Risk Assessment of Severe Accidents Involving Atmospheric Dispersion of Anhydrous and Hydrous Ammonia mixtures

Similar documents
Applying Proper Dispersion Models for Industrial Accidental Releases

Part 2.5 Dispersion Modeling Using ALOHA

APPENDIX A: SENSITIVITY TESTS INPUTS AND SETUP TABLES

REAL-TIME MODELING DURING EMERGENCY SITUATIONS IS THIS A GOOD IDEA?

Identification and Screening of Scenarios for LOPA. Ken First Dow Chemical Company Midland, MI

MODEL VALIDATION AGAINST THE MODELERS DATA ARCHIVE

PURE SUBSTANCE. Nitrogen and gaseous air are pure substances.

Deep water plume models - What s special about deep water

Chapter 3 Atmospheric Thermodynamics

ERCBH2S Frequently Asked Questions.

Transient Analyses In Relief Systems

Practical Modelling & Hazard Assessment of LPG & LNG Spills

Tel: FAX: Risk Assessment for Exposure to Respirable Dusts Generated from the Use of Chalks and Pastels

PHYS 101 Previous Exam Problems

Fig. 2. M.I. Yaroslavtsev, 2002

H13-89 DISPERSION MODELING OF ACCIDENTAL TOXIC GAS RELEASES A MODEL COMPARISON STUDY.

Atmospheric Dispersion, Transport and Deposition. Dispersion. Wind Speed. EOH 468 Spring 2008 Dr. Peter Bellin, CIH, Ph.D.

HYDROGEN RISK ANALYSIS FOR A GENERIC NUCLEAR CONTAINMENT VENTILATION SYSTEM

Improving Accuracy of Frequency Estimation of Major Vapor Cloud Explosions for Evaluating Control Room Location through Quantitative Risk Assessment

Computational Analysis of Oil Spill in Shallow Water due to Wave and Tidal Motion Madhu Agrawal Durai Dakshinamoorthy

DIGITAL SOLUTIONS TRAINING CATALOGUE. QRA and CFD simulation. Phast, Safeti and KFX SAFER, SMARTER, GREENER

Development of an Oil Delivery System to Create Neutrally Buoyant Oil Plumes

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Evaluation of Northwest Citizen Science Initiative (NWCSI) March 7,2015 Report Summary

Fluid Mechanics. Liquids and gases have the ability to flow They are called fluids There are a variety of LAWS that fluids obey

1. The principle of fluid pressure that is used in hydraulic brakes or lifts is that:

Ballast Water Management Technologies A Brief Review

Chemistry 51 Chapter 7 PROPERTIES OF GASES. Gases are the least dense and most mobile of the three phases of matter.

1200 New. Jersey Ave., SE. producers. and potassium. A. Summary. the

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Using Consequence Modeling to Help Make Emergency Decisions

Chapter 9 Solids and Fluids

TABLE OF CONTENTS EXECUTIVE SUMMARY THE PROJECT INTRODUCTION SITE DESCRIPTION NOISE SENSITIVE RECEPTORS...

Abstract. 1 Introduction

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

Gas Accumulation Potential & Leak Detection when Converting to Gas

ON THE EFFECT OF LIFT FORCES IN BUBBLE PLUMES

4. Using the kinetic molecular theory, explain why a gas can be easily compressed, while a liquid and a solid cannot?

SUMMARY OF THE EXPERIMENTAL STUDIES OF COLD HELIUM PROPAGATION ALONG A SCALE MODEL OF THE LHC TUNNEL

Process Safety Management Of Highly Hazardous Chemicals OSHA 29 CFR

Università di Pisa Facoltà di Ingegneria Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione. Emergency Planning.

Honors Chemistry - Problem Set Chapter 13 Classify each of these statements as always true, AT; sometimes true, ST; or never true, NT.

Are Detonator Qualification and Lot Acceptance Test Requirements Rational?

Kinetic Molecular Theory

Hazardous material transport accidents: analysis of the D.G.A.I.S. database

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006

1. All fluids are: A. gases B. liquids C. gases or liquids D. non-metallic E. transparent ans: C

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System

Chemistry 20 Unit 2 Gases FITB Notes. Topic A Characteristics of Gases

Composition of Exhaled Breath

Challenges in Relief Design for Pilot Plants

Introduction to consequence modelling

Blast Damage Consideratons for Horizontal Pressure Vessel and Potential for Domino Effects

Old-Exam.Questions-Ch-14 T072 T071

Temperature Influence on the Flammability Limits of Heat Treating Atmospheres

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

USING PREDICTIVE RISK ASSESSMENTS TO DEVELOP USER-FRIENDLY TOOLS FOR ON- AND OFF-SITE EMERGENCY PLANNING



The «practical elimination» approach for pressurized water reactors

Quiz name: Chapter 13 Test Review - Fluids

ALOHA. Instructor Manual AREAL LOCATIONS OF HAZARDOUS ATMOSPHERES U.S. ENVIRONMENTAL PROTECTION AGENCY NATIONAL OCEANIC AND ATMOSPHERIC ADMINSTRATION

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Thermodynamics ERT 206 Properties of Pure Substance HANNA ILYANI ZULHAIMI

Judith Herzfeld 1996,1998. These exercises are provided here for classroom and study use only. All other uses are copyright protected.

ATMO 551b Spring Flow of moist air over a mountain

OIL AND GAS INDUSTRY

TECHNICAL BULLETIN CRYOGENIC APPLICATION SERVICES. website:

Rail Car Unloading Case Study

ERCBH2S A Model for Calculating Emergency Response and Planning Zones for Sour Gas Wells, Pipelines, and Production Facilities.

This test shall be carried out on all vehicles equipped with open type traction batteries.

Day 1 What Is Air Pressure? November 28, 2017

Hydrogen Bubble Dispersion and Surface Bursting Behaviour

Transfeu WP2 Subtask Development of small-scale test method for fire effluents

HYDROGEN - METHANE MIXTURES : DISPERSION AND STRATIFICATION STUDIES

I.CHEM.E. SYMPOSIUM SERIES NO. 97 BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES

Heat Pump Connections and Interior Piping

LABORATORY EXERCISE 1 CONTROL VALVE CHARACTERISTICS

Module 03 Accident modeling, risk assessment and management Lecture 04 Explosions

Separate Effect Experiment on Density Gradient Driven Flow in VHTR Small Break Air Ingress Accident

In the liquid phase, molecules can flow freely from position to position by sliding over one another. A liquid takes the shape of its container.

Addendum 4 Levels of Response

Application Note AN-107

CANUTEC ERG2008 Emergency Response Guidebook (ERG) initial response phase

ALOHA. Example Scenarios. September 2016

In the liquid phase, molecules can flow freely from position. another. A liquid takes the shape of its container. 19.

Guide for Evaluating Your Hose Assembly Supplier

5.0 Neutral Buoyancy Test

Ballot ID: Action item Reference Number: Addition of common causes and susceptibility diagram to API RP 581, 3rd Edition, Section 12

MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY

Emission Inventory Evaluation Using DISCOVER-AQ Aircraft Data

Fall 2004 Homework Problem Set 9 Due Wednesday, November 24, at start of class

STUDY ON THE SAFETY MANAGEMENT OF TOXIC GAS CYLINDER DISTRIBUTION USING RFID

Journal of Applied Fluid Transients, Vol 1-1, April 2014 (3-1)

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

DEVELOPMENT AND TESTING OF AIR EXCHANGE RATE METHODS TO IMPROVE COST EFFECTIVENESS WHILE MAINTAINING ACCURACY

Time Pressure Dispensing

Experiment 18 Properties of Gases

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

Transcription:

ד"ר אלי שטרן הערכה, ניתוח וניהול סיכונים סביבתיים Dr. Eli Stern Assessment, Analysis & Management of רח' הרצפלד,22 קרית אונו; Israel ; 22 Herzfeld St., Kiriat Ono 5556022, Phone (mobile): +972-(0)52-8187678; Tel: +972-(0)3-5345313; Fax: +972-(0)3-7369887 E-mail: elistern49@gmail.com Risk Assessment of Severe Accidents Involving Atmospheric Dispersion of Anhydrous and Hydrous Ammonia mixtures By: Dr. Eli Stern Presented at Ammonia World New and Old 2017 conference Technion, Haifa, Israel 15.11.17

Background Large parts of this presentation provide a succinct overview of the main issues analyzed in a study performed by the author, under an Israel MOEP Contract. A deep, detailed study was needed, inter alia, to provide an alternative to the 10 Scientists Report published in summer 2016, contending that a severe accident in an ammonia ship, carrying some 16,000 tons of anhydrous ammonia (atmospheric tanks, -33.5 C), is a potential ultra-killer, equivalent to simultaneous detonation of five nuclear bombs (Hiroshima Type), causing 600,000 casualties (most of them fatalities), including possible total massacre of the entire Technion and Haifa University personnel. The study was not a classical regulatory type one fits all risk assessment, focusing on pre-defined representative, rather realistic, accidental events involving large releases of hazardous materials from storage tanks, chemical processes, transportation etc.; It focused on rather severe, low probability, operational - accidental events (10-6/y and less), thus helping in assessing the public acceptability of a small ammonia ship (see below). As a side benefit, this study (if properly interpreted and prudently implemented) can possibly serve as a useful tool for assessing the consequences of possible hostile, malevolent, acts, aiming to cause severe damage to the ship and consequently, to surrounding population as well. In general, extremely severe accidents are not necessarily DBAs (design basis accidents) from operational point of view, but could be such, or modified to be such, if e.g. it is decided to account for (i.e. to design against) various kinds of nonoperational accidents, including natural disasters and hostile acts.

Which? Why? Which Accidents were chosen for risk assessment of a small ammonia ship (two atmospheric tanks, up to 1250 tons each)? - Spill of contents onto water surface - GB (guillotine break, full bore hole) in the 1 km, 10 pipe (100 tons/hr) - Direct spill into a bund due to pipe failure (evaporation) Why? - Help in overall investigation of the Risk Acceptability of the small ship option (in terms of Individual Risks to be compared to international widely acceptable acceptability criteria ) - Court involvement - Public fear - Better insight into possible outcomes of malevolent acts as well as non-operational accidental events.

Anhydrous and Hydrous Ammonia Risk Assessment Issues and Parameters Issue/Parameter Spill characteristics, including spill area; Duration of release (evaporation); Consideration in current study Yes Comments Basically from USCG 1974 (ADL) Instantaneous/continuous dispersion modeling Yes Instantaneous - from the spill; Continuous - from the 10 pipe Guillotine Break; NH 3 Plume Rise Yes From USCG 1974 (ADL) and other sources NH 3 high altitude movement towards a mountain. NH 4 OH Formation Yes Specific Modeling Yes Exposures at points hit by the plume NH 4 OH Plume Rise No NH 4 OH is assumed to crawl very close to sea/water surface. Conservative (?) approach Virtual Source considerations Yes Crucial (because of the dimensions of water surface puddle) Diffusional dry deposition No Conservative approach Gravitational Settling No Ibid. PAC3 values NH 3 PAC3 values - NH 4 OH Yes Yes Exposure duration dependency Indoor exposures No In most cases, very conservative if ignored (see last slide below) Wind Rose Partially For individual risk estimations Operational accident probabilities Yes Ibid.

Dispersion of Anhydrous Ammonia from Large Spills Significantly lighter than air (M=17 Vs. 29) In cases of spills onto water surfaces additional buoyancy, driven by heat absorbed within water surface, due to exothermic hydrolysis of approximately half of the anhydrous ammonia. This may affect rates of evaporation as well. Significant plume rise, up to several hundred meters (as argued by several authors), can be expected. However, final plume heights are subject to modeling and may turn out to be quite uncertain and rather controversial. The main question to be resolved is the capability of droplets formation within the buoyant ammonia plume to cause the entire rising air + ammonia mixture, to gradually become heavier than air; and if really so, would the mixture tend to undergo slumping processes or (more reasonable) disperse horizontally in the downwind direction? Curves from USCG 1974 (AD 779 400, by ADL)

Hydrous Ammonia (NH4OH) formation and dispersion Basic Modeling Basic modeling - mainly for spills on water surfaces. Can be applied for spills on any surface Assumptions and data (1) (a) Hydrous ammonia is formed by immediate hydrolysis reaction of anhydrous ammonia evaporating from a puddle with water molecules present in ambient air, in either gas or liquid phase (droplets) (b) Maximum water content (corresponding to 100% relative humidity) 4% v/v (data) (c) Each water molecule present in a hypothetical cylinder located above the puddle (Rcyl= radius of the puddle; hcyl> 20m) is assumed to meet / hit an NH3 molecule, and hydrolyze immediately to form an NH4OH molecule. ******* Amounts of hydrous ammonia formed per unit time, within the hypothetical cylinder, depends on relative humidity and rates of NH3 evaporation (to be modeled separately) It should be emphasized NH4OH is not a gas; And it is not lighter than air. It will appear in the cylinder as liquid (droplets) or solid (icicles) particles; And will be subject to particulate aerosol dispersion patterns, depending on its AMAD (aerosol mean aerodynamic diameter) being greater or smaller than, say, 20-30 microns.

Hydrous Ammonia (NH4OH) formation and dispersion Basic Modeling (continued) Assumptions and Data (2) (a) All the NH4OH present in the above cylinder will disperse downwind, crawling above water/land surface. Any possible plume rise and any contributions from particles higher than 20 m are ignored (due to negligible additional doses at close public receptor locations, based on extensive, iterative, sensitivity analyses) (b) Dispersion is treated as puff, considering extremely short release (i.e. evaporation) durations obtained in USCG 1974 and separately in present, pertinent ALOHA runs (c) All NH4OH is assumed to have AMADs<20-30 micron (i.e. not subject to Gravitational Settling processes) (d) PAC3 value for NH4OH is 4 times greater than NH3 s (i.e. significantly less dangerous, based on US DOE tables (data)

Hydrous Ammonia (NH4OH) formation and dispersion Basic Modeling (Example) Example Spill 1000 tons of NH3 onto water Fractionation 50% dissolved in water; 50% evaporation Rpuddle 100 m Relative Humidity (air) 100%; Air water content 4% v/v Amount of NH4OH created within hyp. cyl. 30 tons (conservative) Duration of Release from puddle 2-6 min Mode of Dispersion - Gaussian, Puff. No plume rise. No depletion due to dry deposition. No gravitational settling; Virtual source considerations; Stability Conditions D(4), F(2) PAC3NH4OH - 10,000 mg/m3 (adjusted for 10 min. exposure to max. air concentration at a point); Main results Day conditions (D(4)) Exposure at 1000 m: 0.3 PAC3. Night conditions (F(2)) PAC3 at approximately 1500 m.

Plume Rise and Virtual Source For 0 height area sources (i.e. no plume rise) virtual source is considered for sigma Y For plume rise cases (see below, on left), virtual source is considered for sigma Z

Puff Dispersion from AIChE, CCPS (2000)

NH3 AEGLs/PACs as Function of Duration of Exposure

NH3 PAC3 Distances for any Plume Rise Height preliminary results D(4) conditions (dispersion above open water (left) and urban and forest (right)) Max. concentrations at 2000 m from initial puddle on water surface below PAC3 (time adjusted PAC3 for NH3 see previous slide). Should be further reduced by a factor of 2, due to account for the irrelevance of the H=0 factor of 2, characterizing Gaussian dispersion. Virtual distance behind the source 4200 m May represent hits at any mountainous elevation.

Outdoor Vs. Indoor Exposures Differences may turn out to be enormous, especially for puff dispersion patterns. See e.g. previous slide See also below, ALOHA output for air concentrations at 1000m from daytime puff release of 1 ton anhydrous ammonia THREAT AT POINT: Concentration Estimates at the point: Downwind: 1000 meters Off Centerline: 0 meters Max Concentration: Outdoor: 152 ppm Indoor: 2.7 ppm