Evaluation of the fraction of Unit-3 vent gas that flowed into Unit-4 reactor building

Similar documents
Leaks from Unit-3 PCV and steam release in a large amount

Analysis of the hydrogen explosion at the Unit-1 Reactor Building

Verification and validation of computer codes Exercise

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

TEPCO s Safety Assurance Philosophy on Nuclear Power Generation Plants

ON TRANSIENTS IN PUMA

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Best Practices for Installation of Gaseous Sample Pumps

PURE SUBSTANCE. Nitrogen and gaseous air are pure substances.

DETAILS OF THE ACCIDENT PROGRESSION IN 1F1

Transient Analyses In Relief Systems

Tutorial. BOSfluids. Relief valve

HYDROGEN RISK ANALYSIS FOR A GENERIC NUCLEAR CONTAINMENT VENTILATION SYSTEM

Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios

Simulation of Experiment on Aerosol Behaviour at Severe Accident Conditions in the LACE Experimental Facility with the ASTEC CPA Code

SAFETY DEMONSTRATION TESTS ON HTR-10

CONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS

IEM on Severe Accident Management in the light of the accident at the Fukushima Daïchi NPP

HOW TO MANAGE VAPORIZATION IN AN ANALYTICAL SYSTEM By Dean Slejko and Tony Waters

Instrumentation systems of BWR

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Tokyo Electric Power Company Holdings, Inc. November 30, 2017

IAEA Training in Level 2 PSA MODULE 8: Coupling Source Terms to Probabilistic Event Analysis (CET end-state binning)

Effects of Delayed RCP Trip during SBLOCA in PWR

SENSITIVITY ANALYSIS OF THE FIRST CIRCUIT OF COLD CHANNEL PIPELINE RUPTURE SIZE FOR WWER 440/270 REACTOR

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

I.CHEM.E. SYMPOSIUM SERIES NO. 97 BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES

HTR Systems and Components

ASVAD THE SIMPLE ANSWER TO A SERIOUS PROBLEM. Automatic Safety Valve for Accumulator Depressurization. (p.p.)

The Discussion of this exercise covers the following points:

Control of Nuclear Gloveboxes and Enclosures Using the No- Moving-Part Vortex Amplifier (VXA)

ICONE ASSESSMENT OF THE TRACE REACTOR ANALYSIS CODE AGAINST SELECTED PANDA TRANSIENT DATA

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Safety. April 2018 Supersedes all previous publications 2018 Chevron Phillips Chemical Company LP

Injector Dynamics Assumptions and their Impact on Predicting Cavitation and Performance

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

A Hare-Lynx Simulation Model

Modelling of the Separated Geothermal Water Flow between Te Mihi flash plants

Hydraulic and Economic Analysis of Real Time Control

ASSIGNMENT 2 CHE 3473

OIL AND GAS INDUSTRY

Autodesk Moldflow Communicator Process settings

ASSIGNMENT 2 CHE 3473

Steam penetration in steam sterilization processes

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

Characterizers for control loops

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Flow in a shock tube

1.2 Example 1: A simple hydraulic system

Chapter 3 Atmospheric Thermodynamics

XA TEPSS RELATED PANDA TESTS (ESBWR)

Classical Event Tree Analysis and Dynamic Event Tree Analysis for High Pressure Core Melt Accidents in a German PWR

Chapter 13 Gases, Vapors, Liquids, and Solids

The new PTB standard for dynamic vacuum pressures

Nuclear safety Lecture 4. The accident of the TMI-2 (1979)

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

Dimensioning of Safety Valves Auditorium Tecnimont

Air Requirements 1 INTRODUCTION

Passive BWR Integral LOCA Testing at the Karlstein Test Facility INKA

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

EXPERIMENTAL SUPPORT OF THE BLEED AND FEED ACCIDENT MANAGEMENT MEASURES FOR VVER-440/213 TYPE REACTORS

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c

End of Chapter Exercises

Steam generator tube rupture analysis using dynamic simulation

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS. A high-capacity EBA system [CSVS] [main purge]

New Findings for the Application of Systems for Explosion- Isolation with Explosion Venting

Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers TABLE OF CONTENTS

delft hydraulics Taco air and dirt separator 4903AD-4 Taco Inc., Cranston RI Prepared for: Summary: Efficiency of air separation I.

FAILURE AND HAZARD ANALYSIS OF THE NPDGAMMA LH2 TARGET SYSTEM

DISTILLATION PRESSURE CONTROL TROUBLESHOOTING THE HIDDEN PITTFALLS OF OVERDESIGN

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOUR IN A MODERN TRAFFIC TUNNEL IN CASE OF FIRE INCIDENT

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Safety Aspects and Design of the Vent Isolation Chamber. Prepared: W.M. Snow Checked: H. Nann Approved: W. M. Snow

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

Experiment 8: Minor Losses

Under pressure pushing down

Figure Vapor-liquid equilibrium for a binary mixture. The dashed lines show the equilibrium compositions.

CHARACTERISTICS OF LEAK DETECTION BASED ON DIFERENTIAL PRESSURE MEASUREMENT

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

Improvement of the Volumetric and Isentropic Efficiency Due to Modifications of the Suction Chamber

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

You should be able to: Describe Equipment Barometer Manometer. 5.1 Pressure Read and outline 5.1 Define Barometer

ASHRAE made significant changes in 2001 to the calculations. Fundamentals of Safety Relief Systems

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Application Worksheet

Pressure reducing valves Index

Outcomes: Operationally define vapour pressure

Applied Fluid Mechanics

Unit 2 Primary Containment Vessel Internal Investigation

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

CTB3365x Introduction to Water Treatment

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

The Nitrogen Threat. The simple answer to a serious problem. 1. Why nitrogen is a risky threat to our reactors? 2. Current strategies to deal with it.

Absorption - The process of contacting a vapor and gas stream with an absorbing liquid to remove specific materials from the gas stream.

Khosla's theory. After studying a lot of dam failure constructed based on Bligh s theory, Khosla came out with the following;

Thermodynamics ERT 206 Properties of Pure Substance HANNA ILYANI ZULHAIMI

Transcription:

Attachment 3-1 Evaluation of the fraction of Unit-3 vent gas that flowed into Unit-4 reactor building 1. Introduction The hydrogen explosion, which occurred on March 15, 211, at the Unit-4 reactor building (R/B) of Fukushima Daiichi Nuclear Power Station, is believed to have been caused by part of the vent gas of Unit-3, released when the Unit-3 containment vessel (PCV) had been vented. The vent gas included hydrogen and it flowed in reverse to the Unit-4 R/B via the Unit-4 standby gas treatment system (SGTS). In the evaluations to date [1][2][3], about 25 to 29% of the vent gas was considered to have flowed to the Unit-4 R/B, depending on the conditions that were assumed. However, some drawbacks were present in those studies, for example: dependence of pressure loss coefficient of friction on flow velocity was not taken into account [1][2]; and the whole piping configuration was not incorporated in the modelling [3]. It should be noted that, the amount of hydrogen which flowed into the Unit-4 R/B can be roughly estimated as the amount of hydrogen in the Unit-3 PCV calculated by the accident analysis code multiplied by the fraction above, but there are large uncertainties in the amount of hydrogen calculated by current accident analysis codes [4]. The fraction of vent gas, which had flowed to the Unit-4 R/B, was evaluated by a thermal-hydraulic code to deepen the understanding of mechanisms which had caused the hydrogen explosion at Unit-4. This code is capable of modeling the whole configuration of gas flow paths including piping based on the design data, and of evaluating the impact of pressure loss along the line depending on the flow gas velocities. Initial conditions such as the amount of hydrogen gas in the Unit-3 PCV at the time of venting were derived from the plant parameters measured at that time, not from the results of the accident analysis code. 2. Vent gas flow paths Figure 1 illustrates the assumed vent gas flow paths from the Unit-3 PCV to the Unit- 4 R/B. The following three reasons can be considered for the Unit-3 vent gas flows to Unit-4. 1 The vent line had been modified from its form at the time of plant construction as an accident management (AM) measure; that is, by using most of the Attachment 3-1-1

existing SGTS (connected to the Unit-4 ventilation ducts having openings in the building), it was able to serve as an AM measure. 2 The Unit-3 and Unit-4 SGTS lines were joined together before reaching their common stack. 3 All valves in the Unit-4 SGTS line were automatically opened at the time of the station black-out (fail-open design). It should be noted that no dampers were in place at the exit of the Unit-4 SGTS filter trains to prevent reverse flows. Dampers are not powerful enough to completely prevent reverse flows, but if they had been in place, they could have prevented significant reverse flows into the building. Unit Unit 3 R/B R/B 2 2 nd nd floor floor MO Vent MO valve (15% (15% open) open) Unit3 S/C Vent gas flow to stack Stack Stack (12m) (12m) Unit4 Pipe type AR/B R/B Pipe type B Pipe type C Vent gas flow to unit 4 SGTS SGTS train train & 2 nd nd floor floor Ducts Ducts B1 floor Exhaust Exhaust fan fan Side view Bend (9 deg) Bend (135 deg) Stack 1 1 st st floor floor Ground Ground level level to Unit 4 Unit3 Unit3 S/C S/C Vent gas flow from Unit 3 containment B1 B1 floor floor Pipe Pipe Atmospheric type type A Control system piping Bend Bend (9 (9 deg) deg) Pipe Pipe SGTS type type piping B Exhaust stack Bend Bend (135 (135 deg) deg) Pipe Pipe type type C Side Side view view Branch part to Stack stack Stack from Unit 3 Top Top view view Figure 1 Vent gas flow paths from Unit-3 PCV to Unit-4 R/B 3. Analysis of the vent gas fraction that flowed into Unit-4 R/B The amount of hydrogen and other conditions in Unit-3 PCV when the PCV had been vented were estimated based on plant parameters measured at that time. The results were used as initial conditions to analyze the fraction of vent gas which had flowed to Unit-4. 3.1. Estimation, based on measured values, of the Unit-3 in-containment conditions at the time of venting Figure 2 presents plant parameters measured before and after the Unit-3 PCV venting. Besides the plant data in Figure 2, Unit-3 plant data readings recorded by shift operators at the time of the earthquake are available. Although they are slightly different in Attachment 3-1-2

Pressure [MPa(abs)] Fuel range water level indicator leading (TAF-base)[mm] numerical values from what is shown in Figure 2, the data in Figure 2 were used in the current study. Pressures are expressed in absolute values throughout this attachment. The drywell (D/W) pressure was 47 kpa[abs] at 8:55 on March 13, 211. It increased to 637 kpa[abs] at 9:1 and decreased thereafter to 63 kpa[abs] at 9:15. The PCV is considered to have been vented before 9:15. In the current study, it was assumed that the PCV venting had started at 9:1, when the measured value had been recorded. The PCV conditions (pressures, temperatures, gas compositions) at 9:1 were estimated in the following steps. a. Pressures were estimated from the measured values. b. Gas temperatures were estimated from the measured values. c. Gas partial pressures were estimated based on estimated pressures and temperatures. 1. RPV pressure (A) (left axis) S/C pressure (left axis) Fuel range water level indicator (B) (right axis) D/W pressure (left axis) Fuel range water level indicator (A) (right axis) 5.9 4.8 3.7 2.6 1.5.4-1.3-2.2-3.1-4. 8:3 8:4 8:5 9: 9:1 9:2 9:3 9:4 9:5 1: 1:1 1:2 1:3 1:4 1:5 Figure 2 Plant parameters measured before and after PCV venting -5 11: The gaseous phase in the PCV was assumed to have contained, at the outset of PCV venting, nitrogen gas, which had filled the PCV during normal operation, steam and hydrogen, both of which had been produced in the process of the accident. Table 1 shows the in-pcv conditions at the outset of the assumed PCV venting. The grounds for the estimation are elaborated later for the D/W and suppression chamber (S/C). Attachment 3-1-3

Table 1 In-PCV conditions assumed at the outset of PCV venting In D/W Pressure 637 kpa[abs] Gas temperature 135 deg C Gas partial pressures (against total pressure) Nitrogen: about 35% Steam: about 5% Hydrogen: about 15% In S/C Pressure 637 kpa[abs] Gas temperature 13 deg C Gas partial pressures (against total pressure) Nitrogen: % Steam: % to about 42% Hydrogen: about 58% to 1% (1) Grounds for estimation of in-d/w conditions at the outset of PCV venting a. Estimation of pressure The D/W pressure measured as 637 kpa[abs] at 9:1 was used as it was. There is room to argue on the reliability of absolute numerical values obtained by the D/W pressure indicator (Attachment 3-7), but the measured values were taken in the current study, because the overall impacts to reliability of the study outcome were considered small. b. Estimation of gas temperature The D/W gas temperature was estimated based on the fuel range water level indicator readings. Figure 2 shows the fuel range water level indicator readings remained roughly constant until about 1: after the venting had started and decreased gradually thereafter. The decrease of fuel range water level indicator readings after about 1: is considered to have been due to decompression boiling and the ensuing level decrease in the variable leg of fuel range water level indicator piping (see Attachment 3-9). Consequently, the water temperature in the variable leg at about 1: was estimated to be the saturation temperature 135 deg C at the reactor pressure 31 kpa[abs] measured at this timing. As no thermal insulators were installed on the water level indicator piping, the water temperature in the variable leg was assumed to be in equilibrium with the D/W gas temperature, hence 135 deg C, the same as the D/W gas temperature. Further assuming no big temperature changes in the D/W gas temperature during PCV venting, the D/W gas temperature was also assumed to be 135 deg C when the venting had started. Attachment 3-1-4

c. Estimation of gas partial pressures The partial pressure of nitrogen was assumed to be about 223 kpa (about 35% of total pressure), as all the nitrogen in the S/C was assumed to have been transferred to the D/W due to the safety relief valve (SRV) operations before the venting and activation of the automatic depressurization system (ADS) (see Attachment 3-5). The partial pressure of steam was estimated to be about 318 kpa (about 5% of total pressure) as the saturated steam pressure for the D/W temperature estimated above of 135 deg C. The partial pressure of hydrogen was estimated to be about 96 kpa (about 15% of total pressure) by subtracting the above partial pressures of nitrogen and steam from the D/W pressure of 637 kpa[abs]. (2) Grounds for estimation of in-s/c conditions at the outset of PCV venting a. Estimation of pressure The S/C pressure was estimated as 637 kpa[abs], by assuming a situation that the S/C and D/W pressures had been in equilibrium as the result of vacuum breaker valves having been activated when gases had flowed into the S/C from the reactor by operations of the SRVs and ADS before the venting. b. Estimation of gas temperature The S/C gas temperature was estimated from the measured PCV pressures. The PCV pressures began to decrease from 9:1 due to venting but increased for a while at around 1:. It is considered at this timing that part of the molten debris was relocated to the lower plenum and that steam and hydrogen were being produced (see Attachments 3-3, 3-4, and 3-9). These gases are considered to have raised the PCV pressures temporarily by being transferred to the PCV. Although this temporary pressure increase delayed the PCV pressure decrease, it decreased monotonously thereafter and from 1:4 the D/W pressure remained constant at 27 kpa[abs] and the S/C pressure at 22 kpa[abs], respectively. Two possibilities are considered for the D/W and S/C pressures to have remained constant: decompression boiling began in the S/C pool; or the vent line was closed. If decompression boiling had begun in the S/C pool, a large amount of steam should have been produced and therefore the PCV pressure decrease should have been slowed down. But no such trend could be noticed until 1:4 in the measured values of PCV pressures except the above-mentioned temporary increase. Therefore, the S/C pool water temperature at 1:4 can be considered to have been at or below the saturation temperature for the PCV pressure at that timing. Attachment 3-1-5

In the meantime, the large air-operated (AO (large)) valve on the vent line is confirmed to have been closed as of 11:17 due to loss of driving air pressure [1]. The AO (large) valve could have been closed as of 1:4. If that is the case, the S/C pressure could have been constant irrespective of the S/C pool water temperature. It is not possible, therefore, to estimate from the measured data to what extent the S/C pool water temperature was lower than the saturation temperature as of 1:4. In the current study, the S/C gas temperature was set at a higher value by assuming the S/C pool water temperatures at 1:4 as the saturation temperature for the D/W pressure (27 kpa[abs]), i.e. 13 deg C. The S/C gas temperature was also assumed to be 13 deg C. Furthermore, the S/C gas temperature when the vent had started was also assumed to be 13 deg C, by considering that no big changes would have occurred during PCV venting. c. Estimation of gas partial pressures The S/C pressures increased from 445 kpa[abs] to 59 kpa[abs] between 8:55 and 9:1, as can be seen in Figure 2. As of 8:55, the reactor water level is estimated to have dropped to a level near the bottom of active fuel (BAF) (see Attachment 3-9). The S/C pressure increase is considered to have been caused by the hydrogen inflows from the RPV to S/C upon ADS activation during production of a large amount of hydrogen in the core region, where the temperatures had been elevated due to reactor water decrease. If this is the case, the S/C could have been in a gas-liquid non-equilibrium state (steam partial pressure < saturation vapor pressure), as the result of steam removal from the S/C to D/W by the hydrogen inflows to the S/C. D/W Hydrogen Steam T-quencher S/C Figure 3 Steam behavior in the S/C when hydrogen gas flowed in Attachment 3-1-6

The following two extreme cases were assumed, as it is unknown to what extent the steam pressure was below the saturation vapor pressure. Case A: S/C in a gas-liquid equilibrium state (steam pressure = saturation vapor pressure) The nitrogen partial pressure was set at by assuming that all of the nitrogen gas had moved to the D/W. The steam partial pressure was set at about 27 kpa (about 42% of total pressure) by assuming that the saturation vapor pressure at the S/C gas temperature had remained in the S/C. The hydrogen partial pressure was set at about 367 kpa (about 58% of total) by subtracting the steam partial pressure from the total. Case B: S/C in a gas-liquid non-equilibrium state (steam pressure = ) The nitrogen partial pressure was set at by assuming that all of the nitrogen gas had moved to the D/W. The steam partial pressure was also set at by assuming that all of the steam had been pushed out of the S/C to the D/W by hydrogen. As a result, the gaseous phase in the S/C became filled by hydrogen (637 kpa). It is considered that additional steam and hydrogen were produced at about 1: when part of the molten debris was relocated into the lower plenum, and caused the PCV pressure increase, as being pointed out in (2) b. Estimation of gas temperatures. This additional production of steam and hydrogen is not taken into account in the analysis in Section 3.2. But it is believed that this does not influence the conclusions of the current study because the gaseous volume fractions in the PCV have little influence on the vent gas fraction which flows to Unit-4 R/B. 3.2. Analysis of vent gas flows to Unit-4 R/B The thermal-hydraulic analysis code GOTHIC was used to evaluate the fraction of Unit-3 vent gases and the amount of hydrogen gas flowing into Unit-4 R/B, with the influence of actual piping lengths, piping diameters and bending configuration being considered. (1) Configuration for analysis The Unit-3 PCV, vent lines of Unit-3 and Unit-4, and the stack were configured in the modelling for analysis. Figure 4 illustrates the configuration for GOTHIC analysis. Attachment 3-1-7

Yellow: Regions Green: Junctions Red: Structures Blue: Pressure boundary Stack outlet Unit-3 D/W Environment Unit-3 SGTS line (I.D. 333mm) Units-3/4 common stack inner piping (I.D. 381mm) Unit-4 SGTS line (I.D. 333mm) Vent line Unit-3 S/C MO valve Bifurcation Unit4 R/B (until reaching SGTS exhaust) Figure 4 Configuration for GOTHIC analysis Since check valves were installed at the outlet of the SGTS filter trains at Unit-3, this would have limited the reverse flow of vent gases back to Unit-3. Therefore, the vent gas reverse flow paths to the Unit-3 R/B were not included in the analysis. Concerning vent gas flow paths to Unit-4 R/B, the SGTS piping was connected to the ventilation ducts in the building via the SGTS filter trains in between. In the analysis, the configuration up to the SGTS filter train exit (near the SGTS exhauster) was incorporated in the modelling. The PCV volume, diameters and lengths of venting lines and stack were taken from the design data. Venting line configurations were integrated in the analysis into simplified horizontal lines and vertical lines, although they were actually more complicated. The simplification facilitated modelling and saved computation time. Fractions of vent gas flows to the stack and Unit-4 R/B depend on the pressure loses in the piping downstream from the bifurcation. Pressure losses in the piping have two components: frictional pressure losses due to friction between vent gases and piping inner walls; and localized pressure losses at pipe bends, and at pipe enlargement or Attachment 3-1-8

reduction sections. To calculate the frictional pressure losses accurately, including velocity dependency, piping diameters and lengths were modelled from the design data. The localized pressure losses at pipe bends and pipe enlargement or reduction sections were calculated by simulating the paths in the form of respective pressure loss coefficients, while the localized pressure losses downstream from the Unit-4 SGTS filter train exit (SGTS filter train, ventilation ducts, etc.) were calculated by setting a localized pressure loss coefficient before reaching the Unit-4 R/B pressure boundary (near the SGTS exhauster). The vent valve (MO valve) aperture was set at 15% based on the operational records [1]. As the pressure boundary conditions, atmospheric pressure was set on the Unit-4 R/B side, and the pressure loss due to the stack height was taken into account for the stack exit side. On the other hand, heat releases to the environment were also taken into account by modelling the stack as heat structures in calculating the heat transfer in order to evaluate the impacts of condensed steam in the vent gases on the flow. (2) Conditions for analysis The time period of 9:1 to 11: on March 13 was chosen for analysis, this being from the time when the first venting had started at Unit-3 to the time when the PCV pressures had decreased and stabilized. The AO (large) valve on the vent line was assumed to have been open during this period. Table 2 summarizes the key conditions for analysis. The initial conditions (pressures, air temperatures and gas compositions) of D/W and S/C were set from the estimations in Section 3.1. Two cases were analyzed: the case of small hydrogen inventory in the S/C at the time of vent initiation (Case A); and the case of large hydrogen inventory (Case B). The S/C pool water level at the time of vent initiation is unknown, and was assumed in the analysis to have been at the S/C mid-height (roughly at the normal level). The S/C pool water level determines the free volume in the S/C, which, when combined with the partial gas pressures estimated in Section 3.1, determines the gas inventory in the PCV at the time of venting. The impacts of the assumed S/C pool water level on the results of analysis are discussed later in (3) g. Hydrogen inventory having flowed into Unit-4 R/B. Attachment 3-1-9

Table 2 Conditions for analysis Item Conditions for analysis Remarks Period 9:1 to 11: on March 13, 211 From when the PCV analyzed (First venting at Unit-3) pressure started to decrease to when it was roughly stabilized D/W initial 637 kpa[abs]; 135 deg C See Section 3.1 (1) conditions N 2 35%; Steam 5%; H 2 15% (Hydrogen inventory about 24 kg) S/C initial conditions Initial conditions at other locations 637 kpa[abs]; 13 deg C; Water about 3 See Section 3.1 (2) m 3 Case A: S/C in gas-liquid equilibrium N 2 %; Steam 42%; H 2 58% (Hydrogen inventory: about 67 kg in S/C, about 91 kg in PCV) Case B: S/C in gas-liquid non-equilibrium N 2 %; Steam %; H 2 1% (Hydrogen inventory: about 117 kg in S/C, about 141 kg in PCV) Atmospheric pressure; 1 deg C; Pressure loss due to stack Air 1% height taken into consideration at the stack exit pressure boundary (3) Results of analysis a. Pressures in PCV and vent lines Figure 5 shows the measured PCV pressures, and the PCV and vent line pressures obtained from the analysis. In both Cases A and B, the PCV pressure decreasing trend and the lowest limit during the period are reproduced. Vent line pressures downstream from the MO valve (a narrowed section on the flow path) dropped very quickly and as a result the pressure at the SGTS line junction is about the atmospheric pressure (roughly 12 kpa or below). Attachment 3-1-1

Pressure [kpa] Pressure [kpa] 8 7 6 5 D/W (measured) S/C (measured) D/W pressure (calculated) S/C pressure (calculated) MO valve downstream (calculated) SGTS pipe joint part (calculated) 8 7 6 5 D/W (measured) S/C (measured) D/W pressure (calculated) S/C pressure (calculated) MO valve downstream (calculated) SGTS pipe joint part (calculated) 4 4 3 3 2 2 1 1 9: 9:3 1: 1:3 11: 9: 9:3 1: 1:3 11: Case A Figure 5 PCV pressures and vent line pressures Case B b. Vent gas flow rates Figure 6 shows the vent gas flow rates at selected positions on the vent line. The fraction of vent gases which flowed into the Unit-4 R/B are discussed later in (3) f. Fraction of vent gas having flowed into Unit-4 R/B. It should be noted that the flow rate behavior just after the onset of venting is different in Case A and in Case B. In Case A, steam is contained in the S/C at the time of vent initiation, while in Case B the S/C is filled with lower density hydrogen and consequently flow rates just after the onset of venting are lower than in Case A. It is considered that the steam fraction increases in the S/C, thereafter, with hydrogen being released and the gas compositions approach the same value (see Figure 8) in both Cases A and B, irrespective of different initial conditions, and with the increasing density of the vent gases, the flow rates in Case B eventually approach the flow rates in Case A. Attachment 3-1-11

Gas volume fraction [-] Gas volume fraction [-] Flow rate [kg/s] Flow rate [kg/s] 1 1 9 Total vent gas flow 9 Total vent gas flow 8 Stack outlet gas flow 8 Stack outlet gas flow 7 Inflow to unit 4 R/B 7 Inflow to unit 4 R/B 6 6 5 5 4 4 3 3 2 2 1 1 9: 9:3 1: 1:3 11: 9: 9:3 1: 1:3 11: Case A Figure 6 Flow rates in vent lines Case B c. Gas volumetric fractions in D/W Figure 7 shows gas volumetric fraction changes in the D/W. No big changes are noticeable in the fraction of hydrogen in the D/W during the venting in either case. Since the D/W pressure is itself decreasing, the hydrogen is being released in the vent gas via the S/C in proportion to the pressure decrease. 1 1.9 Nitrogen fraction in D/W.9 Nitrogen fraction in D/W.8 Steam fraction in D/W.8 Steam fraction in D/W.7 Hydrogen fraction in D/W.7 Hydrogen fraction in D/W.6.6.5.5.4.4.3.3.2.2.1.1 9: 9:3 1: 1:3 11: 9: 9:3 1: 1:3 11: Case A Figure 7 Gas volumetric fraction changes in D/W Case B d. Gas volumetric fractions in S/C Figure 8 shows gas volumetric fraction changes in the S/C. During the venting, the D/W gases are vented via the S/C, and therefore the nitrogen volumetric fraction in the S/C increases temporarily at the beginning but is released together with hydrogen as the pressure decreases. The steam fraction increases with time because the steam Attachment 3-1-12

Gas volume fraction [-] Gas volume fraction [-] continues being produced from the S/C pool to keep the saturation vapor pressure at the S/C temperature. In both Cases A and B, hydrogen is almost completely released by about 11:. In the current study, the AO (large) valve was assumed to have been open. But the figure shows that hydrogen in the S/C was almost completely discharged by about 1:4 even if the AO (large) value had been closed at that time. 1. 1.9.9.8.8.7.7.6.5.4 Nitrogen fraction in S/C Steam fraction in S/C Hydrogen fraction in S/C.6.5.4 Nitrogen fraction in S/C Steam fraction in S/C Hydrogen fraction in S/C.3.3.2.2.1.1. 9: 9:3 1: 1:3 11: 9: 9:3 1: 1:3 11: Case A Figure 8 Gas volumetric fraction changes in S/C Case B e. Gas volumetric fraction changes in the stack Figure 9 shows gas volumetric fractions in the stack. Immediately after the vent initiation, the vent gases in the stack were condensed by transferring heat to the stack structures, but once the structures were warmed enough, heat transfer was minimized, and no more significant condensations occurred. In both cases, the gas volumetric fractions were constantly above 99% during the venting. The influence of condensation of vent gases on the vent gas flows is negligible. Attachment 3-1-13

Void fraction [-] Void fraction [-] 1.1 1.5 Void fraction in stack (height -24m) Void fraction in stack (height 24-48m) Void fraction in stack (height 48-72m) Void fraction in stack (height72-96m) Void fraction in stack (height 96-12m) 1.1 1.5 Void fraction in stack (height -24m) Void fraction in stack (height 24-48m) Void fraction in stack (height 48-72m) Void fraction in stack (height72-96m) Void fraction in stack (height 96-12m) 1 1.995.995.99 9: 9:3 1: 1:3 11:.99 9: 9:3 1: 1:3 11: Case A Case B Figure 9 Gas volumetric fraction changes in the stack f. Fraction of vent gas having flowed into Unit-4 R/B Figure 1 shows the fraction of vent gases that flowed into the Unit-4 R/B. The fractions were about 35% in both cases, irrespective of gaseous partial pressures in the PCV. The earlier study of TEPCO [1] evaluated that about 29% of all the vent gases had flowed to Unit-4. The result of the current study is close to this earlier result but there is a discrepancy of several percent. The difference is considered to come mainly from the different approaches to obtain the pressure losses at the piping bend section. In the earlier study, the piping bend section was modelled as a sharp elbow as illustrated in Figure 11 (A), while in the current study it was modelled as a curved bend as in Figure 11 (B) to simulate the section as realistically as possible. The pressure losses at this section are lower in the current study than in the earlier study. As seen in Figure 1, the SGTS line of Unit-4 had many bends. As the result, the vent gas flows to Unit-4 are considered to have been facilitated more in the current study than in the earlier study. Attachment 3-1-14

Percentage ベントガスの流入割合 of Vent Gas Inflow Percentage 4 号機原子炉建屋へのベントガス流入割合 of Vent Gas Flowing into the Reactor Building ( ( of ケース Unit 1) 4 (case A) A) Percentage 4 号機原子炉建屋へのベントガス流入割合 of Vent Gas Flowing into the Reactor Building ( ( of ケース Unit 2) 4 (case B) B) 5% 45% 4% 35% 3% 25% 2% 15% 1% 5% % 9: 9:3 1: 1:3 11: Figure 1 Fraction of vent gas that flowed into Unit-4 R/B (A) Elbow Figure 11 (B) Bend Modelling of piping bend section g. Hydrogen inventory having flowed into Unit-4 R/B Figure 12 presents the total amount of hydrogen that flowed into the Unit-4 R/B; about 3 kg in Case A, and about 5 kg in Case B. The initial steam fraction in the S/C is considered to have been between the steam fractions of Case A and Case B. The real amount of hydrogen that flowed into the Unit-4 R/B can be also considered to have been between the total amounts above in Case A and Case B. It should be noted that the S/C pool water level at the time of venting could have been higher than the S/C mid-height (roughly at the normal level) assumed in the current study. As shown in Figure 13, the S/C water levels were recorded until 2: on March 12 (about 13 hours before the venting). The S/C water level could have even increased from the last recorded level, because the S/C spray continued after the final recording and the steam from the RPV might have condensed. The S/C water levels might have decreased, on the contrary, if the S/C water temperatures decreased or gaseous Attachment 3-1-15

Amount of 水素流入量 Hydrogen [kg] Inflow [kg] leakage occurred from the PCV. It becomes necessary to clarify the scenario based on the examination of reliabilities of measured S/C water levels, and consistency with PCV pressures and other parameters. If the S/C water level is to change, the S/C free volume is to change, the hydrogen amount to reproduce the measured PCV pressures is to change, and hence the amount of hydrogen, about 3 to 5 kg, estimated above has uncertainties. 6 Integrated Value of Amount of Hydrogen Inflow to the Reactor Building of Unit 4 号機原子炉建屋への水素流入量の積分値 4 (Case A) ( ( ケース1) A) Integrated Value of Amount of Hydrogen Inflow to the Reactor Building of Unit 4 号機原子炉建屋への水素流入量の積分値 4 (Case B) ( ( ケース2) B) 5 4 3 2 1 9: 9:3 1: 1:3 11: Figure 12 Total amount of hydrogen flows into Unit-4 R/B Possibility that the water level in the venting was higher Measured S/C water Level Last measured S/C water level obtained at 2: on March 12 (5.7 m from the bottom of the S/C)?? Water level set in the analysis Half the height of the S/C (4.45 m from the bottom of the S/C) Normal Water Level (4.15 m from the bottom of the S/C) Venting (around 9: a.m. on March 13) 3/11 12: 3/11 18: 3/12 : 3/12 6: 3/12 12: 3/12 18: : 6: 12: Figure 13 S/C water levels at the time of venting 4. Conclusion Upon estimating in-pcv conditions at Unit-3 based on measured plant parameters, Unit-3 vent gas behavior was analyzed using a thermal-hydraulic analysis code. About 35% of the hydrogen-rich vent gases was estimated to have flowed into the Unit-4 R/B. Attachment 3-1-16

The high likelihood was reconfirmed that these hydrogen-rich vent gases had caused the explosion of Unit-4 R/B. 5. Implications of safety measures at the Kashiwazaki-Kariwa Nuclear Power Station The current study has reaffirmed that measures are required to prevent the vented gas flows in reverse to buildings upon PCV venting (independence of vent lines must be secured). The filtered vent lines to be newly installed at the reactor units at Kashiwazaki-Kariwa Nuclear Power Station share no lines with other units and each line is isolated from any other lines of its own unit (Figure 14). Thus, the vent line independence is secured, and no vent gas flows into the R/B will occur upon the PCV venting. Separated from other systems (standby gas treatment system/ventilation and air conditioning system/enhanced pressureresistant vent) of the Unit Design where pipes are not shared with other Units, meaning any one Unit has no influence on the others. Filtered Vent The Unit Another Unit Figure 14 PCV vent lines at Kashiwazaki-Kariwa Nuclear Power Station References [1] Tokyo Electric Power Company, Fukushima Nuclear Accident Analysis Report (June 2, 212) [2] Government of Japan, Final report of the investigation committee on the accident at Fukushima nuclear power stations of Tokyo Electric Power Company (July 23, 212) [3] Masao Ogino (JNES), Study on the Issues about Hydrogen Explosion at Fukushima Daiichi NPS, Technical Workshop on TEPCO s Fukushima Daiichi NPP Accident Handouts, Tokyo, Japan (July 24, 212) [4] OECD/NEA, Benchmark Study of the Accident at the Fukushima Daiichi Nuclear Power Plant (BSAF Project) Phase I Summary Report (March 215) Attachment 3-1-17