UCA-UVO-UCB. SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 pole - 50 Hz OPERATING LIMITS APPLICATIONS CHARACTERISTICS ADVANTAGES

Similar documents
50Hz. water solutions. O SerieS DGO DRO

Submersible Electric Pumps for drainage of clean and slightly dirty water DIWA Series

APPLICATIONS. Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors.

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Pressure switch KP-E. Data sheet

Liquid ring vacuum pumps single-stage

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302

Etanorm V Type Series Booklet

Submersible Pumps Product Overview

On-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor.

KSB Delta Compact Type Series Booklet

Deep Well Submersible Pump Model MSU/MSUS

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD.

RP series Rotor Pumps

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Liquid ring compressor

Expert Hydrostatic Level Transmitters

NAUTILUS Small pump. Powerful performance. Certified according to DIN 14425, submersible pumps for fire departments

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Lowara 1300 Series: Pure performance SUBMERSIBILE PUMP RANGE (MENA REGION)

KSB Delta Compact Type Series Booklet

STAINLESS STEEL GRAND SERIES

Pressure controls for hydro carbons, zone II applications, Type KPE

CAST IRON SAFETY VALVE TYPE 6301

SIHI LPH-X - Liquid Ring Compressors

TECHNICAL DESCRIPTION

BOSS PULISCI PROVA IMPIANTI MEDIA

Liquid ring compressors

Pressure switches for air and water CS

Installation, Operation & Maintenance Instructions

DEEP WELL SUBMERSIBLE PUMPS. An ISO 9001 & Company

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

NEW TYPE M PRESSURE RELIEF DEVICE

Hot Water Stationary Unit

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

T Y P E V S A B M S E W A G E P U M P

400V 50Hz. Tsurumi TRN. Submersible aerator. Auto-suction submersible aerator for communal and industrial waste water clearance and treatment.

EnerVal. Technical data litre storage capacity. Buffer storage vessels

CNG FILLING STATIONS

RW series. Clogless impeller-fitted centrifugal pumps

Pressure Relief Valves. SPV, SPVF direct operated

LMU100/200 Series. Standard Specifications

Monitoring device NTS 30

Liquid ring vacuum pumps in compact design

60HZ XIANDAI PUMP. CDL/CDLF Vertical Multistage Pump ZHEJIANG XIANDAI PUMP CO.,LTD. ZHEJIANG XIANDAI PUMP CO.,LTD.

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Pocket Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Liquid ring vacuum pumps in compact design

icon i150 / i350 Installation / Operation Manual

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

GENO -Flushing Compressor Product Data Sheet F 02

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet

4/2 way Pneumatic Solenoid Valve

Remotely-installed Hydraulic Module

Aquavar SOLO 2 Frequently Asked Questions

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

Pressure control, differental pressure control and thermostat Type RT

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

ELECTRIC ACTUATORS for continuous underwater use

HYDRAULICS. H89.8D - Hydraulic Bench

Liquid ring vacuum pumps in compact design

ELRO IP/ XP Peristaltic Pumps

Level switches Series LD Vibrating fork level switch for liquids and solids

Pressure transmitters EMP 2

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

KIT. Small Automatic Water Boosters KIT MODELS

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Electromechanical pressure switches

EX-RECESSED CEILING LIGHT FITTINGS

200 PSI COMPRESSORS - MODEL NUMBERS

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

100C Air Compressor Kit

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

IMPORTANT SAFETY INSTRUCTIONS

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Axial piston pumps type PVC

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

3-Way Safety Block DSV

Axial piston pumps type PVC

Nikuni KTM Series Pumps

INSTALLATION, OPERATING AND MAINTENANCE MANUAL Submersible Ballast Pump MANUFACTURED BY

Installation and commissioning instructions 255 series and 256 series

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

444C DUAL PERFORMANCE VALUE PACK

Fixed Displacement Motor A4FM

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

ALF400 to 900, ALT-5/-9

Introduction to Pumps

Pressure switch, Differential pressure switch and Thermostat RT-E

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Remeha Quinta Cascade guide

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level.

Nikuni KTM Series Pumps

PRODUCTS CATALOGUE 2017 / Torino - Strada Settimo 388/15 Tel (+39) /43 Fax (+39)

Transcription:

OPERATING LIMITS Flow rates up to: 24 m 3 /h Head up to: 62 m Maximum immersion depth: 12.5 m Max. particle size: Ø 5 to 8* ND discharge port: 8/1 mm IP : 68 *depending on model SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 pole - 5 Hz APPLICATIONS 62 51 Hm 17 UCA-UVO ND8 UCA-UCB ND1 Pumps intended for sewerage lift and discharge stations, intermittent operation. Lifting of: waste water, excess water, muddy water, industrial water. Drainage of: septic tanks, drains. Qm 3 /h 1 12 2 237 CHARACTERISTICS - Several impeller types: VORTEX, single-channel, two-channel. - The submerged motor cable inlet is protected 3 times against the infiltration of fluid. - Mechanical seal on the fluid side. - The UCB pumps are fitted with a block seal. ADVANTAGES - Several particle sizes: 5/7/8, several types of use depending on the type of impeller. - No risk of infiltration into the submerged motor chamber. - Completely leaktight motor part. - The cassette seal ensures reliable sealing: no bellows and no ageing through natural or chemical agents. UCA-UVO 28 1 N.T. N 145-12/ENG. - Ed.2/5-5

DESIGN Hydraulic part - Submersible, vertical shaft. - Shaft common to pump and motor Oil-filled. - Interstage chamber between pump and motor, insulated by a lip seal and mechanical seals: - Double mechanical block seal for UCB pumps. - Three impeller types: single-channel, twochannel or vortex impeller. Motor - Leaktight with dry rotor. - Built-in thermal probe protecting the motor against overheating. - Direct starting up to 4 kw; Star-delta starting over 4 kw. - Speed: 145 and 29 rpm -Winding: ~3 ; 4 V -Frequency: 5 HZ - Insulation class: F -Protection index: IP 68 -CE HYDRAULIC PERFORMANCES Imp.gpm 6 Hm 5 4 3 2 1 1 2 3 4 5 ND8 3~4V,5Hz UCA-UVO 28 N UCA 28-12 /3.7 T4 1 UCA 28-13 /3.7 T4 2 UCA 28-13 /5. T4 3 UCA 28-15 /5. T4 4 UVO 28-16 /1.5 T4 5 UVO 28-16 /15.5 T4 6 UVO 28-17 /15.5 T4 7 UVO 28-19 /15.5 T4 8 UVO 28-21 /15.5 T4 9 Qm 3 /h 2 4 6 8 1 12 14 Ql/min 3 6 9 12 15 18 21 Ql/s 1 2 3 Hft 15 1 1 14 Options : ATEX (on certain models) 8 Hm 7 Imp.gpm 2 4 6 8 1 UCA-UCB ND1 3~4V,5Hz Hft IDENTIFICATION 6 5 4 15 14 UCA-UCB 41 UCA 41-23/6.5T4 1 UCA 41-26/1T4 11 UCA 41-28/1.T4 12 UCB 41-33/25.T4 13 UCA 41-37/25.T4 14 UCA 41-41/34.T4 15 U CA 2 8 12/3,7 T4 CB 4 VO T4: 4 V three-phase P2 in kw Impeller diameter in cm Discharge diameter in cm number of poles CA: single-channel impeller CB: two-channel impeller VO: Vortex impeller Range code 3 2 1 Qm 3 /h 13 12 11 1 4 8 12 16 2 24 28 Ql/min 6 12 18 24 3 36 42 Ql/s 2 4 6 STANDARD CONSTRUCTION Model UCA 28 UVO 28 UCA 41 UCB 41 Pump body EN-GJL 2 EN-GJL 25 EN-GJS 5-7 Impeller GGG 5 (.75) EN-GJL 2 (GG2 -.62) EN-GJL 25 EN-GJS 5-7 Shaft AISI-42 AISI-42 Mechanical seal SiC / SiC SiC / SiC Sealing on motor side NBR NBR SiC / SiC Motor frame EN-GJL 2 EN-GJL 2 EN-GJL 25 2

DIMENSIONS UCA-UVO 28 fixed installation ND 8 mobile installation ND 8 UCA-UVO 28 A B C D E F G H1 H2 I J K L M N O P Q R UCA28-12/3.7 T4 2 16 18 166 59 9 539 58 585 119 124 344 21 3 15 12 17 264 229 UCA28-13/3.7 T4 2 16 18 166 59 9 539 58 585 119 124 344 21 3 15 12 17 264 229 UCA28-13/5. T4 2 16 18 166 59 9 594 635 64 119 124 344 21 3 15 12 17 264 229 UCA28-15/5. T4 2 16 18 166 59 9 593 635 64 119 124 344 21 3 15 12 17 264 229 UVO28-16/1.5 T4 2 16 18 166 59 9 753 79 85 11 124 344 21 3 15 12 17 374 34 UVO28-16/15.5 T4 2 16 18 166 59 9 875 91 925 11 124 344 21 3 15 12 17 374 34 UVO28-17/15.5 T4 2 16 18 166 59 9 875 91 925 11 124 344 21 3 15 12 17 374 34 UVO28-19/15.5 T4 2 16 18 166 59 9 832 88 88 125 124 344 21 3 15 12 17 45 35 UVO28-21/15.5 T4 2 16 18 166 59 9 832 88 88 125 124 344 21 3 15 12 17 45 35 TECHNICAL DATA curve Submerged Dry sump Operation P1 P2 I Speed Mains IP Cable Weight Particle Starting nr installation installation (kw) (kw) (A) (rpm) voltage (m) (kg) size UCA 28-12 /3.7 T4 1 + S2-15 S1 4.75 3.75 7.6 29 3~4V, 5Hz 68 15 55 7 direct UCA 28-13 /3.7 T4 2 + S2-15 S1 4.75 3.75 7.6 29 3~4V, 5Hz 68 15 55 7 direct UCA 28-13 /5. T4 3 + S2-15 S1 6 5 9.7 29 3~4V, 5Hz 68 15 59 7 Y - UCA 28-15 /5. T4 4 + - S1 6 5 9.7 29 3~4V, 5Hz 68 15 59 7 Y - UVO 28-16 /1.5 T4 5 + - S1 12.3 1.5 2.5 29 3~4V, 5Hz 68 15 119 8 Y - UVO 28-16 /15.5 T4 6 + - S1 18.6 15.5 3.5 29 3~4V, 5Hz 68 15 163 8 Y - UVO 28-17 /15.5 T4 7 + - S1 18.6 15.5 3.5 29 3~4V, 5Hz 68 15 163 8 Y - UVO 28-19 /15.5 T4 8 + - S1 18.6 15.5 3.5 29 3~4V, 5Hz 68 15 162 5 Y - UVO 28-21 /15.5 T4 9 + - S1 18.6 15.5 3.5 29 3~4V, 5Hz 68 15 162 5 Y - 3

DIMENSIONS UCA-UVO 41 fixed installation ND 1 mobile installation ND 1 UCA-UVO 41 A B C D E F G H1 H2 I J K L M N O P Q R DN UCA41-23/6.5 T4 22 18 18 176 65 9 664 71 715 12 124 32 225 325 15 16 19 448 394 32 UCA41-26/1. T4 22 18 18 176 65 9 744 67 795 12 124 32 225 325 15 16 19 448 394 32 UCA41-28/1. T4 22 18 18 176 65 9 744 67 795 12 124 32 225 325 15 16 19 448 394 32 UCB41-33/25. T4 285 24 22 241 19 12 116 116 1155 183 18 5 32 54 Special base elbow 635 563 5 UCB41-37/25. T4 285 24 22 241 19 12 116 116 1155 183 18 5 32 54 set for UCB 41 635 563 5 UCB41-41/34. T4 285 24 22 241 19 12 123 123 1225 183 18 5 32 54 622587 635 563 5 TECHNICAL DATA curve Submerged Dry sump Operation P1 P2 I Speed Mains IP Cable Weight Particle Starting nr installation installation (kw) (kw) (A) (rpm) voltage (m) (kg) size UCA 41-23/6.5T4 1 + - S1 8.1 6.5 13.5 145 3~4V, 5Hz 68 15 16 8 Y - UCA 41-26/1T4 11 + - S1 12.3 1 21 145 3~4V, 5Hz 68 15 137 8 Y - UCA 41-28/1.T4 12 + - S1 12.3 1 21 145 3~4V, 5Hz 68 15 139 8 Y - UCB 41-33/25.T4 13 + - S1 28.5 25 49.5 145 3~4V, 5Hz 68 15 361 8 Y - UCA 41-37/25.T4 14 + - S1 28.5 25 49.5 145 3~4V, 5Hz 68 15 376 8 Y - UCA 41-41/34.T4 15 + - S1 38.7 34 68 145 3~4V, 5Hz 68 15 415 8 Y - 4

P 1 P 2 MEMO RESET AUTO ACCESSORIES RECOMMENDED FOR ATEX INSTALLATIONS Yn 5 9 1-Gate valves Gate valve ND 8 217162 Gate valve ND 1 217163 295 18 1 2 5 2-Check valve Ball check valve ND 8 415761 Ball check valve ND 1 415762 24 245 13 6 11 7 15A 4 15B 4, 5 and 14 - Electronic air pressure switch IPAE with 1 m cable 2519921 IPAE with 3 m cable 2519922 IPAE with 5 m cable 2519923 Cable hook for an IPAE (5) 2519927 Zener barrier (14) 2521216 26 1 1: Gate valve 2: Ball check valve 4: IPAE air pressure switch 5: Cable hook for an IPAE 6: ND 32 guide bars (ND 5 for UCB 41s) 7: Lifting chain 9: Control box for ATEX installations unit to be placed out of hazardous area 1 : Base elbow set 11 : Cable (15m) 13 : Bleed hole to be created 14 : Zener barrier for an ATEX installation Reminder: ATEX pumps are optional. 7-Chain 5 m, 6 mm thick 622588 1 m, 6 mm thick 622589 5 m, 8 mm thick (for UCB) 62259 1m, 8 mm thick (for UCB) 622582 9-Control boxes 1 pump installation 2 pump installation Control box Reference Control box Reference UCA 28-12 /3.7 T4 YN511E 2521217 YN521E 2521218 UCA 28-13 /3.7 T4 YN511E 2521217 YN521E 2521218 UCA 28-13 /5. T4 YN511E 2521217 YN521E 2521218 UCA 28-15 /5. T4 YN511E 2521217 YN521E 2521218 UVO 28-16 /1.5 T4 YN512E 2521225 YN522E 2521226 UVO 28-16 /15.5 T4 YN5132E 2521227 YN5232E 2521228 UVO 28-17 /15.5 T4 YN5132E 2521227 YN5232E 2521228 UVO 28-19 /15.5 T4 YN5132E 2521227 YN5232E 2521228 UVO 28-21 /15.5 T4 YN5132E 2521227 YN5232E 2521228 UCA 41-23/6.5T4 YN5116E 2512223 YN5216E 2521224 UCA 41-26/1T4 YN512E 2521225 YN522E 2521226 UCA 41-28/1.T4 YN512E 2521225 YN522E 2521226 UCB 41-33/25.T4 YN5155E 2521231 YN5255E 2521232 UCA 41-37/25.T4 YN5155E 2521231 YN5255E 2521232 UCA 41-41/34.T4 YN5171E 2521233 YN5271E 2521234 I + - Yn 5E 1 - Base elbow set Base elbow set ND 8, 2 bar ND 32 622585 Base elbow set ND 1, 2 bar ND 32 622587 (for UCA 41) Base elbow set ND 1, 2 bar ND 5 622591 (for UCB 41) 5

P 1 P 2 MEMO RESET AUTO ACCESSORIES RECOMMENDED FOR FIXED INSTALLATIONS Yn 5 9 1-Gate valves Gate valve ND 8 217162 Gate valve ND 1 217163 295 18 1 2 5 2-Check valve Ball check valve ND 8 415761 Ball check valve ND 1 415762 24 245 13 6 11 26 7 3 3-Float switches Nivo 43X1-1M ECOLO 427319 Nivo 43X1-2M ECOLO 42732 Raceway wall bracket 413188 1 1: Gate valve 2: Ball check valve 3: Float switches 5: Cable look 6: Guide bars ND 32 (ND 5 for UCB 41s) 7: Lifting chain 8: Control box YN 4 or YN 5E 1 : Base elbow set 11 : Cable (15m) 13 : Bleed hole to be created 7-Chain 5 m, 6 mm thick 622588 1 m, 6mm thick 622589 5 m, 8 mm thick (for UCB) 62259 1 m, 8 mm thick (for UCB) 622582 8-Control boxes 1 pump installation 2 pump installation Control box Reference Control box Reference UCA 28-12 /3.7 T4 YN4112 43582 YN4212 435884 UCA 28-13 /3.7 T4 YN4112 43582 YN4212 435884 UCA 28-13 /5. T4 YN4112 43582 YN4212 435884 UCA 28-15 /5. T4 YN4112 43582 YN4212 435884 UVO 28-16 /1.5 T4 YN512E 2521225 YN522E 2521226 UVO 28-16 /15.5 T4 YN5132E 2521227 YN5232E 2521228 UVO 28-17 /15.5 T4 YN5132E 2521227 YN5232E 2521228 UVO 28-19 /15.5 T4 YN5132E 2521227 YN5232E 2521228 UVO 28-21 /15.5 T4 YN5132E 2521227 YN5232E 2521228 UCA 41-23/6.5T4 YN5116E 2512223 YN5216E 2521224 UCA 41-26/1T4 YN512E 2521225 YN522E 2521226 UCA 41-28/1.T4 YN512E 2521225 YN522E 2521226 UCB 41-33/25.T4 YN5155E 2521231 YN5255E 2521232 UCA 41-37/25.T4 YN5155E 2521231 YN5255E 2521232 UCA 41-41/34.T4 YN5171E 2521233 YN5271E 2521234 I + - Yn 5E 1 - Base elbow set Base elbow set ND 8, 2 bar ND 32 622585 Base elbow set ND 1, 2 bar ND 32 622587 (for UCA 41) Base elbow set for UCB 41, 2 bar ND 5 622591 6

P 1 P 2 MEMO RESET AUTO ACCESSORIES RECOMMENDED FOR MOBILE INSTALLATIONS 1- Pedestal Mobile installation pedestal ND 8 622586 Mobile installation pedestal ND 8/1 (for UCA-UVO 28 Hmax >44m and UCA 41) 622592 Mobile installation pedestal ND 1 (for UCB) 622593 14 1 124 24 2-Elbow Right elbow ND 8 217698 Right elbow ND 1 215597 3 and 4 - Quick coupling 3) ND 8 18275 4) ND 8 18269 3) ND 1 19792 4) ND 1 18276 3 4 1: Mobile installation mounting 2: Right elbow 3 & 4 : Quick coupling 5: Flexible pipe 6: Lifting chain 5-Flexible pipe Flexible pipe 1m ND8 217691 Flexible pipe 2m ND8 217692 Flexible pipe 3m ND8 217693 Flexible pipe 1m ND1 215585 Flexible pipe 2m ND1 215586 Flexible pipe 3m ND1 215587 6-Chain 5m, 6 mm thick 622588 1m, 6 mm thick 622589 5m, 8 mm thick (for UCB) 62259 1m, 8 mm thick (for UCB) 622582 7-Control box 1 pump installation 2 pump installation Control box Reference Control box Reference UCA 28-12 /3.7 T4 YN4112 43582 YN4212 435884 UCA 28-13 /3.7 T4 YN4112 43582 YN4212 435884 UCA 28-13 /5. T4 YN4112 43582 YN4212 435884 UCA 28-15 /5. T4 YN4112 43582 YN4212 435884 UVO 28-16 /1.5 T4 YN512E 2521225 YN522E 2521226 UVO 28-16 /15.5 T4 YN5132E 2521227 YN5232E 2521228 UVO 28-17 /15.5 T4 YN5132E 2521227 YN5232E 2521228 UVO 28-19 /15.5 T4 YN5132E 2521227 YN5232E 2521228 UVO 28-21 /15.5 T4 YN5132E 2521227 YN5232E 2521228 UCA 41-23/6.5T4 YN5116E 2512223 YN5216E 2521224 UCA 41-26/1T4 YN512E 2521225 YN522E 2521226 UCA 41-28/1.T4 YN512E 2521225 YN522E 2521226 UCB 41-33/25.T4 YN5155E 2521231 YN5255E 2521232 UCA 41-37/25.T4 YN5155E 2521231 YN5255E 2521232 UCA 41-41/34.T4 YN5171E 2521233 YN5271E 2521234 I + - Yn 5E 7

FEATURES a) Electrical - Three-phase 4V, 5 Hz, direct-on-line starting on model 28-14/4. - Three-phase 4V, 5 Hz, Y starting on models 28-17/9 and 28-19/19. Mandatory thermal protection against overcurrents via discontactor, circuit breaker or control unit with level regulator. b) Installation - Pump in vertical position, for fixed or mobile installation. - Mobile installation: the discharge port will be connected with an elbow to flexible piping with larger diameter than the pump discharge. - Dual installation: the pumps may be twinned by collector. - Check valves and valves to be installed, preferably in the upper section of the discharge duct. - Connection with flexible or rigid piping. c) Packaging Pump supplied on a pallet Pump supplied with electric cables H7RN-F for UCAs or NSSHOJ-S for UVO/UCB. Accessories packaged separately. RECOMMENDED ACCESSORIES Yn4 : control and protection units for 1 or 2 lifting pumps. Pump management in fixed, flooded sump or dry well installations; level monitoring and protecting of motor against overcurrents, overloads and dry running. Control unit order reference Intensity range Yn41 Yn42 in A 1 PUMP 2 PUMPE 1.6 to 5 (Yn415)43581 (Yn425)43583 3.7 to 12 (Yn4112)43582 (Yn4212)43584 Probe management card: 4433562 for S4 (I 12A). YN5E Management via microprocessor of one or two pumps in a fixed installation: flooded sump or dry well. Level monitoring and protecting of motor against overcurrents, thermal overloads and dry running. IPAE Electronic Air Pressure Switch for clear and polluted water. - Suitable for operation in an explosive atmosphere. - Suitable for draining and filling. - Complies with directive 94/9/CE (ATEX): protection against explosive atmospheres - Remote control. - Anti-deflagrating. - Insensitive to water temperature and foam. - Acid-resistant. - Undisruptable, highly accurate to within 2 cm and economical - Power supply voltage: 22V - 5 Hz. - Used with the YN 5E. For an ATEX installation use the Zener barrier (see IPAE manual for more information) ORDER Starting intensity range REFERENCE A YN 511E 2521217,5-1 direct YN 521E 2521218,5-1 direct YN 519E 2521219 6,3-9 Y YN 529E 252122 6,3-9 Y YN 5111E 2521221 1-11 Y YN 5211E 2521222 1-11 Y YN 5116E 2521223 12,5-16 Y YN 5216E 2521224 12,5-16 Y YN 512E 2521225 16-2 Y YN 522E 2521226 16-2 Y YN 5132E 2521227 24-32 Y YN 5232E 2521228 24-32 Y YN 5142E 2521229 33,1-42 Y YN 5242E 252123 33,1-42 Y YN 5155E 2521231 42,1-55 Y YN 5255E 2521232 42,1-55 Y YN 5171E 2521233 71 Y YN 5271E 2521234 71 Y NIVO43 Ecological, mercury-free polluted water float switch. Suitable for draining and filling, with discontactor. 8 53 bd de la République - Espace Lumière - Bât. 6-7843 Chatou Cedex FRANCE Tel: +33 ()82 873 624 - Fax: +33 ()1 3 9 82 82 - www.salmson.com