This article is only a small part of the complete Bob Beck Protocol article. Do NOT use without reading the complete Bob Beck Protocol articles first:

Similar documents
Instructions for SOTA Water Ozonator Model WOZ5

INSTruCTIONS FOr SOTa WaTEr O ZONaTOr model WOZ5 CONTENTS INTrOduCTION COmplEmENTary units

Heat Stress Prevention Program

UNOSETION+Bipolar &BIO + Quadrupole &BIO + Quadrupole Vacuum + Sextupolar RF Slimming Machine. Model: YH-5403

4/26/16. Section 1 Understanding Solutions. Solutions and Suspensions. Solutions and Suspensions. Solutions and Suspensions. Solvents and Solutes

Circulation and Respiration: Vital Signs Student Version

The grade 6 English science unit, Gases, meets the academic content standards set in the Korean curriculum, which state students should:

Extending Bubble Trouble In Your Classroom

Does this topic relate to the work the crew is doing? If not, choose another topic.

Oxygen Therapy. Respiratory Rehabilitation Program. What is oxygen?

A breath of fresh air

The Water O 3. zonator. Model WOZ3 Manual CONTENTS

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

Students measure the change in pressure by varying the volume of trapped air in a syringe while:

PLASTICS NEEDING PRE-TREATMENT Page 1 of 5

Chapter 10 First Aid and Field Sanitation

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

LUNA V. User Manual. Warning

Fast or Slow? BROWARD COUNTY ELEMENTARY SCIENCE BENCHMARK PLAN. SC.C The student understands that different things move at different speeds.

On the Go with Oxygen

GRADE 6: Materials 1. UNIT 6M.1 7 hours. Solubility. Resources. About this unit. Previous learning. Expectations. Key vocabulary and technical terms

OUTREACH SPRING QUARTER 2002

DIVING AND SNORKELLING IN SILFRA FISSURE

Heat and Cold Emergencies. Shelley Westwood, RN, BSN

Second Edition Chemistry Experiment Supplies MODULE #1

Vocabulary: Solid has a definite shape and volume.

2008 New York City Marathon Notes

General Chemistry I Percent Yield of Hydrogen Gas From Magnesium and HCl

MOLEBIO LAB #1: Microquantity Measurement

OXYGEN THERAPY. Teaching plan

WALK YOUR WAY TO GREAT SHAPE

Transport in cells. Specification coverage

SAFETY/RISK/HAZARD ASSESSMENT

Unblocking the MicroSprayer Aerosolizer Model IA-1C With the High Pressure Reverse Cleaning Adapter. Instructions for Use

Properties of Gases Observing Atom Pressure of a Gas Measuring Gas Products of Chemical Inferring Molecule Reactions

"HAND, WRIST AND FINGER SAFETY IN CONSTRUCTION ENVIRONMENTS"

Mild steel. Stainless steel. HPR130XD Auto Gas Revision 2. Nozzle retaining cap. tube. Shield cap 30 A 50 A 80 A 130 A

Best Bubbles Teacher Notes

Short Term Planning Science Year 4 Term 1 Topic 4C Keeping warm / Session 1

Oxygen Therapy. What tests can be done to determine the need for oxygen?

INSTALLATION AND OPERATION OF THE HYPERBARIC CHAMBER

Bloodhound SSC Tour & Explore A Circus of Practical Activities explaining the Science behind a 1000mph car.

Talk Science Professional Development

Don t Burst My Bubble!

Cold-acclimatised pipelines

Definitions found in several locations:

BASIC KNOWLEDGE OF LABORATORY FIRST AID

RISKS OF OZONE THERAPY AND HOW TO AVOID THEM

What does the % represent on the beakers?

Standard. Bag & Stand Advanced Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00442

"RESPIRATORY PROTECTION AND SAFETY"

T H E H U M A N B R A I N

OPERATION. Estimated kerf width compensation. HPR260 Manual Gas Instruction Manual 4-9

Lesson: What a Gas! Human Respiration 7 th Grade Life Science November 30 th -31 st. Rationale/Goal:

WHAT TO DO WITH ILL OR DEAD FROGS

States of Matter Preparation Page 1 of 3

Glucose + Oxygen Carbon Dioxide + Water + Energy C6H12O CO2 + 6H20 + energy

Respiration. Figure 22: Schematic representation of the respiratory system

Hyperbaric Oxygen Therapy Patient Information

Introduction. Objectives. Hazards. Procedure

Respiratory Protection

Arterial Puncture Wrist. Instruction Manual

Elementary Science ACTIVITIES

Hockey Scholars: Math and Science Test Study Guide-Answer Key

Test B. Sc Science sampling test KEY STAGE 2. First name. Middle name. Last name. Date of birth. Please circle one. School LEVELS 3 5 *0511SB*

QUICK START GUIDE TO DRINKING WATER MONITORING

Doc. No. SP-14 Rev. No. 1 Date: 07/17/2012 Page 1 of 08

First Aid - immediate care that is given to the victim of an injury or illness until experts can take over - Oftentimes, it s the difference between

Aseptic Vial and Syringe Filling Narlin B. Beaty, Ph.D. Adelaide Nye

Water Samplers, Water Sampling with Internal Recording, Cabling, and Deployment

Introduction IP codes are used in electrical product catalogs, etc., to indicate waterproofness and so on.

Hydrofluoric Acid. Syracuse University Laboratory Standard Operating Procedure. I. Purpose: Physical and Chemical Properties: Potential Hazards:

PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL

The use of risk management as best practice to reduce outbreaks of recreational water illnesses in disinfected swimming facilities and spas

Extension Activities:

RADAR. User Manual EASYCLIK MODEL Vascular. Compression. Device.

Tailgate Safety Training for Landscaping and Horticultural Services

A Patient s Guide to Lateral Epicondylitis (Tennis Elbow) William T. Grant, MD

LIQUID OXYGEN. General. Health Effects. Safety Considerations

THE AMERICAN SAFETY & HEALTH INSTITUTE ADULT CPR EXAM

Project FOCUS Michael Cheng Best Lesson Third Grade

Operating manual Analogue refractometer

The Determination of the Value for Molar Volume

Staying Warm in the Winter

To derive from experiment the relationships between Pressure (P), Volume (V), Temperature (T), and Water Solubility of gases.

X Marks the Blind Spot

Michael Pate Utah State University

BASIS Lesson Plan. *Note to teachers: Detailed standards connections can be found at the end of this lesson plan.

Fox Cities Elite Volleyball Club Player/Parent/Coach. Handbook

Hello. My name is. I m from. I have some very important information to share with you today about a growing problem in our community and around the

limbsandthings.com Advanced Venepuncture Arm User Guide For more skills training products visit Limbs & Things Ltd.

PERSONAL PROTECTIVE EQUIPMENT (PPE) Safe Shops Program Boston Public Health Commission

Gas Exchange ACTIVITY OVERVIEW SUMMARY KEY CONCEPTS AND PROCESS SKILLS KEY VOCABULARY. Teacher s Guide B-75 L A B O R ATO R Y

UNIT 2 Chapter 3. Elodea and Photosynthesis. The Origins of Life. Learning Outcomes: Chapter 3 Lab/Activity #2. Introduction: Safety Issues:

A Liter a Lung Measuring Lung Capacity

ALFRED HYPERBARIC SERVICE. Service and Care. Information for Patients

HEAT INJURIES. MANSCEN Safety Office

Safety Issues in Healthcare Programs / Healthcare Employment

The Development and Implementation of a Protocol to Obtain Voluntary Blood Pressure Readings in an Adult Male Orangutan at Zoo Atlanta

Early Identification of Sick Calves Important to Their Survival and Future Milk Production

Transcription:

Bob Beck Protocol by R. Webster Kehr, Independent Cancer Research Foundation, Inc. Important Note This article is only a small part of the complete Bob Beck Protocol article. Do NOT use without reading the complete Bob Beck Protocol articles first: Article #1: Blood Purifier or Blood Electrification The purpose of the Blood Purifier/Blood Electrification is to attenuate (i.e. disable from multiplying) microbes which flow through the blood. The Blood Purifier creates a small electrical current in the blood which will break off a key enzyme on the surface of all tested microbes. This prevents the microbe from attaching to human cells and multiplying. The microbes are then safely removed from the body. Because of the vast number of microbes which cannot attach to human cells because of this device, it is almost certain that within the first few days of using the Blood Electrification device you will experience "flulike symptoms" (this is called the "Herxheimer Reaction"). These symptoms are caused by the massive die-off of microbes and do not create any type of danger. To prevent this symptom from being severe, it is important to drink copious amounts of water during the Bob Beck Protocol. This water includes the ozonated water. The rule of thumb is to drink half your body weight (measured in pounds) in water (measured in ounces). For example, if your weight is 200 pounds, you would drink 100 ounces of water (1/2 of 200 is 100) per day, maybe more. This includes the ozonated water. Because the Magnetic Pulser is generally used prior to the Blood Electrification treatment, it is important to understand when the water should be taken: 1) One hour before the Magnetic Pulser (for electrolytes to create an electric current), and

2) One-half hour before the Magnetic Pulser (i.e. thirty minutes after the first water) You also might want to drink some water immediately after using the Magnetic Pulser and wait 15 to 30 minutes before starting this Blood Purifier treatment. This water is to detoxify (especially the ozonated water) the blood and lymph system. In other words, the majority of the water you drink during the day should be at one of those three times. All three times are before the Blood Purifier. Most, if not all, of the water you take should be ozonated water. -------------------------------------------------------------------------------- VERY, VERY Important Note - Study Carefully!!!: When placing the electrodes on your ulnar and radial arteries (on your wrist), you should place the electrodes directly on top of the arteries and at the location of strongest pulse. Once you get used to placing the electrodes you will memorize their location and be familiar with the amount of tingling of the electrical current. When putting the electrodes on your wrist, each electrode should be placed inside of a cotton sleeve. The purpose of these cotton sleeves is to protect your skin and to provide better electrical conductivity between the electrodes and the skin. The sleeves need to have salt water dropped on them in order for the electricity to be transferred from the electrodes to the skin.

When keeping these sleeves wet, by putting a few drops of sea salt water on them every 20 to 60 minutes, it is possible that there will be a film of water on the surface of the wrist, and/or on the bottom of the velcrow strap, between the two cotton sleeves. Since electricity always takes the path of least resistance, it is possible the electricity will cross over the thin layer of water on your skin or the bottom of the rubber strap, instead of going through the skin and into the blood stream. You will know this happens because the tingling of the skin, caused by the electrical current, will stop after you put drops of salt water on the cotton sleeves. It is critical to keep the skin between the two cotton sleeves, and the bottom of the velcrow strap, DRY. This is very important to check after each time you wet the cotton sleeves. You can use a Q-Tip, and/or a dry finger and/or blow air between the electrodes, until the area between the cotton sleeves is dry!! When the area between them is dry (including the top of the skin and the bottom of the velcrow strap), the tingling should return. -------------------------------------------------------------------------------- If you think you have large amounts of microbes in your body at the beginning of this treatment, which most people do have, you might want to start using the Blood Purifier for only 20 minutes a day, and build up by 20 minutes a day, until you are using the machine for two hours. You should use the machine for two hours a day for 4 weeks (this does NOT include the days where you use it less than two hours). Likewise, after the four weeks is over, you might want to gradually taper off by 20 minutes a day. Here is a sample protocol: (Two days with none of the forbidden items listed above) Day 1) 20 minutes Day 2) 40 minutes Day 3) 60 minutes

Day 4) 80 minutes Day 5) 100 minutes The 28 consecutive days of the official treatment These are the days when the Magnetic Pulser time is also maximized Days 6-33) 120 minutes every day Day 34) 100 minutes Day 35) 80 minutes Day 36) 60 minutes Day 37) 40 minutes Day 38) 20 minutes At no time during the 38 days of using the equipment (in this example), and the 2 days before you start, are you allowed to take any of the forbidden items. As can be seen, including the build-up and taper-off, this is almost a 6 week treatment. But the benefits of this treatment make it worth the time and effort! During the first half hour, every 5 or 10 minutes you need to turn it up slightly 2 or 3 times during this half hour. In other words, every 5 or 10 minutes you may be able to tolerate a little more tingling. If it is very uncomfortable then back off just a little bit. Some people, perhaps most people, may not be able to tolerate the maximum setting. Just do the best you can without being too uncomfortable. The bottom line is this, you should adjust the Blood Purifier to a "slightly uncomfortable" position. Do not adjust it to an uncomfortable position, just to a "slightly uncomfortable" position. Third, the expert concluded that the method that Bob Beck endorses, using the two arteries on the wrist, was the best location of the electrodes. The reason, he stated, was that electricity will follow the path of least resistance, and by putting both electrodes on the same wrist, you get a much more predictable electrical current in the arteries, from person to person. He stated that while other locations might give the microbes more

exposure to the electrical current, because of the way electrical current will follow the path of least resistance, it is best to have a short distance the current has to flow, in order to better predict the electrical current in a specific artery. For example, in going from ankle to ankle, there are many different paths the electricity can take, including paths that include the muscles and nerves. The total electrical current will be divided up between the different paths, and it will probably turn out that no single path will have the minimum amount of current required by the Kaali and Lyman discovery, which is 50 microamps. In addition, each path has a different length. The greater the length of the path the more resistance. In addition, there are a lot of variables involved in the amount of resistance for each path. The electricity will actually be divided up based on the total resistance of each path (the less resistance the more current will flow in that path). Thus it would be difficult to know how many volts to use for each person to insure at least one artery will have the minimum electrical current. In other words, if a long path is used (such as ankle to ankle), it would be difficult, if not impossible, to guarantee that any single path had enough current because it would be very difficult to measure the current in any given path for a specific person. A meter built into the device would not be able to detect the current in a given artery, for example. Furthermore, all of these variables will vary from person to person. This is why he strongly endorsed putting both electrodes on the same wrist, to minimize the number of variables, even though he was aware of other options. http://cancertutor.com/cancer02/bobbeck-bp.html Back

Bob Beck Protocol by R. Webster Kehr, Independent Cancer Research Foundation, Inc. Important Note This article is only a small part of the complete Bob Beck Protocol article. Article #4: Ozonated Water It has been shown in scientific experiments that there is an inverse relationship between the amount of oxygen in the blood and the ability of cancer to spread. In other words, the more oxygen, the less your disease is able to spread. Ozone is a superb way to get oxygen into your body. However, the amount of ozone in ozonated water is probably not enough to seriously stop the spread of cancer. But it may slow it down and help the other protocols do their job. This treatment is officially a detoxification protocol because it oxidizes toxins and thus prevents many of the serious side-effects of microbe die-off. The liquids which are part of the complete Bob Beck Protocol are either

in the form of distilled water (or a high quality spring water) or ozonated water (which starts out as distilled water). It is the proportion of these two types of liquids which is important to pay attention to. Soda pops (whether diet or sugar soda pop), alcohol, coffee, tea, etc. should not be consumed during the Bob Beck Protocol. But natural, 100% fruit juices can be consumed at any time (with certain exceptions discussed in the main article). One of the simplest and least expensive ways to get ozone (i.e. which breaks down into oxygen singlets and O2) into the bloodstream is to ozonate ice cold, distilled water or a quality spring water (no tap water). The colder the water is, the more ozone the water can hold and the longer it can hold it. Here is a list of the major benefits of ozonated water: 1) It purifies the blood of some microbes, 2) It is a superb detoxification method (it oxidizes the toxins, thus neutralizing them), 3) It may kill some cancer cells or the microbes inside the cells, 4) It can stop the spreading of cancer, 5) It may provide energy, 6) It can help the immune system by providing the white blood cells oxygen singlets. A home-grade water ozonator will cost about $300 (Ours are much less). A medical-grade ozonator, which is not necessary for this treatment, costs $3,000 and up. There are several other things that are necessary to understand. First, the container the distilled water is in, that the ozone will be bubbled into, ABSOLUTELY MUST BE MADE OF GLASS. Ozone will tear apart a plastic container and you will end up drinking plastic!! This eliminates people on feeding tubes from using this part of the treatment unless the feeding tubes are made of silicon. Everything the ozonated water touches should be made of glass, even the drinking glass. Every tube should be made of silicon. Second, the patient should drink the ozonated water as soon as it is made because the ozone only lasts about 20 minutes.

You should turn the ozonator on, with the stone bubbling in the water, for about 6-10 minutes before drinking. Use ONLY a high quality distilled water to make ozonated water, preferably distilled by steam distillation. You cannot use ozonated water when making colloidal silver because if you boil ozonated water (boiling some water is necessary to make colloidal silver), it won't have any ozone left in it. One water is cold (when ozonated water is made) and one water is hot (when colloidal silver is made). Ozonated water does not store well, not even in the refrigerator. If you do store it for a few hours, make sure it is in a glass bottle, has a tight non-metallic, and non-plastic lid, and is put and stays in the refrigerator immediately after making. But even this is not recommended because it order to make a tight lid there must be some type of plastic involved. Because ozonated water, by itself, can create some flu-like symptoms because of die-off, you may want to build up with this product (there is no need to taper off). As mentioned in the main article, the minimum amount of liquids (e.g. water or ozonated water) you should consume is one ounce per two pounds of body weight (e.g. 200 pounds means 100 ounces). To build up to the amount of ozonated water, you could start with 10% of your total liquid intake coming from ozonated water and 90% from distilled water. In other words, your total daily intake of liquids will be the same every day, but for the first day, for example, only 10% of your total daily intake is ozonated water. The second day only 20% of your total daily intake is ozonated water. Or whatever buildup you wish to use. You should build up to 100% ozonated water as the liquid part of the Bob Beck Protocol. Lung cancer patients, emphysema patients and asthma patients (and anyone else with lung congestion) should NOT use/inhale the water ozonator at all. The reason is that ozone gas is released during the process of bubbling and ozone gas may cause congestion or make existing congestion much worse. However, these patients should drink the required amount of liquids as distilled or a quality

spring water. http://cancertutor.com/cancer02/bobbeck-oz.html Home