BTV. Internally threaded 2-way control valve. Flow characteristics. Function

Similar documents
2-port seat valves PN25 with externally threaded connections

Two-port seat valves

Seated valves VRB 3, VRG 3

Two-port valves, male threaded, PN25

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

2-Port and 3-Port Seat Valves with Female Thread, PN16

2-port and 3-port seat valves, PN16

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Products no longer available

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

2-Port Seat Valves with Flange, PN 16

Type overview. R B2 en-gb subject to changes 1

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

V311. Venta. Three-way Plug Valve, Flanged PN 16

HERZ - Compact Flow Controller with

2-Port Seat Valves with Flange, PN 16

Overview of types. Technical data. Safety notes

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

3-way control valves VK 3

HERZ - Compact Flow Controller with

Overview of types. Technical data

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

AVP-F. p setting range (bar) Code No. 003H6200

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

VZL valve - 2/3/4-way

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread

2-port and 3-port valves PN 16

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Pressure balanced valves (PN 25) VM 2 2-way valve, external thread VB 2 2-way valve, flange

Seated valve for steam (PN 25)

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

Ballorex Dynamic Description. Versions. Benefits. Balancing

Pressure reduction controller (PN 16, 25, 40)

3-port seat valves with externally threaded connection, PN 16

Pressure balanced valves (PN 25)

Rotary valves HRB 3, HRB 4

AVPQ/AVPQ-F, PN 16. Application

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

Pressure Independent Control Series

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

Rotary valves HRB 3, HRB 4

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

V5434T/H THREE-WAY ROTARY VALVE PN10 AND H-EXTENSION

HERZ-Motorised flow controler

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

Materials : Stainless steel ASTM A351 CF8M

Pressure independent control valve (PICV) FLOWMATIC

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

DS MB, MBF THREE PORT VALVES

Radiator valves VDN2.. VEN2.. VUN2..

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

DS MZ, MZF, MJF THREE-PORT SEAT VALVES

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

STA. Double regulating valves DN 15-50

PCTV/PCMTV/PCTVS15-25

Radiator valves VDN1.. VEN1..

Technote. Frese ALPHA cartridges. Application. Features. Benefits.

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Solenoid valves VZWF, force pilot operated

DRU/HE THREE-WAY ROTARY VALVE PN10 AND HE25/32 EXTENSION

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

PCMTV Pressure independent control valves, DN20-DN32 with integrated flow limiter for thermal emitters and differential pressure regulator

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

STAD. Balancing valves DN 15-50

Technote. Frese PVS - Dynamic Pressure and Flow Regulation Valve. Application. Features. Benefits.

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

kysimply Unique Single Seat

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

FULL FLOW GAS BALL VALVES: LONDON EN 331 APPROVED. GAS BALL VALVES

DIFFERENTIAL PRESSURE REGULATING VALVE

Pressure reducing valves Index

HYDRAULIC CONTROL VALVES

6-way characterised control valves DN15 / DN 20 / DN 25

CALEFFI. Ball zone valves. series /03 GB

DIFFERENTIAL PRESSURE REGULATING VALVE zcon

kyone for All - Unique Mixproof

Pressure independent balancing and control valve AB-QM DN

DN 1/2" to 2 Female - Female BSP - 20 C C Max Pressure : 16 Bars Specifications : Rotating non rising stem Inside screw stem Full bore

Self-operated Pressure Regulators for special applications

Products no longer available

VFPIP/VFPIM/VFPI 15-25

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

VESSEL & REACTOR VALVES. VS Series SPRAY & RINSE VALVES PROCESS VALVES

SV5 Safety Valve Installation and Maintenance Instructions

Transcription:

Internally threaded 2-way control valve The valves are designed for control of hot, cold or glycol-mixed water in heating and ventilation systems. They are pressure balanced (from DN20-50, not DN15) and can therefore handle high differential pressure with low force. The valves are intended to be used together with Regin s RVAN5 actuators. They should not be used in domestic water systems. Size DN15 50 Kvs value 0.6 39 Media temperature -5 +140 C Pressure rating PN16 Rangeability 100:1 No leakage Pressure balanced Function The valve is closed when the stem is in its lowest position and completely open in the highest position. Flow characteristics The flow type is equal percentage according to the figure below. Open valve 2-way valve The valve is pressure balanced and can therefore handle high differential pressure with low actuating force. This means that an actuator with low force can be used. Closed valve Flow 1

Installation Before installation of the control valve, ensure that the pipe is clean. Make sure that pipe scale, metal chips, welding slag and other foreign materials are removed. For maximum efficiency and minimum wear, install the valve in a vertical position with the stem pointing upward. If the valve is mounted with the actuator on the side, more wear is caused to the valve stuffing box. The valve should never be mounted at an angle of more than 90. 90º 90º Install the valve according to the fluid direction arrow shown on the valve. Make sure there is ample space above the valve to facilitate easy removal of the valve actuator. Fit a strainer/filter upstream of the valve to prolong the equipment s life span. A water quality according to VDI 2035 is recommended. 2

Technical data Application Heating systems, cooling systems, ventilation systems Pressure rating PN16 Connection BSP internally threaded according to ISO 228/1 Flow characteristics Equal percentage Max. leakage 0.0 % of the kvs value (PTFE gasket, carbon-filled 25 %, no leakage) Max. diff. pressure 1600 kpa Media Hot water, cold water, glycol-mixed water (max. 50 % glycol) Media temperature -5 +140 C Rangeability 100:1 Stroke 20 mm Material Body Brass CW614N Seat Brass CW614N Plug Stainless steel 1.4301 Stem Stainless steel 1.4305 Seat packing PTFE with 25 % carbon O-rings EPDM Models Article Nominal diameter Connection Kvs Actuator 15-0,6 DN15 G½ 0.6 RVAN5 15-1,0 DN15 G½ 1.0 RVAN5 15-1,6 DN15 G½ 1.6 RVAN5 15-2,5 DN15 G½ 2.5 RVAN5 15-4,0 DN15 G½ 4.0 RVAN5 20-1,6 DN20 G¾ 1.6 RVAN5 20-2,7 DN20 G¾ 2.7 RVAN5 20-3,9 DN20 G¾ 3.9 RVAN5 20-6,3 DN20 G¾ 6,3 RVAN5 25-6,3 DN25 G1 6.3 RVAN5 25-10 DN25 G1 10 RVAN5 32-10 DN32 G1¼ 10 RVAN5 32-16 DN32 G1¼ 16 RVAN5 40-10 DN40 G1½ 10 RVAN5 40-16 DN40 G1½ 16 RVAN5 40-27 DN40 G1½ 27 RVAN5 50-27 DN50 G2 27 RVAN5 50-39 DN50 G2 39 RVAN5 3

Dimensions ø10 70-90 ø44 NV G H A DN A H G NV Stroke 15 70 46 G 1/2 30 20 20 75 48 G 3/4 36 20 25 90 52 G 1 42 20 32 105 55 G 1 1/4 52 20 40 120 67 G 1 1/2 58 20 50 145 70 G 2 70 20 Measurements in mm unless otherwise specified. 4

Pressure drop diagram Example: calculation of kv value If the pressure drop is 10 kpa (A) and the flow is 0.8 m 3 /h (B), the kv value is 2.5 (C). See the markings in the picture to the right. A C B 5