 2 sensor used in the predicate device. The modified devices use Windows 8 instead of Windows XP embedded operating system and SQLite/Microsoft SQL server as database technology instead of Microsoft Access. For the modified devices, some of the labelled specifications were updated to reflect the technical capabilities. No changes were made to the components the specifications relate to. Design verification and validation demonstrated that the performance of the modified EasyOne Pro Respiratory Analysis System is the same as for the predicate EasyOne Pro Respiratory Analysis System. The modified as well as the predicate EasyOne Pro Respiratory Analysis System meet the ATS recommendations for accuracy and precision for spirometry, DLCO and MBW tests. The modified EasyOne Pro Respiratory Analysis System is therefore substantially equivalent to the predicate EasyOne Pro Respiratory Analysis System. Summary of Testing: Simulated Spirometry, DLCO and MBW testing, as well as testing with humans, confirmed that the modified EasyOne Pro Respiratory Analysis System devices meet the recommendations for accuracy and precision for Spirometry, DLCO and MBW tests of the American Thoracic Society (ATS). The modified devices were tested to demonstrate conformance with the requirements for medical electrical equipment basic safety and essential performance of standards IEC 60601 1 and IEC 60601 1 2. Section 8: 510(k) Summary Page 6 of 7

Software verification and validation in accordance with IEC 62304 confirmed that the modified EasyOne Pro Respiratory Analysis System meets the specified criteria. Biocompatibility was evaluated in accordance with ISO 10993 1: Biological Evaluation of Medical Devices Part 1: Evalua on and Tes ng within a Risk Management Process. Conclusion: Based on the above, ndd Medical Technologies concluded that the modified EasyOne Pro Respiratory Analysis System is substantially equivalent to the legally marketed predicate devices and is as safe and as effective for their intended use. Section 8: 510(k) Summary Page 7 of 7