June 3, Mr. Steven Grandmont, Chief Operating Officer Richcraft Group of Companies 2280 St. Laurent Boulevard Ottawa, Ontario K1G 4K1

Similar documents
March 25, Katherine Grechuta MCIP, RPP, LEED AP Planner FoTenn Planning & Urban Design 223 McLeod Street Ottawa, ON, K2P 0Z8. Dear Ms.

Dear Ms. Maw: Qualitative Pedestrian Level Wind Assessment St-Charles Market, 135 Barrette Street, Ottawa GWE File No.

Dear Mr. Nicolini: Qualitative Pedestrian Level Wind Assessment Montreal Road, Ottawa GWE File No.: DTPLW

Brad Caco Group M8X 2X9. Mr. Caco: Gradient. for mitigation

SITE AND BUILDING INFORMATION. March 28, 2018

Computer-Based Pedestrian Level Wind Study Scott Street. Ottawa, Ontario

Pedestrian Level Wind Study. 383 Slater Street / 400 Albert Street. Ottawa, Ontario

Preliminary Pedestrian Level Wind Study. Elmvale Acres Shopping Centre Redevelopment. Ottawa, Ontario

Pedestrian Level Wind Study. 383 Slater Street. Ottawa, Ontario

Pedestrian Level Wind Study. 409 Brant Street. Burlington, Ontario

SITE AND BUILDING INFORMATION

Preliminary Pedestrian Level Wind Study. Westgate Shopping Centre Redevelopment. Ottawa, Ontario

Pedestrian Level Wind Study. Greystone Village 10 Oblats Avenue. Ottawa, Ontario

Pedestrian Level Wind Study. Westgate Shopping Centre Redevelopment, Phase 1. Ottawa, Ontario

Pedestrian Level Wind Study. 83 East Street. Oakville, Ontario

Pedestrian Level Wind Study. 398, 402, 406 Roosevelt Avenue. Ottawa, Ontario

31/10/17. October 31, HIP Developments Inc. 700 Rupert Street Waterloo, ON N2V 2B5

Pedestrian Level Wind Study. 979 Wellington Street West. Ottawa, Ontario

Pedestrian Level Wind Study. 350 Sparks Street. Ottawa, Ontario

Pedestrian Level Wind Study. Château Laurier Hotel Addition. Ottawa, Ontario

Pedestrian Level Wind Study Bank Street. Ottawa, Ontario

Pedestrian Level Wind Study. 12 Stirling Avenue. Ottawa, Ontario

Urban Design Terms of Reference. Pedestrian. Wind Comfort and Safety Studies. June 2014

23/02/18. Pedestrian Wind Assessment Ladies Golf Club of Toronto Markham, Ontario Novus Project # February 23, 2018

Appendix 7. Wind and Comfort Impact Analysis

Wellington Street : Wind Impact Qualitative Assessment. To Whom It May Concern, RE: Proposed Wellington Street Wind Impact Qualitative Assessment

Fig$1.!Wind!Rose!Shearwater! ! August 7th, 2015

1700 Webster Street Oakland, CA. Final Report. Pedestrian Wind Conditions Consultation Wind Tunnel Tests RWDI # July 16, 2015

Subject: Wind Impact Evaluation for the Facebook Campus Project, Menlo Park

Wind Microclimate Assessment

Donald Ballanti, Certified Consulting Meteorologist, Wind Impact Evaluation for the Menlo Park Facebook Campus Project, August 26, 2011.

2 Bowen Crescent Residential Development, Melbourne

APPENDIX 11 WIND EFFECTS ASSESSMENT

Pedestrian Wind Impact Study for Atlantic Yard Area & Redevelopment Project NEWMERICAL TECHNOLOGIES INTERNATIONAL.

Assembly Committee Document 7.5

Background Preliminary Review... 3

Technical Brief - Wave Uprush Analysis Island Harbour Club, Gananoque, Ontario

Urban Environmental Climate Maps for Urban Planning Considering Urban Heat Island Mitigation in Hiroshima

Pedestrian Level Wind Study. 159 Parkdale Avenue. Ottawa, Ontario

UDB. Urban Design Brief (Continued - Section 6) 137 and 141 George Street, 321 Dalhousie Street May 2013

TABLE OF CONTENTS EXECUTIVE SUMMARY THE PROJECT INTRODUCTION SITE DESCRIPTION NOISE SENSITIVE RECEPTORS...

Opus Research Report D Wind Tunnel Study of the Proposed Site 10 Development, Wellington

Wind Resource Assessment for NOME (ANVIL MOUNTAIN), ALASKA Date last modified: 5/22/06 Compiled by: Cliff Dolchok

Prepared For: Shieldbay Developments Inc. c/o Matson, McConnell Ltd. 2430A Bloor Street West Toronto, Ontario M6S 1P9.

7 NE 145TH STREET STATION TOD POTENTIAL

Re: Wind Impact Assessment Marina del Rey Tower Marina del Rey, California RWDI Reference No Description of Proposed Development

DOWNBURST CHARACTERISTICS

Technical Memorandum. I. Introduction and Overview. Nancy Clark Turnstone Consulting 330 Townsend Street, Suite 216 San Francisco, CA 94107

Arapahoe Square Zoning + Design Standards & Guidelines Task Force Meeting 9 January 27, 2016

Improving Cyclist Safety at the Dundas Street West and Sterling Road Intersection

300 George Street, Brisbane Pedestrian Level Winds - Wind Tunnel Test

Generation of an Annual Typical Daily Wind Speed for Heights Equal and Less than 10 meters for Urban Armidale NSW, Australia

TRAFFIC SIGNAL WARRANT STUDY

RE: 100 VARLEY LANE TRANSPORTATION OVERVIEW

Public Workshop #2. September 14, 2016

Currents measurements in the coast of Montevideo, Uruguay

Technical Brief - Wave Uprush Analysis 129 South Street, Gananoque

City of Margate, Florida. Neighborhood Traffic Management Manual

7/23/2017 VIA . Michael Hanebutt City of Sacramento Community Development Department 300 Richards Boulevard, 3 rd Floor Sacramento, CA 95811

HENDERSON DEVELOPMENT 213, 217, 221, 221 ½, 223 HENDERSON AVENUE and 65 TEMPLETON STREET OTTAWA, ONTARIO TRANSPORTATION OVERVIEW.

Garden City State Street Corridor Existing Conditions October 2012

DESIGN CODE. Enterprise West Harlow London Road North Design Code 21

NordFoU: External Influences on Spray Patterns (EPAS) Report 16: Wind exposure on the test road at Bygholm

Traffic Calming Rosemount Avenue, between Ralph Street and Queenslea Avenue

5858 N COLLEGE, LLC N College Avenue Traffic Impact Study

5. MODIFICATIONS AT JEANNE D ARC BOULEVARD/REGIONAL ROAD 174 INTERCHANGE INTERSECTION - PUBLIC HEARING COMMITTEE RECOMMENDATION

Marina Loft (DRC 51-R-12)

OFFICE/RETAIL DEVELOPMENT 1625 BANK STREET OTTAWA, ONTARIO TRANSPORTATION BRIEF. Prepared for: Canada Inc.

HILTON GARDEN INN HOTEL HOTEL EXPANSION 2400 ALERT ROAD, OTTAWA TRANSPORTATION BRIEF. Prepared for:

Route 7 Corridor Study

An Overview of Wind Engineering Where Climate Meets Design

May 5, 2009 File:

Techniques to achieve wind comfort & wind loads on buildings and appurtenances

FAIRFIELD INN & SUITES HOTEL 135 THAD JOHNSON PRIVATE OTTAWA TRANSPORTATION BRIEF. Prepared for:

DUNBOW ROAD FUNCTIONAL PLANNING

Traffic Impact Memorandum. May 22, 2018

Aspects of Using CFD for Wind Comfort Modeling Around Tall Buildings

MEDICAL/OFFICE BUILDING 1637 BANK STREET OTTAWA, ONTARIO TRANSPORTATION OVERVIEW. Prepared for:

Strolling down the Avenue

CastleGlenn Consultants Inc.

WEATHER SYSTEMS OF MIDDLE LATITUDES

APPENDIX C: Wind and Wave Modelling

Duckies have been found in Hawaii, Alaska, S. America, Scotland, Washington state and Australia as of 2012.

MARLWOOD GOLF & COUNTRY CLUB WASAGA BEACH, ONTARIO

FINAL REPORT. Wind Assessment for: NEW OFFICE BUILDING AT ESSENDON FIELDS Essendon, Victoria, Australia

Chapter 5 DATA COLLECTION FOR TRANSPORTATION SAFETY STUDIES

Design Features to Change and/or Ameliorate Pedestrian Wind Conditions. Leighton Cochran 1 PhD CPEng

Lake Michigan Wind Assessment Project Data Summary and Analysis: October 2012

ESTIMATION OF THE DESIGN WIND SPEED BASED ON

Comments EXECUTIVE SUMMARY

4 DISRUPTION MANAGEMENT PLAN HIGHWAY 7 RAPIDWAY CONSTRUCTION BETWEEN BAYVIEW AVENUE AND WARDEN AVENUE TOWNS OF MARKHAM AND RICHMOND HILL

MEETING Agenda. Introductions. Project Overview. Key Study Components. Alternative Station Concepts. Preferred Station Concept. Next Steps.

Effects of directionality on wind load and response predictions

STATE OF VERMONT ENVIRONMENTAL COURT } } } } } Decision and Order

Traffic Calming St. Clarens Avenue between Brandon Avenue and Davenport Road

DEPARTMENT OF COMMUNITY PLANNING, HOUSING AND DEVELOPMENT Planning Division/Site Plan Review Committee

E. Agu, M. Kasperski Ruhr-University Bochum Department of Civil and Environmental Engineering Sciences

The proposed development is located within 800m of an existing Transit Station where infill developments and intensification are encouraged.

Transportation Impact Study for Abington Terrace

Advisory Circular. Legal Land Survey for AZR Clearance Attestation

Transcription:

June 3, 2013 Mr. Steven Grandmont, Chief Operating Officer Richcraft Group of Companies 2280 St. Laurent Boulevard Ottawa, Ontario K1G 4K1 Dear Mr. Grandmont: Re: Qualitative Pedestrian Wind Assessment 250 & 274 Parkdale Avenue, Ottawa GmE File Ref.: 13-052-DTPLW 1. INTRODUCTION Gradient Microclimate Engineering Inc. (GmE ) was retained by Richcraft Group of Companies to undertake a qualitative pedestrian level wind assessment for a proposed dual-tower mixeduse development to be located at 250 and 274 Parkdale Avenue in Ottawa, Ontario. This report provides a qualitative assessment of pedestrian wind comfort for the noted site based on architectural drawings provided by Roderick Lahey Architect Inc. in May 2013, a review of existing surrounding context, statistical knowledge of the Ottawa wind climate, and experience with similar past projects in Ottawa. A qualitative wind assessment, as distinct from the more elaborate wind tunnel or computational study, is suitable to identify potential pedestrian comfort issues at an early design stage, and develop mitigation strategies as may be necessary. 127 Walgreen Road, Ottawa, Ontario K0A 1L0 Tel.: (613) 836-0934 Fax: (613) 836-8183 www.gradientwind.com

2. TERMS OF REFERENCE The focus of this qualitative wind assessment is a planned dual-tower development to be located at 250 and 274 Parkdale Avenue in Ottawa, Ontario. The site is situated on a parcel of land bounded by Parkdale Avenue to the east, Bullman Street to the south, Holland Avenue to the west, and Scott Street to the north. The rectangular and semi-elliptical plan-form towers of thirty-two (32) and twenty-eight (28) storeys, respectively identified as tower A (250 Parkdale Avenue) and tower B (274 Parkdale Avenue), rise from independent four (4) storey podia with the long axis of their rectangular floor plates rotated 8 degrees clockwise from the centerline of Scott Street. Multiple levels of below-grade parking are scheduled for each development, with egress/ingress provided via ramp access at the northwest corner of tower A from Scott Street, as well as at the southwest corner of tower B from Bullman Street. An amenity terrace is located atop the podium roof of tower B, while both towers A and B are served by mechanical penthouses. Regarding wind exposure, the study buildings are surrounded in close proximity by lower commercial and residential buildings to the west, south and east, and a cluster of mid-height commercial and mixed-use buildings to the north, located north of Scott Street. At greater distances, referred to as the far field, the site is surrounded by the Ottawa River to the north and low-rise residential properties for most other directions. As such, the existing massing creates generally suburban wind exposures for the northeast clockwise through to southwest quadrants, and hybrid suburban-open exposures for the remaining cardinal directions. With respect to pedestrian winds, key areas under investigation include the public sidewalks along Parkdale Avenue and Scott Street, the main entrances and exit doors for both buildings, and the noted tower B podium roof amenity terrace. A hybrid roof plan and ground floor plan is provided in Figure 1. 250 & 274 Parkdale Avenue, Ottawa Qualitative Pedestrian Wind Assessment Page 2

3. METHODOLOGY The following section describes the analysis process, including a background discussion of pedestrian comfort. The essential aspects of a qualitative wind analysis include: (i) consideration of the statistical properties of the local wind climate; (ii) consideration of the massing of the site (i.e., the shape, height and orientation of the buildings); and (iii) estimation of anticipated pedestrian comfort conditions based on in-house experience. 3.1 Meteorological Data Analysis A statistical model of the Ottawa wind climate, indicating the directional character of local winds on a seasonal basis, is presented on the following page. The plots illustrate three contours representing three probability levels superimposed on a polar grid of wind speed at gradient height in metres/second (m/s). The three contours represent the mean hourly wind speed occurring once per month (innermost contour), once per year and once every ten years (outermost contour). The preferred wind directions can be identified as the angular position where the given contour has the largest radial distance from the centre. For Ottawa, the most common winds occur for westerly wind directions, followed by those from the east; the directional preferences and corresponding wind speeds vary seasonally. By convention in microclimate studies, wind direction refers to the wind origin (e.g., a north wind blows from north to south). 250 & 274 Parkdale Avenue, Ottawa Qualitative Pedestrian Wind Assessment Page 3

SEASONAL DISTRIBUTION OF WINDS FOR VARIOUS PROBABILITIES MACDONALD-CARTIER INTERNATIONAL AIRPORT, OTTAWA WINTER 25.0 N SPRING 25.0 N NW 20.0 15.0 NE NW 20.0 15.0 NE 10.0 10.0 5.0 5.0 W 0.0 E W 0.0 E SW SE SW SE S S SUMMER 25.0 N AUTUMN 25.0 N NW 20.0 15.0 NE NW 20.0 15.0 NE 10.0 10.0 5.0 5.0 W 0.0 E W 0.0 E SW SE SW SE S S Notes: 1. Radial distances indicate wind speed in metres/second at a height of 10 m above grade. 2. A point along the innermost contour represents the wind speed exceeded on average 0.1% of the time within a 10 sector centered on that direction. 3. The middle and outermost contours represent probability levels of 0.01% and 0.001%, respectively. 250 & 274 Parkdale Avenue, Ottawa Qualitative Pedestrian Wind Assessment Page 4

3.2 Pedestrian Wind Comfort Criteria Pedestrian comfort criteria are based on mechanical wind effects without consideration of other meteorological conditions (e.g., temperature, relative humidity). The criteria provide an assessment of comfort, assuming that pedestrians are appropriately dressed for a specified outdoor activity during any given season, and are based on statistical progression. Five pedestrian comfort classes and corresponding gust wind speed ranges are used to assess pedestrian comfort, which include: (i) Sitting; (ii) Standing; (iii) Walking; (iv) Uncomfortable; and (v) Dangerous. More specifically, the comfort classes, associated wind speed ranges and limiting criteria are summarized as follows: i) Sitting Wind speeds below 14 km/h (i.e. 0-14 km/h), occurring more than 70% of the time, are acceptable for sedentary activities, including sitting. ii) Standing Wind speeds below 22 km/h (i.e. 0-22 km/h), occurring more than 80% of the time, are acceptable for activities such as standing, strolling or more vigorous activities. iii) Walking Wind speeds below 30 km/h (i.e. 0-30 km/h), occurring more than 80% of the time, are acceptable for walking or more vigorous activities. iv) Uncomfortable Uncomfortable conditions are characterized by predicted values that fall below the 80% criterion target for walking. Brisk walking and exercise, such as jogging, would be acceptable for moderate excesses of this criterion. v) Dangerous Wind speeds greater than 90 km/h, occurring more than 0.01% of the time, are classified as dangerous. From calculations of stability, it can be shown that gust wind speeds of 90 km/h would be the approximate threshold that would cause an average elderly person in good health to fall. The wind speeds associated with the above categories are gust wind speeds. Corresponding mean wind speeds are approximately calculated as gust wind speed divided by 1.5. Gust speeds are used in the criteria because people tend to be more sensitive to wind gusts than to steady winds for lower wind speed ranges. These criteria are applied according to the intended use of the outdoor area. For example, an entrance to a building without a vestibule should be suitable for standing, but need not be suitable for sitting. 250 & 274 Parkdale Avenue, Ottawa Qualitative Pedestrian Wind Assessment Page 5

3.3 Massing vs. Climate Geometric Effects Physical features of a site that influence the local wind microclimate include: the density of surrounding buildings, the massing of the study site and the geometry of the study building(s). Massing density typically increases over time, which can provide greater shielding to wind and calmer wind conditions at grade. For the study site, pedestrian comfort will primarily be influenced by winds originating from the northwest counterclockwise through to southwest, as well as from the east. Although the remaining wind directions have a lower statistical frequency of occurrence, strong wind flows associated with multiple low probability wind directions can cumulatively influence pedestrian comfort. Based on the orientation of the development relative to prominent wind directions, the form of the study buildings, and in-house knowledge of common wind impacts, moderate wind conditions at grade level are generally expected to be acceptable for anticipated pedestrian uses. Specific wind conditions for the study site are discussed in the following section. 250 & 274 Parkdale Avenue, Ottawa Qualitative Pedestrian Wind Assessment Page 6

4. ANTICIPATED PEDESTRIAN COMFORT Based on the massing of the study site, surrounding building massing and the orientation to the local wind climate, the following statements summarize our experience of how these conditions affect pedestrian comfort in key areas around the site. Tower A Main Residential and Retail Entrances, Exit Door and Ramp Access to Below- Grade Parking on North Façade; Scott Street Sidewalk (Figure 1, Tags A and B): The main residential entrance for tower A is located on the north façade and is served by a vestibule, while a dedicated retail entrance is located at the northeast corner of the podium. Ramp access to below-grade parking is located to the immediate west of the main residential entrance, while a stairwell exit is flanked by the noted entrances. All noted tower A access points, which are identified as Tag A in Figure 1, front onto Scott Street. Given that the 5 th floor of the podium overhangs the ground floor, the noted access points are adequately protected from downward flow coming off the 32-storey tower A. Additional features that are favourable with respect to pedestrian comfort at grade include the density of upwind suburban massing to the east and west, as well as the sufficient distance between the proposed development and the south shoreline of the Ottawa River. As a result, wind conditions at the main entrance, retail entrance and stairwell exit are expected to be suitable for sitting during the summer and autumn seasons, and suitable for standing during the remaining colder months. The noted conditions are considered to be acceptable. For the Scott Street sidewalk area, identified as Tag B in Figure 1, slightly windier conditions suitable for sitting during the summer months, standing during the autumn, and suitable for walking, or better, during the remaining colder months are anticipated; conditions which are nonetheless considered acceptable for the anticipated pedestrian uses. 250 & 274 Parkdale Avenue, Ottawa Qualitative Pedestrian Wind Assessment Page 7

Exit Doors on East Façade of Towers A and B, and Retail Entrance on East Façade of Tower B; Parkdale Avenue Sidewalk (Figure 1, Tags C and D): The east elevations of towers A and B, identified as Tag C in Figure 1, include stairwell exits for towers A and B, as well as a single retail entrance for tower B. Although the east elevations are primarily exposed to prominent east winds, the suburban upwind massing will tend to create an increase in turbulence, which will benefit pedestrians located near to the east elevations of both towers A and B. Additionally, with the inclusion of coniferous and deciduous plantings along Parkdale Avenue, oncoming winds will be further mitigated. Therefore, considering the noted impact of the planned landscaping, wind conditions are anticipated to be suitable for sitting during the summer and autumn seasons, and suitable for standing during the remaining colder months. The standing criterion is considered acceptable for retail entrances and building exits. For the Parkdale Avenue sidewalk area, identified as Tag D in Figure 1, wind conditions are expected to be similar to those reported for the Scott Street sidewalk area. More specifically, wind conditions are expected to be suitable for sitting during the summer, standing during the autumn, and suitable for walking, or better, during the remaining colder seasons. Since the walking criterion is considered acceptable and appropriate for public sidewalks, the noted conditions are acceptable. Tower B Main Residential and Retail Entrances, Exit Door and Ramp Access to Below- Grade Parking on South Façade; Bullman Street Sidewalk (Figure 1, Tags E and F): The entrance providing access to the residential lobby, as well as a dedicated retail entrance, are served by vestibules and located on the south façade of tower B. Ramp access to below-grade parking is located at the southwest corner of the tower B development, while a stairwell exit is flanked by the noted entrances. All noted tower B access points, which are identified as Tag E in Figure 1, front onto Bullman Street. Given that the tower is setback from its podium, the noted access points are adequately protected from downward flow coming off the 28-storey tower B. Additionally, the density of upwind suburban massing to the east and west will tend to create an increase in turbulence, which will benefit pedestrians located near to the tower s south façade. As a result, wind conditions at the main entrance, retail entrance and stairwell exit are expected to be suitable for sitting during the summer and autumn seasons, and suitable 250 & 274 Parkdale Avenue, Ottawa Qualitative Pedestrian Wind Assessment Page 8

for standing during the remaining colder months. The noted conditions are considered to be acceptable. For the Bullman Street sidewalk area, identified as Tag F in Figure 1, slightly windier conditions suitable for sitting during the summer months, standing during the autumn, and suitable for walking, or better, during the remaining colder months are anticipated; conditions which are nonetheless considered acceptable for the anticipated pedestrian uses. West Elevations of Towers A and B; Laneway (Figure 1, Tags G and H): The west elevations of both towers A and B, identified as Tag G in Figure 1, are exposed to statistically prominent southwest clockwise through to northwest winds. The wind conditions are anticipated to be suitable for sitting during the summer, standing during the autumn, and suitable for walking during the remaining colder months. With respect to the architectural drawing set, although no building access points are scheduled to occupy the west elevations of towers A and B at ground level, wind conditions suitable for walking, or better, are considered acceptable and appropriate. For the laneway formed between towers A and B, which is identified as Tag H in Figure 1, the potential for accelerated wind flow is created by the massing of the proposed towers in combination with statistically prominent westerly winds. The resulting wind conditions are expected to be similar to those anticipated for the Parkdale Avenue sidewalk area. More specifically, acceptable conditions suitable for sitting during the summer months, standing during the autumn, and suitable for walking, or better, during the remaining colder months are expected. 250 & 274 Parkdale Avenue, Ottawa Qualitative Pedestrian Wind Assessment Page 9

Terrace atop 4-Storey Podium of Tower B: The large private terrace atop the 4-storey segment of tower B is exposed to all prominent winds. As such, moderately strong wind conditions are anticipated year round which will not be conducive to prolonged sitting or lounging. Given that the terrace area and landscape plan are not defined at this time, mitigation may or may not be required. If the terrace is located closer to the edge of the roof and intended for extended sitting, dining or other long-term sedentary activity, extensive mitigation may not be required. However, if the terrace is located close to tower B, mitigation in the form of building canopies, vertical windscreens and/or dense coniferous plantings would likely be required due to the expected increases in both vertical and horizontal air flow caused by the tower s elliptically-shaped north façade. More specific comments can be provided once terrace details are known. Within the context of typical weather patterns (excluding severe local storm events, such as thunderstorms, tornadoes and downbursts), no dangerous or consistently strong wind conditions are expected anywhere over the subject site on a seasonal, nor on an annual, basis. During severe events, pedestrians are expected to seek shelter and not linger at outdoor spaces. 250 & 274 Parkdale Avenue, Ottawa Qualitative Pedestrian Wind Assessment Page 10

5. SUMMARY AND RECOMMENDATIONS This assessment was performed in accordance with the scope of work outlined in GmE proposal #13-072P, dated May 9 th, 2013. Based on the qualitative analysis of site plans, building forms and the local climate, the following statements summarize our interpretation of future wind conditions for the subject site massing. In general terms, the anticipated wind conditions at grade surrounding the proposed 32-storey tower A and 28-storey tower B are expected to be suitable for the intended pedestrian uses over all areas at grade. However, for the large private terrace atop the 4-storey segment of tower B, mitigation in the form of building canopies, vertical windscreens and/or dense coniferous plantings may be required depending on the final location and its intended use. However, with the noted mitigation measures in place, most terrace locations can be configured to create comfortable conditions for outdoor occupant use. The foregoing analysis and statements are based on experience and knowledge of wind flow patterns in suburban settings. While the statements and conclusions relating to pedestrian safety are expected to be reliable for the site as a whole, the evaluation of comfort is more difficult to assess due to the limitations of visualizing local wind flows, as well as the variable physiological response of pedestrians to similar environmental conditions. As a result, this assessment is intended to assure adequate pedestrian safety relating to wind, while providing general guidance relating to pedestrian comfort around the subject site. This concludes our pedestrian level wind assessment and report. Please advise the undersigned of any questions or comments. Sincerely, Gradient Microclimate Engineering Inc. Justin Ferraro, B.Eng., EIT Project Manager GmE 13-052-DTPLW Vincent Ferraro, M.Eng., P.Eng. Principal 250 & 274 Parkdale Avenue, Ottawa Qualitative Pedestrian Wind Assessment Page 11