Reference Material Institute for Clinical Chemistry Standards (ReCCS) JCCRM 621-4

Similar documents
Q U A L I T Y C O N T R O L F o r u s e w i t h t h e R N A M e d i c a l, I n c. QC 823 Blood Gas/Electrolyte Controls

TECHNICAL BULLETIN. TriControls. Control Materials for Liquid QC and Calibration Verification

Technical Procedure for General Laboratory Equipment

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

CALIBRATION CERTIFICATE # 500

TEXAS DEPARTMENT OF PUBLIC SAFETY Breath Alcohol Laboratory

Gas mixtures. Individual solutions specifically for your application

20. Technical Equipment. Archived. This section applies to all equipment used in forensic examinations, such as

CORESTA RECOMMENDED METHOD N 6

How and why Eurotrol s CueSee Hypoxic works

Certified Reference Materials FOR REFRACTOMETERS AND POLARIMETERS

ali-q TM Gravimetric Verification Procedure

Blood Parameter Monitoring System 550

Measuring the Conductivity of Pure Water Using USP<645>

EN ISO/IEC Technical Requirements

RESPIRATORY REGULATION DURING EXERCISE

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

Assessing the ABL 500 blood gas analyser

EMERGENCY MEDICINE AND THE LABORATORY. Ehsan Bolvardi(MD)

VIC offers a variety of Calibrated Gas Leaks

Topics For Discussion Acadiana Gas Measurement School

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Respiratory System Physiology. Dr. Vedat Evren

(NIST Special Publication )

Protocol Gas Verification Program (PGVP)

Calibration Procedure

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

Date of Shipment: Xxxxx 00, 20xx 3402c National Institute of Advanced Industrial Science and Technology National Metrology Institute of

Respiratory physiology II.

AQ-C 2016 Kit Instructions CAP 2016

CALIBRATION SYSTEM REQUIREMENTS. ESCC Basic Specification No

Protocol Gas Verification For Compressed Gas Cylinders Containing Either SO 2, NO or CO. Quality Assurance Plan/Standard Operating Procedure

Oxygen and Carbon dioxide Transport. Dr. Laila Al-Dokhi

VISCOMETER, OFI, 8-SPEED, MODEL 800 PART No

HCO - 3 H 2 CO 3 CO 2 + H H H + Breathing rate is regulated by blood ph and C02. CO2 and Bicarbonate act as a ph Buffer in the blood

Requirements and Methods for Calibration of Equipment in Clinical Laboratories. NK Chan (HKRCBTS) 24 August 2007

QAM-I-117 Volumetric Equipment Calibration Verification

International Civil Aviation Organization DANGEROUS GOODS PANEL (DGP) MEETING OF THE WORKING GROUP OF THE WHOLE. Montreal, 18 to 22 April 2005

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

Relative Humidity Calibration Kit

Generating Calibration Gas Standards

HemoCue Hb Procedure Template

STERILIZABLE DISSOLVED OXYGEN SENSORS

Respiratory Lecture Test Questions Set 3

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

Section Two Diffusion of gases

Operator s Manual AVL COMPACT 3

BLOOD GAS (ARTERIAL AND VENOUS

Chapter 17 The Respiratory System: Gas Exchange and Regulation of Breathing

Monosed ESR Non-Vacuum Tube USER S MANUAL

Stat Profile Prime Critical Care Analyser

Preanalytical issues related to blood sample mixing

Oxidation Stability of Gasoline and Aviation Fuels

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

DISSOLUTION TEST FOR SOLID DOSAGE FORMS

Water Testing Technologies: Stepping Into the 21 st Century Ivars Jaunakais

Svensk läkemedelsstandard

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

Point-of-Care Testing: A Cardiovascular Perfusionist s Perspective

CDI Blood Parameter Monitoring System 500 A New Tool for the Clinical Perfusionist

1. Scope: This document describes the procedure for verifying the performance of vaccine vial monitors.

Inspection and Acceptance of Asphalt Mix Design Laboratories

Gas Mixture Two Components. Gas Mixtures Two Components

Mass Flowmeters. Mass Flowmeters for Gases

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No..

Radnoti Liver Perfusion System

The Gold Standard in Calibration Mixtures

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

711 DISSOLUTION. Portions of the present general chapter text that are national USP text, and therefore not part of the

Essential Skills Course Acute Care Module. Respiratory Day 2 (Arterial Blood Gases) Pre course Workbook

CspB ELISA Kit DAS ELISA for the detection of CspB protein Catalog number: PSP 35500

CalCheck. Instrument User Manual V1.8

Improve Process Reliability

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

TECHNICAL NOTE. October 23, Procedures for Verifying Temperature Calibration

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

Breath Alcohol Calibration Test No Summary Report

2014 Programme of Training Courses in Measurement & Calibration

Technical Report. 5th Round Robin Test for Multi-Capillary Ventilation Calibration Standards (2016/2017)

Section Three Gas transport

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

VITLAB micropipette. Standard Operating Procedure (SOP)

SS32L Dissolved O 2 Probe

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

- How do the carotid bodies sense arterial blood gases? o The carotid bodies weigh 25mg, yet they have their own artery. This means that they have

Finding Leak Testing Success Through Calibration and Validation. Paul Chamberlain President, CEO

General Accreditation Criteria Reference Material Producers. ISO Standard Application Document

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

Preanalytical Considerations in Blood Gas Analysis Total Quality Issues for the Clinical Laboratory

Certificate of Accreditation

ISO 7218 INTERNATIONAL STANDARD

Calibration Procedure. PosiTest DFT Combo

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation

ISO/TR TECHNICAL REPORT. Natural gas Calibration of chilled mirror type instruments for hydrocarbon dewpoint (liquid formation)

ISO Vacuum gauges Calibration by direct comparison with a reference gauge

Douglas S. Lançon/ Ben N. Vetter Breath Alcohol/Toxicology Montana DOJ-FSD Laboratory

Gases and Respiration. Respiration Overview I

Transcription:

Certified Reference Material for Blood Gases JCCRM 621-4 Handling Instructions Properties and Intended Use This Certified Reference Material (CRM) for Blood Gases is intended for use in verifying the accuracy of blood gas (ph, pco2, po2) analysers in clinical testing. It is prepared from bovine hemoglobin. The differences in the oxygen buffering capacities between human whole blood and bovine hemoglobin have been corrected by the mean differences between these two detected by almost all po2 2 instruments. Therefore using the certified values, you can obtain virtually the same values as you would with human whole blood. Note: This CRM cannot be used for blood gas analysers not capable of measuring hemolysate. Instruction for Use This CRM is supplied in an air-tight glass ampoule. Measurements of this material must be taken after completely equilibrating gases in the ampoule at 37 C (or at 30 C). Set the water bath temperature at 37 C (or 30 C) and follow ow the instructions below. Constant Temperature Water Bath 37 C ± 0.5 C (or 30 C ± 0.5 C) ) Place ampoule in water bath and let stand for about 15 minutes Position the ampoule on its side and shake it horizontally (about 30 times / 10 seconds) Return ampoule to water bath and stir it in circular motion for about 10 seconds. Let stand for about 1 minute Repeat step Repeat step finger tip to allow Tap ampoule with content to collect at the bottom. Open ampoule and take measurement within 30 seconds of opening. 1

Caution This CRM is supplied in a glass ampoule. Applying excessive force to the ampoule can result in breaking the ampoule. Exercise careful caution and wear protective gloves to avoid severe injury in case of breakage. Although this CRM is prepared from hemoglobin of inspected healthy animals which passed quarantine inspections, exercise caution by treating as if it were human blood and infection. In-Vitro Use Only Storage Temperature and Expiration Date This CRM is shipped frozen (packed with dry ice). Store the product in a deep freezer or a refrigerator upon receipt. Shelf life is shown below according to the specified storage temperatures. (Ship date is indicated on the product label.) Frozen ( 70 C ~ 90 C): 9 months after the ship date. Refrigerated (+2 C ~ +10 C): 4 days after placing it in a refrigerator. Specifications Items Measured: ph, pco2, po2 Content: 3 levels, 2 ampoules for each level (1.5 ml / ampoule), total of 6 ampoules 2

Certified Reference Material for Blood Gas JCCRM 621-4 Certificate of Analysis Certified Values and Expanded Uncertainties Certified values and expanded uncertainties for this Certified Reference Material for Blood Gas (JCCRM 621-4) are shown below. The certified values for ph, pco2, po2 differ depending on the gas equilibration ibra temperature. Use the certified values with the gas equilibration temperature of 37 C or 30 C. Table 1 Gas equilibration temperature for the reference material: 37 C Measured temperature: erat 37 C Certified values & Expanded uncertainties Item Level 1 Level 2 Level 3 Unit of measure ph 7.339 ± 0.022 7.445 ± 0.023 7.546 ± 0.022 - pco2 54.5 ± 1.3 38.5± 1.4 27.3± 1.1 mmhg po2 40.6 ± 1.4 61.7± 2.0 81.4± 3.0 mmhg Differences in the oxygen buffering capacities of human blood od and the bovine hemoglobin liquid by the mean values of the differences detected by various measuring electrodes are corrected rec (The mean values for correction obtained using 7 blood gas analysers were 0.5 (0.2 ~ 0.8), 0.7 (0.4~1.0), and 1.0 (0.7 ~ 1.3) mmhg for each respective levels, 1, 2, and 3). Table 2 Gas equilibration temperature for the reference material: 37 C Measured temperature: 37 C Certified values & Expanded uncertainties Item Level 1 Level 2 Level 3 Unit of measure ph 7.299 ± 0.023 7.414 ± 0.024 7.526 ± 0.023 - pco2 61.3 ± 1.9 41.9 ± 1.7 29.4 ± 1.2 mmhg po2 47.0 ± 1.1 79.3 ± 2.7 105.1 ± 2.5 mmhg Differences in the oxygen buffering capacities of human blood and the bovine hemoglobin liquid by the mean values of the differences detected by various measuring electrodes are corrected (The mean values for correction obtained using 7 blood gas analysers were 0.5 (0.2 ~ 0.8), 1.0(0.7~ 1.3), and 2.0 (1.5 ~ 2.5) mmhg for each respective levels, 1, 2, and 3). 3

The uncertainties shown in Table 1 and Table 2 are expressed as expanded uncertainties (U, 95% confidence level) estimated according to ISO GUM: Guide to the Expression of Uncertainty in Measurement. REFERENCE [4]. U were calculated by U = k x Uc, where Uc is the combined standard uncertainty, and k is the coverage factor (k = 2.0). Here, Uc represents combined standard uncertainty derived from measurements, homogeneity gas equilibration process, and between ampoule variation, stability during storage, and correction to whole blood. Note: Please refer to the ADDENDUM on page 4 for the maximum allowable limits of bias from certified values for routine blood gas analysers. Measurement Method Used for the Certified Values The certified values of ph were assayed using a ph electrode with a reference cell. This is the standard reference method prescribed by the IFCC (REFERENCE [2]). The certified values of pco2 and po2 were measured using a standard blood gas analyzer calibrated by the standard tonometry method according to the IFCC s reference method procedure (REFERENCE ERE [3]). Measurements were protormed at the. Preparation Hemoglobin obtained by hemolysis s of washed bovine red cells was sealed in an air-tight ampoule after stabilizing its partial gas pressure. Its ionic strength, bicarbonate concentration, BE (Base Excess), and total hemoglobin level were adjusted as to meet the specifications of this CRM (REFERECE [1]). Traceability abi y As a reference rence material for measuring the certified values of ph, we used a ph standard solution (ph 6.8408 ± 0.010 at 37 C, ph 7.3940 ± 0.010 at 37 C) prepared from the NIST Standard Reference Materials (SRM 186-I-g, KH2PO4; SRM 186-II-g, Na2HPO4). For the tonometry of pco2 and po2, we used 3 levels of primary standard gases (CO2 + O2, balance N2) certified by the accreditation body of JCSS (Japan Calibration Service System). We also used a platinum resistance reference thermometer calibrated by JCSS for standard tonometry and gas equilibration. Date of Certification July 27, 2016 4

ADDENDUM po2 difference between human whole blood and bovine hemoglobin. We used 7 different blood gas analysers from 3 different manufacturers (A ~ G). Human whole blood and bovine Hb liquid were tonometered using the same standard gases. These samples were measured and evaluated to determine the effect of the different oxygen buffering capacities on the po2 measuring electrodes. The charts below show the different po2 values from the 2 different tonometry gases. The results indicated that the differences between human whole blood and bovine Hb were 0.3 ~ 0.8 mmhg and 0.5 ~ 2.4 mmhg for the theoretical po2 values of 37 mmhg and 72 mmhg, respectively. Biases range from the certified values of routine blood gas analysers. Table 3 Bias test results (see Reference [1]) pco2 (mmhg) po2 (mmhg) ph 30 30 ~ 50 50 40 40 ~ 100 100 ± 0.04 ± 2.0 ± 3.0 ± 4.0 ± 3.0 ± 5.0 ± 6.0 Properties Properties of this CRM are shown in the table below. The values were obtained by measuring the level 2 of this CRM using a routine test method to verify that they meet the specifications for the reference materials (Reference [1]). 5

Table 4 Properties of JCCRM 621-4 Item Standards Reference Value Unit of Measure Method Used Ion Strength 160 ± 20 151 mmol/kg Calculated from electrolytic concentration Base Excess 0 ± 4 1 mmol/l Nomogram Total Hb Level 140 ± 20 140 g/l ICSH method (cyanmethemoglobin method) MetHb Content Ratio 6 0.6 % Absorptiometry REFERENCES [1] Committee on Blood Gases and Electrolytes, Japan Society of Clinical Chemistry. Approved Recommendation on JSCC Methods on the Preparation atio of Working Reference Material and Evaluation and Calibration for the Determination of the Blood Gas Measurement, Clinical Chemistry, 34, 148-159 (2005) [2] Approved IFCC methods. Reference method (1986) for ph measurement in blood. Clin Chim Acta 165:97-109 (1987) [3] IFCC Method (1988) for tonometry of blood: Reference materials for PCO2 and PO2. J Clin Chem Clin Biochem 27:403-408 (1989) 9) [4] Guide to the Expression of Uncertainty in Measurement, ISBN 92-67-10188-9, 1 st Ed. ISO, Geneva, Switzerland (1995) Provider of JCCRM 621-4: Hirohito Umemoto, President http://www.reccs.or.jp/ 1-3-3 Azaminominami, Aoba-ku, Yokohama 225-0012, Japan Tel (general inquiry and orders): 81-44-850-3140 Fax: 81-44-850-3141 Tel (technical inquiry): 81-45-507-6145 Fax: 81-45-530-9036 *No part of this Certificate of Analysis shall be reproduced without prior approval. 6